A reliable approach for determining concrete strength in structures by using cores

  • Durmus, Aysegul;Ozturk, Hasan Tahsin;Durmus, Ahmet
    • Computers and Concrete
    • /
    • v.11 no.5
    • /
    • pp.463-473
    • /
    • 2013
  • As known, concrete classes are described as strength of standard specimens produced and kept in ideal conditions, not including reinforcement and not subjected to any load effect before. Under the circumstances, transforming core strengths to the standard specimen strength is necessary and considering all parameters, affected on the core strength, is inevitable. In fact, effects of the reinforcement and the load history on concrete strength are generally neglected when these mentioned transforms are performing. The main purpose of this paper is investigating the effects of the reinforcement and the load history on the core strength. This investigation is experimentally performed on cores drilled from specimens having different keeping conditions, reinforced, unreinforced, subjected to bending and central pressure in various proportions of failure load during specified periods. Obtained results show that the importance of these effects cannot be neglected.

Estimation of Vibration Plate due to Moving Oscillator in Reinforcement Concrete (이동 가진원에 따른 철근 콘크리트 판에서의 진동평가)

  • Kim, Ie-Sung;Yoon, Seoung-Hyun;Park, Kang-Geun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.6
    • /
    • pp.83-90
    • /
    • 2007
  • Today, many studies are progressed about source of vibration oscillator in reinforcement concrete structures. Source of vibration oscillator is load when it is happen from walking inhabitant. It is transmitted to another inhabitant through reinforcement concrete plate, and it is type of elastic wave. Those descriptions are ram wave and primary wave, secondary wave, and the are through the surface and inside plate. Analysis studies of those waves are used to piezoelectric materials. But, they are difficult to 3 axial type of transmitting elastic wave in concrete element. In this study, a fundamental study for source estimations of vibration oscillator using micro accelerometer are discussed.

  • PDF

Study on seismic strengthening of railway bridge pier with CFRP and concrete jackets

  • Ding, Mingbo;Chen, Xingchong;Zhang, Xiyin;Liu, Zhengnan;Lu, Jinghua
    • Earthquakes and Structures
    • /
    • v.15 no.3
    • /
    • pp.275-283
    • /
    • 2018
  • Seismic strengthening is essential for existing bridge piers which are deficient to resist the earthquake. The concrete and CFRP jackets with a bottom-anchoring method are used to strengthen railway bridge piers with low reinforcement ratio. Quasi-static tests of scaled down model piers are performed to evaluate the seismic performance of the original and strengthened bridge pier. The fracture characteristics indicate that the vulnerable position of the railway bridge pier with low reinforcement ratio during earthquake is the pier-footing region and shows flexural failure mode. The force-displacement relationships show that the two strengthening techniques using CFRP and concrete jackets can both provide a significant improvement in load-carrying capacity for railway bridge piers with low reinforcement ratio. It is clear that the bottom-anchoring method by using planted steel bars can guarantee the CFRP and concrete jackets to work jointly with original concrete piers Furthermore, it can be found that the use of CFRP jacket offers advantages over concrete jacket in improving the energy dissipation capacity under lateral cyclic loading. Therefore, the seismic strengthening techniques by the use of CFRP and concrete jackets provide alternative choices for the large numbers of existing railway bridge piers with low reinforcement ratio in China.

Bond and ductility: a theoretical study on the impact of construction details - part 1: basic considerations

