• Title/Summary/Keyword: remedial action

Search Result 34, Processing Time 0.026 seconds

A Study on Methodology for Automated Contingency and Remedial Action Analysis based on Practical Approach: Development of Automated Scheduled Outage Analysis Tool (실용적 접근 기반의 전력계통 해석 프로그램 상정고장, 해소방안 자동화 기법: 휴전검토 자동화 툴 개발)

  • Song, Jiyoung;Ko, Baekkyung;Shin, Jeonghoon;Han, Sangwook;Nam, Suchul;Lee, Jaegul;Kim, Taekyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1171-1179
    • /
    • 2014
  • ISO(Independent System Operator) or TSO(Transmission System Operator) use power system analysis program to simulate contingency analysis and remedial actions to operate power system stably. Generally, power system analysis program provides automated analysis functions(or modules) to deal with wide area power system. However, because of missed contingency cases, automated contingency analysis has no practical use or has limitation. And in case of remedial action, it doesn't support automated function or takes a lot of times to study, because of simulation in manual for each cases. This paper suggests that new relation with buses and transmission line properties of power system DB used for power system analysis program to simulate automated contingency including all contingency cases needed in the field without missed cases. And it proposes automated remedial action scheme based on practical approach analysis to alleviate overloading or voltage problems. Finally it deals with automated contingency/remedial action analysis(automated scheduled outage) program which is developed by KEPCO and its performance and proposed schemes are proven by case study for real Korean power system data.

Assessment of Indoor and Outdoor Air Quality through Determination of Microorganism (미생물을 이용한 일부 병원, 가정 및 일반 대기질의 평가)

  • Ha, Kwon Cheol;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.73-81
    • /
    • 1991
  • To assess biological air quality, concentrations of viable airborne microbes were determined in hospital home and outdoor air from August 25 to October 18, 1990. Bacteria, fungi and thermophilic bacteria were sampled using gravitational and suctional sampling method. In bacteria groups, the Staphylococcus spp. was identified by microscopic examination and biochemical tests. Results of the study are as follows. 1. Results using the gravitational sampling method indicated that average numbers of airborne microbes in hospital home and outdoor air were 21.5, 12.2 and 17.6 CFU/plate, respectively. These levels are well within an appropriate standard of 50 CFU/plate suggested by Endo. 2. Results using the suctional sampling method indicated that total airborne microbe concentrations in hospital, home and outdoor air were 1,998, 1,363 and $1,880CFU/m^3$, respectively. All of the results were within the recommended remedial action level, $10,000CFU/m^3$ of the American Conference of Governmental Industrial Hygienists(ACGIH). 3. Concentration of thermophilic bacteria in hospital and outdoor air were 79 and $111CFU/m^3$, respectively. Thermophilic bacteria were not detected in the home air. These results were within the remedial action level, $500CFU/m^3$. 4. Concentrations of Gram negative bacilli in holpital home and outdoor air were 20.3, 23.6 and $16.8CFU/m^3$, respectively. all were within the remedial action level, $500CFU/m^3$, recommended by ACGIH. 5. Concentrations of Staphylococcus spp. in hospital, home and outdoor air were 34.8, 14.7, and $22.4CFU/m^3$. respectively. all were within the remedial action level, $75CFU/m^3$, recommended by ACGIH. The percentages of Staphylococcus spp. in total bacteria in hospital, home and outdoor air were 19.0, 10.2 and 14.5%, respectively.

