Quality Assurance and Quality Control method for Volatile Organic Compounds measured in the Photochemical Assessment Monitoring Station (광화학측정망에서 측정한 휘발성유기화합물의 정도관리 방법)

  • Shin, Hye-Jung;Kim, Jong-Choon;Kim, Yong-Pyo
    • Particle and aerosol research
    • /
    • v.7 no.1
    • /
    • pp.31-44
    • /
    • 2011
  • The hourly volatile organic compounds(VOCs) concentrations between 2005 and 2008 at Bulgwang photochemical assessment monitoring station were investigated to establish a method for quality assurance and quality control(QA/QC) procedure. Systematic error, erratic error, and random error, which was manifested by outlier and highly fluctuated data, were checked and removed. About 17.3% of the raw data were excluded according to the proposed QA/QC procedure. After QA/QC, relative standard deviation for representing 15 species concentrations decreased from 94.7-548.0% to 63.4-125.8%, implying the QA/QC procedure is proper. For further evaluation about the adequacy of QA/QC procedure, principal components analysis(PCA) was carried out. When the data after QA/QC procedure was used for PCA, the extracted principal components were different from the result from the raw data and could logically explain the major emission sources(gasoline vapor, vehicle exhaust, and solvent usage). The QA/QC procedure based on the concept of errors is inferred to proper to be applied on VOCs. However, an additional QA/QC step considering the relationship between species in the atmosphere needs to be further considered.

A Study on the Performance Evaluation of Standard Gamma Irradiation System Using Monte Carlo Code (몬테카를로 코드를 활용한 표준 감마선 조사장치의 성능평가에 관한 연구)

  • Park, Won-Seok;Heo, Seung-Uk;Kim, Jang-Oh;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.179-184
    • /
    • 2018
  • In this study, we compared the measured values of the effective beam size of standard gamma irradiator with the simulation results to provide a useful means to the effective beam area determination. Results of the simulation and measured using ion chamber was distributed in a relative error of 4.5 ~ 7.3% of the case of air kerma rate. The size of the effective beam area is when the simulation was implemented in the horizontal direction 27cm, 21.6cm vertical direction, the measured result using a film was obtained similar results with the horizontal direction 26.5cm, 21.9cm vertical direction. The relative error in the horizontal direction is 1.85% and 1.38% vertical effective beam area was also similarly distributed around the field gamma rays. As a result of the study, it was confirmed that the effectiveness of the simulation was sufficient for the gamma irradiation system. In particular, it is small relative errors in the effective beam size than the air kerma rate is considered to be due to the size of the beam is determined by geometric factors rather than the capacity of the standard source. A further study is needed to improve the reliability of the photon energy distribution diagram using simulation.

Quality Control of Asbestos Fiber Counting for Airborne Samples Using Phase Contrast Microscopy (위상차 현미경법을 이용한 공기중 석면농도 분석에서의 정도관리)

  • Kang, Bo Young;Shin, Yong Chul;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.221-237
    • /
    • 1991
  • This study was conducted to evaluate the accuracy and the precision of asbestos counting data produced by the Division of Industrial Health, School of Public Health, Seoul National Universitys (SNU). The study was performed from July 18 to October 4, 1991, and the results are summarized as follows. 1. Intracounter Relative Standard Deviations (Sr) in the category of 5-50.5 fibers as total fibers counted ranged from 0.27 to 0.37, which were greater than 0.10-0.17 which were reported by the NIOSH. The reasons are supposed to be as follows. First, inexperience of counters in asbestos fiber counting was considered to be a main reason. Second, poor quality of samples due to sampling and mounting error increased variation of counting. Third, fiber density of many samples were less than $100fibers/mm^2$. But Intracounter Relative Standard Deviations (Sr) in samples with >50.5 fibers ranged from 0.l6 to 0.20, approaching the value 01 NIOSH. 2. Intralaboratory Relative Standard Deviations (Sr) in categories of 5-20.5, >20.5-50.5 and >50.5 fibers were 0.54, 0.37 and 0.26, respectively. Intralaboratory Sr in samples with fiber density greater than $100fibers/mm^2$ was 0.26. This was similar to the values reported by other foreign experienced laboratories. 3. Comparing results of three counters, Counter C, a beginner, overestimated asbestos fiber concentrations. 4. Since our SNU laboratory has participated in two quality control programs, IOMA-F.R.I.C.A., U.K. and NIOSH PAT Program, U.S.A., this laboratory has been evaluated as " Rating 1" and "Proficient" laboratory, by IOM and NIOSH, respectively.

