• Title/Summary/Keyword: reference standards

Search Result 772, Processing Time 0.026 seconds

Comparison Between Contrast-Enhanced Computed Tomography and Contrast-Enhanced Magnetic Resonance Imaging With Magnetic Resonance Cholangiopancreatography for Resectability Assessment in Extrahepatic Cholangiocarcinoma

  • Jeongin Yoo;Jeong Min Lee;Hyo-Jin Kang;Jae Seok Bae;Sun Kyung Jeon;Jeong Hee Yoon
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.983-995
    • /
    • 2023
  • Objective: To compare the diagnostic performance and interobserver agreement between contrast-enhanced computed tomography (CECT) and contrast-enhanced magnetic resonance imaging (CE-MRI) with magnetic resonance cholangiopancreatography (MRCP) for evaluating the resectability in patients with extrahepatic cholangiocarcinoma (eCCA). Materials and Methods: This retrospective study included treatment-naïve patients with pathologically confirmed eCCA, who underwent both CECT and CE-MRI with MRCP using extracellular contrast media between January 2015 and December 2020. Among the 214 patients (146 males; mean age ± standard deviation, 68 ± 9 years) included, 121 (56.5%) had perihilar cholangiocarcinoma. R0 resection was achieved in 108 of the 153 (70.6%) patients who underwent curative-intent surgery. Four fellowship-trained radiologists independently reviewed the findings of both CECT and CE-MRI with MRCP to assess the local tumor extent and distant metastasis for determining resectability. The pooled area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of CECT and CE-MRI with MRCP were compared using clinical, surgical, and pathological findings as reference standards. The interobserver agreement of resectability was evaluated using Fleiss kappa (κ). Results: No significant differences were observed between CECT and CE-MRI with MRCP in the pooled AUC (0.753 vs. 0.767), sensitivity (84.7% [366/432] vs. 90.3% [390/432]), and specificity (52.6% [223/424] vs. 51.4% [218/424]) (P > 0.05 for all). The AUC for determining resectability was higher when CECT and CE-MRI with MRCP were reviewed together than when CECT was reviewed alone in patients with discrepancies between the imaging modalities or with indeterminate resectability (0.798 [0.754-0.841] vs. 0.753 [0.697-0.808], P = 0.014). The interobserver agreement for overall resectability was fair for both CECT (κ = 0.323) and CE-MRI with MRCP (κ = 0.320), without a significant difference (P = 0.884). Conclusion: CECT and CE-MRI with MRCP showed no significant differences in the diagnostic performance and interobserver agreement in determining the resectability in patients with eCCA.

Improvement of the Thinning System by Exploring the Stand Density Management Criteria for Chamaecyparis obtusa in South Korea (편백림의 임분밀도 관리 기준 탐색을 통한 시업체계 개선)

  • Su Young Jung;Kwang Soo Lee;Hyun Soo Kim;Joon Hyung Park
    • Journal of Korean Society of Forest Science
    • /
    • v.113 no.1
    • /
    • pp.131-142
    • /
    • 2024
  • The purpose of this study was to estimate the optimal stand density criteria for each growth stage of Chamaecyparis obtusa (Siebold & Zucc.) Endl. to achieve the timber production goal for cypress forests and develop an optimal silvicultural system for forest thinning. A relative yield index (Ry) value of 0.75, presented as a stand density management criterion index, was estimated by analyzing the relationship characteristics between the composition ratio and stand density of slender trees from 216 sample plots of the recruited cypress forests. The analysis of the feasibility of achieving each production target in the existing silvicultural system for C. obtusa revealed that the growth rate according to the parameters of forest land productivity, such as site index and thinning intensity according to the increase in age, was not properly reflected. In the thinning system for each timber production target analyzed in this study, 353 high-quality large hardwoods from 498.1 m3/ha, 703 high-quality medium hardwoods from 376.2 m3/ha, and 1,758 small-diameter hardwoods from 249.5 m3/ha could be harvested. Although the silvicultural system prepared on the basis of the results of this study cannot be uniformly applied according to various management goals, this study is meaningful in that it presents empirical reference standards based on the stand density management diagram that reflects the growth characteristics of cypress forests in South Korea.

