• 제목/요약/키워드: resin

검색결과 7,461건 처리시간 0.036초

The Effects of Resin Ratio and Bed Depth on the Performance of Mixed-bed Ion Exchange at Ultralow Solution

  • Yoon, Tae-Kyung;Lee, Gang-Choon;Noh, Byeong-Il
    • 한국환경과학회지
    • /
    • 제18권6호
    • /
    • pp.595-601
    • /
    • 2009
  • The effects of the cation-to-anion resin ratio and bed depth on ion exchange performance of mixed-bed were studied at ultralow solution concentration. Breakthrough curves were experimentally obtained for NaCI solution as functions of resin ratio and bed depth. The bed depth affects the pattern of the sodium breakthrough curve but not the chloride breakthrough curve in beds because of the selectivity difference. Resin selectivity determines the shape of breakthrough curves, Some sodium and chloride breakthrough curves crossed at a point as a function of resin ratio. The lower cation-to-anion resin ratio showed the higher effluent concentration or treated volume of the crossover point regardless of the total resin weight.

Modeling of the filling process during resin injection/compression molding

  • Chang, Chih-Yuan
    • Advanced Composite Materials
    • /
    • 제16권3호
    • /
    • pp.207-221
    • /
    • 2007
  • The filling process of resin injection/compression molding (I/CM) can be divided into injection and compression phases. During the resin injection the mold is kept only partially closed and thus a gap is present between the reinforcements and the upper mold. The gap results in preferential flow path. After the gap is filled with the resin, the compression action initiates and forces the resin to penetrate into the fiber preform. In the present study, the resin flow in the gap is simplified by using the Stokes approximation, while Darcy's law is used to calculate the flow field in the fiber mats. Results show that most of the injected resins enter into the gap during the injection phase. The resin injection time is extremely short so the duration of the filling process is determined by the final closing action of the mold cavity. Compared with resin transfer molding (RTM), I/CM process can reduce the mold filling time or injection pressure significantly.

의치상 레진의 중합 방법에 따른 크기의 안정성 및 표면 형태에 관한 연구 (DIMENSIONAL STABILITY AND SURFACE MORPHOLOGY OF VARIOUS DENTURE RESINS)

  • 채숙영;방몽숙
    • 대한치과보철학회지
    • /
    • 제30권3호
    • /
    • pp.401-410
    • /
    • 1992
  • The purpose of this study was to investigate the dimensional changes and surface morphology of dentures processed by various polymerization conditions. The measurements were done by taking radiograph and using vernier calipers and each specimen was observed on scanning electron microscope. Results obtained were as follows. 1. The difference of dimensional stability was not recognized between various polymerization conditions(heat-cured resin, pour-type resin, microwave-cured resin, and injection molding resin). 2. There were expansion and shrinkage in the occlusal dimension, shrinkage in the frontal dimension, and expansion in the lateral dimension. 3. Scanning electron microscope pictures of heat-cured resin showed dense and regular surface morphology. 4. Microwave-cured resin surface appeared more regular and smooth than pour-type resin but less dense and more irregular than heat-cured resin. 5. Scanning electron microscope pictures of pour-type resin with the lowest dimensional change showed the most irregular surface morphology.

  • PDF

탄소섬유 첨가에 따른 의치상 레진의 탄성력 관찰 (Study on a Change of Mechanical Property of denture Resin by Carbon Fiber Filler Content)

  • 김호성
    • 대한치과기공학회지
    • /
    • 제36권3호
    • /
    • pp.165-169
    • /
    • 2014
  • Purpose: This study is a mechanical strength supplementation of denture base resin Polymethyl methacrylate (PMMA) is in general use for denture base resin of the partial and full denture, however, The polymerization process of PMMA is not stabilized. Because of compatibility problems, preceding studies were performed, which were enhancing mechanical strength(Camilo Machado 2007),(Ana M. 2008), addition filler to materials property(Ayse Mese, 2008), self curing method(Hiroshi Shimizu, 2008). Methods: The carbon fiber and polyacetal filler, reinforced the mechanical strength for improving the stability of denture base resin were supplemented to the self cured resin. The Modulus of elasticity and the restoring force were calculated by tensile test. Results: The strengths of the heat and self cured resin were respectively decreased and increased, when the filler was supplemented to the denture base resin and the modulus of elasticity of both heat and self cured resin were not increased, when the filler was supplemented to the denture base resin. Conclusion: The restoring forces of self cured resin containing 10% filler were increased, when the filler was supplemented to the denture base resin.

