• Title/Summary/Keyword: residual chlorine

Search Result 192, Processing Time 0.022 seconds

A Study on the Grinding Characteristics According to Cooling Methods (대체냉각 기술을 이용한 환경친화 연삭가공 기술)

  • Lee, S.W.;Choi, H.Z.;Heo, N.H.;Lee, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.962-967
    • /
    • 2003
  • Recently, environmental pollution has become a serious problem in industry, and many researches have been done in order to preserve the environment. The coolant, which promotes lubrication, cooling and penetration, contains chlorine, sulfur and phosphorus to improve the machining efficiency. These additives, which move around into the air during machining, pollute working. Therefore, many researches on how to reduce the amount of coolant during machining have been carried out. However, to reduce even small amount of coolant causes high temperature of a workpiece and it brings thermal defects. In this study, the experiments of wet & dry grinding using cooling methods (using coolant only, mist and compressed cold air only) are performed to solve the problem of environmental contamination and to get a better surface integrity of a workpiece by comparing surface roughness, roundness and residual stress.

  • PDF

Investigating Water Quality Data of Finished Water in Domestic Water Treatment Plants (1994-1998) (국내 정수장 정수 수질자료의 특성분석 (1994년-1998년까지 5년간 자료를 중심으로))

  • Yoon, Jeyong;Cho, Soonhaeng;Kim, Haeshim
    • Journal of Korean Society on Water Environment
    • /
    • v.16 no.4
    • /
    • pp.431-443
    • /
    • 2000
  • Water quality data from water treatment plants in Korea during 1994-1998 were investigated to find out the characteristics of their non compliance. The number of plants surveyed were approximately 600 and the number of samples were over 30,000. Ten parameters of water quality selected in this study and their non compliance % (inside parenthesis) were as follows: Heterotrophic plate count (0.14%), Total coliforms (0.08%), $NH_3$-N (0.29%), $NO_3$-N (0.14%), THMs (0.02%), Turbidity (0.11%), Residual chlorine (5.5%), $KMnO_4$ consumption (0.04%), Hardness (0.03%), pH (0.07%). These levels of non compliance were compared to those obtained from WIDB (Water Industry Database, 1996) of American Water Works Association. This study strongly supported that small water plants (<10,000 tons/day) were more vulnerable in meeting the regulation criteria of many water quality parameters such as Heterotrophic plate count. Total coliforms, $NO_3$-N, THMs, Turbidity, Residual chlorine, $KMnO_1$ consumption, Hardness and pH. The $NH_3$-N concentration was especially high in winter and its violation was frequently found in the specific areas such as the downstream of major rivers. The average THMs concentration was surprisingly low, indicating $13{\mu}g/L$ which is 43% of US. Accordingly, these characteristics must be reflected in establishing the effective management of water quality policy of drinking water in Korea.

  • PDF

A Microbiological Study on the Public Wells in Iri City (공동정호(共同井戶)의 대장균군조사(大腸菌群調査)에 관(關)한 연구(硏究))

  • Han, Kyu-Song
    • Journal of Preventive Medicine and Public Health
    • /
    • v.7 no.1
    • /
    • pp.101-105
    • /
    • 1974
  • A study was carried out for the purpose of grasping the status of bacteriological contamination of the public wells in Iri city, during the period from 1 to 15 August, 1974. Coliform groups were detected by membrane filter method and physical conditions of the wells were checked. As results of this study, following conclusion were obtained. 1. The households which used the piped water occupied 70.8 per cent (11,907 households) out of total householdsir Iri city. 2. Temperature of the well water was 38 out of 50 samples (72.0%) with 12.1 to $16.0^{\circ}C$ and 9 wells with 10.1 to $12.0^{\circ}C$. 3. The pH values range of the well water was 6.0 to 7.9, 11 cases or 22,0 per cent less than 6.5 and 8 cases or 16.0 per cent more than 7.5. 4. The residual chlorine was found at 15 samples (30.0%) contained 0.1 to 0.5ppm, 9 samples (18.0%), 0.6 to 1.0 ppm after 24 houres of chlorination. 5. Coliform groups were found at 49 out of 50 samples (98.0%) before chlorination when 100ml well waters was tested by membrane filter technique and 15 wells(30.0%) were potable for drinking within 24 houres after chlorination. 6. Coliform groups positves were 23 out of 26 samples (88.5%) with no residual chlorine, 12 out of 16 samples (80.0%) with 0.1 to 0.5ppm and none out of 9 with 0.6 to 1.0ppm.

