• Title/Summary/Keyword: refuge facility

Search Result 14, Processing Time 0.03 seconds

A Study on the Improvement of the Refuge safety area in High-rise Buildings Type (초고층 건축물의 용도별 피난안전구역 성능확보 방안에 관한 연구)

  • Lee, Byung-Hyun;Lee, Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.288-292
    • /
    • 2016
  • The purpose of this study was to improve the refuge safety area in the high-rise building type. Each simulation was conducted to evaluate the performance of three types in improving the refuge safety area. Targeting the first 63 floors (no refuge safety area), secondly, to target up to the $30^{th}$ floor (refuge safety area on the $30^{th}$ floor, $47^{th}$ floor) specified in domestic laws, and finally, the $20^{th}$ floor (evacuation safety area on the $20^{th}$ floor, $42^{th}$ floor) were considered as targets. Through this analysis, the following results were obtained : The floor for the refuge safety area through simulations showed that the evacuation time is low. It is necessary to improve the floor for the refuge safety area by using the characteristics of the domestic fire fighting vehicle. The first floor for the refuge safety area from the ground floor differs according to the distance and height of the building floor. However, in the case of a business facility it is 15F, and in the case of apartment housing, it is 20F.

A Study on the Community Facility Design Convertible to Refuge in case of Emergency (비상시 대피시설로 전환가능한 주민시설 디자인에 관한 연구)

  • Kim, Hee-Kyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2503-2510
    • /
    • 2014
  • This study chiefly aims to find out the efficient ways of designing community facility convertible to refuge in case of emergency. In order to reach this goal, this study analyzed (1) definition of terminologies regarding disaster and refuge space, (2)present situation of regarding acts and standards, (3)function and spatial specialties of existing community facilities. Besides, in order to clarify the efficient design methods of 'function-convertible-type' community facility, this study executes archival research on (1)spatial requirements, (2)methods of designing futuristic community facility. When making design directives of community facilities, it is important to consider (1)vertical integration of rescue related function, (2)spatial division and architectural installation concerning privacy, (3)proper layout of locker room, shower room, toilet, etc. (4)appropriate size of unit space. It is desirable to execute the refuge function with minimum psychological anxiety in case of disaster through design guideline for 'function-convertible-type' community facility.

A Study on the multiplex refuge facility according to visiter's behavior characteristics (관람객 행동 특성에 따른 멀티플렉스 피난시설 개선방안 연구)

  • Cho Young-Jun;Kim Taek-Woo;Kim Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.187-190
    • /
    • 2005
  • By the rapid technological advance and social needs, demand of Multi Function Facility is on the increase. The multiplex is an alternative of them. In case of fire, special function of facility nay result in terrible accident. Therefore, literature and regulations survey on the multiplex were enforced, Multiplex facilities in Daejeon City were surveyed, and reformation of regulation and structural system were suggested in this study.

  • PDF

A Study on the evaluation of the auditory guide facility under emergency situation (비상시 청각형 유도시설의 유도성능 평가에 관한 연구)

  • Na, Wook-Jung;Jeon, Gyu-Yeob;Hong, Won-Hwa
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1205-1208
    • /
    • 2006
  • Today, our city structure is being complicated from the development of industry. Invisible losses, life and fortune loss caused by arson is embossed in our society. The preparation of counter plan about increasing factors of fire damage is not easy. With respect to mankind life, however, it is very important. Therefore, the focus of this research examine refuge degree in each smoke density level when a fire break out in the space. I evaluated auditory guide facility thorough real scale test. In this thesis, I will propose the efficient refuge deriving facilities.

  • PDF

A Study on the Healing Environment with Natural Elements in Healthcare Facility - Focused on the Case Study of Seoul National University Hospital - (의료시설 내 치유환경 조성을 위한 자연요소 도입에 관한 연구 - 서울대학교병원 사례분석을 중심으로 -)

  • Jeong, Tae-Jong
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.11
    • /
    • pp.61-68
    • /
    • 2019
  • The analysis of outdoor and indoor spatial composition with natural elements is required for the creation of healing environment in healthcare facility to provide basic data for the planning of hospital architecture. Literature review of healing environment and investigation on characteristics of spatial composition in architectural works and healthcare facilities have been conducted. The spatial composition of outdoor space for refuge and prospect from indoor space of Seoul National University Hospital have been analyzed. The result of this research can be summarized as followed. First of all, the main natural elements for healing environment are consisted with refuge in outdoor space and prospect from indoor space. The second one is that natural elements in Seoul National University Hospital are located in central, posterior, and lateral area of main hospital and connectivity, integration, and ERAM(3) which the characteristics of outdoor spatial composition with space syntax are focused on the museum of medicine and landscape area in the center of hospital. The third one is that the outdoor refuge and prospect from indoor space in Seoul National University Hospital can be replaced with cultural heritage like the site of Kyungmogungji and Changgyeonggung palace in and next to the hospital. In addition to the outdoor and indoor spatial composition, it is necessary to analyze the relationship between elements to develop the healing environment of hospital architecture.

