• Title/Summary/Keyword: relative boundary conditions

Search Result 134, Processing Time 0.024 seconds

Analysis of the Electromagnetic Scattering by a Resistive Strip Grating Tapered Resistivity On a Grounded Dielectric Plane -from Zeores at One Edge to Infinite at the Other Edge- (접지된 유전체층 위에 변하는 저항율을 갖는 저항띠 격자구조에서의 전자파산란 해석 -한쪽 모서리에서 0이고 다른쪽 모서리로 가면서 무한대로 변하는 경우-)

  • Yoon, Uei-Joong
    • The Journal of Information Technology
    • /
    • v.8 no.2
    • /
    • pp.77-84
    • /
    • 2005
  • In this paper, electromagnetic scattering problems by a resistive strip grating with tapered resistivity on a grounded dielectric plane according to strip width and spacing, relative permittivity and thickness of dielectric layers, and incident angles of a electric wave are analyzed by applying the Fourier-Galerkin Moment Method known as a numerical procedure. The boundary conditions are applied to obtain the unknown field coefficients and the resistive boundary condition is used for the relationship between the tangential electric field and the electric current density on the strip. The resistivity of resistive strips in this paper varies from zeroes at one edge to infinite at the other edge, then the induced surface current density on the resistive strip is expanded in a series of Jacobi polynomials of the order ${\alpha}=0.2,\;{\beta}=-0.2$ as a orthogonal polynomials. The numerical results of the geometrically normalized reflected power in this paper are compared with those for the existing perfectly conducting strip. The numerical results of the normalized reflected power for conductive strips case with zero resistivity in this paper show in good agreement with those of existing papers.

  • PDF

A Study on the Fundamental Surge Frequencies in Multi-Stage Axial Flow Compressor Systems

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.7 no.4
    • /
    • pp.160-173
    • /
    • 2014
  • Surge phenomena in multi-stage axial flow compressors were studied with attention to the frequency behaviors. A new parameter "volume-modified reduced surge frequency" was introduced, which took into consideration the essential surge process, i.e., emptying and filling of the working gas in the delivery plenum. The behaviors of the relative surge frequencies at the stall stagnation boundaries, compared with the corresponding duct resonance frequencies, have demonstrated the existence of two types of surges; i.e., a near-resonant surge and a subharmonic surge. The former, which has fundamentally a near-resonance frequency, occurs predominantly at the stall stagnation boundary for the short -and-fat plenum delivery flow-path and the long-and-narrow delivery duct flow-path, and possibly in the intermediate conditions. The latter, which has a subharmonic frequency of the fundamental near-resonant one and occurs mainly in the intermediate zone, is considered to be caused by the reduced frequency restricted to a limited range. In relation with those dimensionless frequencies at the stall stagnation boundary, the surge frequency behaviors in more general situations away from the boundaries could be estimated, though very roughly.

A Comparison between EFIU and HEIU Schemes in ADI-FDTD Simulations (ADI-FDTD 해석에서의 EFIU와 HFIU 계산 방법 비교 연구)

  • Ju Sae-Hoon;Lee Kyung-Hoon;Hwang In-Ho;Kim Hyeong-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.1 s.104
    • /
    • pp.8-16
    • /
    • 2006
  • In this paper, updating schemes for the alternating-direction implicit finite-difference time-domain method(ADI-FDTD) are studied, which method has the potential to considerably reduce the number of time iterations especially in case where the fine spatial lattice relative to the wavelength is used to resolve fine geometrical features. In numerical simulations for microwave structure using ADI-FDTD, time marching scheme comprises of two sub-iterations. Two different updating equation sets for ADI-FDTD simulations are presented. In order to discuss the characteristics of those schemes especially in view of applying boundary conditions, we solved two complementary 2-D problems.

