• 제목/요약/키워드: relative comparison density

검색결과 98건 처리시간 0.031초

Comparative efficacy of photo-activated disinfection and calcium hydroxide for disinfection of remaining carious dentin in deep cavities: a clinical study

  • Sharma, Sidhartha;Logani, Ajay;Shah, Naseem
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.195-200
    • /
    • 2014
  • Objectives: To comparatively evaluate the efficacy of photo-activated disinfection (PAD), calcium hydroxide (CH) and their combination on the treatment outcome of indirect pulp treatment (IPT). Materials and Methods: Institutional ethical clearance and informed consent of the patients were taken. The study was also registered with clinical registry of India. Sixty permanent molars exhibiting deep occlusal carious lesion in patients with the age range of 18 - 22 yr were included. Clinical and radiographic evaluation and set inclusion and exclusion criteria's were followed. Gross caries excavation was accomplished. In group I (n = 20) PAD was applied for sixty seconds. In group II (n = 20), CH was applied to the remaining carious dentin, while in group III (n = 20), PAD application was followed by CH placement. The teeth were permanently restored. They were clinically and radiographically followed-up at 45 day, 6 mon and 12 mon. Relative density of the remaining affected dentin was measured by 'Radiovisiography (RVG) densitometric' analysis. Results: Successful outcome with an increase in radiographic grey values were observed in all three groups. However, on inter-group comparison, this change was not significant (p > 0.05). Conclusions: PAD and CH both have equal disinfection efficacy in the treatment of deep carious dentin. PAD alone is as effective for treatment of deep carious lesion as calcium hydroxide and hence can be used as an alternative to CH. They can be used independently in IPT, since combining both does not offer any additional therapeutic benefits.

Operational modal analysis of Canton Tower by a fast frequency domain Bayesian method

  • Zhang, Feng-Liang;Ni, Yi-Qing;Ni, Yan-Chun;Wang, You-Wu
    • Smart Structures and Systems
    • /
    • 제17권2호
    • /
    • pp.209-230
    • /
    • 2016
  • The Canton Tower is a high-rise slender structure with a height of 610 m. A structural health monitoring system has been instrumented on the structure, by which data is continuously monitored. This paper presents an investigation on the identified modal properties of the Canton Tower using ambient vibration data collected during a whole day (24 hours). A recently developed Fast Bayesian FFT method is utilized for operational modal analysis on the basis of the measured acceleration data. The approach views modal identification as an inference problem where probability is used as a measure for the relative plausibility of outcomes given a model of the structure and measured data. Focusing on the first several modes, the modal properties of this supertall slender structure are identified on non-overlapping time windows during the whole day under normal wind speed. With the identified modal parameters and the associated posterior uncertainty, the distribution of the modal parameters in the future is predicted and assessed. By defining the modal root-mean-square value in terms of the power spectral density of modal force identified, the identified natural frequencies and damping ratios versus the vibration amplitude are investigated with the associated posterior uncertainty considered. Meanwhile, the correlations between modal parameters and temperature, modal parameters and wind speed are studied. For comparison purpose, the frequency domain decomposition (FDD) method is also utilized to identify the modal parameters. The identified results obtained by the Bayesian method, the FDD method and a finite element model are compared and discussed.

모래지반에 타입된 개단말뚝의 관내토지지력 산정 (Computation of Plug Capacity for Open -Ended Piles Driven into Sands)

  • 백규호;이승래
    • 한국지반공학회지:지반
    • /
    • 제9권4호
    • /
    • pp.7-16
    • /
    • 1993
  • 지반조건이 관내토의 지지력특성에 미치는 영향을 알아보기 위하여 여러가지 조건을 갖는 모래지반에 타입된 개단말뚝에 대하여 토조실험을 수행하였다. 실험에서 사용된 모형말뚝은 말뚝의 지지력을 외주면마찰력과 관내토지지력, 그리고 말뚝 단면부지지력의 세가지로 분리 측정할 수 있도록 제작하였다. 몇가지 가정하에 실험결과로부터 계산된 관내토 내부의 토압계수는 말뚝의 관입깊이와 지반의 상대밀도가 증가함에 따라 감소하고, 지반의 초기 압밀압력이 증가할수록 증가하는 경향을 나타낸다. 또한 토압계수는 관내토의 하단부에 접근할수록 증가한다. 관내토의 1차원 해석으로부터 계산된 관내토지지력과 실측치의 비교로부터 Randolph등과 O'Neill등에 의하여 제안된 P를 이용한 1차원 해석이나 API의 추천방법은 관내토지지력을 상당히 과소평가 함을 알 수 있다. 따라서 실험결과에 근거하여 관내토의 1차원 해석을 통한 관내토지지력의 예측 정도를 높이기 위하여 1차원 해석에 필요한 관내토의 토압계수를 산정할 수 있는 경험식이 제안되었으며, 제안된 식은 모든 지반조건에 대하여 적당한 관내토지지력을 산정한다.

