• Title/Summary/Keyword: refraction

Search Result 735, Processing Time 0.03 seconds

Comparison of Clinical Results of Excimer Laser Correction of Myopia and Compound Myopic Astigmatism Using VISX 20/20B $VisionKey^{TM}$ (VISX 20/20B $VisionKey^{TM}$ 엑시머레이저의 version 4.01 software를 이용한 근시교정술 및 근시성난시교정술의 임상성적 비교)

  • Lee, Sang-Bumm;Bae, Sang-Bok
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.1
    • /
    • pp.55-65
    • /
    • 2000
  • Purpose: To compare the efficacy, predictability, stability and safety of excimer laser photorefracive keratectomy(PRK) for myopia and photoastigmatic refractive keratectomy(PARK) for compound myopic astigmatism. Methods: Two-hundred and three eyes(l18 eyes < -7D spherical equivalent, 85 eyes ${\geq}$ -7D spherical equivalent) received excimer laser correction for compound myopic astigmatism and 152 eyes(116 eyes < -7D, 36 eyes ${\geq}$ -7D) for simple myopia. A VISX 20/20B $VisionKey^{TM}$ excimer laser was used to perform either PARK or PRK. Visual acuity with and without correction, refraction, IOP, corneal haze, and topography were evaluated at 1, 3, 6, and 12 months postoperatively. All patients were followed up for more than 12 months. Results: Postoperative refraction were generally stable after 3 months without significant early overcorrection. At 12 months, 110(94.8%) eyes that underwent PRK and 104(88.1%) eyes that underwent PARK achieved UCVA of 20/30 or better in the group who had lower than -7D correction. For eyes treated with -7D or more, these figures were 31(86.1%) eyes after PRK and 57(67.1%) eyes after PARK. The incidences of within 1D of plano refraction at 1 year follow-up were 97.4% after PRK and 93.2% after PARK in the group who had lower than -7D correction. For eyes treated with -7D or more, these figures were 80.6% after PRK and 70.6% after PARK. Conclusions Myopia with or without astigmatism was successfully treated in most of the eyes using PRK or PARK with VISX 20/20B $VisionKey^{TM}$ excimer laser. The predictability and stability of the postoperative refraction during the first 12 months seem to be quite reliable. Further improvement of excimer laser system and software should increase the clinical outcomes and safety of refractive procedures.

  • PDF

Comparison of Central and Peripheral Refraction in Myopic Eyes after Corneal Refractive Surgery and Emmetropes (굴절교정수술을 받은 근시안과 정시안에서 중심부 및 주변부의 굴절력 비교)

  • Kim, Jeong-Mee;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.157-165
    • /
    • 2015
  • Purpose: To evaluate changes in central and peripheral refraction along the horizontal visual fields in myopic corneal refractive surgery group compared with emmetropes. Methods: One hundred twenty eyes of 60 subjects ($23.56{\pm}2.54$ years, range: 20 to 29) who underwent myopic refractive surgery and 40 eyes of 20 emmetropes ($22.50{\pm}1.74$ years, range: 20 to 25) were enrolled. The central and peripheral refractions were measured along the horizontal meridianat $5^{\circ}$, $10^{\circ}$, $15^{\circ}$, $20^{\circ}$, $25^{\circ}$ in the nasal and temporal areas using an open-field autorefractor. For analysis of post-op group, the group was classified by pre-op spherical equivalents of < -6.00 D and ${\geq}-6.00D$ as two post-op groups. Results: Pre-op spherical equivalent was $-4.56{\pm}0.92D$ (rang: -2.50 to -5.58 D) in post-op group 1, and $-7.09{\pm}0.96D$ (rang: -6.00 to -9.00 D) in post-op group 2. Spherical equivalent (M) in the emmetropes ranged from $-0.20{\pm}0.22D$ at center to $-0.64{\pm}0.83D$ at $25^{\circ}$ in the temporal visual field and to $-0.20{\pm}0.67D$ at $25^{\circ}$ in the nasal visual field; M in post-op group 1 ranged from $-0.16{\pm}0.29D$ at center to $-5.29{\pm}1.82D$ at $25^{\circ}$ in the temporal visual field and to $-4.48{\pm}1.88D$ at $25^{\circ}$ in the nasal visual field; M in post-op group 2 ranged from $-0.20{\pm}0.32D$ at center to $-7.98{\pm}2.08D$ at $25^{\circ}$ in the temporal visual field and to $-7.90{\pm}2.26D$ at $25^{\circ}$ in the nasal visual field. Among the three groups, there was no significant difference in M at central visual field (p=0.600) and at $5^{\circ}$ in the temporal visual field (p=0.647), whereas, there was significant difference in M at paracentral and peripheral visual field (p=0.000). Conclusions: Emmetropes had relatively constant refractive errors throughout the central and peripheral visual field and showed myopic peripheral defocus along the horizontal visual field. On the other hand, in myopic corneal refractive surgery group, there were significant differences in refractive errors between the central and peripheral visual field compared with differences in the central and peripheral refraction patterns of emmetropes.

