• 제목/요약/키워드: reinforced concrete pile

검색결과 98건 처리시간 0.024초

콘크리트 합성 유리섬유 강화 복합소재 파일의 실험적 거동분석 (Experimental Study of Concrete Filled GFRP Composite Pile)

  • 이성우;최석환;김병석;조남훈;홍종삼
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.111-118
    • /
    • 2003
  • Structural characteristics of concrete filled glass fiber reinforced composite pile was studied. Confinement model of composite pile was derived from experimental data, and numerical method to find P-M diagram of composite pile was developed. The flexure-compression test results were compared with analytical P-M diagram and it is demonstrated that they agree well each other. Utilizing these results, pilot composite pile was designed fabricated, and flexural test were conducted,

  • PDF

원심성형 철근콘크리트 말뚝 이음부의 보강 효과 (Effect of Joint Reinforcement on Reinforced Concrete Pile by Centrifugal Casting)

  • 주상훈;황훈희
    • 한국산학기술학회논문지
    • /
    • 제20권11호
    • /
    • pp.501-509
    • /
    • 2019
  • 최근 건축과 토목 구조물 기초에 적용되는 말뚝의 시공법은 환경 훼손, 소음 공해, 그리고 주위 민원을 최소화하기 위해 항타공법에서 매입공법 위주로 변화하는 추세를 보이고 있다. 이러한 시공방법의 변화로 인해 기존의 항타공법으로 사용되었던 말뚝 대신, 재료 및 구조적인 시스템 측면에서 보다 최적화되고 경제적인 매입용 말뚝의 개발이 요구되고 있다. 본 연구에서는 매입용 말뚝인 원심성형 철근콘크리트 말뚝의 보강된 이음방법을 제안하였다. 이전의 연구에서는 원심성형 철근콘크리트 말뚝에 대해 연장된 원형띠판과 스터드로 구성된 이음 보강방법이 기존 이음방법의 구조성능을 개선 시킬 수 있을 것으로 검토되었다. 따라서, 본 연구에서는 이러한 이음방법의 구조성능을 말뚝의 휨과 전단 강도 실험을 통해 검증하였다. 이 제안된 이음방법은 설계에서 요구되는 휨과 전단 강도에 대해 충분한 성능을 보인 것으로 실험에서 나타났다. 또한, 전반적인 하중-처짐 거동이 이음부가 없는 일체형 구조에 근접하므로 설계에서 예상하는 거동과 성능이 안정적으로 현장 구조물에 반영될 수 있을 것으로 기대된다.

말뚝머리 중공 프리캐스트 철근콘크리트 말뚝의 성능 평가 (Development and Evaluation of Hollow-head Precast Reinforced Concrete Pile)

  • 방진욱;현정환;안경철;김윤용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권2호
    • /
    • pp.130-137
    • /
    • 2017
  • 최근 경제 성장과 건설 기술의 발달로 인해 구조물이 대형화, 고층화됨에 따라 상부구조물을 지지할 수 있는 기초의 역할이 중요시 되고 있다. 이 연구에서는 철근콘크리트 말뚝 성능향상을 목적으로 프리캐스트공법과 철근 및 속채움 콘크리트로 말뚝머리부를 보강한 철근 콘크리트 말뚝(HPC)을 개발하고 한계상태설계법을 바탕으로 말뚝성능을 예측하였고 설계와 실제강도와 비교를 통해 말뚝 내력의 안전성을 평가하였다. HPC말뚝 본체의 단면형상은 최대폭 500 mm, 최소폭 475 mm의 10각 단면으로 말뚝머리부 본체 두께는 70 mm이다. 중공부 본체 내측은 도로교설계기준에서 제시하는 수평전단강도를 확보하기 위해 요철형상으로 제작하였다. 전단강도 실험 결과 사인장균열이 발생하였지만 최종 파괴단계까지 급격한 파괴 없이 안정적인 전단내력을 확보하였고 한계상태설계법으로 예측한 전단강도를 135%, 119% 상회하였다. 말뚝머리 본체부 두께에 가외철근 보강 유무에 따라 제작된 실험체의 항타실험 결과 모든 말뚝 실험체에 균열이 발생하지 않아 충격에 대한 저항이 우수한 것으로 나타났다. 기성 PHC말뚝과 HPC말뚝 연결부 휨실험을 통해 측정된 휨하중을 평가한 결과 기성 PHC말뚝 설계 휨균열 하중에 비해 1.51배 및 1.48배 높은 값을 나타내어 충분한 연결부 휨내력을 확보하는 것으로 나타났다.