Bulk Flow Pulsations and Film Cooling from Two Rows of Staggered Holes : Effect of Blowing Ratios (주유동의 맥동과 엇갈린 2열 분사홀로부터의 막냉각 : 분사비의 영향)

  • Sohn, Dong Kee;Lee, Joon Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.9
    • /
    • pp.1195-1207
    • /
    • 1998
  • Periodic pulsations in the static pressure near turbine surfaces as blade rows move relative to each other is one of the important sources of turbine unsteadiness. The present experiment aims to investigate the effect of the static pressure pulsations on the interaction of film coolant flows from two rows of staggered holes with mainstream and its effect on film cooling heat transfer. Potential flow pulsations are generated by the rotating shutter mechanism installed downstream of the test section, The free-stream Strouhal number based on the boundary layer thickness is in the range of 0.033 - 0.33, and the amplitude of about 10-20%. Measured are time-averaged and phase-averaged velocity variations, pressure variations and temperature distributions of the flow field. Experimental conditions are identified by boundary layer measurements. Injectant behavior is characterized by the measurements of unsteady pressure in the plenum chamber and free-stream static pressure. The film cooling effectiveness is evaluated from the insulated wall temperature measurement. It has been found that bulk flow pulsation provides very large diffusion of the injectants and the effectiveness is significantly reduced by the flow pulsations.

LINEAR INSTABILITY ANALYSIS OF A WATER SHEET TRAILING FROM A WET SPACER GRID IN A ROD BUNDLE

  • Kang, Han-Ok;Cheung, Fan-Bill
    • Nuclear Engineering and Technology
    • /
    • v.45 no.7
    • /
    • pp.895-910
    • /
    • 2013
  • The reflood test data from the rod bundle heat transfer (RBHT) test facility showed that the grids in the upper portion of the rod bundle could become wet well before the arrival of the quench front and that the sizes of liquid droplets downstream of a wet grid could not be predicted by the droplet breakup models for a dry grid. To investigate the water droplet generation from a wet grid spacer, a viscous linear temporal instability model of the water sheet issuing from the trailing edge of the grid with the surrounding steam up-flow is developed in this study. The Orr-Sommerfeld equations along with appropriate boundary conditions for the flow are solved using Chebyshev series expansions and the Tau-Galerkin projection method. The effects of several physical parameters on the water sheet oscillation are studied by determining the variation of the temporal growth rate with the wavenumber. It is found that a larger relative steam velocity to water velocity has a tendency to destabilize the water sheet with increased dynamic pressure. On the other hand, a larger ratio of steam boundary layer to the half water sheet thickness has a stabilizing effect on the water sheet oscillation. Droplet diameters downstream of the spacer grid predicted by the present model are found to compare reasonably well with the data obtained at the RBHT test facility as well as with other data recently reported in the literature.

Analysis of the Electromagnetic Scattering by Conducting Strip Gratings with 2 Dielectric Layers (접지평면위에 2개의 유전체층을 가지는 도체띠 격자구조에서의 전자파산란 해석)

  • 김용연;방성일
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.4 no.1
    • /
    • pp.102-109
    • /
    • 1999
  • In this paper, Electromagnetic scattering problem by a perfectly conducting strip grating with 2 dielectric layer on a grounded plane by incidence of a electric wave is analyzed by applying the PMM (Point Matching Method) known as a simple procedure. The scattered electromagnetic fields are expanded in a series of Floquet mode functions. The boundary conditions are applied to obtain the unknown field coefficients and the conducting boundary condition is used for the relationship between the tangential electric field and the electric current density on the strip When the incident angle is normal incidence the minimum value of the geometrically normalized reflected power according as relative permittivity is increased it should be noted that the value of the strip width gets moved toward high value. Them most energy by a normal incident wave is scattered in direction of the other angles except normal incident angle.

  • PDF

Wind tunnel study of plume dispersion with varying source emission configurations

  • Wittwer, Adrian R.;Loredo-Souza, Acir M.;Schettini, Edith B. Camano;Castro, Hugo G.
    • Wind and Structures
    • /
    • v.27 no.6
    • /
    • pp.417-430
    • /
    • 2018
  • The concentration fields in the proximities of a local gas emission source are experimentally analyzed in several combinations of wind incidences and source emissions. These conditions are determined by the plume buoyancy, emission velocity and incident flow wind speed. Concentration measurements are performed by an aspirating probe in a boundary layer wind tunnel. The analysis included the mean concentration values and the intensity of concentration fluctuations in a neutral atmospheric boundary layer flow. Different configurations are tested: an isolated stack in a homogeneous terrain and a stack with a bluff body in close proximity, located windward and leeward from the emission source. The experimental mean concentration values are contrasted with Gaussian profiles and the dilution factor is analyzed with respect to the empirical curves of the minimum dilution. Finally, a study on the plume intermittency is performed in a cross-sectional plane near the emission source. It is possible to highlight the following observations: a) plume vertical asymmetry in the case of an isolated emission source, b) significant differences in the dispersion process related to the relative location of the emission source and bluff body effects, and c) different probabilistic behavior of the concentration fluctuation data in a cross-sectional measurement plane inside the plume.

