• 제목/요약/키워드: regenerative converter

검색결과 72건 처리시간 0.027초

도시 철도용 사이리스터 듀얼 컨버터 시스템의 3병렬 운전 제어 기법에 관한 연구 (A Study on Three Parallel Operation Control Algorithm of Thyristor Dual Converter System for Urban Railway Substation)

  • 김성안;한성우;조윤현
    • 전기학회논문지
    • /
    • 제66권2호
    • /
    • pp.459-467
    • /
    • 2017
  • An urban railway power substation consists of three thyristor dual converters. Two converters are connected to up and down trolley line to supply the electric energy or feed the regenerative energy back to the distribution. When the two converters break down, the remaining converter is used in an emergency. One thyristor dual converter system (TDCS) manages the energy of two or three railway stations. If the TDCS fails, the trains stop operating. To solve the problem, this paper proposes the three parallel operation control algorithm of thyristor dual converter system using the emergency converter. The broken TDCS can be replaced by the emergency converter in other TDCS. The effectiveness of this proposed control is verified by simulation.

HDD 읽기 채널용 6-bit 800 Msample/s DSDA 아날로그/디지털 변환기의 설계 (Design of 6-bit 800 Msample/s DSDA A/D Converter for HDD Read Channel)

  • 정대영;정강민
    • 정보처리학회논문지A
    • /
    • 제9A권1호
    • /
    • pp.93-98
    • /
    • 2002
  • 본 논문에서는 하드디스크 드라이브 읽기 채널용 아날로그/디지털 변환기를 설계하였다. 본 회로는 고속 저에러율 비교 동작이 가능한 빠른 regenerative autozero 비교기에 기반을 두고 있고, 아키텍쳐에 Double Speed Dual ADC(DADA) 방식을 사용하여 전체 A/D 변환기의 속도를 효과적으로 향상시켰다. 또한 autozero 구조에 적합한 새로운 타입의 thermometer-to-binary 디코더를 사용하여 글리치를 제거하였고 기존의 구조를 보다 최적화시켰다. 이 ADC는 6-bit, 해상도, msample/s 최대 변환속도로 설계되었으며, 390mW 전력 소모와 한 클럭주기의 latency를 가진다. 설계에 0.65m CMOS 공정을 사용하였다.

고조파 저감 능력을 가진 회생용 인버터 시스템 연구 (A study of regenerative inverter system with capability of harmonic reduction)

  • 최창열;배창환;장수진;송상훈;원충연
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.443-448
    • /
    • 2005
  • This paper proposed a regeneration inverter system, which can regenerate the excessive power form dc bus line to ac source for traction system. The proposed regeneration inverter system for dc traction can reduce harmonics which are include to ac current source. The regenerative inverter is operated as two modes. As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In the paper, a regeneration inverter used PWM DC/AC converter algorithm. And an active power filter used p-q theory. The simulation was composed as a prototype model[3kW]. Simulation results show that two algorithm can be used to real model[100kW]. Finally, the inverter was successfully operated as regeneration mode.

  • PDF

DC전철구간의 회생인버터시스템 개발 (Development of Regeneration Invertor System for DC Electric Railway System)

  • 김용기;김주락;한문섭;김준구;양영철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.505-511
    • /
    • 2008
  • when electric traction system used DC 1500V runs on decline of rail road track and slows down, dc voltage goes beyond regular voltage. In this case extra power is forcibly wasted by resister because rectifier of substation and electric train including power converter and so on are out of order. This paper described a DC electric railway system, which can generate the excessive DC power form DC bus line to AC source in substation for traction system. The purpose of this study was the development of the regenerative inverter system which suppress extra DC-line voltage and regenerate the energy instead of using a resister. That is Developed regenerative inverter system returns the regenerative energy from the DC line voltage to the utility. In addition, the inverter can be compensate the harmonics caused by the power conversion devices used in the DC traction system.

  • PDF

CC-CV충전제어가 가능한 IPMSM 토크제어기법 (IPMSM Torque Control Method available CC-CV Charge Control)

  • 김준찬;원일권;추경민;홍성우;김우재;김도윤;김영렬;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.407-408
    • /
    • 2017
  • In regenerative mode of an IPMSM control system without a bi-directional DC-DC converter, the 3-phase PWM inverter charges the battery. At this time, the regenerative torque reference for braking must output the proper torque reference to charge the battery. This paper proposed a regeneration control method that controls the voltage and current of the battery through CC-CV control at the regenerative braking torque corresponding to the driver's brake control.

