• Title/Summary/Keyword: refrigeration storage

Search Result 357, Processing Time 0.027 seconds

Transient Response of a Stratified Thermal Storage Tank to the Variation of Inlet Temperature

  • Yoo, Ho-Seon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.14-26
    • /
    • 1998
  • This paper deals with approximate analytical solutions for the two-region one-dimensional model describing the charging process of stratified thermal storage tanks at variable inlet temperature with momentum-induced mixing. An arbitrarily increasing inlet temperature is decomposed into inherent step changes and intervals of continuous change. Each continuous interval is approximated as a finite number of piecewise linear functions, which admits an analytical solution for perfectly mixed region. Using the Laplace transform, the temperature profiles in plug flow region with both the semi-infinite and adiabatic ends are successfully derived in terms of well-defined functions. The effect of end condition on the solution proves to be negligible under the practical operating conditions. For a Quadratic variation of inlet temperature, the approximate solution employing a moderate number of pieces agrees excellently with the exact solution.

  • PDF

A Study on Thermal Stratification Characteristics and Useful Rate of Hot Water in Thermal Storage Tank during Hot Water Extraction Process (온수 추출과정 동안 축열조 내의 열성층 특성 및 온수 이용률에 관한 연구)

  • 장영근;박정원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.503-511
    • /
    • 2002
  • Heat flow characteristics during hot water extraction process was studied experimentally. Data were taken at various outlet port type for the fixed inlet port type, inlet-outlet temperature differences and mass flow rates. In this study, the temperature distribution in a storage tank and an outlet temperature were measured to predict a degree of stratification in the storage tank, and a useful rate of hot water was analysed with respect to the variables dominating a extraction process. Experimental results show that the degree of stratification and useful rate of hot water are all high in a low flow rate in case of using modified distributor I (MDI) as the outlet port type.

Integral Approximate Solutions to a One-Dimensional Model for Stratified Thermal Storage Tanks (성층화된 축열조의 1차원모델에 대한 적분 근사해)

  • Chung, Jae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.468-473
    • /
    • 2010
  • This paper deals with approximate integral solutions to the one-dimensional model describing the charging process of stratified thermal storage tanks. Temperature is assumed to be the form of Fermi-Dirac distribution function, which can be separated to two sets of cubic polynomials for each hot and cold side of thermal boundary layers. Proposed approximate integral solutions are compared to the previous works of the approximate analytic solutions and show reasonable agreement. The approach, however, has benefits in mathematical difficulties, complicated solution form and unstable convergence of series solution founded in the previous analytic solutions. Solutions for a semi-infinite region, which have simple closed form solutions, give close agreement to those for a finite region. Thermocline thickness is obtained in closed form and shows proportional behavior to the square root of time and inverse proportional behavior to the square root of flow rate.

The Study on Cooling Load Forecast using Neural Networks (신경회로망을 이용한 냉방부하예측에 관한 연구)

  • 신관우;이윤섭
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.8
    • /
    • pp.626-633
    • /
    • 2002
  • The electric power load during the peak time in summer is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system etc. are used to settle this problem. In this study, the method of estimating temperature and humidity to forecast the cooling load of ice storage system is suggested. And also the method of forecasting the cooling load using neural network is suggested. For the simulation, the cooling load is calculated using actual temperature and humidity, The forecast of the temperature, humidity and cooling load are simulated. As a result of the simulation, the forecasted data is approached to the actual data.

The Study on Cooling Load Forecast of an Unit Building using Neural Networks

  • Shin, Kwan-Woo;Lee, Youn-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.4
    • /
    • pp.170-177
    • /
    • 2003
  • The electric power load during the summer peak time is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice storage system and heat pump system etc. are used to settle this problem. In this study, the method of estimating temperature and humidity to forecast the cooling load of ice storage system is suggested. The method of forecasting the cooling load using neural network is also suggested. The daily cooling load is mainly dependent on actual temperature and humidity of the day. The simulation is started with forecasting the temperature and humidity of the following day from the past data. The cooling load is then simulated by using the forecasted temperature and humidity data obtained from the simulation. It was observed that the forecasted data were closely approached to the actual data.

A Study on Heat Recovery Characteristics of Porous Media According to Periodic Oscillating Flows (주기적 왕복유동에 의한 축열매체의 열회수 특성에 관한 연구)

  • Han, Hwa-Taik;Shin, Min-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.175-182
    • /
    • 2007
  • The objective of the present study is to investigate the heat storage characteristics of a packed bed according to periodically oscillating flows. Experiments have been performed to measure transient temperature distributions in solid and fluid Phases of the porous media. A simplified analytical model has been developed with intra-particle and dispersion effects neglected, and non-dimensional parameters have been derived. The transient temperature distributions according to the simplified numerical model agree well with the experimental results. Heat storage efficiencies defined in two different ways are obtained for various time periods and face velocities.