Solution of TM Scattering Applying FGMM and PMM for Resistive Strip Grating Between a Grounded Double Dielectric Layer (접지된 2중 유전체층 사이의 저항띠 격자에 대해 FGMM과 PMM을 적용한 TM 산란 해)

  • Uei-Joong Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.3
    • /
    • pp.77-82
    • /
    • 2023
  • In this paper, TM(tranverse magnetic) electromagnetic scattering problems for resitive strip grating between grounded double dielectric layers are analyzed by using the FGMM(fourier galerkin moment method) and PMM(point matching method) known as a numerical method of electromagnetic field. The boundary conditions are applied to obtain the unknown field coefficients, the resistive boundary condition is applied to analysis of resistive strip. Overall, when the unoform resistivity decreased, the magnitude of the current density induced in the resistive strip increased, and the reflected power also increased. Also, as the thickness and relative permittivity of the double dielectric layers increased, the overall reflected power increased. The numerical results obtained by using the numerical methods of FGMM and PMM to the structure proposed in this paper agree very well.

Alternaria in Food: Ecophysiology, Mycotoxin Production and Toxicology

  • Lee, Hyang Burm;Patriarca, Andrea;Magan, Naresh
    • Mycobiology
    • /
    • v.43 no.2
    • /
    • pp.93-106
    • /
    • 2015
  • Alternaria species are common saprophytes or pathogens of a wide range of plants pre- and post-harvest. This review considers the relative importance of Alternaria species, their ecology, competitiveness, production of mycotoxins and the prevalence of the predominant mycotoxins in different food products. The available toxicity data on these toxins and the potential future impacts of Alternaria species and their toxicity in food products pre- and post-harvest are discussed. The growth of Alternaria species is influenced by interacting abiotic factors, especially water activity ($a_w$), temperature and pH. The boundary conditions which allow growth and toxin production have been identified in relation to different matrices including cereal grain, sorghum, cottonseed, tomato, and soya beans. The competitiveness of Alternaria species is related to their water stress tolerance, hydrolytic enzyme production and ability to produce mycotoxins. The relationship between A. tenuissima and other phyllosphere fungi has been examined and the relative competitiveness determined using both an Index of Dominance ($I_D$) and the Niche Overlap Index (NOI) based on carbon-utilisation patterns. The toxicology of some of the Alternaria mycotoxins have been studied; however, some data are still lacking. The isolation of Alternaria toxins in different food products including processed products is reviewed. The future implications of Alternaria colonization/infection and the role of their mycotoxins in food production chains pre- and post-harvest are discussed.

A Study of Thermal and Chemical Quenching of Premixed Flame by Flame-Surface Interaction (화염-표면 상호작용에 의한 예혼합 화염의 열소염 및 화학소염에 관한 연구)

  • Kim, Kyu-Tae;Lee, Dae-Hoon;Kwon, Se-Jin
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.2
    • /
    • pp.1-8
    • /
    • 2005
  • Incomplete combustion due to quenching in a narrow confinement has been a major problem for realization of a reliable micro combustion device. In most micro combustors, effects of flows are absent in the quenching because the flow is laminar and no severe stretch is present. In such circumstance, quenching is caused either by heat loss or by removal of active radicals to the wall surface of the confinement. An experimental investigation was carried out to investigate the relative significance of these two causes of quenching of a premixed flame. A premixed jet burner with a rectangular cross section at the exit was built. At the burner exit, the flame stands between two walls with adjustable distance. The gap between the two walls at which quenching occurs was measured at different wall surface conditions. The results were analyzed to estimate the relative significance of heat loss to the wall and the removal of radicals at the surface. The measurements indicated that the quenching distance was independent of the wall surface characteristics such as oxygen vacancy, grain boundary, or impurities at low temperature. At high temperature, however, the surface characteristics strongly affect the quenching distance, implying that radical removal at the wall plays a significant role in the quenching process.

  • PDF