  • PDF

고분자전해질연료전지에서 수소투과도 측정법의 비교 (Comparison of Measurement Method of Hydrogen Permeability in Proton Exchange Membrane Fuel Cell)

  • 오소형;윤재원;이대웅;박권필
    • Korean Chemical Engineering Research
    • /
    • 제57권4호
    • /
    • pp.507-511
    • /
    • 2019
  • 고분자전해질 연료전지(PEMFC)의 고분자막 내구성을 평가하는데 수소투과도가 많이 사용되고 있다. 수소투과도를 쉽게 측정하는 방법으로 선형 주사 전압 측정법(Linear Sweep Voltammetry, LSV)이 주로 사용된다. 연구자마다 LSV 측정 방법에 차이가 있어 연구 결과를 비교하기가 어려울 때가 많다. 그래서 본 연구에서는 측정하기 어렵지만 정확한 값이라고 할 수 있는 기체 크로마토그래프에 의한 수소투과도와 DOE와 NEDO의 LSV 방법을 비교하여 정확성을 확인하고자 하였다. 온도와 상대습도를 변화시키며 수소투과도를 측정해 비교했을 때, DOE LSV 방법이 GC 방법과 비교해 오차 범위 5%이하의 정확성을 보였다. NEDO LSV 방법은 DOE방법과 같이 0.3V의 전류 값으로 수소투과전류밀도를 결정했을 때 오차는 감소하였다.

비닐스트립-시멘트로 보강된 느슨한 중간 모래의 정규화 전단탄성계수 및 감쇠비 곡선 산정식 제안 (Proposal of Predictive Equations of Normalized Shear Modulus and Damping Ratio Curves for Loose Medium Sand Reinforced by Vinyl Strip-cement)

  • 김종민
    • 한국지반공학회논문집
    • /
    • 제37권12호
    • /
    • pp.33-45
    • /
    • 2021
  • 본 연구에서는 비닐스트립-시멘트로 보강된 느슨한 중간 모래의 정규화 전단탄성계수 및 감쇠비 산정식을 제안하였다. 상대밀도 40%의 모래시편을 다양한 비닐스트립 혼합비(0.0, 0.1, 0.3, 0.4%)와 시멘트 혼합비(0, 1, 2%)로 보강한 후 15, 30, 60kPa의 구속압조건에서 수행한 공진주시험 자료(Yu, et al., 2018)를 분석하여 정규화 전단탄성계수와 감쇠비 산정식을 보강조건과 구속압조건의 함수로 제안하였다. 제안된 산정식을 적용한 결과와 시험결과를 비교한 결과 결정계수 0.9 이상의 높은 신뢰도를 보여주었다. 본 연구에서 제안된 산정식을 이용하면 비닐스트립-시멘트로 보강된 느슨한 중간모래의 전단탄성계수와 감쇠비를 공진주시험 수행없이 간단히 산정할 수 있어 시간과 비용이 절감될 것으로 기대한다.

Comparison of Meat Quality and Muscle Fiber Characteristics between Porcine Skeletal Muscles with Different Architectures

