Peripheral Blood Flow Velocity and Peripheral Pulse Wave Velocity Measured Using a Clip-type Pulsimeter Equipped with a Permanent Magnet and a Hall Device

  • Kim, Keun-Ho;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제20권1호
    • /
    • pp.47-51
    • /
    • 2015
  • We measured radial arterial pulse signals using a prototype of a clip-type pulsimeter equipped with a permanent magnet and a Hall device, which produced signals through a voltage-detecting circuit. The systolic peak time and the reflective peak time for a temporally pulsed signal were analyzed for an arbitrary pulse wave at one position of a small permanent magnet. The measured value of the peripheral pulse wave velocity was about 1.25-1.52 m/s, demonstrating the accuracy of this new method. To measure the peripheral blood flow velocity, we simultaneously connected the radial artery pulsimeter to a photoplethysmography meter. The average value of the peripheral blood flow velocity was about 0.27-0.50 m/s.

자성홀소자를 이용한 집게형 맥진기의 유효성 평가를 위한 허맥과 실맥 로지스틱 회귀식 탐색 (Investigation of Logisitic Regression Equation of Vacuous Pulse and Replete Pulse for Efficacy Evaluation of Clip-type Pulsimeter by using Magnetic Hall Device)

  • 유준상;장세진;선승호;홍유식;이상석
    • 대한한의진단학회지
    • /
    • 제17권1호
    • /
    • pp.63-76
    • /
    • 2013
  • The aims of this study are to investigate a logisitic regression equation of the vacuous pulse and the replete pulse for efficacy evaluation of clip-type pulsimeter by using magnetic Hall device. To evaluate the efficacy of clip-type pulsimeter by using magnetic Hall device as sensing the minute movement of a radial artery, one research clinical trial have been performed. The number of subject was 120, the clinical data of patients did treated with a normal statistical method. The systolic peak amplitude, the reflective peak amplitude and time, and the notch peak amplitude and time are analyzed major efficacy parameters to discern the vacuous pulse and the replete pulse. The equations included of five parameters such as systolic peak amplitude, the reflective peak amplitude and time, and the notch peak amplitude and notch amplitude time for determination of the vacuous pulse and the replete pulse were deducted by statistical logistic regression method. It suggests that the logistic regression equations are possible to develop the oriental algorithm for pulse diagnosis.

비동일면 치료 시 자체 제작한 Kw-infrared Reflective Marker의 유용성 평가 (Evaluation of the Usefulness of the Self-developed Kw-infrared Reflective Marker in Non-coplanar Treatment)