Model verification and assessment of shear-flexure interaction in pile foundations

  • Lemnitzer, Anne;Nunez, Eduardo;Massone, Leonardo M.
    • Earthquakes and Structures
    • /
    • 제11권1호
    • /
    • pp.141-163
    • /
    • 2016
  • Fiber models have been developed and applied to various structural elements such as shear walls, beams and columns. Only scarcely have fiber models been applied to circular foundation systems such as cast in drilled holes shafts (CIDH). In pile foundations with constraint head boundary conditions, shear deformations can easily contribute to the lateral pile response. However, soil structure interaction formulations such as the p-y method, commonly used for lateral pile design, do not include structural shear deformations in its traditional derivation method. A fiber model that couples shear and axial-bending behavior, originally developed for wall elements was modified and validated on circular cross sections (columns) before being applied to a 0.61 m diameter reinforced concrete (RC) pile with fixed head boundary conditions. The analytical response was compared to measured test results of a fixed head test pile to investigate the possible impact of pile shear deformations on the displacement, shear, and moment profiles of the pile. Results showed that shear displacements and forces are not negligible and suggest that nonlinear shear deformations for RC piles should be considered for fixed-head or similar conditions. Appropriate sensor layout is recommended to capture shear deformation when deriving p-y curves from field measurements.

Smart monitoring system using electromagnetic waves to evaluate the integrity of reinforced concrete structural elements

  • Jong-Sub Lee;Dongsoo Lee;Youngdae Kim;Goangseup Zi;Jung-Doung Yu
    • Computers and Concrete
    • /
    • 제31권4호
    • /
    • pp.293-306
    • /
    • 2023
  • This study proposes and demonstrates a smart monitoring system that uses transmission lines embedded in a reinforced concrete structure to detect the presence of defects through changes in the electromagnetic waves generated and measured by a time-domain reflectometer. Laboratory experiments were first conducted to identify the presence of voids in steel-concrete composite columns. The results indicated that voids in the concrete caused a positive signal reflection, and the amplitude of this signal decreased as the water content of the soil in the void increased. Multiple voids resulted in a decrease in the amplitude of the signal reflected at each void, effectively identifying their presence despite amplitude reduction. Furthermore, the electromagnetic wave velocity increased when voids were present, decreased as the water content of the soil in the voids increased, and increased with the water-cement ratio and curing time. Field experiments were then conducted using bored piles with on-center (sound) and off-center (defective) steel-reinforcement cage alignments. The results indicated that the signal amplitude in the defective pile section, where the off-center cage was poorly covered with concrete, was greater than that in the pile sections where the cage was completely covered with concrete. The crosshole sonic logging results for the same defective bored pile failed to identify an off-center cage alignment defect. Therefore, this study demonstrates that electromagnetic waves can be a useful tool for monitoring the health and integrity of reinforced concrete structures.

등입도 투수성 콘크리트 보강 조립토 다짐말뚝의 거동특성 및 침하량 평가기법 (A Estimation Method of Settlement and The Behaviour Characteristics of Granular Compaction Pile Reinforced with Uniformly Graded Permissible Concrete)

  • 김정호;황정순;김승욱;김종민;김홍택
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.362-371
    • /
    • 2006
  • The behaviour characteristics of Granular Compaction Pile(GCP) are mainly governed by the lateral confining pressure mobilized in the matrix soft soil to restrain the bulging failure of the granular compaction pile. The GCP method is most effective in soft soil with untrained shear strength ranging from $15\sim50\;kPa$. However, the efficiency of this method is falling down in the more compressible soil conditions, which does not provide sufficient lateral confinement. In the present study, the GCP method reinforced with uniformly graded permissible concrete is suggested for the extension of application to the soft ground. Also, large triaxial compression tests are conducted on composite- reinforced soil samples for verification of availability of the suggested method and the settlement estimation method of the reinforced GCP is proposed. Further, for the verification of a validity of the proposed method, predicted settlements are compared with results of numerical analyses. Tn addition, parametric studies are performed together with detailed analyses of relevant design parameters.