  • PDF

A Comparative Study on Lowflow Quantiles Estimation in Han River Basin (한강유역의 확률갈수량 추정기법 비교연구)

  • Kim, Kyung-Duk;Kim, Don-Soo;Heo, Jun-Haeng;Kim, Kyu-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.2
    • /
    • pp.315-324
    • /
    • 2003
  • Stream flow data was analyzed for determining the lowflow which is the standard for river maintenance flow. Lowflow quantiles were estimated based on the parametric and nonparametric methods and two methods were compared by Monte Carlo simulation study. As the results of the parametric method, three probability distributions such as gamma-2, lognormal-2 and Weibull-2, are selected as appropriate models for stream flow data of 13 stations in Han River Basins. According to simulation results, relative bias (RBIAS) and relative root mean square error (RRMSE) of the lowflow quantiles are the smallest when the applied and population models are the same. The fame statistical properties from the nonparametric models are good within the interpolation range. Among 7 bandwidth selectors used in this study, the RRMSEs of the Park and Marron method (PM) are the smallest while those of the Shoaler and Jones method (SJ) are the largest.

Influence of Diverse Atmospheric Conditions on Optical Properties of a Pulse Laser in a Time-of-Flight Laser Range Finder

  • Shim, Young Bo;Kwon, Oh-Jang;Choi, Hyun-Yong;Han, Young-Geun
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • We investigate the propagation characteristics of a pulse laser in a time-of-flight laser range finder (TOF-LRF) system with variations in atmospheric conditions, such as temperature, pressure, relative humidity, and the concentration of $CO_2$. The measurement error of distance related with the group velocity change in the TOF-LRF system is analyzed by considering the refractive index of the standard atmosphere with variations in atmospheric conditions. The dependence of the pulse width broadening induced by chromatic dispersion of the standard atmosphere on the operating wavelength and the initial pulse width of the light sources is discussed. The transmission of air with variations in the relative humidity or the concentration of $CO_2$ is analyzed by using different values of absorption coefficients depending on the operation wavelength of the light source in the TOF-LRF system.

Determination of Trace Elements in Airborne Particulates by Instrumental Neutron Activation Analysis (중성자 방사화분석법을 이용한 대기분진시료의 정량)

  • Chung, Yong-Sam;Chung, Young-Ju;Jeong, Eui-Sik;Cho, Seung-Yeon
    • Nuclear Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.234-247
    • /
    • 1995
  • Trace elements in airborne particulates were analyzed by instrumental neutron activation analysis (INAA) under the optimum analytical condition. Neutron irradiation for sample was done at the irradiation hole(neutron flux 1$\times$10$^{13}$ n/$\textrm{cm}^2$.s) of TRIGA MARK-III research reactor in the Korea Atomic Energy Research Institute. For the verification of the analytical method, NIST SRM-1648 and NIES CRM No.8 ore chosen and analyzed. The accuracy and precision of the analysis of 40 and 24 trace elements in the samples were compared with the certified and reported values, respectively. The analytical method was found to be reliable enough when the analytical data of NIES sample were compared with those of different counties. In the analytical result of two or both of standard reference materials, relative standard deviation wes within the 15% except a few elements and the relative error was within the 10%. We used this method to analyze 30 trace elements in airborne particulates collected with the high volume air sampler(PM-10) at too different locations and also confirmed the possibility to use this method as a routine monitoring tool to find out environmental pollution sources.