Human Risk Assessment for Exposure to Heavy Metals within Finishing Materials of Playground Facilities for Children in Gwangju (광주지역 어린이 놀이시설 마감재의 중금속 노출에 의한 인체 위해성평가)

  • Sang-Hoon Yoon;So-Young Kim;Eun Cho;Tae-Hui Nam;Jin-Hwan Park;Hwa-Jin Kong;Ki-Won Lee;Gwang-Yeob Seo;Jeong-Hun Park;Kyoung-Woo Min
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.2
    • /
    • pp.146-156
    • /
    • 2024
  • Background: Children who use playground facilities are exposed to potential risks due to the high concentration of heavy metals contained in the finishing materials of facilities in children's playgrounds. Objectives: The purpose of this study was to investigate the concentration of heavy metals in the finishing materials of outdoor children's playgrounds where harmful heavy metals exist in Gwangju and to conduct human risk assessment for children and adults by age to find the risks and limitations. Methods: The bottom and top layers of double-painted paint were peeled off and collected together from the finishing materials of children's play facilities such as slides, swings, and seesaws in 147 children's parks in Gwangju. Heavy metals were analyzed using ICP-OES, etc., and human risk assessment was performed using the concentrations of heavy metals. Results: Based on 1.0E-04, which requires legal regulation, CTE was found to pose a carcinogenic risk for preschool children and no carcinogenic risk for the rest of the age groups. However, RME showed that both men and women of all ages had a carcinogenic risk. For reference, when the carcinogenic risk was based on 1.0E-06, CTE was found to pose a carcinogenic risk from infants to elementary school students, and RME was found to have a carcinogenic risk in all age groups. It was judged that there is a non-carcinogenic risk if the non-carcinogenic risk exceeds 1 based on the hazard index (HI) 1. In CTE, there was no non-carcinogenic risk, and RME for preschooler males (1.49E+00) and females (1.56E+00) were found to have non-carcinogenic risk. Conclusions: This study was meaningful in that it examines the differences in the current management of heavy metals concentration standards and potential carcinogenic and non-carcinogenic risks to the human body and discusses the relationship between heavy metals and human health effects.

A Study on Metadata Design for Managing Person and Organization Names in the National Debt Redemption Movement Digital Archive (국채보상운동 디지털 아카이브의 개인/단체명 관리를 위한 메타데이터 설계에 관한 연구)

  • Sangeun Han;Seulki Do
    • Journal of the Korean Society for information Management
    • /
    • v.41 no.1
    • /
    • pp.509-536
    • /
    • 2024
  • The purpose of this study is to develop a metadata AP for managing the person and organization name authority data in the National Debt Redemption Movement Digital Archive, a small-scale digital archive. The design principles and core metadata elements were derived by analyzing person/organization(group or corporateBody) metadata standards, implementation practices, and guidelines of libraries and archives, and mapped to the National Debt Redemption Movement person/organization name thesaurus data and the Wikidata Linked Metadata Model, resulting in 10 elements in the identification area, 14 elements in the content area, 8 elements in the relationship area, and 4 elements in the control area. A simple structure schema was applied so that it can be applied even in small organizations, and for interoperability, the schema was proposed with reference to DublinCore and SKOS schemes, and the applicability was confirmed based on actual data. The results of this study can be utilized as a basis for institutions that recognize the importance of data management but have difficulty in applying it in practice, when they want to prepare a system for managing their own authority data.

Overall and cardiovascular mortality according to 10-year cardiovascular risk of the general health checkup: the Kangbuk Samsung Cohort Study

