• 제목/요약/키워드: repeated structure

검색결과 609건 처리시간 0.028초

Seismic performance of precast joint in assembled monolithic station: effect of assembled seam shape and position

  • Liu, Hongtao;Du, Xiuli
    • Earthquakes and Structures
    • /
    • 제17권6호
    • /
    • pp.611-621
    • /
    • 2019
  • Precast concrete structure has many advantages, but the assembled seam will affect potentially the overall seismic performance of structure. Based on the sidewall joint located in the bottom of assembled monolithic subway station, the main objectives of this study are, on one hand to present an experimental campaign on the seismic behavior of precast sidewall joint (PWJ) and cast-in-place sidewall joint (CWJ) subjected to low-cycle repeated loading, and on the other hand to explore the effect of shape and position of assembled seam on load carrying capacity and crack width of precast sidewall joint. Two full-scale specimens were designed and tested. The important index of failure pattern, loading carrying capacity, deformation performance and crack width were evaluated and compared. Based on the test results, a series of different height and variably-shape of assembled seam of precast sidewall joint were considered. The test and numerical investigations indicate that, (1) the carrying capacity and deformation capacity of precast sidewall and cast-in-place sidewall were very similar, but the crack failure pattern, bending deformation and shearing deformation in the plastic hinge zone were different obviously; (2) the influence of the assembled seam should be considered when precast underground structures located in the aquifer water-bearing stratum; (3) the optimal assembled seam shape and position can be suggested for the design of precast underground concrete structures according to the analysis results.

반복배열된 토마토 phenylalanine ammonia-Iyase(p AL X1, PAL X2) 유전자의 구조해석 (Structural Analysis of Repeated Tomato Phenylalanine Ammonia-Lyase Gene (PAL X1, PAL X2))

  • 이신우;여윤수
    • Applied Biological Chemistry
    • /
    • 제42권1호
    • /
    • pp.34-38
    • /
    • 1999
  • 토마토의 genome내에는 적어도 5개 이상의 PAL유전자 좌가 존재한다는 사실을 이 등(1992)이 이미 genomic Southern blot hybridization으로 확인하여 보고하였다. 그러나 본 연구에서 제작한 genomic DNA libraries를 대상으로 검색한 결과 기존에 보고된 PAL유전자 이외에 약 15 kb 와 10 kb에 해당하는 큰 EcoRI 단편을 확보 할 수 있었다. 이들 단편을 BamHI, HindIII등 9종의 제한효소를 사용하여 Southern blot hybridization을 행한 결과 PAL X1의 경우는 모든 효소에 대하여 2개의 단편이 hybridization 되었으며, 특히 BamHI으로 절단하여 얻은 3개의 단편중 두 개는 PAL5 유전자의 exon 2 부위에서 취한 oligomer(18 mer)와 primer extension 반응이 진행되어서 약 200 bp의 PAL유전자와 아주 높은 상동성을 갖는 염기서열이 확인되었다. 따라서 PAL X1유전자는 2 copy의 유전자가 나란히 존재하거나 아니면 염색체 재배열이 진행된 것으로 추정된다. 이러한 결과는 적어도 7개 이상의 PAL유전자 좌가 토마토 염색체내에 존재하는 것으로 사료된다.

  • PDF

KR60 레일의 미세조직과 기계적 물성 평가 (Investigation of Microstructure and Mechanical Properties of KR60 Rail)

  • 최욱진;조희재;윤경민;민경환;임남형;이수열
    • 한국재료학회지
    • /
    • 제27권12호
    • /
    • pp.652-657
    • /
    • 2017
  • The use of continuous welded rail is increasing because of its many advantages, including vibration reduction, enhanced driving stability, and maintenance cost savings. In this work, two different types of continuous welded rails were examined to determine the influence of repeated wheel-rail contact on the crystal structure, microstructure and mechanical properties of the rails. The crystal structure was determined by x-ray diffraction, and the microstructure was examined using optical microscopy and scanning electron microscopy. Tensile and microhardness tests were conducted to examine the mechanical behaviors of prepared specimens taken from different positions in the cross section of both newly manufactured rail and worn rail. Analysis revealed that both the new and worn rail had a mixed microstructure consisting of ferrite and pearlite. The specimens from the top position of each rail exhibited decreased lamella spacing of the pearlite and increased yield strength, ultimate tensile strength and hardness, as compared with those from other positions of the rail. It is thought that the enhanced mechanical property on the top position of the worn rail might be explained by a mixed effect resulting from a directional microstructure, the decreased lamella spacing of pearlite, and work hardening by the repeated wheel-rail contact stress.