  • PDF

The Characteristics of Oxidation and Adsorption Processes for 2-Methylisoborneol(2-MIB) Removing (2-Methylisoborneol(2-MIB)제거를 위한 산화 및 흡착공정의 특성)

  • 최근주;김상구;류동춘;신판세;손인식;오광중
    • Journal of Environmental Science International
    • /
    • v.11 no.3
    • /
    • pp.241-246
    • /
    • 2002
  • One of the Musty and earthy smell compounds in raw water is generally attributed to 2-methylisoborneol (2-MIB). It is well known that activated carbon and oxidants such as $O_3$, Cl $O_2$, are effective ways to control 2-MIB. In isotherm equilibrium experiments, 2-MIB in distilled water was much more adsorbed to the activated carbon(A/C) than raw water containing dissolved organic carbon (DOC). The Freundlich constants(k) of distilled water and raw water were 3.36 and 0.049, and 1/n values were 0.80 and 0.42, respectively. The 2-MIB residual rate were Y = $e^{-0}$.55x/~ $e^{-0}$.54x/ with Ozone( $O_3$) dose by 5 minutes contact time at the 241 and 353 ng/L initial concentrations. The 2-MIB residual rate were Y = $e^{-0}$.32x/~ $e^{-0}$.35x/ with Chlorine dioxide(Cl $O_2$) dose by 15 minutes contact time at the 89 and 249 ng/L initial concentrations. 2-MIB was decreased from 1911 ng/L to 569ng/L by post-ozonation(70%removal efficiency) and removal efficiencies of 2-MIB by the following 4 kinds Granular Activated Carbon(GAC) process such as coal base, coconut base, wood base and zeolite+carbon base were 95.8, 89.5, 88.4, and 93.7% respectively.ely.

Water quality analyses between tap water and treated water by point-of-use water dispenser systems (정수기 공급수인 수돗물과 정수기 통과수의 수질차이 분석)

  • Park, Keun-Young;Park, Ji-Won;Kim, Jae-Hyeok;Na, Yeong;Maeng, Sung-Kyu;Kim, Sung-Pyo;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.395-404
    • /
    • 2019
  • The point-of-use water dispenser systems are widely used because of convenience in handling and demand for high-quality drinking water. The application has been increased recently in the public places such as department stores, universities and the rest areas in express ways. Improvement of water qualities by the dispenser systems was compared with tap water in this study. The tap water is supplied to the dispenser as the influent of the dispenser system. The twelve dispensers in the public places were used. The five dispensers used reverse osmosis as the main filter and other dispensers used various filters such as ultrafiltration, nanofiltration, and alumina filter. The water quality indicators for sanitation safety, i.e., turbidity and total coliforms, were evaluated. Other water qualities such as pH, residual chlorine, heterotrophic plate count (HPC), and total cell counts were also analyzed. By the point-of-use water dispenser, the turbidity, residual chlorine and pH were decreased and the HPC and total cell counts were increased. The t-test results revealed that the HPC of the tap waters were not significantly different from the treated waters but the total cell counts of the two groups were significantly different. The low pH of the RO filter treatment was also significantly different from the tap waters. This study will contribute to understand the role of the point-of-use water dispenser in improving water quality and to identify key water quality for the proper maintenance of the dispenser systems.

Water Quality Variation and Corrosion Index Characteristics of Underground Reservoir in Apartment (공동주택 지하저수조의 수질변화 및 부식성 특성)

  • JunYoung, Jang;JooWon, Kim;YuHoon, Hwang;KiPal, Kim;HyunSang, Shin;ByungRan, Lim
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.6
    • /
    • pp.275-281
    • /
    • 2022
  • To maintain water quality after water treatment, monitoring whether the quality of treated tap water quality changes is essential. However, current investigations are insufficient to prevent secondary contamination in drinking water supply systems. This study investigated Gyeonggi's e apartment where a red water problem occurred and monitored the water quality and corrosiveness of the overall water supply system to the apartment from June 2021 to April 2022. In a comparison of drinking water quality after water treatment and the influent of the reservoir, turbidity and heavy metal concentrations were increased and residual chlorine was decreased due to increases in temperature. Correlation analysis and principal component analysis (PCA) indicated that a low level of residual chlorine may cause the abscission of Mn2+ and Fe2+ through microorganism activation, which also causes a high level of turbidity. The corrosion index (LI) in the influent of the reservoir tank was increased due to Ca2+ and temperature. These results indicate that the corrosiveness of drinking water and the deterioration of drinking water quality were mainly increased between the drinking water treatment plant and the reservoir tank's influent. The findings provide clear evidence that it is essential to manage water supply systems and reservoir tanks to prevent the secondary contamination of drinking water.