FO-WLP (Fan Out-Wafer Level Package) 차세대 반도체 Packaging용 Isocyanurate Type Epoxy Resin System의 경화특성연구 (Cure Properties of Isocyanurate Type Epoxy Resin Systems for FO-WLP (Fan Out-Wafer Level Package) Next Generation Semiconductor Packaging Materials)

  • 김환건
    • 반도체디스플레이기술학회지
    • /
    • 제18권1호
    • /
    • pp.65-69
    • /
    • 2019
  • The cure properties of ethoxysilyl diglycidyl isocyanurate(Ethoxysilyl-DGIC) and ethylsilyl diglycidyl isocyanurate (Ethylsilyl-DGIC) epoxy resin systems with a phenol novolac hardener were investigated for anticipating fan out-wafer level package(FO-WLP) applications, comparing with ethoxysilyl diglycidyl ether of bisphenol-A(Ethoxysilyl-DGEBA) epoxy resin systems. The cure kinetics of these systems were analyzed by differential scanning calorimetry with an isothermal approach, and the kinetic parameters of all systems were reported in generalized kinetic equations with diffusion effects. The isocyanurate type epoxy resin systems represented the higher cure conversion rates comparing with bisphenol-A type epoxy resin systems. The Ethoxysilyl-DGIC epoxy resin system showed the highest cure conversion rates than Ethylsilyl-DGIC and Ethoxysilyl-DGEBA epoxy resin systems. It can be figured out by kinetic parameter analysis that the highest conversion rates of Ethoxysilyl-DGIC epoxy resin system are caused by higher collision frequency factor. However, the cure conversion rate increases of the Ethylsilyl-DGEBA comparing with Ethoxysilyl-DGEBA are due to the lower activation energy of Ethylsilyl-DGIC. These higher cure conversion rates in the isocyanurate type epoxy resin systems could be explained by the improvements of reaction molecule movements according to the compact structure of isocyanurate epoxy resin.

Pd-Ag 및 Ni-Cr 합금의 금 전착이 전장 레진의 색채에 미치는 영향 (EFFECT OF GOLD ELECTRODEPOSIT OF PD-AG, NI-CR ALLOYS ON THE COLOR OF VENERRED RESIN)

  • 양홍서;박영준
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.645-661
    • /
    • 1995
  • As the mechanical property of composite resin improved, composite resin has been widely used esthetic dentistry. In the field of esthetic dentistry, the color of prosthetic material is very important. The purpose of this study was to evaluate the color difference of specimens, by the types of alloys and gold electrodeposit. Experimental groups were as follows : Group Prec : Au-Pt alloy with no gold coating and no resin veneer. Group Semi : Pd-Ag alloy with no gold coating and no resin veneer. Group BAse : Ni-Cr alloy with no gold coating and no resin veneer. Group Gsem : Pd-Ag alloy with no gold coating and no resin veneer. Group Gbas : Ni-Cr alloy with no gold coating and no resin veneer. Group PreR : Resin veneer on the Pd-Ag alloy without gold coating. Group SemR : Resin veneer on the Pd-Ag alloy without gold coating. Group GbsR : Resin veneer on the Ni-Cr alloy with gold coating Group BasR : Resin veneer on the Ni-Cr alloy without gold coating. In this study, colors of metal surfaces and veneered resins were evaluated by the CIE $L^{*}a^{*}b$ system. The results obtained were as follows : 1. different alloy types and gold coating make the $L^{*}a^{*}b$ system. 2. The ${\Delta}E^*$ab value between groups semi and Base was less than 1.5 and there was no $a^*$ and $b^*$ value difference between groups Gsem and Gbas 3. The values of $L^*$ and $a^*$ ain groups GsemR and GbasR were so similar that the ${\Delta}E^*$ab value was as small as 0.58. 4. In resin specimens with gold coated semiprecious or base alloys showed yellower and redder deviation than the resin specimens with precious alloy. 5. The ${\Delta}E^*$ab values between goups PreR-GsemR and groups PreR-GbasR were as small as 2.68 and 2.22 respectively.