  • Park, Junyoung;Song, Sumin;Cheng, Huilin;Im, Choeun;Jung, Eun-Young;Moon, Sung Sil;Choi, Jungseok;Hur, Sun Jin;Joo, Seon-Tea;Kim, Gap-Don
    • 한국축산식품학회지
    • /
    • 제42권5호
    • /
    • pp.874-888
    • /
    • 2022
  • This study aimed to compare the similarities, physicochemical properties, and muscle fiber characteristics of porcine skeletal muscles. Fourteen types of muscles were collected from nine pig carcasses at 24 h post-mortem and classified by muscle architecture into two main groups, namely parallel and pennate. The muscles were further differentiated into three subtypes per group. These included fan-shaped, fusiform, and strap for the parallel group, and unipennate, bipennate, and multipennate for the pennate group. Parallel-fibered muscles, which were composed of larger I, IIA, IIX, and IIXB fibers and a lower density of IIA fibers, showed higher redness and yellowness values than pennate-fibered muscles (p<0.05). However, the relative fiber area was not significantly different between the parallel and pennate groups (p>0.05). In the subtypes of parallel architecture, the strap group showed lower moisture content and higher redness values than the other subtypes and had considerably higher amounts of oxidative fibers (I and IIA; 72.3%) than the fan-shaped and fusiform groups (p<0.05). In the pennate group, unipennate showed comparatively lower moisture content and higher lightness than other pennate subtypes and was composed of smaller I, IIA, and IIX fibers than the bipennate and multipennate groups (p<0.05). Finally, a different trend of muscle clustering by hierarchical cluster analysis was found between physicochemical properties and muscle fiber characteristics. These results suggest that the physicochemical properties and muscle fiber characteristics of porcine skeletal muscles are not significantly dependent on morphological properties but are rather related to the intrinsic properties of the individual muscles.

ANN 및 SVM을 사용하여 투과 유량을 예측하는 동적 막 여과 공정 모델링 (Modeling of a Dynamic Membrane Filtration Process Using ANN and SVM to Predict the Permeate Flux)

  • 수피안 라데그;모하메드 무사우이;마마르 라이디;나지 물라이-모스테파
    • 멤브레인
    • /
    • 제33권1호
    • /
    • pp.34-45
    • /
    • 2023
  • 본 연구에서는 투과 유량 모델을 개발하기 위하여, 시간, 막 전후의 압력 차, 회전 속도, 막의 기공 크기, 동점도, 농도 및 공급 유체의 밀도 등 7개의 입력 변수에 기반한 두 종류(ANN 및 SVM) 인공지능 기법을 이용하였다. 시행착오법과 실험데이터와 예측 데이터 간의 결정 계수(R2) 와 평균절대상대편차(AARD)를 포함한 두 가지 통계 변수를 통해 최적의 모델을 선정하였다. 최종적으로 얻어진 결과에서 최적화된 ANN 모델이 R2 = 0.999 및 AARD% = 2.245인 투과 플럭스 예측 정확도를 보여서, R2 = 0.996 및 AARD% = 4.09의 정확도를 보인 SVM 모델에 비해 더 정확함을 알 수 있었다. 또한, ANN 모델은 SVM 방식에 비해 투과 유속을 예측하는 능력도 더 높은 것으로 나타났다.

선상안전교육 시 선내 연기충진 여부에 따른 실습생의 피난이동특성 비교 (A Comparison of the Trainees' Evacuation Characteristics according to the Indoor Smoke-fullfill during the Safety Training on Ship)

  • 황광일;조익순;윤귀호;김별
    • 해양환경안전학회지
    • /
    • 제24권4호
    • /
    • pp.422-429
    • /
    • 2018
  • 본 연구는 선박에서 발생할 수 있는 화재연기의 위험성을 인식시키고 비상대응능력을 향상시키기 위해 선내에 안전교육을 위한 환경을 구축하고 시나리오를 개발 운영하면서 획득한 실습생의 상황별 이동특성을 측정분석한 것으로, 그 결과를 정리하면 다음과 같다. 연기가 없는 조건에서는 익숙한 이동경로에 장애가 발생한 경우와 그렇지 않은 경우의 각 피난이동 상대속도 사이에 차이가 없지만, 실내에 연기가 충진되어 가시도가 매우 낮은 조건에서는 시야불량에 따른 이동능력 저하로 인해 그렇지 않은 경우에 비해 평균상당속도가 62.5 % 감속되었다. 시나리오에 관계없이 단순이동경로에 비해 복잡이동경로의 평균 상당속도가 빠르고 표준편차도 작게 나타났다. 연기가 충진된 경우에 대한 단순 데이터 평가에서는 전체이동경로와 복잡이동경로의 상대속도 확률분포가 매우 유사하였지만, 전체이동경로의 상대속도에 대한 복잡이동경로의 상대속도비율의 개인간 변동폭은 매우 컸다. 한편, 상당속도는 가시거리의 로그함수로 표현할 수 있었다. 또한 실습생의 긴장감이 증가하면서 모든 경로에서 상대속도가 빨라졌다.