  • 권동열;안종호;박영환;송기원
    • 대한방사선치료학회지
    • /
    • 제22권1호
    • /
    • pp.25-32
    • /
    • 2010
  • 목 적: 종양의 움직임을 고려하여 치료할 수 있는 RPM (Real time Position Management, Varian, USA) system을 사용하여 호흡을 고려한 방사선치료 시행 시, 제조사에서 제공하는 적외선 반사체는 일정각도 이상 couch가 회전할 경우 호흡신호 획득이 불가능하다. 이런 단점을 개선하고자 본 저자는 어느 각도에서나 호흡신호를 얻을 수 있는 3차원 적외선 반사체(3D infrared reflective marker)를 자체 개발하여 Kw-반사체라 명하고 그 유용성을 평가 하고자 한다. 대상 및 방법: 호흡신호의 안정성을 측정하기 위해 호흡운동을 재현 할 수 있는 3차원 구동팬텀(3D moving phantom) 위에 3가지 조건(A: couch 0도, 제조사의 반사체 B: couch 0도, Kw-반사체 C: couch 90도, Kw-반사체)의 적외선 반사체를 올려놓고 각각 3분 동안 호흡신호를 획득 하였다. 획득한 호흡신호는 호흡분석 프로그램(Labview ver 7.0)을 통해 최고값(peak value), 최저값(valley value), 표준편차(standard deviation), 변동값(variation value), 진폭값(amplitude value)을 획득하였다. 타겟의 회전 오차와 타겟의 이동범위를 알아보기 위해 3차원 구동팬텀 위에 B.B팬텀을 올려놓고 온-보드 영상장치(OBI)로 couch 0도와 90도 이미지를 획득한 후 B.B팬텀 중심에 위치한 ball bearing의 X, Y, Z값(mm)을 획득하였다. 결 과: 호흡신호를 분석한 결과 최고점에서 표준편차가 A: 0.002 B: 0.002 C: 0.003이고 진폭에 대한 호흡의 안정성은 A: 0.15% B: 0.14% C: 0.13%로 Kw반사체는 안정적으로 호흡신호를 얻을 수 있었다. couch 90도 회전 시 타겟인 ball bearing의 평균 회전오차는 X: -1.25 mm Y: -0.45 mm Z: +0.1 mm로 모든 방향에서 평균 1.3 mm 이내이고 타겟의 이동범위 차이도 평균 0.3 mm 이내였다. 결 론: couch가 회전하는 비동일면(Non-coplanar) 치료 시 Kw-반사체로 호흡신호를 얻은 결과 Kw-반사체는 안정적인 호흡신호를 획득할 수 있었고 제조사의 적외선반사체를 대체하기에 충분했다. 타겟의 회전오차와 이동범위 차이가 거의 없어 couch 회전 시 반사체 움직임의 변위가 호흡신호의 scale 및 진폭을 변화시킨 원인임을 알 수 있었다. 향후 couch angle값에 따른 진폭 높이의 변환 값을 연구해 적용한다면 비동일면에 대한 위상기반 gating 치료도 가능 할 것으로 사료된다.

  • PDF

Aging Studies on Conducting Polypyrrole

  • Kaynak, Akif
    • Fibers and Polymers
    • /
    • 제2권4호
    • /
    • pp.171-177
    • /
    • 2001
  • Change of tensile properties, electrical conductivity and microwave shielding of electrochemically synthesized polypyrrole films with time are presented. Highly doped films had good electrical stability, retaining high microwave reflectivity throughout the aging period. Lightly doped films were less stable and partially reflective and absorptive of microwaves. FT-IR spectral observations revealed a progressive increase in intensity of an unsaturated conjugated carbonyl peak, which was not observed in the highly doped films, suggesting that the concentration of the dopant had an influence on mechanism of degradation of conductivity.

  • PDF

The Real-Time Temporal and Spatial Diagnostics of Ultrashort High-Power Laser Pulses using an All-Reflective Single-Shot Autocorrelator

  • Kim, Ha-Na;Park, Seong Hee;Kim, Kyung Nam;Han, Byungheon;Shin, Jae Sung;Lee, Kitae;Cha, Yong-Ho;Jang, Kyu-Ha;Jeon, Min Yong;Miginsky, Sergei V.;Jeong, Young Uk;Vinokurov, Nikolay A.
    • Journal of the Optical Society of Korea
    • /
    • 제18권4호
    • /
    • pp.382-387
    • /
    • 2014
  • An all-reflective, simple noncollinear second harmonic (SH) autocorrelator is described for monitoring the shot-to-shot behavior of ultrashort high-power laser pulses. Two mirrors are used for the dispersion-free splitting of a pulse into two halves. One of the mirrors is able to adjust the delay time and angle between two halves of the laser pulse in a nonlinear crystal. We present the possibility of real-time measurement of the pulse duration, peak intensity (or energy), and the pointing jitters of a laser pulse, by analyzing the spatial profile of the SH autocorrelation signal measured by a CCD camera. The measurement of the shot-to-shot variation of those parameters will be important for the detailed characterization of laser accelerated electrons or protons.