  • PDF

Consumer Post-Purchasing Behavior of Internet Shopping - Focusing on Dissatisfaction and Complaint Behavior - (의류제품의 인터넷 구매 후 행동에 관한 연구 - 불만족 요인과 불평 행동을 중심으로 -)

  • Park, Soo-Kyeong;Cho, Nam-Hae
    • The Research Journal of the Costume Culture
    • /
    • v.18 no.2
    • /
    • pp.217-228
    • /
    • 2010
  • The purpose of this study was to examine the post-purchasing behavior focusing on dissatisfaction and complaint behavior. There were some studies concerning dissatisfaction in on-line shopping related to satisfaction and intention to re-buying, but did not focus the relationship with complaint behavior, or identified the factors specifically related to consumer's dissatisfaction. In this study, it was examined to minimize the consumer's dissatisfaction and complaint behavior by investigating the detailed factors relating dissatisfactions and complaint behaviors after shopping apparel goods on the internet. Two hundred fifty five customers who had purchased fashion products in internet shopping had participated in this study. The data was analyzed by factor analysis, regression analysis using SPSS program. As the result, first, product, delivery, returning and price factor were extracted as factors of dissatisfaction, and as factors of complaint behavior, legal action, private action, remedial action were investigated. Second, dissatisfaction was significantly effected on complaint behavior. Specially, returning factor and price factor had effect on legal action, product, delivery factor had on private action and returning factor had affected remedial action. Third, more purchasing frequency, less dissatisfaction. Also, female had more dissatisfaction than male. Finally, more dissatisfaction and compliant behavior, less repurchasing intention. Based on these results, internet shopping fashion marketing strategies were suggested.

The Study of Microbial Population & Dynamics in Hydrocarbon Contaminated Areas (유류오염지역의 미생물 분포 및 활성도에 관한 연구)

  • 김무훈;김순기;이원권;경우성;박덕신
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1999.10a
    • /
    • pp.28-31
    • /
    • 1999
  • The purpose of this study is to see the effect of microbial population and dynamics of the indigeonous microorganisms on hydrocarbon contaminated areas. The microbial structures and activities to determine the microbial capabilities of the contaminated sites are very important for the remedial action technology selection. Throughout microbial studies on different conditions by ETS(Electron Transport System) and microbial activity analysis, it was found that aeration and water contents are the most important factors in this site remediation. According to test results, Burkholderia spp. was dominant species, and acclimation is also an important factor for the accerelated biodegradation.

  • PDF

SOURCES OF HIGH LEVERAGE IN LINEAR REGRESSION MODEL

  • Kim, Myung-Geun
    • Journal of applied mathematics & informatics
    • /
    • v.16 no.1_2
    • /
    • pp.509-513
    • /
    • 2004
  • Some reasons for high leverage are analytically investigated by decomposing leverage into meaningful components. The results in this work can be used for remedial action as a next step of data analysis.

A Study on the Warning Limit of Statistical Control Chart by the Heuristic Approach (휴리스틱접근법(接近法)에 의한 관리도(管理圖)의 경고한계선(警告限界線)에 관한 연구(硏究))

  • Gang, Hyo-Sin
    • Journal of Korean Society for Quality Management
    • /
    • v.12 no.2
    • /
    • pp.15-24
    • /
    • 1984
  • Since W.A. Shewhart (1931) developed the quality control method using the control chart, many theoretical and empirical works about such an analytical method have been done. However there are two major methods relating to the control chart analysis; the conventional 3 sigma control method and the warning limit method which has been suggested as a modification of the former. The conventional 3 sigma method requires to take a remedial action only when a quality characteristic is beyond the control limit (3 sigma). However, once a quality characteristic is over the control limit, searching and repairing an assignable cause requires time consuming job and high costs. Therefore if we set the warning limit between the central line and the control limit, we will be able to take remedial measures before too late. In spite of its advantage, much attention has not been paid to use the control chart with warning limit in Korean industries. The main object of this study is to examine improvement of quality and productivity when the control chart with warning limit is used.

