• Title/Summary/Keyword: residential distribution

Search Result 451, Processing Time 0.03 seconds

Characteristics and Recycling of Sewer Sediments from Land Use (토지이용별 하수관거 퇴적토의 특성과 재활용)

  • Won, Chul-hee;Lee, Byung-won;Choi, Joong-dae;Rim, Jay-myoung
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.3
    • /
    • pp.404-410
    • /
    • 2009
  • In this study, research for physical and chemical characteristics were conducted through analysis of sediments, grading and heavy metals (e.g., Mn, Cu, Cd, Zn and Pb ) in sewers which are classified by drainage types. After that, cement solidification and yellow soil calcinations made heavy metals stabilized and then, ways of recycling it were examined. The grain size distribution of all sediments was relative graded. When evaluating heavy metal pollution through index of geoaccumulation (Igeo), Cu showed moderately pollution or strong pollution in forest and street site and Zn was assessed by moderately pollution in military, residential, and street site. Analysis of Pearson Correlation coefficient of heavy metal indicated that all items in street site have tight relationship respectively. Especially, Cd-Zn, Cu-Pb, Cu-Mn, and Pb-Mn have relationship at 99% confidence intervals in statistical analysis. Recycling it with cement solidification was satisfied with compressive strength standard under 55% deposit contents and Zn, Pb, Mn were stabilized effectively. If time and temperature plasticity and compressive strength would be standard, it is revealed that yellow soil calcinations is valuable aggregate when it has 50-60 Wt% contents. When considering economic feasibility and stabilization of heavy metals, cement solidification would be more appropriate than yellow soil calcinations as solution to recycling.

Groundwater Quality and Contamination Characteristics Associated with Land Use in Ulsan Area (울산지역 토지이용도에 따른 지하수 수질 및 오염특성)

  • Lee, Byeong-Dae;Yun, Uk;Sung, Ig-Hwan
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.78-91
    • /
    • 2007
  • The groundwater chemistry is heavily influenced by land use. This study has investigated the groundwater quality and contamination characteristic associated with land use. Contamination index ($C_d$) was estimated for evaluating and areal distribution of groundwater contamination degree. Groundwater samples collected from 216 locations in the study area show great variability in chemical composition. Electrical conductance ranges from 100 to $31,360\;{\mu}S/cm$. The pH values are between 4.6 (acidic) and 8.57 (weak alkaline). The water types predominantly represent the $Ca-HCO_3$ and $Ca-Na-HCO_3$ types, whereas, in the residential and business areas, the water type is shifted to (Na, Ca)-Cl type with rich concentration of Cl. The $C_d$ values of the study area range from 1.1 to 117.6 with a mean of 9.56.

An Analysis of the Characteristics of the Transition Trand of the Multi-family Housing Theory by Planning Community Units - Focused on the new town planning in Korea - (생활권 개념의 변화에 따른 주거지 계획의 시기별 특성 변화 - 국내 신도시 및 신시가지 계획을 중심으로 -)

  • Yi, Jong-Hwa;Koo, Ja-Hoon
    • Journal of the Korean housing association
    • /
    • v.20 no.4
    • /
    • pp.79-88
    • /
    • 2009
  • A planned access method on constantly-changing-community unit plan changes and develops based on the periodical situation and also plan theory. In this research, it is to present the link between the theory of complex city change and the plan factor of it, and to show how Korean residential complex plan has changed as time passed and how new concept of city plan came up and by applying new methods how can this affect our real world and the past plan. In the phase of analysis, it analyzed the flow of 'community unit plan' and its theory and investigated the factor of compositional space and built a analysis frame. The factors of community unit plan are space structure, size and shape of block, population, distribution of facilities and movement system. It chose the place that can represent the flow of community unit plan trand and that indicates the obvious development leading to Jamsil (1975), Gwa Chun (1980), Mok Dong (1983), Sang Ge (1985), Ilsan (1989), Dong tan (2001) and Eun Jung (2003) total of 7 places. And to compare a similar size of the city, it selected a small community unit. Based on the result of theoretical study and prior research, it can be said that the space composition style has change from a whole complete complex area to a linked-cross over community unit and the access of urban level was on set. Also, a pedestrian walking area was secured and the dense of building structure and pleasant environment wanting need was in balance. For facility plans, the usage of facility and functional change brought change of type, size and disposition. The walking area for pedestrian became a huge matter. Therefore, market, education, public facilities and green system collaborated to co-build a whole community unit and activated the walking environment. Also, public transportation, environment friendly city organization was built.

