• Title/Summary/Keyword: reliability cost evaluation

Search Result 272, Processing Time 0.023 seconds

Comparative Performance Evaluation of 10kV IGCTs in 3L ANPC and TNPC Converters in PMSG MV Wind Turbines (PMSG 풍력발전기용 3L ANPC와 TNPC 컨버터에서의 10kV IGCT 성능 비교 평가)

  • Lyngdoh, Amreena Lama;Suh, Yongsug;Park, Byoung-Gun;Kim, Jiwon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.6
    • /
    • pp.419-427
    • /
    • 2019
  • Several multilevel converter topologies have been proposed and compared. The three-level (3L) neutral-point-clamped (NPC) topology is promising and widely accepted. However, this topology suffers from uneven loss distribution among switches due to its fixed switching strategy. The 3L active NPC (ANPC) topology, which exhibits improved loss distribution profile, was proposed to address this disadvantage. The 3L T-NPC topology, a hybrid configuration of 2L and 3L NPC topologies, was introduced to address not only the loss distribution problem but also the reduction in the number of switches. In the present research, the application of these three topologies in PMSG-based medium-voltage wind turbines was investigated. The power devices considered were 10 kV IGCTs. Performance was evaluated in terms of a power loss of 10 kV IGCT for each NPC topology, which is a crucial indicator of thermal behavior, reliability, cost, and lifetime of any converter. The comparison was performed using ABB make 10 kV IGCT 5SHY17L9000 and the simulation tool PLECS.

A Study on the Evaluation of Linear Cumulative Damage Factor of Membrane Type LNG Tank by use of Probability Density Function (확률밀도함수를 이용한 멤브레인방식 LNG탱크의 선형누적손상도 평가에 관한 연구)

  • 김종호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.993-999
    • /
    • 2004
  • The estimation of fatigue life at the design stage of membrane type LNG tank is very important in order to arrive at feasible and cost effective solutions considering the total lifetime of the tank. In this study, the practical procedure of fatigue life prediction by use of cumulative damage factors based on Miner-Palmgren hypothesis and probability density function has been shown with the corner region of Gaz Transport Membrane type LNG tank being used as an example. In particular the parameters of Weibull distribution that determine the stress spectrum are discussed. The main results obtained from this study are as follows: 1. The recommended value for the shape parameter of Weibull distribution for the LNG tank is 1.1 in case of using the direct calculation method proposed in this study. 2. The calculated fatigue life is influenced by the shape parameter of Weibull distribution and stress block. The safe fatigue design can be achieved by using higher value of shape parameter and the stress blocks divided into more stress blocks.

Evaluation on the Creep Life Prediction Using Initial Strain Method (초기 연신율법을 이용한 크리프 수명예측 평가)

  • Kong, Yu-Sik;Lim, Man-Bae;Lee, Sang-Pill;Yoon, Han-Ki;Oh, Sae-Kyoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1069-1076
    • /
    • 2002
  • The high temperature creep behavior of heat machine systems such as aircraft engines, boilers and turbines in power plants and nuclear reactor components have been considered as an important and needful fact. There are considerable research results available for the design of high temperature tube materials in power plants. However, few studies on the Initial Strain Method (ISM) capable of securing repair, maintenance, cost loss and life loss have been made. In this method, 3 long time prediction Of high temperature creep characteristics can be dramatically induced through a short time experiment. The purpose of present study is to investigate the high temperature creep lift of Udimet 720, SCM 440-STD61 and 1Cr-0.5Mo steel using the ISM. The creep test was performed at 40$0^{\circ}C$ to $700^{\circ}C$ under a pure loading. In the prediction of creep life for each materials, the equation of ISM was superior of Larson-Miller Parameter(LMP). Especially, the long time prediction of creep life was identified to improve the reliability.

A study on the quantitative risk grade assessment of initial mass production for weapon systems (초도양산 군수품에 대한 정량적 위험등급평가 방안 연구)

  • Jung, Yeongtak;Ham, Younghoon;Roh, Taegoo;Ahn, Manki;Ko, Kyungwa
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.3
    • /
    • pp.441-452
    • /
    • 2018
  • Purpose: The purpose of this paper is to study quantitative risk grade assessment for objective government quality assurance activities based on risk management in initial mass production for weapon systems. Methods: The Defense quality management regulations and foreign risk assessment documents are referred to analyze problems performing quality assurance actives. The failure rate data, maintainability and cost of products have been studied to quantify the risk Likelihood and impact. The analyzed data were classified as risk grade assessment through K-means Cluster Analysis method. Results: Results show that a proposed method can objectively evaluate risk grade. The analyzed results are clustered into three levels such as high, middle and low. Two products are allocated high, eleven low and seven middle. Conclusion: In this paper, quantitative risk grade assessment methods were presented by analyzing risk ratings based on objective data. The findings showed that the methods would be effective for initial mass production for weapon systems.

Applicability of Statistical Evaluation to Power Quality Analysis (통계적 방법을 이용한 전력품질 관리방안)

  • Cho, Soo-Hwan;Jang, Gil-Soo;Kwon, Sae-Hyuk;Park, Sang-Ho;Jeon, Young-Soo;Kwak, No-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.22-24
    • /
    • 2006
  • The installations of power quality monitoring system have increased drastically over the past several decades. These systems have been effectively used to monitor, analyze and diagnose the conditions of power system, and furthermore can be used to improve the present asset maintenance policy, scheduled (time-based) method, into the advanced, cost-effective and labor-effective maintenance methods, such as condition-based maintenance, predictive maintenance and reliability centered maintenance. As an approach to this, this paper introduces the statistical methods, three kinds of control charts (Shewhart chart, CUSUM chart and EWMA chart), and discusses the applicability of these methods to recognize the changing trends of power quality indices and to estimate the system's condition, using Matlab.

