• 제목/요약/키워드: remediation system

검색결과 224건 처리시간 0.034초

원위치 지반오염정화사업에서의 실시간 모니터링 시스템의 적용 사례 (Application of Real-Time Monitoring System to In-Situ Soil Remediation Project)

  • 정승용;김병일;한상재;김수삼;홍상기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1384-1389
    • /
    • 2005
  • A real-time monitoring system for in-situ soil remediation technologies is developed and then applied to electrokinetic remediation technique in the field trial tests during 150days. The developed system is consisted the controlled program based on internet web page, data logger, measurement instruments and so on. In the measured items there are pH, temperature, electrical current and potential, vacuum pressure. The results indicated that the system is successively applied to electrokinetic remediation technique, and further research considering economic view and multi purpose system for in-situ soil remediation technologies is needed.

  • PDF

마을단위 소규모 하·폐수처리 공정의 효율적 유지관리를 위한 전문가 시스템에 관한 연구 (An Innovative Expert System for the Maintenance of On-site Wastewater Treatment Process for Small-scale Residential and Commercial Sites)

  • 김승준;최용수;홍석원;권기한;정익재
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.132-140
    • /
    • 2005
  • The pilot test of a new alternative for small wastewater treatment system has been conducted for two years. It consists of a hybrid bioreactor and the expert system including the process control logic, PLC system, and HMI for the process automation. In order to monitor and remote control its status, the real-time data was transferred from the on-site control center to the central station via a wireless local area network. More efficient and stable performances were observed at automatic operating mode compared with the manual. On an average, COD, SS, T-N and T-P concentrations in the effluent from the hybrid bioreactor were less than 14, 7, 12 and 0.9 mg/L, respectively. According to the result from pilot tests, the quality of treated wastewater with sand filtration was enough to be utilized again.

Hybrid Pilot System을 이용한 철도 오염토양 복원 (Remediation of Contaminated Railroad Soils using by Hybrid Pilot System)

  • 박덕신
    • 한국철도학회논문집
    • /
    • 제3권3호
    • /
    • pp.101-108
    • /
    • 2000
  • In this study, we tested hybrid pilot system combined with soil vapor extraction and bioventing methods on the contaminated railroad soil. So, we found out the remediability and operating conditions. Air permeability(k) and gas phase(O$_2$/CO$_2$/VOCs) level trend are very important to determine the remediation rate of the contaminated sites. Throughout hybrid pilot test on different conditions, the range of air permeability(k) was 1985∼1194 darcy. The tests results in hybrid system was appropriate on this test sites, and the suitable injection air flow rate was 3.5㎥/hr. So, we suggested a basic data for the remediation and management of contaminated railroad soil.

  • PDF

연직배수재를 이용한 오염도턍복원 특성 평가 (Evaluation of Remediation of Contaminated Soil Using PVDs)

  • 신은철;박정준;노정민
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1400-1407
    • /
    • 2005
  • There are a number of approaches to in situ remediation that are used at contaminated sites for removing contaminants from the contaminated zone without excavating the soil. These include soil flushing, dual phase extraction, and soil vapor extraction. Of these techniques, soil flushing is the focus of the investigation in this paper. The concept of using prefabricated vertical drains(PVDs) for remediation of contaminated sites with fine-grained soils is examined. The PVD system is used to shorten the drainage path or the groundwater flow and promote subsurface liquid movement expediting the soil flushing process. The use of PVDs in the current state of practice has been limited to soil improvement. The use of PVDs under vacuum conditions is investigated using sample soil consisting of silty sand.