Development of the Sentiment Indicators of Housing Welfare (주거복지지표 개발에 관한 연구 II - 수요자 측면의 주거복지체감지표와 지수를 중심으로 -)

  • Jee, Eun-Young;Eun, Nan-Soon;Hong, Hyung-Ock
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.85-92
    • /
    • 2008
  • The aim of this research is to develop the sentiment indicators of housing welfare for evaluating housing welfare policies conducted by the Korean government. The methods of this research are used by analysis of related documents, FGI (Focus Group Interview), and survey. The survey was made by experts and consumers. To analyze the survey, this research also uses confirmatory factor analysis by SPSS (Statistical Package for the Social Science) program, AHP (Analytical Hierarchy Process) by Expert Choice program, frequency, average, percentages, Factor analysis etc. As a result of this research, selected housing welfare indicators are settled as follows: In the housing welfare aspect, 11 indicators in the department of 'Housing Satisfaction' and 11 indicators in the department of 'Community Satisfaction' (22 in total) are suggested. The indicators are 1) Water Supply and Distribution Equipment 2) Heating equipment 3) the size of the exclusive residential area 4) the number of rooms 5) Ventilation and Lighting 6) Sound Insulation (Indoor Noise) 7) Air Pollution/Odor 8) House Deposit 9) Rent Paid 10) Maintenance (Dwelling) Cost 11) The length of Occupation 12) Proximity to Welfare Facilities 13) Educational Environment 14) Convenience of Facilities (shops, hospitals etc.) 15) Convenience of Transportation and Commuting 16) Distance from Workplace 17) Landscape and Green Space (Tree, Flowers, Grass etc.) 18) Vandalism (Destruction Behavior, graffiti etc.) 19) Privacy 20) Noise in Public Places (Drinking, Loudly Talking etc.) 21) Safety from Crime 22) Safety from a Disaster. As of 2007, the housing welfare sentiment index is measured by the survey of 1,000 inhabitants in the public housing, which shows 3.51.

Experimental seismic behaviour of L-CFST column to H-beam connections

  • Zhang, Wang;Chen, Zhihua;Xiong, Qingqing;Zhou, Ting;Rong, Xian;Du, Yansheng
    • Steel and Composite Structures
    • /
    • v.26 no.6
    • /
    • pp.793-808
    • /
    • 2018
  • In this study, the seismic performance of the connections between L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) and H-beams used in high-rise steel frame structures was investigated. Seven full-scale specimens were tested under quasi-static cyclic loading. The variables studied in the tests included the joint type, the axial compression ratio, the presence of concrete, the width-to-thickness ratio and the internal extension length of the side plates. The hysteretic response, strength degradation, stiffness degradation, ductility, plastic rotation capacity, energy dissipation capacity and the strain distribution were evaluated at different load cycles. The test results indicated that both the corner and exterior joint specimens failed due to local buckling and crack within the beam flange adjacent to the end of the side plates. However, the failure modes of the interior joint specimens primarily included local buckling and crack at the end plates and curved corners of the beam flange. A design method was proposed for the flexural capacity of the end plate connection in the interior joint. Good agreement was observed between the theoretical and test results of both the yield and ultimate flexural capacity of the end plate connection.

Influence of Residential Environment and Lifestyle on Multiple Primary Malignancies in Taiwan

  • Chang, Chih-Chun;Chung, Yi-Hua;Liou, Ching-Biau;Lee, Yi-Chen;Weng, Wei-Ling;Yu, Yun-Chieh;Yen, Tzung-Hai;Wu, Jiann-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3533-3538
    • /
    • 2015
  • Background: Multiple primary malignancies (MPM) have become increasingly prevalent worldwide. This investigation was aimed at establishing the clinicopathological characteristics of MPM patients and evaluating the impact of the living environment on MPM in the Taiwanese population. Materials and Methods: From January 2009 to December 2013, a total of 8,268 cancer patients were identified in our institutional center. Of these, 125 were diagnosed as MPM and thus enrolled. Data for clinicopathological features and treatment approaches for these MPM patients living in urban or suburb zone were obtained. Findings for the air pollution status in Taiwan were also collected. Results: The most common cancer match of MPM was esophageal cancer with hypopharyngeal cancer (12.8%), followed by colorectal cancer with gastric cancer (6.4%) and colorectal cancer with breast cancer (5.6%). The air quality was significantly worse in the urban than in the suburban zone and there was a remarkably higher portion of MPM patients in the urban zone suffering from grade III and IV post-chemotherapeutic neutropenia (30.8% vs 15.1%, P=0.036). Conclusions: The tumor frequency and site distribution should be taken into the clinical evaluation because there is a relatively high risk of developing MPM. This study also highlighted the potential influence of environmental factors on post-chemotherapeutic neutropenia for patients with MPM.