  • PDF

Study on Verification Evaluation of Wireless Network Introduction for Waterworks Supervisory and Control (수도사업장 감시제어를 위한 무선통신망 도입 신뢰성검증 연구)

  • Lee, An-Kyu;Park, Eun-Chul;Lee, Dong-Hoon;Hong, Sung-Taek;Kim, Nam
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.6
    • /
    • pp.195-200
    • /
    • 2009
  • In this paper, we verified the reliability through local examination by introducing a wired network that is operated at the local waterworks to wireless LAN based Wi-Fi network. The adopted wireless network compared to the existing wired network through saving cost and reducing breakdown points have been proven to be effective qualitatively and quantitatively. This study proved that wireless networks could be introduced for the advancement of operations management of existing metropolitan water supply and the local waterworks that are operating currently.

  • PDF

A Study on Measurement Selection Algorithm for Power System State Estimation Under the Consideration of Observability (가관측성을 고려한 전력개통 상태추정을 위한 측정점선정 알고리즘에 관한 연구)

  • Lee, T.S.;Lee, E.H.;Rho, T.H.;Hong, H.S.;Kuk, H.J.;Moon, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.523-526
    • /
    • 1995
  • This paper presents an improved algorithm of optimal measurement system design with a reliability evaluation method for a large power system. The proposed algorithm is developed to cosider the observability and to achieve highest accuracy of the state estimator as well with the limited investment cost. When the effect on these dummy bus measurements is considered in the proposed algorithm the other errors in the power system is also detected and then analyzed until to achieve the limited values. By taking advantage of the matrix sparsity and the optimal bus ordering the memory and the time are successfully reduced in the P/C's and workstation's model. The improved program is successfully tested for IEEK sample system and KEPCO system with PSS/E lineflow calculated data package.

  • PDF

Design and Performance Evaluation of Cooperative Hybrid CDD Scheme in OFDMA Up-link Network (OFDMA 상향링크 네트워크에서 협력 하이브리드 기법의 설계 및 성능 평가)

  • Kim, Dae-Hwan;Song, Hyoung-Kyu;Cho, We-Duke
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.7C
    • /
    • pp.435-442
    • /
    • 2011
  • The MIMO has weak points such as size and cost of systems and the complexity of hardware augment. Thus, the cooperative transmission techniques have been recently discussed briskly and it also solves problems by increase of shadowy area. However, limited cooperation scheme is utilized due to a single-antenna at the destination. The base station is simply equipped with multiple antennas. When the base station has multiple antennas, cooperative diversity and multiplexing schemes can be easily applied in the base station. To guarantee reliability with high throughput, a cooperative hybrid cyclic relay diversity transmission scheme is proposed which can use an arbitrary number of relays without rate loss and a modification of the base station. The presented results show that the proposed schemes can be effectively applied to the existing various MIMO-OFDM communication system.

A Study on the Fuzzy ELDC of Composite Power System Based on Probabilistic and Fuzzy Set Theories

  • Park, Jaeseok;Kim, Hongsik;Seungpil Moon;Junmin Cha;Park, Daeseok;Roy Billinton
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.3
    • /
    • pp.95-101
    • /
    • 2002
  • This paper illustrates a new fuzzy effective load model for probabilistic and fuzzy production cost simulation of the load point of the composite power system. A model for reliability evaluation of a transmission system using the fuzzy set theory is proposed for considering the flexibility or ambiguity of capacity limitation and overload of transmission lines, which are subjective matter characteristics. A conventional probabilistic approach was also used to model the uncertainties related to the objective matters for forced outage rates of generators and transmission lines in the new model. The methodology is formulated in order to consider the flexibility or ambiguity of load forecasting as well as capacity limitation and overload of transmission lines. It is expected that the Fuzzy CMELDC (CoMposite power system Effective Load Duration Curve) proposed in this study will provide some solutions to many problems based on nodal and decentralized operation and control of an electric power systems in a competitive environment in the future. The characteristics of this new model are illustrated by some case studies of a very simple test system.

Uniqueness of radiographic patterns of the frontal sinus for personal identification

  • Patil, Neha;Karjodkar, Freny R.;Sontakke, Subodh;Sansare, Kaustubh;Salvi, Rohini
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.213-217
    • /
    • 2012
  • Purpose: This study was performed to evaluate the uniqueness and reliability of the frontal sinuses by comparing various patterns of frontal sinus as observed on Waters' radiographs for individual identification. Materials and Methods: Three Waters' radiographs of 100 individuals, taken on day one, after 6-8 months, and one radiograph with a slight variation in angulation, to mimic conditions out in the field or during autopsy. Three observers were randomly given radiographs from all there packets for comparisons and identification, by the method of superimposition and individual uniqueness. Results: The comparative identification by superimposition of the frontal sinus was 100% positive. The size, shape, unilateral or bilateral presence, absence, and septa were observed to be unique in each case; neither had the measurements changed over a period of time. Conclusion: The need to establish a reliable, low-cost, and easily reproducible method for human identification prompted the elaboration of technical, precise, and accessible parameters, such as the evaluation of the area, asymmetry, and shape of the frontal sinus. Comparison among each of the frontal sinuses of the 100 people in the sample revealed that no two sinuses are the same, that is, the sinus is unique to each individual.