  • PDF

라미네이트 도재와 복합레진 시멘트의 결합강도에 관한 연구 (A STUDY ON THE VOND STRENGTH OF PORCELAIN LAMINATE AND COMPOSITE RESIN CEMENTS)

  • 김성일;임호남;박남수
    • 대한치과보철학회지
    • /
    • 제29권1호
    • /
    • pp.91-109
    • /
    • 1991
  • The purpose of this study were to comfirm the effects of the thickness and kinds of porcelain, etchants, illumination time, elapsed time for the measurement, and chemical cure component to the bond strength of porcelain laminate and composite resin cement, and to compare the effects between the light cured resin and the dual cured resins. The etched porcelain surface, the sectioned surface crossing porcelain and resin after bonding, and the debonded surfaces were observed by the SEM. One product of laminate porcelain powder, one light cured resin and two dual cured resins were selected. Each resin cements are lightened through the thin porcelain disc which was cut from cylindrical porcelain specimen by the diamond saw, and by the light through the porcelain disc they were bonded. Changes of thickness and kinds of porcelain, etchants, illumination time, and the elapsed time for the measurement were considered as variables for the bond strength. And the bond strength of porcelain and dual cured resins under the conditions of autopolymerization or the removal of chemical cure component were measured and compared. Bond strength were measured by shear stress. The etched surface, the cross-sectioned surface, and the debonded surface of porcelain or resin were observed by SEM. On the summary of this study, the following conclusions can be stated; 1. Bond strength of light cured resin was decreased inversely by the thickened porcelain laminate and showed the lowest value to the masking dentin porcelain among 4 kinds of porcelain powder. 2. Bond strength of autopolymerization of dual cured resin without illumination in dark chamber were from 75% to 98% to the data of dual cured resin with illumination. 3. Bond strength of dual cured resin used without chemical cured components were same to them of light cured resin. 4. Cross-sectioned surface treated by silane did not show the gap between the porcelain and resin. 5. Illumination over 80 seconds did not make the significant increase of bond strength on all kinds of resin.

  • PDF

경화제 변화에 따른 WLP(Wafer Level Package)용 신규 Epoxy Resin System의 경화특성 (Cure Properties of Novel Epoxy Resin Systems for WLP (Wafer Level Package) According to the Change of Hardeners)

  • 김환건
    • 반도체디스플레이기술학회지
    • /
    • 제21권2호
    • /
    • pp.57-67
    • /
    • 2022
  • The curing characteristics of naphthalene type epoxy resin systems according to the change of curing agent were investigated to develop a new next-generation EMC(Epoxy Molding Compound) with excellent warpage characteristics, low thermal expansion, and excellent fluidity for WLP(Wafer Level Package). As epoxy resins, DGEBA, which are representative bisphenol type epoxy resins, NE-16, which are the base resins of naphthalene type epoxy resins, and NET-OH, NET-MA, and NET-Epoxy resins newly synthesized based on NE-16 were used. As a curing agent, DDM (Diamino Diphenyl Methane) and CBN resin with naphthalene moiety were used. The curing reaction characteristics of these epoxy resin systems with curing agents were analyzed through thermal analysis experiments. In terms of curing reaction mechanism, DGEBA and NET-OH resin systems follow the nth curing reaction mechanism, and NE-16, NET-MA and NET-Epoxy resin systems follow the autocatalytic curing reaction mechanism in the case of epoxy resin systems using DDM as curing agent. On the other hand, it was found that all of them showed the nth curing reaction mechanism in the case of epoxy resin systems using CBN as the curing agent. Comparing the curing reaction rate, the epoxy resin systems using CBN as the curing agent showed a faster curing reaction rate than them with DDM as a hardener in the case of DGEBA and NET-OH epoxy resin systems following the same nth curing reaction mechanism, and the epoxy resin systems with a different curing mechanism using CBN as a curing agent showed a faster curing reaction rate than DDM hardener systems except for the NE-16 epoxy resin system. These reasons were comparatively explained using the reaction rate parameters obtained through thermal analysis experiments. Based on these results, low thermal expansion, warpage reduction, and curing reaction rate in the epoxy resin systems can be improved by using CBN curing agent with a naphthalene moiety.

교정용 Resin bracket의 마찰 저항력에 관한 연구 (A Study on Frictioal Resistance Force of Orthodontic Resin Bracket)