  • Zwicky, Daia
    • Advances in concrete construction
    • /
    • v.1 no.1
    • /
    • pp.103-119
    • /
    • 2013
  • The applicability of limit analysis methods in design and assessment of concrete structures generally requires a certain plastic deformation capacity. The latter is primarily provided by the ductility of the reinforcement, being additionally affected by the bond properties between reinforcing steel and concrete since they provoke strain localization in the reinforcement at cracks. The bond strength of reinforcing bars is not only governed by concrete quality, but also by construction details such as bar ribbing, bar spacing or concrete cover thickness. For new concrete structures, a potentially unfavorable impact on bond strength can easily be anticipated through appropriate code rules on construction details. In existing structures, these requirements may not be necessarily satisfied, consequently requiring additional considerations. This two-part paper investigates in a theoretical study the impacts of the most frequently encountered construction details which may not satisfy design code requirements on bond strength, steel strain localization and plastic deformation capacity of cracked structural concrete. The first part introduces basic considerations on bond, strain localization and plastic deformation capacity as well as the fundamentals of the Tension Chord Model underlying the further investigations. It also analyzes the impacts of the hardening behavior of reinforcing steel and concrete quality. The second part discusses the impacts of construction details (bar ribbing, bar spacing, and concrete cover thickness) and of additional structure-specific features such as bar diameter and crack spacing.

Reinforcement detailing of a corbel via an integrated strut-and-tie modeling approach

  • Ozkal, Fatih Mehmet;Uysal, Habib
    • Computers and Concrete
    • /
    • v.19 no.5
    • /
    • pp.589-597
    • /
    • 2017
  • Strut-and-tie modeling method, which evolved on truss-model approach, has generally been preferred for the design of complex reinforced concrete structures and structural elements that have critical shear behavior. Some structural members having disturbed regions require exceptional detailing for all support and loading conditions, such as the beam-column connections, deep beams, short columns or corbels. Considering the general expectation of exhibiting brittle behavior, corbels are somewhat dissimilar to other shear critical structures. In this study, reinforcement layout of a corbel model was determined by the participation of structural optimization and strut-and-tie modeling methods, and an experimental comparison was performed against a conventionally designed model.

On the Implementation of Fuzzy Arithmetic for Prediction Model Equation of Corrosion Initiation

  • Do Jeong-Yun;Song Hun;Soh Yang-Seob
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.1045-1051
    • /
    • 2005
  • For critical structures and application, where a given reliability must be met, it is necessary to account for uncertainties and variability in material properties, structural parameters affecting the corrosion process, in addition to the statistical and decision uncertainties. This paper presents an approach to the fuzzy arithmetic based modeling of the chloride-induced corrosion of reinforcement in concrete structures that takes into account the uncertainties in the physical models of chloride penetration into concrete and corrosion of steel reinforcement, as well as the uncertainties in the governing parameters, including concrete diffusivity, concrete cover depth, surface chloride concentration and critical chloride level for corrosion initiation. The parameters of the models are regarded as fuzzy numbers with proper membership function adapted to statistical data of the governing parameters and the fuzziness of the corrosion time is determined by the fuzzy arithmetic of interval arithmetic and extension principle

Corrosion Characteristics of Reinforcement Concrete made by Marine Aggregate (해양골재로 제작한 철근 콘크리트의 부식특성)

  • 남진각;정진아;문경만;이명훈;김기준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.217-222
    • /
    • 1998
  • In these days, mostof marine structures are constructed by reinforcement concrete due to economic reason. Theoretically, it is widely recognized that rebar in sound concrete is safe against corrosion because of the high alkalinity of concrete. However, corrosion for reinforcement concrete made by marine aggregate and exposed to ocean enviroments has become serious social problem. Especially in Korea, with the rapid economic growth construction activities have been accelerated and needed more natural aggregate. Therefore, inevitably marine aggregate had to be used due to limitation of good quality aggregate. In this study, as a part of efforts to establish the fundamental counterplan on corrosion problems related to marine aggregate, concrete specimens with chloride containing material and inhibitor have been studied. And, in order to analyze corrosion characteristics several electrochemical techniques including half-cell potential survery, linear and cyclic polarization tests were carried out.

