• 제목/요약/키워드: reinforcing

검색결과 3,014건 처리시간 0.027초

지속 하중하에서 철근콘크리트 부재의 염화물 침투특성에 따른 철근부식에 관한 연구 (A Study on the Reinforcing Bar Corrosion Caused by Permeation of Chloride Ion Under Sustained Load)

  • 최일호;김형래;윤상천;지남용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.779-782
    • /
    • 1999
  • This study was carried out to estimate the effects of the loading conditions on the corrosion of reinforcing bars and permeation of chloride ion. The permeation of chlorides depends not only on the transfer properties in concrete but also on the load applied in the case of reinforced concrete structures. Recent studies reported that the loading conditions affected the corrosion rate of the reinforcing bars under existence of an external current supply. But it was not reported that loading conditions affected corrosion of reinforcing bar caused by the characteristics of permeation and the process of cracking. In this experiment, it was shown that the corrosion of reinforcing bars and the characteristics of permeating were greatly affected by the loading conditions.

  • PDF

폴리머 시멘트 슬러리에 의한 철근의 방청성능 (The Anti-Corrosion Properties of Coated Reinforcing Bar Using Polymer Cement Slurry)

  • 김영집;김연홍;윤보원;조영국;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.201-206
    • /
    • 2002
  • The purpose of this study is to improve the anti-corrosive properties of coated reinforcing bar using polymer cement slurry. Poymer cement slurry are prepared with three types of polymer dispersions and corrosion inhibiting admixture. And tested for corrosion accelerating tests such as immersion in NaCl 10% solution NaCl 10% solution spray, high temperature and pressure steam in condition of 8cycles, carbonation before and after, penetration of NaCl solution. From the test results, it is concluded that the anti-corrosive properties are considerably improved by coating using polymer cement slurry at surface of reinforcing bar. And this trend is marked by adding of corrosion inhibiting admixture. The difference of the anti-corrosive properties is hardly recognized according to types of polymer dispersions. The anti-corrosive properties of coated reinforcing bar using polymer foment slurry are improved to a great extent compared to those of plain reinforcing bar accordiy to increasing content of chloride ion in cement concrete.

  • PDF

이질구조부 보강판의 길이에 따른 혼합구조보의 특성에 관한 연구 (A Study on Properties of Composite Beams according to Length of Reinforcing Plate for Different Types of Structure)

  • 이승조;박정민;김화중
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.297-302
    • /
    • 2002
  • This paper investigated the properties of flexural behavior of composite beams (end-Reinforced concrete, center-Steel concrete) according to attaching length of main bars to flange, shear reinforcing length for different types of structure. In the preceding study, structural properties of composite beams were investigated according to shear span to depth ratio, attaching method of main bars and shear reinforcing method. Based on these results, a series of experiments was carried out according to attaching length of main bar & reinforcing length for different types of structure. Consequently, as attaching length of main bar and shear reinforcing length increased, composite beams represented higher strength, ductility index and stress mechanism distributed in connection zone of different types of structure.

  • PDF

A comparative study on bond of different grade reinforcing steels in concrete under accelerated corrosion

  • Kurklu, G.;Baspinar, M.S.;Ergun, A.
    • Steel and Composite Structures
    • /
    • 제14권3호
    • /
    • pp.229-242
    • /
    • 2013
  • Corrosion is important reason for the deterioration of the bond between reinforcing steel and the surrounding concrete. Corrosion of the steel mainly depends on its microstructure. Smooth S220, ribbed S420 and S500 grade reinforcing steels were used in the experiments. Samples were subjected to accelerated corrosion. Pullout tests were carried out to evaluate the effects of corrosion on bond strength of the specimens. S500 grade steel which has tempered martensite microstructure showed lower corrosion rate in concrete than S220 and S420 steels which have ferrite+perlite microstructure. S500 grade steel showed highest bond strength among the other steel grades in concrete. Bond strength between reinforcing steel and concrete increased with increase in the strength of steel and concrete. It also depends on whether reinforcing bar is ribbed or not.

콘크리트와 철근의 부착강도에 대한 횡구속 설계변수 (Design Parameters of Confinement on Bond Strength of Reinforcing Steel to Concrete)

  • 김상준;이재열;이웅세;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.653-658
    • /
    • 1999
  • Bond between reinforcing bars and the surrounding concrete is supposed to safely transfer load in the design process of reinforced concrete structures. Bond failure of reinforcing bars generally take place by splitting of concrete cover as bond force between concrete and reinforcing bars exceeds the resistance by the confinement of the concrete cover and transverse reinforcement. Confinement, concrete cover and transverse reinforcement, on bond are the key factor of current provision to determine development length of reinforcing bars to concrete. In this study, previous available data are analyzed with respect to the current provisions for development and splice of reinforcement. From this study, the new provision for the design are proposed, which will be efficient and effective with some specific limit value.