강한 지진하중하에서 강부재의 정량적인 손상 모델 (Quantitative Damage Model of Steel Members under Severe Seismic Loading)

  • 박연수;박선준
    • 한국강구조학회 논문집
    • /
    • 제10권3호통권36호
    • /
    • pp.339-353
    • /
    • 1998
  • 본 논문에서는 정량적인 지진 손상모델의 유도를 위해 먼저 지진 반복하중하에서 구조물 및 그들 요소에 대한 기존의 손상 모델들을 체계적으로 정리한 후 문제점을 평가하였다. 또한, 강한 지진과 같은 심한 반복가력을 받는 강구조 부재에 대한 파괴기준을 묘사하였으며, 강부재에 대한 새로운 지진 손상도 평가방법을 제안하였다. 이 손상모델은 극저 사이클 하중하에서 강부재에 대한 일련의 실험과 수치해석 연구로부터 얻어진 것이다. 본 연구에서 극저 사이클 하중은 큰 소성변형 영역안에서 5~20 사이클의 반복하중을 의미한다. 제안된 내진 손상평가 방법은 변형이 가장 심하게 집중된 단면에 있어서 국소 변형율의 이력에 초점을 맞추어 유도되었다.

  • PDF

단락 자동 구분을 이용한 문서 요약 시스템 (Korean Summarization System using Automatic Paragraphing)

  • 김계성;이현주;이상조
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제30권7_8호
    • /
    • pp.681-686
    • /
    • 2003
  • 본 논문은 단락의 자동 구분을 통해 중요한 문장을 추출하는 요약 시스템을 제안한다. 먼저 어휘의 재출현 여부를 파악하여 어휘의 일치도와 어휘의 역할 변화와 같은 재출현 어휘의 양상 정보를 수집하고, 이를 통하여 문장 간의 긴밀도를 정량적으로 계산한다. 다음으로 측정된 문장간 긴밀도를 이용하여 사용자의 추출 범위에 따라 단락을 구분하고, 각 단락의 대표 문장을 선정하여 최종 요약문을 추출한다. 제안한 방법은 문서 제목, 문장의 위치, 수사 구조 등의 정보를 이용하지 않기 때문에 수사 구조가 자주 발견되지 않는 문서에도 적용이 가능하다.

양모/아크릴 혼방사 편성물의 방축 효과 및 물성에 관한 연구 (Shrink-Resist Effects and Properties of the Knitted Fabrics from Wool/Acrylic Fiber Blends)

  • 이연희;곽수경;박명자
    • 복식문화연구
    • /
    • 제12권6호
    • /
    • pp.945-952
    • /
    • 2004
  • Shrink-resist effects and properties of the knitted fabrics from wool/acrylic(W/A) fiber blends were determined to find out an optimal blending ratio keeping the quality properties of wool products. The test fabrics were knitted by a weft knitting machine with all needle knitting structure ($0{\times}0$ rib) under the same knitting conditions with five different types of yarns: $W100\%,\;A100\%$, and W/A blended yarns(70/30, 50/50, 30/70). Shrinkage during repeated washing, electrostatic propensity, thermal resistance and pilling propensity of W/A knits. The shrink resistance was significantly enhanced on repeated washing of W/A knits, especially, over $50\%$ acrylic blended knits. Addition of strong physical force and alkali detergent applied in this washing experiment brought about superior effects with the low shrinkage rate although it was very severe washing conditions for wool fabrics. The results from the washing experiment implies that W/A blend knits can be machine washed at individual households with other ordinary laundry. There was some changes and variation found in thermal resistance, electrostatic propensity, and pilling. W/A 50/50 blended knits did not bring serious changes to other physical properties comparing with original wool, which helps consumers care wool knitted clothes more conveniently.

  • PDF

지오그리드로 보강된 투수성 연성포장 보조기층제 영구변형을 고려한 층두께 산정 비교 연구 (Evaluation of Geogrid-Reinforced Subbase Layer Thickness of Permeable Flexible Pavements based on Permanent Deformation Model)