  • PDF

Corrosion of Reinforcement and Its Effect on Structural Performance in Marine Concrete Structures

  • Yokota, Hiroshi;Kato, Ema;Iwanami, Mitsuyasu
    • Corrosion Science and Technology
    • /
    • 제6권6호
    • /
    • pp.297-303
    • /
    • 2007
  • This paper discusses the chloride-induced corrosion of reinforcement in marine concrete structures focusing on the variability in the progress of deterioration. Through tests and analyses of reinforced concrete slabs taken out from existing open-pile structures that have been in service for 30 to 40 years, the following topics were particularly discussed: variation in chloride ion profiles of concrete, variation in corrosion properties of reinforcement embedded in concrete, and influence of the reinforcement corrosion on the load-carrying capacity of the concrete slabs. As a result, their variability was found to be very large even in one reinforced concrete slab with almost the same conditions. It was also discussed how to determine the calculation parameters for prediction of decreasing in load-carrying capacity of concrete members with chloride-induced corrosion of reinforcement.

대형 UTM을 이용한 강관합성 말뚝재료의 강도 특성 평가 (Evaluation on compressive strength of steel-concrete composite piles using a large scaled UTM(Universal Test Machine))

  • 이주형;권형민;박재현;곽기석;정문경
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.482-489
    • /
    • 2009
  • Various model piles with different sections such as reinforced concrete, steel, steel-concrete composite without rebar and steel-concrete composite with rebar were made, and vertical load test was conducted using a large scaled UTM(Universal Test Machine) to evaluate Young's modulus and ultimate load of the model piles. Based on the tests, ultimate load of steel-concrete composite pile is 31% greater than the sum of it of reinforced concrete pile and it of steel pile. This is caused that ultimate load and Young's modulus of inner concrete increase due to confining effect by outer steel casing. Variation of ultimate load is also insignificant depending on the ratio of length to diameter(L/D), therefore bucking has not an effect on change of ultimate load in case of the L/D below 10.

  • PDF

FRP 콘크리트 합성말뚝의 압축강도에 대한 실험적 연구 (An Experimental Study for the Compression Strength of Hybrid CFFT Pile)

  • 최진우;박준석;남정훈;안동준;강인규;윤순종
    • 복합신소재구조학회 논문집
    • /
    • 제2권1호
    • /
    • pp.30-39
    • /
    • 2011
  • 이 논문에서는, CFT 감재-콘크리트 합성말뚝과 FRP를 원주방향으로 보강한 FRP-콘크리트 합성말뚝 (CFFT)과 관련하여 발생하는 문제점들을 완하시키기 위해 새롭게 제안된 콘크리트 채움 원형 FRP 말뚝 (HCFFT)의 구조적 거동에 대한 실험적 연구결과를 발표하였다. 연구를 통해 기존의 CFT와 CFFT 말뚝과 비교하여 새로 제안한 HCFFT 말뚝이 말뚝 기초의 시공에서 축하중과 휨모멘트를 포함하는 상부하중을 지반에 효과적으로 전달할 수 있음을 알 수 있었다.

Cyclic behavior of connection between footing and concrete-infilled composite PHC pile

  • Bang, Jin-Wook;Hyun, Jung Hwan;Lee, Bang Yeon;Kim, Yun Yong
    • Structural Engineering and Mechanics
    • /
    • 제50권6호
    • /
    • pp.741-754
    • /
    • 2014
  • The conventional PHC pile-footing connection is the weak part because the surface area and stiffness are sharply changed. The Composite PHC pile reinforced with the transverse shear reinforcing bars and infilled-concrete, hereafter ICP pile, has been developed for improving the flexural and shear performance. This paper investigates the cyclic behavior and performance of the ICP pile-footing connection. To investigate the behavior of the connection, one PHC and two ICP specimens were manufactured and then a series of cyclic loading tests were performed. From the test results, it was found that the ICP pile-footing connection exhibited higher cyclic behavior and connection performance compared to the conventional PHC pile-footing connection in terms of ductility ratio, stiffness degradation and energy dissipation capacity.