  • Youshik Jeong;Yesung Lee;Eunchan Mun;Eunhye Seo;Daehoon Kim;Jaehong Lee;Jinsook Jeong;Woncheol Lee
    • Annals of Occupational and Environmental Medicine
    • /
    • v.34
    • /
    • pp.40.1-40.9
    • /
    • 2022
  • Background: According to the occupational accident status analysis in 2020, of 1,180 occupational deaths, 463 were caused by cardiovascular disease (CVD). Workers should be assessed for CVD risk at regular intervals to prevent work-related CVD in accordance with the rules on occupational safety and health standards. However, no previous study has addressed risk and mortality. Therefore, this longitudinal study was conducted to evaluate the relationship between 10-year cardiovascular risk of the general health checkup and mortality. Methods: The study included 545,859 participants who visited Kangbuk Samsung Total Healthcare Centers from January 1, 2002, to December 31, 2017. We performed 10-year cardiovascular risk assessment for the participants and the risk was divided into 4 groups (low, moderate, high, and very high). The study used death data from the Korea National Statistical Office for survival status as an outcome variable by December 31, 2019, and the cause of death based on the International Classification of Diseases, 10th Revision (ICD-10) was identified. Statistical analysis was performed using Cox proportional hazards regression analysis, and the sum of the periods from the first visit to the date of death or December 31, 2019, was used as a time scale. We also performed a stratified analysis for age at baseline and sex. Results: During 5,253,627.9 person-years, 4,738 overall deaths and 654 cardiovascular deaths occurred. When the low-risk group was set as a reference, in the multivariable-adjusted model, the hazard ratios (HRs) (95% confidence interval [CI]) for overall mortality were 3.36 (2.87-3.95) in the moderate-risk group, 11.08 (9.27-13.25) in the high-risk group, and 21.20 (17.42-25.79) in the very-high-risk group, all of which were statistically significant. In cardiovascular deaths, the difference according to the risk classification was more pronounced. The HRs (95% CI) were 8.57 (4.95-14.83), 38.95 (21.77-69.69), and 78.81 (42.62-145.71) in each group. As a result of a subgroup analysis by age and sex, the HRs of all-cause mortality and cardiovascular mortality tended to be higher in the high-risk group. Conclusions: This large-scale longitudinal study confirmed that the risk of death increases with the 10-year cardiovascular risk of general health checkup.

A Comprehensive Computer Program for Monitor Unit Calculation and Beam Data Management: Independent Verification of Radiation Treatment Planning Systems (방사선치료계획시스템의 독립적 검증을 위한 선량 계산 및 빔데이터 관리 프로그램)

  • Kim, Hee-Jung;Park, Yang-Kyun;Park, Jong-Min;Choi, Chang-Heon;Kim, Jung-In;Lee, Sang-Won;Oh, Heon-Jin;Lim, Chun-Il;Kim, Il-Han;Ye, Sung-Joon
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.231-240
    • /
    • 2008
  • We developed a user-friendly program to independently verify monitor units (MUs) calculated by radiation treatment planning systems (RTPS), as well as to manage beam database in clinic. The off-axis factor, beam hardening effect, inhomogeneity correction, and the different depth correction were incorporated into the program algorithm to improve the accuracy in calculated MUs. A beam database in the program was supposed to use measured data from routine quality assurance (QA) processes for timely update. To enhance user's convenience, a graphic user interface (GUI) was developed by using Visual Basic for Application. In order to evaluate the accuracy of the program for various treatment conditions, the MU comparisons were made for 213 cases of phantom and for 108 cases of 17 patients treated by 3D conformal radiation therapy. The MUs calculated by the program and calculated by the RTPS showed a fair agreement within ${\pm}3%$ for the phantom and ${\pm}5%$ for the patient, except for the cases of extreme inhomogeneity. By using Visual Basic for Application and Microsoft Excel worksheet interface, the program can automatically generate beam data book for clinical reference and the comparison template for the beam data management. The program developed in this study can be used to verify the accuracy of RTPS for various treatment conditions and thus can be used as a tool of routine RTPS QA, as well as independent MU checks. In addition, its beam database management interface can update beam data periodically and thus can be used to monitor multiple beam databases efficiently.

  • PDF

Nutritional and Health Status of the Elderly Living in Songnam - I. Anthropometric Measurements and Biochemical Nutritional Status - (성남지역 노인의 영양 및 건강상태 조사 I. 신체 계측 및 생화학적 영양상태)