  • 권혁민;오정호;한신인
    • 한국도로학회논문집
    • /
    • 제17권1호
    • /
    • pp.69-75
    • /
    • 2015
  • PURPOSES : The objective of this study is to evaluate the effectiveness of a geogrid reinforced subbase of permeable flexible pavement structures with respect to permanent deformation. METHODS : Experimental trials employing a repeated triaxial load test scheme were conducted for both a geogrid reinforced subbase material and a control specimen to obtain the permanent deformation properties based on the VESYS model. Along with this, a finite element-based numerical analysis was conducted to predict pavement performance with respect to the rutting model incorporated into the analysis. RESULTSAND CONCLUSIONS : The results of the experimental study reveal that the geogrid reinforcement seems to be effective in mitigating permanent deformation of the subbase material. The permanent deformation was mostly achieved in the early stages of loading and then rapidly reached equilibrium as the number of load applications increased. The ultimate permanent deformation due to the geogrid reinforcement was about 1.5 times less than that of the control specimen. Numerical analysis showed that the permeable, flexible pavement structure with the geogrid reinforced subbase also exhibits less development of rutting throughout the service life. This reduction in rutting led to a 20% decrease in thickness of the subbase layer, which might be beneficial to reduce construction costs unless the structural adequacy is not ensured. In the near future, further verification must be conducted, both experimentally and numerically, to support these findings.

PZT 후막의 미세 구조적 특성에 조성과 전구체 용액의 코팅이 미치는 영향 (Effect of Composition and Coating of Precursor Solution on a Micro Structural Properties of PZT Thick Films)

  • 박상만;노현지;이성갑
    • 한국전기전자재료학회논문지
    • /
    • 제19권11호
    • /
    • pp.1014-1019
    • /
    • 2006
  • The influence of the number of solution coatings on the densification of the PZT thick films was studied. PZT powder and PZT precursor solution was prepared by a sol-gel method and PZT thick films were fabricated by the screen-printing method on the alumina substrates. The powder and solution of composition were (A) PZT(80/20)/PZT(20/80), (B) PZT(70/30)/PZT(30/70) and (C) PZT(60/40)/PZT(40/60), (D) PZT(52/48)/PT. The coating and drying procedure was repeated 4 times. And then the PZT precursor solution was spin-coated on the PZT thick films. A concentration of a coating solution was 0.5 moth and the number of coating was repeated from 0 to 6. The porosity of the thick films was decreased with increasing the number of coatings and the PZT thick films with 6-times coated showed the dense microstructure and thickness of about $60{\mu}m$. A grain size was increased with increasing the coating number. All PZT thick films showed the typical XRD patterns of a typical perovskite polycrystalline structure. The relative dielectric constant of PZT thick films was improved 30-100% as the number of coatings.

Solution 코팅횟수에 따른 PZT(80/20)후막의 특성 (Properties of PZT(80/20) Thick Films with the Variation of the Number of Solution Coatings)

  • 박상만;이성갑;이영희;배선기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1418-1419
    • /
    • 2006
  • PZT(80/20) powder was prepared by a sol-gel method and PZT thick films were fabricated by the screen-printing method on the alumina substrates. The coating and drying procedure was repeated 4 times. And then the PZT(20/80) precursor solution was spin-coated on the multilayered thick films. A concentration of a coating solution was 0.5 mol/L and the number of coating was repeated from 0 to 6. The porosity of the thick films was decreased with increasing the number of coatings and the PZT thick films with 6-times coated showed the dense microstructure and thickness of about 60-65 ${\mu}m$. All PZT thick films showed the typical XRD patterns of a typical perovskite polycrystalline structure. The relative dielectric constant and the dielectric loss of the PZT-6 thick film were 275 and 3.5, respectively. And the PZT-6 film shows the remanent polarization of 22.1 $C/cm^2$ and coercive field of 13.7 kV/cm.

  • PDF

반복충격에 의한 섬유강화 복합재료의 피로수명 특성 평가 (Evaluation of Fatigue Life Characteristic of a Fiber-Reinforced Composites under the Repeated Impact Loading)

  • 최정훈;김형익;허용;석창성;장필수;이창희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.1025-1028
    • /
    • 2005
  • Generally, fiber-reinforced composites have the highest possibilities of impact damages with external object collisions. Also, resulting in fatigue fracture considering the continued impact load. For the reasons mentioned above, the accurate understanding of interactions between the impact of composites and the fatigue load will be essential to understand the safety level of material structures. Furthermore, the composite materials and structures, due to the geometrical effect, vary the life in connection with the impact-fatigue. Therefore, I have reached the point that a focus of this study will be to evaluate fatigue fracture characteristics by the impacts-fatigue load of fiber-reinforced composites. Thus, in this paper, I have tried to work on impacts-fatigue load causing aspects and impact characteristics through impact-fatigue test on HTV-5Hl Black 9250 material made- structure, along with to evaluate the expected lift of real structures, the FEM analysis was carried out.

  • PDF