• Title/Summary/Keyword: relay system

Search Result 1,267, Processing Time 0.024 seconds

Development of automation system for relay on/off voltage adjustment using neural network (신경 회로망을 이용한 Relay 작동전압 조정 자동화 시스템 개발)

  • 국금환;최동엽
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.43-48
    • /
    • 1992
  • The automation system oriented as one of the second year automation projects for the small and medium sized enterprises(SME) was developed for the improvement of the production rate and cut the required manpower in the field of the relay which is one of the small electric components used in various industrial fields. The objectives of this study are not only improving the international competition of the relay itself but also partially solving the technical and financial problems featured by common bottlenecks of the SME for efficient assembly automation. For the purpose of these objectives, several topics are studied as followings. - Analyzing the adjustment process and determining the specification of the automation system. - Determining the layout for the automation system to meet the determined specification. - Detail design of the automation system for relay adjustment and inspection. - Control system design - Automation system development and performance test.

  • PDF

Development of An Expert System to Decide the Resetting Area of Protective Distance Relay in Power Transmission Systems (송전계통 보호 거리계전기 재정정 영역 판정 전문가시스템 개발)

  • 최면송;민병운;김기화;현승호;이승재
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.8
    • /
    • pp.437-443
    • /
    • 2003
  • In this paper an expert system is developed to decide the resetting area of protective devices in power transmission systems. A configuration change in power transmission networks from a substation extension such as new line or bus addition need resetting of protective devices around the point of configuration changes. To find the resetting area in complex power system is very difficult, especially when the distance protective relays are considered to be reset. The proposed expert system, in this paper to find the resetting area has many rules based on the changes of fault currents and apparent factors from the power system alteration. It solves the problem to find relay resetting area using the network information in the database and the rule-base. The case study shows a result of the problem to find relay resetting area in KEPCO system when there is any configuration change.

Implementation of Multimedia Services in a Mobile Ad-hoc Network (이동 Ad-hoc 네트워크에서의 멀티미디어 서비스 구현)

  • Ro Kwang-Hyun;Kwon Hye-Yeon;Shin Jae-Wook;Park Ae-Soon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.2
    • /
    • pp.45-52
    • /
    • 2006
  • Mobile Ad-hoc Network(MANET) could be applied to various applications by virtue of its characteristics such as self-organizing and infrastructure-free network. This paper proposes a multimedia application service model for MANET, called multi-hop Relay(mRelay) system. It supports a multi-hop communication-based multimedia service interworked with Internet by using an unmanned moving robot with wireless multimedia communication function as a mRelay terminal. The modified AODV routing protocol was applied to the terminal and it was verified that composition and maintenance of mobile Ad-hoc network in mRelay system under the various indoor scenarios were successful and stable multi-hop multimedia services were possible. The mRelay system can be applicable to various application services of mobile Ad-hoc networks.

  • PDF

A basic study on protective relay testing using RTDS in power system applying SFCL (초전도한류기 적용계통에서의 RTDS 보호계전기 연계시험을 위한 기본연구)

  • Lee, Seung-Ryul;Yoon, Jae-Young;Kim, Jae-Ho;Lee, Byong-Jun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.35-39
    • /
    • 2009
  • The study for a protective relay system is one of the important technical issues on the power system application of Superconducting Fault Current Limiter (SFCL). We used Real Time Digital Simulator(RTDS) to study the true interaction of the protection system with the power system. RTDS modeling of SFCL is necessary to the detailed protective relay tests. In this paper, we developed an analysis model using RTDS for studying the transient behavior of 22.9kV SFCL and carried out closed-loop testing of protective relays in distribution power system with the developed SFCL model. The SFCL model has the operation mechanism of 22.9kV hybrid SFCL being developed by LSIS and KEPRI in Korea. The parameters of the model are based on the test data of the real SFCL. Power system planners and operators can solve the expected problems in power system application of SFCL using protective relay testing results.

Development of PCM Current Differential Relay Setting Module Using UML (UML(Unified Modeling Language)기법을 이용한 PCM전류차동계전기 정정모듈 개발)

  • Oh, T.W.;Oh, S.M.;Min, B.U.;Lee, S.J.;Choi, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.329-331
    • /
    • 2003
  • PROSET2000 that is integrated protective management system had developed and used in order to automate the setting process of protective relays in transmission system protection. PROSET2000 have database for relay setting and automated for relay setting program within. This paper proposed PCM current differential relay setting program point of Object Oriented Programming paradigm using Unified Modeling Language about additional relay in PROSET2000. Nevertheless each relay uses same current differential but setting method is different. This paper discribed different thing about setting method of each relay and evaluated more effective and corrective relay setting program using UML.