말뚝형태 및 지반조건에 따른 현장타설말뚝의 수평지지력 평가 (Evaluation of Lateral Load Capacity of Drilled Shafts with Pile Shape and Soil Conditions)

  • 이준환;백규호;김대홍;황성욱;김민기
    • 한국지반공학회논문집
    • /
    • 제23권2호
    • /
    • pp.61-69
    • /
    • 2007
  • 본 연구에서는 현장타설말뚝을 대상으로 지반조건 및 말뚝형태에 따른 수평지지력과 수평거동에 대하여 실험적 분석을 실시하였다. 이를 위해 가압토조실험을 수행하였으며 상대밀도와 지반응력의 변화를 고려하여 원통형과 테이퍼형 말뚝에 대해 재하시험을 수행하였다. 토조실험결과, 수직응력과 수평응력은 모두 말뚝의 수평거동 및 극한수평 지지력에 영향을 나타내는 것으로 관찰되고 있으나, 수평응력의 영향이 보다 더 크게 작용하고 있음을 알 수 있다. 상대밀도 또한 수평거동 및 지지력에 상당한 영향을 미치고 있는 것으로 나타나고 있었다. 수평거동에 대한 말뚝형태의 영향은 지반상태에 따라 다소간의 차이가 보이고 있으나, 전반적으로 지반응렬이나 상대밀도와 같은 지반특성치에 의한 영향에 비해서는 작게 나타나고 있었다. 기존 예측식을 이용한 비교분석 결과, 기존의 예측식에 의해 산정된 결과는 실측된 결과와 상당한 차이를 보이고 있었으며, 이는 지지력 산정시 수평응력의 변화량이 고려되어 있지 않았기 때문임을 알 수 있었다.

New Method for Combined Quantitative Assessment of Air-Trapping and Emphysema on Chest Computed Tomography in Chronic Obstructive Pulmonary Disease: Comparison with Parametric Response Mapping

  • Hye Jeon Hwang;Joon Beom Seo;Sang Min Lee;Namkug Kim;Jaeyoun Yi;Jae Seung Lee;Sei Won Lee;Yeon-Mok Oh;Sang-Do Lee
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1719-1729
    • /
    • 2021
  • Objective: Emphysema and small-airway disease are the two major components of chronic obstructive pulmonary disease (COPD). We propose a novel method of quantitative computed tomography (CT) emphysema air-trapping composite (EAtC) mapping to assess each COPD component. We analyzed the potential use of this method for assessing lung function in patients with COPD. Materials and Methods: A total of 584 patients with COPD underwent inspiration and expiration CTs. Using pairwise analysis of inspiration and expiration CTs with non-rigid registration, EAtC mapping classified lung parenchyma into three areas: Normal, functional air trapping (fAT), and emphysema (Emph). We defined fAT as the area with a density change of less than 60 Hounsfield units (HU) between inspiration and expiration CTs among areas with a density less than -856 HU on inspiration CT. The volume fraction of each area was compared with clinical parameters and pulmonary function tests (PFTs). The results were compared with those of parametric response mapping (PRM) analysis. Results: The relative volumes of the EAtC classes differed according to the Global Initiative for Chronic Obstructive Lung Disease stages (p < 0.001). Each class showed moderate correlations with forced expiratory volume in 1 second (FEV1) and FEV1/forced vital capacity (FVC) (r = -0.659-0.674, p < 0.001). Both fAT and Emph were significant predictors of FEV1 and FEV1/FVC (R2 = 0.352 and 0.488, respectively; p < 0.001). fAT was a significant predictor of mean forced expiratory flow between 25% and 75% and residual volume/total vital capacity (R2 = 0.264 and 0.233, respectively; p < 0.001), while Emph and age were significant predictors of carbon monoxide diffusing capacity (R2 = 0.303; p < 0.001). fAT showed better correlations with PFTs than with small-airway disease on PRM. Conclusion: The proposed quantitative CT EAtC mapping provides comprehensive lung functional information on each disease component of COPD, which may serve as an imaging biomarker of lung function.