Statistical Analysis on Residuals from No-Fault Reference Models of a Residential Heat Pump System in Normal Cooling Operation (가정용 열펌프 시스템의 정상냉방 운전조건에서 기준모델에 의한 잔차의 통계적 분석)

  • Kim, Min-Sung;Yoon, Seok-Ho;Baik, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1351-1358
    • /
    • 2011
  • To approximate the threshold of the fault detection and diagnosis (FDD) system, validation of the measurements is mandatory. Naturally, the system shows uncertainties due to measuring sensors - mostly thermocouples or RTDs - and due to repeatability. The uncertainty of a thermocouple comes from natural variation or a drift of the thermocouple measurement. Considering the natural variation behaves like zero-mean white noise, its natural variation can be characterized closely by the steady-state standard deviation. However, residuals between measurements and no-fault references in FDD systems show a statistical distribution with various uncertainties. In this paper, steady-state variations of measurement residuals were investigated by utilizing built-in temperature sensors in a heat pump for the model development and the final application.

A study on smoking status and related factors in Korean adolescents determined using data from the 5~7th(2010-2016) Korea National Health and Nutritional Examination Survey (제 5~7기(2010-2016) 국민건강영양조사 자료를 활용한 한국 청소년의 흡연 실태와 관련요인 연구)

  • Jung, Eun-Ju;Song, Ae-Hee;Youn, Hye-Jeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.5
    • /
    • pp.621-630
    • /
    • 2018
  • Objectives: The purpose of this study was to investigate the smoking status and related factors among adolescents in Korea. Methods: We used data from the 5-7th Korea National Health and Nutrition Examination Survey. The distribution of smokers and smoking status according to general characteristics was analyzed using complex chi-square tests. Multiple logistic regression was used to analyze the relationship between smoking experience and general characteristics by calculating the 95% confidence intervals. Results: There were 618 subjects who had experience smoking one or two puffs, the starting age of one or two puffs on smoking was 14.37 years old, the number of smoking days per month was 12.42 days, and the amount of smoking per day in a month was 7.59. Gender, residential area, income level, drinking experience, subjective health status, perceived stress level, continuous depression for more than 2 weeks, suicidal thoughts within a year, and age were significantly related to smoking experience. Conclusions: It is necessary to understand the smoking behavior of adolescents. It is important to lower the smoking rate among adolescents through the development and operation of systematic smoking prevention and smoking cessation policies at the national level, as well as the efforts of youth themselves to quit smoking.

Analysis of Land Conversion Characteristics in Process of Farmland Loss and Urbanization by Distance from Center of City Using Detailed Digital Land Use - With Representative Big Cities and Their Fringe Areas in Japan - (정밀수치정보를 이용한 도시중심에서 거리별 농지손실 및 도시화과정의 토지전용 특성 분석 - 일본의 대표적 도시주변지역을 중심으로 -)

  • Kim, Dae-Sik
    • Journal of Korean Society of Rural Planning
    • /
    • v.9 no.1 s.18
    • /
    • pp.65-75
    • /
    • 2003
  • As a pre-step research to make land-use planning in the region level, this study aims to analyze some probability pattern representing transition probabilities from farmland to others using the sequential detailed digital land-use maps. Kinki and Chubu regions of Japan, which have Osaka and Nagoya cities as their center places respectively, were selected as test regions in this study. The 10m grid land-use maps for four time series at every 5 year from 1977 to 1992 were used. In this study, the regions were divided into three sub-areas 10km, 20km, and 30km according to distance from center cities, respectively. The correlation coefficient (CC) between sub-areas with same distance in the two regions was calculated to analyze whether or not the two regions have common points in the pattern of land-use conversion probability from farmland to other types. The probability distribution of the converted areas which were moved to the urbanized area (residential, commercial, industrial, road, park and public facility areas) was about $40{\sim}70%$ for both all periods and sub-areas. According to distance from city centers, the probability moved to the urbanized area was about 60% at 10km area, and 40% at the 30km area, which means that the values we decreased gradually, while in the case moved to the forest and the etc areas, the values were increased slightly. The CC analysis from the paddy field and the dry field to the others separately showed that there is high correlation in the probability pattern between the two regions.

Temperature Change Analysis for Land Use Zoning Using Landsat Satellite Imagery (Landsat위성영상에 의한 용도지역 온도변화분석)

  • Jung, Gil-Sub;Koo, Seul;Yoo, Hwan-Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.2
    • /
    • pp.55-61
    • /
    • 2011
  • The land use has been changed artificially and caused the result of temperature increase of city compared with the outside of city or region of park and forest. The purpose of this research is to analyze the change of the urban surface temperature with land use zoning in Jinju using Landsat TM/$ETM^+$ imagery and to provide the correlation between NDVI(Normalized Difference Vegetation Index) and urban surface temperature change. The results presented that the spatial distribution of urban surface temperature was depending on the change of NDVI values on land use zoning. Considering to the average temperature by land use zoning, industrial area was the highest temperature but green area was the lowest temperature. Also as a result of comparing the correlation between surface temperature and NDVI, the green and residential area had higher correlation values than the commercial and industrial area. These results will be played a part as one of the major factors for implementing the sustainable urban planning considering the urban heat island effect problem.