  • PDF

Effect of geometrical configuration on seismic behavior of GFRP-RC beam-column joints

  • Ghomia, Shervin K.;El-Salakawy, Ehab
    • Advances in concrete construction
    • /
    • v.9 no.3
    • /
    • pp.313-326
    • /
    • 2020
  • Glass fiber-reinforced polymer (GFRP) bars have been introduced as an effective alternative for the conventional steel reinforcement in concrete structures to mitigate the costly consequences of steel corrosion. However, despite the superior performance of these composite materials in terms of corrosion, the effect of replacing steel reinforcement with GFRP on the seismic performance of concrete structures is not fully covered yet. To address some of the key parameters in the seismic behavior of GFRP-reinforced concrete (RC) structures, two full-scale beam-column joints reinforced with GFRP bars and stirrups were constructed and tested under two phases of loading, each simulating a severe ground motion. The objective was to investigate the effect of damage due to earthquakes on the service and ultimate behavior of GFRP-RC moment-resisting frames. The main parameters under investigation were geometrical configuration (interior or exterior beam-column joint) and joint shear stress. The performance of the specimens was measured in terms of lateral load-drift response, energy dissipation, mode of failure and stress distribution. Moreover, the effect of concrete damage due to earthquake loading on the performance of beam-column joints under service loading was investigated and a modified damage index was proposed to quantify the magnitude of damage in GFRP-RC beam-column joints under dynamic loading. Test results indicated that the geometrical configuration significantly affects the level of concrete damage and energy dissipation. Moreover, the level of residual damage in GFRP-RC beam-column joints after undergoing lateral displacements was related to reinforcement ratio of the main beams.

Reinforcement of RC Structures with External Post-Tensioning Method (외부 포스트텐셔닝공법에 의한 콘크리트 구조물의 보강사례 연구)

  • 정원용;김승익
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.387-392
    • /
    • 2002
  • In many years, post-tensioning method has been used for structural reinforcement of RC structures due to easy installation and good quality control. This study presents practical application results for the effectiveness of structural post-tensioning reinforcement of the FCM bridge girders, cement silos and building girders. For the FCM bridges deflected excessively at the end of girders, for cement silos cracked vertically at silo surface and for building girders deflected due to heavy load from roof, the external post-tensioning method was used for uplifting deflected girders and closing cracks with increasing resisting capacity of the structures. It was demonstrated that all the items were rehabilitated nearly to the initial construction status according to the field test results.

  • PDF

Compressive resistance behavior of UHPFRC encased steel composite stub column

  • Huang, Zhenyu;Huang, Xinxiong;Li, Weiwen;Zhang, Jiasheng
    • Steel and Composite Structures
    • /
    • v.37 no.2
    • /
    • pp.211-227
    • /
    • 2020
  • To explore the feasibility of eliminating the longitudinal rebars and stirrups by using ultra-high-performance fiber reinforcement concrete (UHPFRC) in concrete encased steel composite stub column, compressive behavior of UHPFRC encased steel stub column has been experimentally investigated. Effect of concrete types (normal strength concrete, high strength concrete and UHPFRC), fiber fractions, and transverse reinforcement ratio on failure mode, ductility behavior and axial compressive resistance of composite columns have been quantified through axial compression tests. The experimental results show that concrete encased composite columns with NSC and HSC exhibit concrete crushing and spalling failure, respectively, while composite columns using UHPFRC exhibit concrete spitting and no concrete spalling is observed after failure. The incorporation of steel fiber as micro reinforcement significantly improves the concrete toughness, restrains the crack propagation and thus avoids the concrete spalling. No evidence of local buckling of rebars or yielding of stirrups has been detected in composite columns using UHPFRC. Steel fibers improve the bond strength between the concrete and, rebars and core shaped steel which contribute to the improvement of confining pressure on concrete. Three prediction models in Eurocode 4, AISC 360 and JGJ 138 and a proposed toughness index (T.I.) are employed to evaluate the compressive resistance and post peak ductility of the composite columns. It is found that all these three models predict close the compressive resistance of UHPFRC encased composite columns with/without the transverse reinforcement. UHPFRC encased composite columns can achieve a comparable level of ductility with the reinforced concrete (RC) columns using normal strength concrete. In terms of compressive resistance behavior, the feasibility of UHPFRC encased steel composite stub columns with lesser longitudinal reinforcement and stirrups has been verified in this study.