  • PDF

A clinical study of Soyangin Yangkyuksanwhatang (양격산화탕(凉膈散火湯) 활용(活用)에 대(對)한 임상적(臨床的) 연구(硏究))

  • Park, Seong-sik;Kim, Ji-yong;Choi, Jae-young
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.2
    • /
    • pp.455-471
    • /
    • 1998
  • Background and Purpose : We intended to be helpful to understand constitutional symptoms of a disease and an application of the prescription through a clinical study of Soyangin Yangkyuksanwhatang. Methods : We studied 65 patients(40 men and 25 women) treated with Soyangin Yangkyuksanwhatang in constitutional clinic of Dongguk Pundang Oriental Hospital. And then we investigated the characteristics of Yangkyuksanwhatang treated patients, remedial values, onset of action and side effects. Results: Soyangin Yangkyuksanwhatang was used in all age groups both men and women. There were 37 kinds of chief complaints including chest discomfort, numbness of hands and feet, motor disturbance and skin disease etc. The distributions of remedial values were slightly improved(58.5%), much improved(12.3%), no improved(29.3%) and there was no aggravated patient. Using the prescription, mostly I prescribed only Soyangin Yangkyuksanwhatang without any changing, and added some herbs to the prescription according to the symptoms of a disease. Soyangin Yangkyuksanwhatang was affected in remedial values by the addition and subtraction of herbs. The onset of action in young age group was shorter than old age group. Side effects were palpitation, abdominal pain and indigestion etc.

  • PDF

Corporate Training for ISO-14000 (ISO-14000 대비 기업의 환경관리 교육)

  • 차근호
    • Hwankyungkyoyuk
    • /
    • v.6 no.1
    • /
    • pp.133-137
    • /
    • 1994
  • The main step for many multinational corporations when initiating an environmental management system is the formulation and implementation of an environmental audits aimed at identifying environmental problems requiring remedial action. Environmental management systems such as BS 7750 and the Eco-Management and Audit Scheme offer an opportunity to enhance environmental performance and assess the quality of management system is the availability of inhouse environmental expertise, which can be provided through training programmers.

  • PDF

A Case History of Confinement of the Contaminated Landfill Using a Vortical Barrier (연직 차수벽을 이용한 폐기물매립지 침출수 오염 제어 사례 연구)

  • 이재영;정문경;고재만
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.2
    • /
    • pp.163-174
    • /
    • 1999
  • This paper presents a case history of remedial action adopted for contaminated groundwater in a landfill. The objectives of the projects are : (1) to effectively confine contaminated groundwater with an economically reasonable means, (2) to prevent further contamination of soil by collecting and treat the contaminant. and (3) to assure the environmental safety of the landfill during its operating period. Reported are the process from site investigation, through design and construction of an appropriate remedial action, to the monitoring of the selected confinement system. In view of the results of site investigation, deep soil mixing cutoff wall using the DMW(deep soil mixing cutoff wall) method and specially produced HEC soil stabilizer were used for the construction of deep soil mixing cutoff wall. For rock foundation with sever fractures, chemical grout curtain with urethane was installed. The monitoring results to date indicate that the selected vertical barrier performed satisfactorily.

  • PDF

The effects of various thermal parameters on coil temperature rise in TEFC induction motor (여러가지 열적 변수가 전폐형 유도전동기의 코일온도상승에 미치는 영향에 관한 연구)

  • Yun, Myeong-Geun;Ha, Gyeong-Pyo;Go, Sang-Geun;Lee, Yang-Su;Han, Song-Yeop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.4
    • /
    • pp.570-578
    • /
    • 1997
  • At design stage of new motor or when taking remedial action of old motor, a lot of information can be obtained from thermal parameters analysis. This study focused on the temperature rise of TEFC induction motor with respect to various thermal parameters. Frame heat transfer had the most important effect on coil temperature rise. But those of air gap and rotor fan had no effect. This fact shows fan action is more important than fin action in the case of rotor fan. Coil temperature can be more decreased by cooling near the heat sources than any other parts from the results of thermal conductivity and loss tests. Variation of cooling air flow rate and motor volume effects on coil temperature were also tested. These tests suggest that improvement of cooling fan performance is important in reducing the coil temperature rise. Thermal equivalent program was verified by comparison of some experimental results.