  • PDF

콘크리트내 철근위치검출을 위한 레이더화상처리기술 (Rader Image Processing for Locating of Reinforcing bars in Concrete)

  • 박석균
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.807-812
    • /
    • 1999
  • Locating of reinforcing bars, in particular to know their accurate depths, is very important thing in radar inspection of concrete structures. By the way, a depth estimation of reinforcing bars in concrete structures by the radar is not easy because micorwave propagation velocity in test area is generally unknown. This problem can be solved by Generalized Hough transformation technique. Using this technique, the micorwave propagation velocity in test area can be detected from the radar image, which appear as hyperbolas conveying the velocity information in their shape. A developed speed-up technique for the computation of the Generalized Hough transformation is also investigated in this study. As a result, although it becomes difficult to locate reinforcing bars when multiple parallel bars lying too close together, there is a possibility of detecting accurate depths of reinforcing bars in test area by the proposed method.

  • PDF

전자파 레이더법에 의한 콘크리트 내 철근위치 및 공동형상 해석에 관한 연구 (Analysis for Location of Reinforcing Bars and Detection of Shape of Voids in Concrete Structures using Electromagnetic Radar)

  • 박석균
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.471-476
    • /
    • 2003
  • The presence of voids under pavements or behind tunnel linings results in their deterioration. To detect these voids effectively by non-destructive tests, a method using radar was proposed. In this research, not only the detection of shape of voids, but also the location of reinforcing bars by radar image analysis is investigated. The experiments and image processing were conducted to detect voids and to locate reinforcing bars in or under concrete pavements (or tunnel linings) with reinforcing bars. From the results, the fundamental algorithm for tracing the reinforcing bars and voids, improving the horizontal resolution of the object image and detecting shape of objects, was verified.

  • PDF

An Experimental Study on the Evaluation of Shear Performance of PVA Fiber Reinforced RC Deep Beam with High Strength Headed Rebar

  • Kim, Seunghun;Lee, Kyuseon;Lee, Yongtaeg
    • Architectural research
    • /
    • 제19권4호
    • /
    • pp.109-115
    • /
    • 2017
  • This study is done to evaluate how existence of shear-span ratio and shear reinforcing bar effects on shear performance from through shear experiment using PVA fiber reinforced ferroconcrete building. Ratio of shear-span was set 1, 1.7, and arrangement of shear reinforcing bar was set with KCI2012 regulation. In result, subject with less shear-span ratio, and shear reinforcing bar with arrangement of bar shows high stiffness. Subjects with high shear-span ratio show large difference depending on existence of shear reinforcing bar. Therefore, theoretical shear strength followed by CEB code underestimates experimental shear strength by 43.9%. Shear strength of the deep beam with headed bars is more affected by the bearing strength of head than the bond strength of bar.

콘크리트 내부 균열에 대한 보수기법의 기초적 연구 (A Fundamental Study on the Method Repair for Crack in Concrete by Corrosion of Steel Reinforcing)

  • 임남기;백민수;권영진;최응규;정란;정상진;최문식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.579-584
    • /
    • 1997
  • This experimentation is to apperciation an efficiency of repair for processing crack by corrosion of steel reinforcing, Crack on concrete by corrosion of steel reinforcing is the fact that the first crack appear on the surface of water because of supplying is of oxygen and water. The crack processing is on surface to be contacted by air and to bottom as mainly the vertical direction from a surface of water. The experimentation gives rise to crack in model by electricity. Crack by corrosion of steel reinforcing is more internal crack than external crack. since it is so. crack by corrosion of steel reinforcing have to attention to repair or intermal crack.

  • PDF

3D 스캐너를 활용한 철근 자동검측방식의 현장적용성 연구 (A Study on Application of Automated Inspection System for Rebar Inspection using 3D Scanner)

  • 임현수;김태훈;이명도;김창원;차민수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.157-158
    • /
    • 2019
  • Reinforcing bars are an important material for tensile strength of structures. For this reason, the inspection of the reinforcing bars confirming the layout and omission is very important for the safety of the structures. However, the current method of inspecting of the reinforcing bars through photographs of specific areas is difficult to identify condition all reinforcing bars. And It is also difficult to confirm after completion of a building. Therefore, reinforcing bar inspection using 3D scanner is required for automation of rebar inspection and database construction. For this purpose, this study test application of automated inspection method for rebar inspection using 3D scanner and discuss the effect of this method.

  • PDF