A Study on the Escape Measures and Fire Protection System Improvement in Discount Stores (대형할인점의 피난대책 및 소방시설 개선방안에 관한 연구)

  • 홍성우;이영재
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.20-27
    • /
    • 2002
  • This study in focused on proposing the improvement plans for refuge and fire-fighting facilities in large shopping malls that are radically spreading. The main subjects are as follows. - The refuge measure for large shopping malls - Problems of installing the refuge facilities in stores and the solutions - Problems of installing the incendiary facilities in stores and the solutions - Problems of installing the indoor fire plug in stores and the solutions As result of the study, it has turned out that escape stairs which are set up according to the standard of size in the process of design plan, have to be decided for their amount, position, specification, etc, in consideration of the number of residents. It is also required to tighten a standard of installing a sprinkler instead of lightening the fire-fighting section in stores, considering obstacles due to facilities installed and procurement of the escape path. In addition, it needs to lighten a standard of installing the indoor fire plug, which is voluntarily set up at the store section incase of installing a sprinkler to make a practical fire-fighting facility available.

A Study on emergency equipments for accidents of rail infrastructure and rolling-stock (철도 시설 및 차량 분야 사고 발생에 따른 비상대응 설비 환경 분석 연구)

  • Yang, Doh-Chul;Seo, Young-Min
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1817-1823
    • /
    • 2007
  • In this study, we have studied rail infrastructure related to emergency action to manage the risk when emergency caused by faults of facility or rail vehicle during operation happens. Especially we have compared the effect of emergency action with examining the structure of vehicle, tunnel, bridge and access road, etc which are related to emergency action. Also, we have tried to analyze effects of radio and communication equipment, lifesaving and refuge which could be used for rolling stock, station, control room, tunnel, bridge and etc, and we have presented the way of reporting the emergency to the train driver or crew, control room, outside networks which could be used by passengers in vehicle, station, railroad line. Based on these, we have analyzed the conduct of emergency action in length of time when emergency happens in railway and high-speed railway, and studied the method of which passengers could be guided safely and escape from the scene of the accident.

  • PDF

A Capacity of Refuge area in Multiple Occupancy Building with Underground Facility (지하연계복합건축물의 피난 안전구역 면적 산정)

  • Kim, Jong-Sung;Kim, Woon-Hyung;Lee, Yong-Jae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.272-276
    • /
    • 2011
  • 최근 발생한 부산 해운대 화재 이후 피난 활동이 제한적인 고층 건축물의 화재 안전에 대한 관심이 증대되고 있다. 그러나 현행 규정은 50층 이상의 초고층 건축물을 대상으로 하고 있으며 상대적으로 준 초고층 건축물에 대한 제도적 기반과 연구가 미비한 실정이다. 따라서 본 연구에서는 지하연계복합건축물에 관한 피난 안전구역면적 산정 기준에 대한 적용성을 분석하고자 국외의 관련 기준과 비교 분석하였다. 그 결과, 수용 인원에 관한 기준은 홍콩, 한국, 싱가포르, 중국 순으로 강화 적용하고 있으며 피난안전구역의 면적은 싱가포르의 경우 전체 수용 인원의 50% 이상과 1명당 $0.3m^2$을 전제로 하는 피난안전구역의 면적 기준이 국내의 각 층별 1/10의 면적의 합과 동일한 것으로 분석되었다.

  • PDF

Disaster Management and Disaster Medical Improvement in Underground Space (서울시 지하공간 재난관리 및 재난의료 개선방안)

  • Bae, Yoonshin;Park, Jihye
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.2
    • /
    • pp.110-122
    • /
    • 2011
  • In this study, the disaster management and disaster medical improvement was described in underground space(specifically underground shopping center) in case of fire disaster occurred. Firstly, statue and system was discussed concerning building law, safety, fire services, refuge. The underground in Seoul management is classified as to space and form and management agent is different according to the type form. Because the difficulty of emergency rescue arises due to individual management system unified system needs to be established and improvement of facility management agent is necessary. For the patient to be transfer on the ground, corporation between command head quarter and emergency rescue team are essential. And disaster information and emergency medical information are also need to be considered. Therefore, effective countermeasures for emergency saving is urgent considering distribution of medical institution and medical treatment.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.