  • PDF

Dimension Measurement of Nuclear Fuel Rods Using an Image Processing Technology (영상처리기술에 의한 핵연료봉의 제원 측정)

  • Koo, D.S.;Min, D.K.;You, G.S.;Shin, H.S.;Hong, K.P.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.2
    • /
    • pp.79-84
    • /
    • 1999
  • An image processing technology was developed to measure the dimension of nuclear fuel rods and the diameter of nuclear fuel rods was measured by this method. It was confirmed that parameters such as camera-to-specimen distance. camera location, light intensity and light characteristic would affect dimension measurement of nuclear fuel rods. The percent relative error and percent standard deviation of measuring the diameter of nuclear fuel rods using image processing method were 4.88%, ${\pm}3.34%$ while the percent relative error and percent standard deviation using conventional method were 12.7%, ${\pm}9.72%$, respectively. The accuracy of diameter measurement of nuclear fuel rods using image processing method was about 3 times as high as that using conventional method.

  • PDF

Non-invasive hematocrit measurement (혈액중 non-invasive hematocrit 분석)

  • Yoon, Gil-Won;Jeon, Kye-Jin;Park, Kun-Kook;Lee, Jong-Youn;Hwang, Hyun-Tae;Yeo, Hyung-Seok;Kim, Hong-Sig
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2002.11a
    • /
    • pp.59-62
    • /
    • 2002
  • Wavelength selection and prediction algorithm for determining hematocrit are investigated. A model based on the difference in optical density induced by the pulsation of heart beat is developed by taking approximation of Twersky's theory on the assumption that the variation of blood vessel size is small during arterial pulsing[1]. A device is constructed with a five-wavelength LED array as light source. The selected wavelengths are two isobestic points and three in compensation for tissue scattering. Data are collected from 549 out-patients who are randomly grouped as calibration and prediction sets. The range of percent hematocrit was 19.3∼51.8. The ratio of the variations of optical density between systole and diastole at two different wavelengths is used as a variable. We selected several such variables that show high reproducibility among all variables. Multiple linear regression analysis is made. The relative percent error is 8% and the standard deviation is 3.67 for the calibration set. The relative % error and standard deviation of the prediction set are 8.2% and 3.69 respectively. We successfully demonstrate the possibility of non-invasive hematocrit measurement, particularly, using the wavelengths below 1000nm.

  • PDF

Heat Transfer Model for Soil Irradiated by Infrared (적외선 조사된 토양에 대한 열전달 모델)

  • 강화석;이귀현;강위수;오재헌
    • Journal of Biosystems Engineering
    • /
    • v.21 no.4
    • /
    • pp.449-455
    • /
    • 1996
  • The temperature distributions at various soil depths were predicted by heat transfer model during and after infrared irradiation on sand loam or loam soil. At each soil depth, predicted and measured temperature distributions were compared with using the mean relative percentage deviation and standard error. The mean relative percentage deviation was less than 10% between predicted and measured temperature distributions at each soil depth. Thus, it was concluded that the temperature distribution at each soil depth could be predicted satisfactorily by heat transfer model. Also, it is expected that these predicted temperature distributions can be used as basic information for determining the working speed of weeder and the size when the real weeder is constructed.

  • PDF

Determining the Relative Weights of Bias and Variance in Dual Response Surface Optimization (쌍대반응표면 최적화에서 편차와 분산의 가중치 결정에 관한 연구)

  • Jeong, In-Jun;Kim, Gwang-Jae;Jang, Su-Yeong;Lin, Dennis K.J.
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2004.05a
    • /
    • pp.294-297
    • /
    • 2004
  • Mean squared error (MSE) is an effective criterion to combine the mean and the standard deviation responses in dual response surface optimization. The bias and variance components of MSE need to be weighted properly in the given problem situation. This paper proposes a systematic method to determine the relative weights of bias and variance in accordance with a decision maker's prior and posterior preference structure.

  • PDF