  • 이원유;임경수
    • 대한치과교정학회지
    • /
    • 제29권1호
    • /
    • pp.107-112
    • /
    • 1999
  • 성인 교정 환자가 증가됨에 따라 교정장치의 심미성이 요구되고 있다. 교정 장치의 심미적 증진을 위해 개발된 브라켓들로는 세라믹, 콤포지트 레진 브라켓, 타이타늄 브라켓등이 소개되고 있다. 콤포지트 레진 브라켓은 우수한 색상 및 투과성이 장점이나 높은 마찰력과 낮은 취성의 단점을 갖고 있다. 이러한 단점을 보완하기 위하여 최근 개발된 세라믹 또는 레진 브라켓(metal reinforced bracket)은 마찰력을 감소시키고 강도를 증가시키기 위하여 브라켓의 슬롯에 메탈을 삽입하고 있다. 그러나 지금까지 이러한 metal reinforced resin bracket(이후 MRRB)의 물성에 관한 연구가 미진하였다. 특히 이러한 브라켓과 교정용 철선의 마찰력에 관한 연구가 미흡하기에 본 연구를 시행하였다. 본 연구는 4종의 교정용 철사(.016 S-S, .0l6X.022 S-S, .016 $TMA^{\circledR}$, .0l7X.025 $TMA^{\circledR}$)와 5종의 브라켓을 사용하였다. 사용된 브라켓들로는 메탈 1종(Ormco.Co., U.S.A)자 세라믹 1종($Crystalline^{\circledR}$), 콤포지트 레진 1종(Clear Medium $Siamase^{\circledR}$), 메탈 슬롯이 삽입된 콤포지트 레진2종($Plastic^{\circledR},\;Spirit^{\circledR}$)의 마찰력을 서로 비교하여 다음과 같은 결과를 얻었다. 1. ceramic bracket과 resin bracket은 metal reinforced resin bracket과 metal bracket보다 마찰력이 유의성 있게 크게 나타났다. 2. metal reinforced resin bracket의 slot내 metal의 삽입형태에 따른 마찰력의 크기는 유의차가 없었다. 3. metal reinforced resin bracket과 metal bracket사이의 마찰력의 크기는 유의차가 없었다. 4.. 교정용 철선과 각 브라켓 비교에서 TMA, Stainless steel 순으로 마찰력이 적게 나타났다.

  • PDF

치과위생사의 임시치관제작 기술 숙련에 대한 인식도 (Recognition on technical skills of temporary resin jacket of dental hygienist)

  • 김경원;김광희
    • 한국치위생학회지
    • /
    • 제9권4호
    • /
    • pp.559-568
    • /
    • 2009
  • Objectives : In order to manage to reformative tendency of the educational whole with change request of dental hygienics education which is diversificated and professionalized the manufacturing practice of a temporary resin jacket which is educated with from much dental hygiene is become accomplished, so far also the recognition which relates with the manufacturing practice of a temporary resin jacket of dental hygiene students there is not researched. The present research carried out the practice evaluation with the target of students of a dental hygiene department, who finished a manufacturing practice of a temporary resin jacket, analyzed and investigated the material, reported its result, and enforced a research. Methods : This research selected students of 6 dental hygiene departments located in the Daegu Gyeongbuk region, who have manufacturing experience of a temporary resin jacket, by a convenient sampling method, and then a questionnaire was executed by a self-administration method, and a total of 290 copies were statistically treated. The content of the questionnaire are composed of 2 questions on an attitude survey before and after manufacturing practice of a temporary resin jacket, 3 questions on an educator for practice of a temporary resin jacket, 7 questions on recognition of technical skills for manufacturing a temporary resin jacket, 9 questions on the practice content evaluation of manufacturing of a temporary resin jacket and recognition on manufacturing practice of a the temporary resin jacket. Results : 1. The average of recognition on technical skills for manufacturing a temporary resin jacket of a dental hygienist was 3.82 points, the average of evaluation on practice content of manufacturing a temporary resin jacket being 3.75 points, and the average of recognition on the practice of manufacturing a temporary resin jacket was 3.71 points. 2. Currently, as the educator for the practice of manufacturing a temporary resin jacket, dental hygienists were 188 persons(64.8%) and dental technicians was 102 persons(35.2%), and as educators they want in the future, dental hygienists were 97 persons(33.3%) and dental technicians was 193 persons(66.7%). Persons hoping reeducation for manufacturing a temporary resin jacket were 219 persons(85.9%). 3. There was a significant difference in consciousness of students before and after practice of manufacturing a temporary resin jacket(p<.001). 4. There was a significant difference in practice evaluation and practice recognition according to the educational subject(p<.001). 5. There was a significant reverse correlation in the educational subject, practice evaluation and practice recognition(p<0.01). Conclusions : The practice for manufacturing a temporary resin jacket in education of dental hygiene is necessary to improve job performance ability in more various and specialized dental treatment and to solve desire for improvement of professional technical skill ability of students, and accordingly. About study process of the future students observation investigation or student objective interview investigation etc. seeks a problem in the become research lead, the succeeding research which gropes the plan which is the possibility of solving the problem which discovered is thought will be necessary.

  • PDF