Effects of Myopia Alleviation Lenses in accordance with Parents' Refractive Errors (부모의 굴절이상에 따른 근시완화렌즈 효과)

  • Cho, Yoon Chul;Kang, JoongGu;Leem, Hyun Sung
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.569-577
    • /
    • 2018
  • Purpose : The study looked at how effective each group wearing MyoVison lens, MC lens, and Single Vision lensdepending on their parents' myopia condition. Methods : The study observed the changeof spherical equivalent among customers, who visited between January 2010 and December 2016,of an optical shop in Incheon Metropolitan City. And we observed MyoVision 152 eyes, MC Lens 86 eyes and Single Vision lens 270 eyes. This study was conducted using SPSS ver18, which analyzes the changes in average values of MyoVision, MC Lens, and Single Vision for a year.In each group, the differences in the group were compared using the Paired T-test and then one-way ANOVA (post-hoc; Bonferroni) Results : Group-to-group comparisons showed that MyoVision and MC Lens have a shorterinhibition than Single Vision. In particular, MyoVisionand MC Lens showed different relief effects depending on the degree of refraction of parents.When both parents had normal refractive, the change between MyoVision and Single Vision lens was $-0.35{\pm}0.05D$. When the father had a refraction MC lens were $-0.36{\pm}0.14D$ more effective than Single Vision. When only the mother had refraction, the mean value between MyoVision and Single Vision lens was $-0.37{\pm}0.06D$, and the mean between MC lens and Single Vision lens was $-0.38{\pm}0.08D$. And when both parents had refraction problems, the mean value change between MyoVision and Single Vision lens was $-0.28{\pm}0.07D$, and $-0.31{\pm}0.07D$, respectively. Conclusion : MyoVision and MC Lens appeared to have no effect on the functions of mitigating myopia in within group comparisons, but MyoVision and MC Lens showed reducing myopia than Single Vision in between group.

Adaptive Error Compensation of Heterodyne Laser Interferometer using DFNN (DFNN을 이용한 헤테로다인 레이저 간섭계의 적응형 오차 보정)

  • Heo, Gun-Haeng;Lee, Woo-Ram;You, Kwan-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1042-1047
    • /
    • 2008
  • As an ultra-precision measurement system the heterodyne laser interferometer plays an important role in semiconductor industry. However the errors of environment and nonlinearity which are caused by air refraction and frequency-mixing separately reduce the accuracy of displacement measurement. In this paper we propose a DFNN(data fusion and neural network) method for error compensation. As a hybrid method of data fusion and neural network, DFNN method reduces the environmental and nonlinear error simultaneously. The effectiveness of the proposed error compensation method is proved through experimental results.