  • PDF

Development of Ground Fault Protective Relaying Schemes for DC Traction Power Supply System (DC 급전시스템의 지락보호계전시스템 개발)

  • Chung Sang-Gi;Jeong Rag-Gyo;Cho Hong-Sik;Lee Ahn-Ho;Kwon Sam-Young
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.9
    • /
    • pp.427-433
    • /
    • 2005
  • In DC tracking power supply system, ground faults are currently detected by the potential relay, 64P. Though 64P relay detects ground fault, it cannot Identify the faulted region which causes long traffic delays and safety problem to passengers. Two new ground fault protective relay schemes that can identify the faulted region are presented in this paper. One is bus differential protective relay and the other is ground overcurrent protective relay. Both type of relays is similar in principle to the ordinary bus differential protective relay and the ground overcurrent relay used in other power system. In DC traction power supply system, since it is ungrounded, ground fault current is not big enough to operate those relays. To solve the problem, a current control device, called device 'X', is newly introduced in both system, which enables large amount of ground fault current flow upon the positive line to ground fault. Algorithms for these relays are developed and their validity are verified by EMTP simulation.

Performance of MIMO-OFDM Systems using The Relay With Multi-Antennas for Cooperative Diversity (Put English Title Here) (다중 안테나의 relay를 가진 MIMO-OFDM시스템의 Cooperative diversity에 따른 성능)

  • Kim, Chan-Kyu;Kim, Young-Il
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.6
    • /
    • pp.13-19
    • /
    • 2008
  • In this paper, the new cooperative communication techniques is proposed for multi-input multi-output(MIMO)-orthogonal frequency division multiplexing (OFDM) system using the relay with multiple antenna. As the MIMO channel is formed by space time coding at the MS(mobile station)-RS(relay station) and RS-BS(base station), we can get the cooperative diversity and MIMO diversity gain simultaneously. Therefore, the performance of MIMO-OFDM system using the relay with multiple-antennas is very improved. And the simple power allocation technique is Proposed for the transmitting power of the mobile station and the relay.

Design of the Power System Frequency Measurement Module for the Relay using the Digital Phase Locked-Loop (디지털 위상 고정 루프를 이용한 계전기용 정밀 주파수 측정 장치)

  • 윤영석;최일흥;이상윤;황동환;이상정;박장수
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.365-374
    • /
    • 2004
  • The relay measures the frequency of the power system in order to detect faults and separate them from the system. Many estimation algorithms for the relay have been proposed to accurately measure the frequency. This paper proposes a new frequency measurement method using the digital phase locked-loop(DPLL) for the relay of the power system. The proposed method is configured with a DPLL scheme and verified through computer simulations and experimental tests. In order to cope with noises in the power system, filters are included in the input signal processing part and the frequency comparator. MATLAB is used for computer simulations and an experimental setup with a CPU and an FPGA(Field Programmable Gate Array) is constructed. The loop filter of the DPLL is run in the CPU software In adjust parameters and others are in the FPGA. Experimental tests are performed lot a function generator and the power system. Results show that the proposed method is appropriate to the frequency measurement for the relay.

An Experimental Study on Operation Setting Optimization of Circuit Breaker for Improving Safety on DC Railroad Feeder System (직류철도 급전계통의 안전성 향상을 위한 차단기 동작 최적 설정의 실험적 고찰)

  • Lee, Jae-Bong;Jung, No-Geon;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.526-531
    • /
    • 2016
  • This paper presents an experimental study on the optimal settings for the selected DC fault relay (50F) to improve the operating performance for the high-speed circuit breaker on DC feeding system which ensure safety within rolling stock maintenance depot. In this study, current supplied to overhead contact wire was calculated on 1 ms interval to analyze the correction values of DC fault selective relay for the operation of current supply cutout. Particularly, standards for the accurate detection of accidents between an electric railway vehicle and the electric power facilities are shown by investigating the optimal correction values for detection of fault current, and the results indicated that it takes about 213 ms for the DC fault selective relay(50F) to fully open. In the future, the correction values of DC fault selective relay suggested in this paper will be used as the reference values of protective relay for the safe operation of DC electric railroad system such as urban railway.

A Study on the Overcurrent Relay Coordination in Power Systems (전력계통에서의 과전류계전기 보호협조에 관한 연구)

  • Choi, Hong-Kyoo;Kim, Kyung-Chul;Oh, Jung-Suk;Kim, Byung-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.351-358
    • /
    • 2004
  • When fault occur in power systems, the protective relay plays a roles of protecting power system according to its setting values. There, it is very important that the protective relay have high selectivity performance in power system by correct setting the relays. This paper analyzed protect device protect cooperation or Transient stability and apply to Overcurrent relay in the real power system operation environment by using EDSA Program.

  • PDF