The Effects of Additives on the Thermal Properties of a Clathrate Compound(I) -The Case of Ethanol- (포접화합물의 열물성에 미치는 첨가제의 효과(I) -TMA 물계 포접화합물에 Ethanol을 첨가한 경우-)

  • 김진흥;정낙규;김석현;김창오;강승현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.258-264
    • /
    • 2004
  • The ice thermal storage system is to use consolation latent heat of water. But, supercooling phenomenon of water during phase change is to increase the cooling capacity and to decrease COP of the refrigerator. Furthermore, this causes the operation cost of system to increase and the efficiency of energy to decrease. Therefore, the better thermal storage material than the water is required. The purpose of this study is to improve supercooling characteristics and thermal properties of TMA 30wt% clathrate by using Ethanol.

Dietary Salmonella lysate affect on the antioxidant system(freshness) of broiler meats during 4$^{\circ}$C refrigeration (Salmonella lysate 첨가 사료가 저장중 계육 항산화계(신선도)에 미치는 영향)

  • Lee, Beom-Gyu;Im, Jin-Taek;Park, In-Gyeong;Choe, Do-Yeol;Choe, Jun-Yeong;Go, Tae-Song
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2006.11a
    • /
    • pp.60-61
    • /
    • 2006
  • Effect of dietary salmonella lysate in broiler chicks inoculated with Salmonella typhimurium on the antioxidant system(freshness) of broiler meats during 4$^{\circ}$C refrigeration was investigated. In Pectoral and leg muscle, regardless experimental diets, as the refrigeration day passed, CuZnSOD activity decreased gradually, while at 7d MnSOD activity and peroxide level raised and then lowered at 14d. MnSOD and peroxidase activity, however, had differed according to experimental diets. The results indicated that antioxidant system of broiler meats will be changed according to experimental diets(nutrients). As the CuZnSOD, MnSOD and peroxidase activity are responsible for proteolysis of muscle protein, it was concluded that change of antioxidant system during 4$^{\circ}$C storage explain the biological activity(freshness) of broiler meats.

  • PDF

Effecs of Dipping and Preheating Treatments on Quality of Potato Slices during Cold Storage (감자 슬라이스의 냉장 중 품질변화에 대한 침지용액과 예열처리의 영향)

  • 정현미;이귀주
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.6 no.3
    • /
    • pp.325-333
    • /
    • 1996
  • Potato slices were dipped in calcium choreide ar chitosan solutions or and preheated in each of these solutions. In order to prevent the quality deterioration while they were refrigerated for 4 weeks at 5$^{\circ}C$ Changes in degree of browning and other quality factors were determined while they were refrigerated for 4 weeks at 5$^{\circ}C$ During refrigeration, L values were decreased and optical density (A420) were increased. But L values were increased and A420 were decreased by dipping or preheating. The contents of vitamin C were decreased. however, the loss of vitmin C were the lowest in calcium chloride treaed potato slices(CaPS). And there were no combined effects of dipping and preheating during refrigeration. However, protein content of CaPS increased but that of other treated potato slices were decreased compared to that of control. With respect to changes in other physicochemical qualit, pH increased in chitosan treated potato slices(ChPS) and loss of weight was the lowest in combined with preheating. From these results, it was considered that the shelf-life of potato slices could be increased by dipping or-and preheating.

  • PDF

The maintenance record of the KSTAR helium refrigeration system

  • Moon, K.M.;Joo, J.J.;Kim, N.W.;Chang, Y.B.;Park, D.S.;Kwag, S.W.;Song, N.H.;Lee, H.J.;Lee, Y.J.;Park, Y.M.;Yang, H.L.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.6-9
    • /
    • 2013
  • Korea Superconducting Tokamak Advanced Research (KSTAR) has a helium refrigeration system (HRS) with the cooling capacity of 9 kW at 4.5 K. Main cold components are composed of 300 tons of superconducting (SC) magnets, main cryostat thermal shields, and SC current feeder system. The HRS comprises six gas storage tanks, a liquid nitrogen tank, the room temperature compression sector, the cold box (C/B), the 1st stage helium distribution box (DB#1), the PLC base local control system interconnected to central control tower and so on. Between HRS and cold components, there's another distribution box (DB#2) nearby the KSTAR device. The entire KSTAR device was constructed in 2007 and has been operated since 2008. This paper will present the maintenance result of the KSTAR HRS during the campaign and discuss the operation record and maintenance history of the KSTAR HRS.