  • PDF

Initial Firing Angle Control of Parallel Multi-Pulse Thyristor Dual Converter for Urban Railway Power Substations

  • Kim, Sung-An;Han, Sung-Wo;Cho, Yun-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.674-682
    • /
    • 2017
  • This paper presents an optimal initial firing angle control based on the energy consumption and regenerative energy of a parallel multi-pulse thyristor dual converter for urban railway power substations. To prevent short circuiting the thyristor dual converter, a hysteresis band for maintaining a zero-current discontinuous section (ZCDS) is essential during mode changes. During conversion from the ZCDS to forward or reverse mode, the DC trolley voltage can be stabilized by selecting the optimal initial firing angle without an overshoot and slow response. However, the optimal initial firing angle is different depending on the line impedance of each converter. Therefore, the control algorithm for tracking the optimal initial firing angle is proposed to eliminate the overshoot and slow response of DC trolley voltage. Simulations and experiments show that the proposed algorithm yields the fastest DC voltage control performance in the transient state by tracking the optimal firing angle.

A Novel Soft-Switching Full-Bridge PWM Converter with an Energy Recovery Circuit

  • Lee, Dong-Young;Cho, Bo-Hyung;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.809-821
    • /
    • 2009
  • This paper proposes a new phase-shift full-bridge DC-DC converter by applying energy recovery circuits to a conventional full-bridge DC-DC converter in plasma display panel applications. The converter can achieve soft-switching in main-switches by an extra auxiliary resonant network even with the wide operating condition of both output load and input voltage. The un-coupled design guidelines to the main bridge-leg component parameters for soft-switching operation contribute to conduction loss reduction in the transformer primary side leading to efficiency improvement. The auxiliary switches in the resonant network also operate in zero-current switching. This paper analyzes the operation modes of the proposed scheme and presents the key design guidelines through steady state analysis. Also, the paper verifies the validity of the circuits by hardware experiments with a 1kW DC/DC converter prototype.

안정된 PWM 제어 DC/DC 전력 강압 컨버터 구현 (Implementation of DC/DC Power Buck Converter Controlled by Stable PWM)

  • 노영환
    • 제어로봇시스템학회논문지
    • /
    • 제18권4호
    • /
    • pp.371-374
    • /
    • 2012
  • DC/DC switching power converters produce DC output voltages from different stable DC input sources regulated by a bi-polar transistor. The converters can be used in regenerative braking of DC motors to return energy back in the supply, resulting in energy savings for the systems containing frequent stops. The voltage mode DC/DC converter is composed of a PWM (Pulse Width Modulation) controller, a MOSFET (Metal Oxide Semiconductor Field Effect Transistor), an inductor, and capacitors, etc. PWM is applied to control and regulate the total output voltage. It is shown that the output of DC/DC converter depends on the variation of threshold voltage at MOSFET and the variation of pulse width. In the PWM operation, the missing pulses, the changes in pulse width, and a change in the period of the output waveform are studied by SPICE (Simulation Program with Integrated Circuit Emphasis) and experiments.

에너지 재생 수동 스너버를 적용한 고효율, 고역률 AC/DC Boost 컨버터에 관한 연구 (A Study on the High-Efficiency, High-Power-Factor AC/DC Boost Converter Using a Passive Energy Recovery Snubber)

  • 유종규;김용;백수현;이규훈;정명섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.168-171
    • /
    • 2005
  • The conception of the passive lossless snubber with the simpler is presented. Thus a necessity condition of the passive lossless soft switching converter with the simplest topology is directed. A novel passive regenerative snubber called soft snubber applied to a hard switching converter is proposed. The passive snubber consists of a snubber inductor, two snubber rectifiers, and a snubber capacitor. The losses are reduced by inserting a snubber inductor in the series path of the rectifier during it's turn off. It is so simple that can make energy reset or capacitor discharged directly without producing any current circulation. To show the superiority of this converter is verified through the experiment with a 640W, 100kHz prototype converter.

  • PDF

에너지 회생형 스너브를 이용한 리플 전압 억제기를 가지는 MIC(Module Integrated Converter) (MIC with Ripple Voltage Compensator Using Regenerative Snubber)

  • 김홍성;장훈기;윤여영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 추계학술대회 논문집
    • /
    • pp.75-76
    • /
    • 2014
  • This study deals with a isolation type MIC(Module Integrated Converter) for AC module with advantages such as DC Wireless, freely selectable installation capacity, minimized shadow effect etc. In this paper, MIC circuit with the function which can remove the ripple voltage of PV module and give the discharging path for charged energy in leakage inductance of isolation transformer. The validity of proposed circuir is verified by the simulation with PSIM.

  • PDF