DEPURATION OF LIVE OYSTERS BY CONTROLLING TEMPERATURE, pH AND FREE CHLORINE CONTENT (온도, pH 및 유리염소량의 조절에 의한 오염된 굴의 정화)

  • CHOI Jin-Ho;KIM Chang-Yang
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.12 no.4
    • /
    • pp.255-259
    • /
    • 1979
  • Depuration of extraneous substances such as bottom deposit, feces and coliforms from live oyster has been studied. Coliform accumulation of bottom cultured oysters was much higher than that of raft or long line cultured oysters. When the depuration tank designed in this study was adopted, the depuration rate could be diminished to about $50\%$ within one hour treatment. Tho most effective conditions of the tank water for depurating live oysters wer $22^{\circ}C$ in temperature, 8.80 in pH and below about 2 ppm of residual chlorine concentration.

  • PDF

Effect of Temperature on $H_2$ Spillover over $Pt/H_xMoO_3$ (Pt를 담지한 $H_xMoO_3$촉매의 수소 이동 속도에 미치는 온도의 영향)

  • 김진걸
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.2
    • /
    • pp.114-117
    • /
    • 2004
  • Rates of $H_2$ uptake into $Pt/MoO_3$ were measured for the noncalcined and $200^{\circ}C$ calcined $Pt/MoO_3$. Amount of $H_2$ uptake for $200^\circ{C}$calcined $Pt/MoO_3$ was greater than the amount of noncalcined $Pt/MoO_3$. From these two experiments, it was found that the rates of $H_2$ desorption were proportional to the increase of desorption temperature. XPS demonstrated that Cl reduced more faster in ITR after calcination at $200^{\circ}C$. This inducd smaller amount of residual chlorine at adlineation sites between Pt and $MoO_3$ substrates. This resulted in opening the more channel of hydrogen pathway into more $MoO_3$particles and controled the kinetics of hydrogen uptake.

  • PDF

Fungal Load of Groundwater Systems in Geographically Segregated Islands: A Step Forward in Fungal Control

  • Joong Hee Cho;Nam Soo Jun;Jong Myong Park;Ki In Bang;Ji Won Hong
    • Mycobiology
    • /
    • v.50 no.5
    • /
    • pp.345-356
    • /
    • 2022
  • The fungal distribution, diversity, and load were analyzed in the geographically segregated island groundwater systems in Korea. A total of 79 fungal isolates were secured from seven islands and identified based on the internal transcribed spacer (ITS) sequences. They belonged to three phyla (Ascomycota, Basidiomycota, and Chlorophyta), five classes, sixteen orders, twenty-two families, and thirty-one genera. The dominant phylum was Ascomycota (91.1%), with most fungi belonging to the Cladosporium (21.5%), Aspergillus (15.2%), and Stachybotrys (8.9%) genera. Cladosporium showed higher dominance and diversity, being widely distributed throughout the geographically segregated groundwater systems. Based on the diversity indices, the genera richness (4.821) and diversity (2.550) were the highest in the groundwater system of the largest scale. As turbidity (0.064-0.462) increased, the overall fungal count increased and the residual chlorine (0.089-0.308) had low relevance compared with the total count and fungal diversity. Cladosporium showed normal mycelial growth in de-chlorinated sterilized samples. Overall, if turbidity increases under higher fungal diversity, bio-deterioration in groundwater-supplying facilities and public health problems could be intensified, regardless of chlorine treatment. In addition to fungal indicators and analyzing methods, physical hydrostatic treatment is necessary for monitoring and controlling fungal contamination.

The PWM Control Which used Microprocessor for Intensity Control of Acid Ion Water (산성이온수 농도제어를 위한 Microprocessor를 이용한 PWM 제어)

  • Kwon, Yunjung;Nam, Sangyep
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.269-274
    • /
    • 2013
  • We are used with the alkaline ion water which an application field does to object for drinking water compare with the alkaline ion water which asked ion acid electrolysis so as to be very different. This is used with sterilization disinfection use by residual chlorine in case of strong acidity according to ph intensity, and in case of middle acidity use by washing and face washing, and mix with meal materials in case of weak acidity widely usable in cooking. Acid ion water generates as we electrolyze water. Chlorine gas and sodium hydroxide etc. was generated at electrolysis process, and we have toward sterilizing power. Derelicts such as chlorine, phosphorus, sulfur etc. are gathered from a negative ion, and we make acid ion water to + electrode direction in electrolysis. We used a diaphragm in order to disconnect too acid water and alkaline water. We implemented so that the acid water which it came down to three kinds of PWM voltage to PWM (pulse width modulation) control, and implementation method of ph intensity change authorized ph intensity between weak acidity to electrode in strong acidity as we used Microprocessor, and intensity was adjusted successively by PWM control was generated.