에너지절약형 주택에서의 단열차양 적용과 제어방법에 따른 냉난방부하 분석 (An Analysis of Heating and Cooling Loads by Insulated Shades and Control Method in an Energy Saving Apartment)

  • 권경우;원종서
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.33-38
    • /
    • 2009
  • Energy loss from windows accounts for large scores of heating and cooling loads also in energy saving apartments that is reduced over 30% of total energy consumption. Movable reflective insulations, insulation shutters, blinds, insulated shades are used to reduce energy loads from windows. In this study, energy saving performance of insulated shades was simulated by control methods. According to installation of insulated shades, heating loads were decreased about $10.5{\sim}11.3%$, and cooling loads are decreased about $11.0{\sim}15.5%$ on an energy saving apartment. The heating peak load was reduced about 9.5% by insulated shades, but the cooling peak load is hardly ever decreased. Because in the condition of cooling peak load, latent cooling loads accounts for large score of cooling loads. Difference of the energy loads by a schedule control method and an outdoor detection control was no more than 5% for a base model. In the case of insulated shades with automatic control system, simple time schedule control system would be more efficient than outdoor detection control system that should use several sensors.

  • PDF

에너지절약형 주택에서의 단열차양 적용과 제어방법에 따른 냉난방부하 분석 (An Analysis of Heating and Cooling Loads by Insulated Shades and Control Method in an Energy Saving Apartment)

  • 박선효;권경우;손장열
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.392-397
    • /
    • 2010
  • Energy loss from windows accounts for large scores of heating and cooling loads also in energy saving apartments that is reduced over 30% of total energy consumption. Movable reflective insulations, insulation shutters, blinds, insulated shades are used to reduce energy loads from windows. In this study, energy saving performance of insulated shades was simulated by control methods. According to installation of insulated shades, heating loads were decreased about 10.5~11.3%, and cooling loads are decreased about 29.1~38.3% on an energy saving apartment. The heating peak load was reduced about 9.5% by insulated shades and the cooling peak load was reduced about 25.7~31.5%. In the case of insulated shades with automatic control system, simple time schedule control system would be more efficient than outdoor detection control system that should use several sensors.

손목형 생체신호수집 장치에 대한 연구 (A Study on Wrist Band Type Vital Sign Acquisition Device)

  • 김희훈;김경호
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.857-861
    • /
    • 2016
  • In this study, we proposed a new method that can be measure ECG (Electrocardiography) and PPG (Photoplethysmography) in realtime on the site of the wrist for check the state of health in daily life. For convenience measurement of ECG the lead I method was used on the wrist, and omit the reference junction ECG I was measured in the right hand and the left hand of the potential difference. Then the measured electrocardiogram was amplified by the differential amplifier and the signals were passed HPF, LPF, and BPF filters. For removing the PPG's noise from the Motion artifact and temperature, we apply the reflective photoelectric volume pulse wave measurement method using green LED as a light source. The circuits was designed to be able to check the waveform using higher active amplification method at weak signals. For the validation of our device, the measured signals were compared with E2-KIT on same time. The results shows that the error does not exceed the maximum one, most of the data is confirmed to be issued Peak inspection of the same number.

자기장 측정 홀소자 집게형 맥진기를 이용한 허맥과 실맥 예측 알고리즘 개발 (Development of Prediction Algorithm for Replete Pulse and Vacuous Pulse by using Clip-type Pulsimeter with Hall Device Measuring a Magnetic Field)

  • 이남규;김근호;이상석;유지혜;유준상;선승호;장세진;홍유식
    • 한국자기학회지
    • /
    • 제23권3호
    • /
    • pp.104-109
    • /
    • 2013
  • 소형 영구자석이 부착된 상태에서 요골동맥의 미세한 움직임으로 자기장 변화를 측정하는 홀소자 집게형 맥진기를 개발하였다. 이 맥진기를 통해서 얻은 120명의 임상데이터를 통계적 로지스틱 회귀분석으로 처리하여 허맥과 실맥을 예측하는 알고리즘의 특성을 연구하였다. 요골동맥파의 반사파 시간값과 절흔점 시간값이 허맥과 실맥을 예측할 수 있는 주요인자이였으며, 판별율은 65%이었다. 이로써 한의학적 허맥과 실맥을 예측하고 판별하는 진단지표로 사용할 가능성을 제하였다.