Application of Iterative Procedure to the wave Field with Energy Dissipation Area (에너지 감쇠역을 포함하는 파랑장에 대한 반복기법의 적용)

  • 윤종태
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.120-127
    • /
    • 1998
  • An Elliptic model for calculating the combined refraction/diffraction of monochromatic linear waves is developed, including a term which allows for the dissipation of wave energy. Conjugate gradient method is employed as a solution technique. Wave height variations are calculated for localized circular and rectangular dissipation areas. It is shown that the numerical results agree very well with analytical solution in the case of circular damping region. The localized dissipation area creates a shadow region of low wave energy and the recovery of wave height by diffraction occurs very slowly with distance behind the damping region.

  • PDF

The optical properties on the human model eye (모형 안의 광학적 성능)

  • Lim, Hyeonseon;Ji, Taeksang;Kim, Bonghwan;Kim, Sejin;Yoon, Sungro
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.203-207
    • /
    • 2002
  • In this study, by using the eye model of NAVARRO, KOOIJMAN, MAHKICHOONG, the properties of optical system are reserched in a finite ray tracing method, when ametropia is corrected by glasses or contact lens, this study is useful as a reference. Also, when Auto-refractometer for refraction test and Keratomeler are designed, these eye models can be used.

  • PDF

Study of Dynamics of Allyl Chloride-2-Butanone Binary System Using Time Domain Reflectometry

  • Sudake, Y.S.;Kamble, S.P.;Patil, S.S.;Khirade, P.W.;Mehrotra, S.C.
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.1
    • /
    • pp.20-27
    • /
    • 2012
  • Complex permittivity spectra of Allyl Chloride (AC), 2-Butanone (2-BU) and their binary mixtures over the entire range of concentration were obtained using the Time Domain Reflectometry (TDR) technique in microwave frequency range at various temperatures. Static dielectric constant and relaxation time are obtained from complex permittivity spectra. Density ($\rho$) and refractive index ($n_D$) are also measured. These parameters are used to determine excess dielectric constant, excess inverse relaxation time, excess molar volume, excess molar refraction, polarity, Bruggeman factor and thermodynamic parameters viz. enthalpy of activation and entropy of activation. The values of static dielectric constant and relaxation time increases while density and refractive index decreases with the percentage of 2-Butanone in Allyl Chloride increases. Excess parameters were fitted to a Redlich-Kister equation.

Development of Particle Detection Chamber for Particle Counter (미세 입자 계수기를 위한 입자 검출 챔버 개발)

  • Ohm, Woo Yong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.219-224
    • /
    • 2014
  • In this paper, we study the scattering characteristics of particle using Mie scattering based on various variables such as particle size and refraction of particle, wavelength of laser and angle of receiver to get diffuse light. And we consist a optical system for particle detection, then analyzed the characteristics of the optical system. And based on these characteristics, we develop a particle detection chamber for particle counter and shows experiment result.

The Application of Geophysical Prospecting for Detecting Substructure and Boundary of Layer In Limestone Area (석회암 지역의 기반암 및 경계면 조사를 위한 지구물리 탐사법의 적용)

  • Suh, Beak-Su;Lee, Duk-Jae
    • Journal of Industrial Technology
    • /
    • v.20 no.A
    • /
    • pp.285-293
    • /
    • 2000
  • In 1970's, the analysis of shallow substructure was the interests of geological engineering and environmental problems. And seismic refraction method was applied to detect those structures. From 1980's, digital electric industry is rapidly developed and high resolution prospecting equipment is supplied. And seismic reflection method is applied to achieve various data gathering and data analysis. In this study, geophysical prospecting method is applied to calculate the basic data of limestone yield production. Seismic shallow reflection method is used to detect the depth of bedrock and electrical resistivity method is used to detect of limestone layer boundary.

  • PDF

Optical Waveguiding in the Polymerized Organic Films (유기물 박막에서의 광도파 현상)

  • 박홍준;권영세
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.5
    • /
    • pp.5-11
    • /
    • 1982
  • The dielectric slab waveguide is fabricated on the slide glass or oxidized silicon wafer, by spin coating polyurethane, epoxy or photoresist, and the phenomenon of dielectric waveguiding is oboerved. Using the fact that the refractive index of K.P.R. is larger than that of polyurethane, thin film prism with two layered structure is fabricated, and the refraction of light is observed.

  • PDF