  • PDF

Geoinformation decision support system for remediation of the 137Cs contaminated agricultural lands after the Chernobyl NPP accident

  • Titov, Igor Evgenievich;Krechetnikov, Viktor Vladimirovich;Mikailova, Rena Aleksandrovna;Panov, Aleksei Valerievich
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2244-2252
    • /
    • 2022
  • Based on GIS technologies, a decision support system (GIDSS) has been developed to remediate agricultural lands in the Bryansk region (Russia) contaminated by 137Cs after the accident at the Chernobyl nuclear power plant. GIDSS is a multilevel system consisting of basic, information and computational layers. GIDSS allows justifying a targeted approach for the remediation of agricultural lands belonging to agricultural enterprises for the production that meets the established radiological requirements for the content of radionuclides. Evaluation of the effectiveness of alternative remediation technologies and the selection of optimal measures were carried out at the level of elementary plots using radiological criteria. The introduction of GIDSS will enable agricultural producers in the south-western districts of the Bryansk region to conduct radiation-safe agro-industrial production in radioactively contaminated areas, which will help improve the socio-economic situation of the region and return it to normal living conditions.

불포화 자연토의 동전기 시스템에 따른 정화 특성 (The Remediation Characteristics of Natural Soil according to ElectroKinetic Remediation Systems under Unsaturated Conditions)

  • 김병일;김기년;한상재;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.873-881
    • /
    • 2004
  • A serious of EK remediation tests on contaminated soil are performed under unsaturated conditions and analyzed for electrical potential, water content, pH and so on. The results indicated that electrical potential and pH distributions in the sample are dependent on the amount and inward/outward flow of hydrogen ion. Specially, for the closed system the water content is largely decreased with the flow of hydrogen. The maximum electrical conductivity is measured at the catholyte of CEM(Sealing) test and directly related to the remedial efficiency. Although pHs in the region near to the anode are similarly developed, the different concentration of lead is measured with the electrical gradient contrary to the lead concentration dependent on pH within the sample.

  • PDF

콘크리트 댐 기초 누수방지 보수그라우팅 사례 (A Case Study of Remediation Grouting for Stopping Leakage of Concrete Dam Base)

  • 천병식;김진춘;최영철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.449-456
    • /
    • 2000
  • Remediation grouting has been widely used for the rehabilitation of various civil works like hydraulic and traffic structures. Recently there were some cases of remediation grouting for repairing old dams in korea. So this study will describe the case of remediation grouting of the concrete dam base located east-northern part of Seoul. We use Lugeon Test and Borehole Image Processing System(BIPS) for estimating the effectiveness of remediation grouting of this project. As the results of this study, we could find the lots of joints between the old concrete body and the weathered rock base. So the about 30% quantity of total cement grouts was injected at the boundary surface between concrete and rock base. And Lugeon Test and BIPS could be compared relatively because BIPS results could be presented quantitatively as well as qualitative analysis. Finally, we could find microfine cement was very effectively injected to the fine fissured concrete body compared with ordinary portland cement, but there was little injectability differences beteween microfine cement and ordinary portland cement at the large cracks or cavities were developed rock base.

  • PDF

수치해석 방법에 의한 연직배수시스템의 오염토양 복원효율 비교분석 (The Comparison of Remediation Efficiency for Contaminated Soils under Vertical Drain System by Numerical Analysis Method)

  • 신은철;이성철;박정준
    • 한국지반신소재학회논문집
    • /
    • 제10권1호
    • /
    • pp.29-36
    • /
    • 2011
  • 오염지반 복원을 목적으로 사용한 연직배수시스템의 적용성 평가를 위하여 영향 인자에 대한 지반공학적 특성을 기초로한 파일럿 규모의 실내 오염복원 실험시 오염물질의 복원 효율을 분석하였다. 또한, 도출된 결과를 바탕으로 유한요소 및 유한차분방법에 의한 수치해석을 수행하였으며, 해석시 적용된 물성값에 대한 매개변수를 평가하였다. 오염복원 모형실험과 수치해석에서 최소한계농도비를 기준으로 하여 오염복원율 해석 결과, 지반이 조밀한 경우 최소한계 농도비 도달시간이 더 길어지며, 지속시간에 따른 농도분포를 살펴보았을 때, 농도는 주입배수재를 중심으로 그 주변에서 더 빠르게 제거되고, 반면에 추출배수재 주변에서는 농도가 더 높게 나타남을 알 수 있었다.