  • 권종숙;이홍재
    • The Korean Journal of Food And Nutrition
    • /
    • v.16 no.4
    • /
    • pp.310-320
    • /
    • 2003
  • To study the nutritional and health status of the elderly in Songnam, the anthropometic measurments, fat composition of body(FAT), blood pressure(BP) and blood test for analyzing biochemical indies of the elderly in seongnam were carried out in 338 free-living elderly (161 men, 177 women) aged from 58 to 92. Anthropometric measurements and blood pressure were assessed, and body fat was analyzed by BI(Bioelectrical Impedence) method. Biochemical measurements including blood glucose(BG), GPT, serum total cholesterol(TC) and albumin(AL) were analyzed. Average heights of the subjects were lower than the standards established in the Korean Recommended Dietary Allowances, and average weights were similar to the standards. FAT were significantly higher in women(36.4%) than men(27.7%), and both groups showed higher values than the reference. Mean systolic BP levels of men and women were 153.3mmHg and 153.7mmHg, and diastolic BP levels were 87.5mmHg and 86.0mmHg, respectively, and there were no significant differences between the sex. Mean BG levels of men and women were 115.9mg/㎗ and 123.7mg/㎗, respectively, and there were no significant differences between the sex and among the age groups. Mean GPT levels of men and women were 19.4unit and 18.1unit, respectively, and women older than 75 years showed significanly low levels of GPT compared to other women's age groups. Mean TC levels of men and women were 186.0mg/㎗ and 206.6mg/㎗, respectively, and significantly higher TC levels were shown in women than men. Mean AL levels of men and women were 4.8g/㎗ and 4.8g/㎗, respectively, and men aged 50 ∼ 64 years showed significant high AL levels compared to other age groups of men. It was suggested that nutrition education program was a good way to improve health status of the elderly.

Suggested Protocol for Efficient Medical Image Information Exchange in Korea: Breast MRI (효율적 의료영상정보교류를 위한 프로토콜 제안: 유방자기공명영상)

  • Park, Ji Hee;Choi, Seon-Hyeong;Kim, Sungjun;Yong, Hwan Seok;Woo, Hyunsik;Jin, Kwang Nam;Jeong, Woo Kyoung;Shin, Na-Young;Choi, Moon Hyung;Jung, Seung Eun
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.5
    • /
    • pp.254-258
    • /
    • 2018
  • Purpose: Establishment of an appropriate protocol for breast magnetic resonance imaging (MRI) in the study of image quality standards to enhance the effectiveness of medical image information exchange, which is part of the construction and activation of clinical information exchange for healthcare informatization. Materials and Methods: The recommended protocols of breast and MRI scans were reviewed and the questionnaire was prepared by a responsible researcher. Then, a panel of 9 breast dedicated radiologists was set up in Korea. The expert panel conducted a total of three Delphi agreements to draw up a consensus on the breast MRI protocol. Results: The agreed breast MRI recommendation protocol is a 1.5 Tesla or higher device that acquires images with prone position using a breast dedicated coil and includes T2-weighted and pre-contrast T1-weighted images. Contrast enhancement images are acquired at least two times, and include 60-120 seconds between images and after 4 minutes. The contrast enhancement T1-weighted image should be less than 3 mm in thickness, less than 120 seconds in temporal resolution, and less than $1.5mm^2$ in-plane pixel resolution. Conclusion: The Delphi agreement of the domestic breast imaging specialist group has established the recommendation protocol of the effective breast MRI.

A Study on the Difficulties Faced by High School Science Teachers in Operating LMO Laboratories (고등학교 LMO 실험실 운영에서 과학교사가 갖는 어려움에 관한 연구)

  • Seongjae Lee;Jiwon Yeo;Sang-Hak Jeon
    • Journal of The Korean Association For Science Education
    • /
    • v.43 no.1
    • /
    • pp.1-15
    • /
    • 2023
  • As the social and economic value of living modified organisms (LMOs) increase, so do the potential risks they pose to humans and the environment. Therefore, all laboratories using LMOs must establish an LMO laboratory in accordance with the standards required by regulations. Recently, in high school, LMO-related experimental programs have been developed for their educational effects. Also, in this case, it is necessary to comply with the regulation for LMO laboratories. However, high schools are still unfamiliar with the LMO laboratory, and it is difficult for teachers to manage an LMO laboratory because its implementation applies the same standards to general research institutes. In this study, we used causal chain analysis to discover the difficulties each teacher faced while setting up an LMO laboratory by examining three cases. The difficulties experienced by teachers are as follows: the first problem is "reluctance to set up an LMO laboratory," because of "administrative tasks for laboratory registration" and "difficulty in persuading colleagues." The second problem is a difficulty for teachers to operate LMO laboratory in blind spots, due to "inflexible installation and closure," "medical waste disposal," and "LMO education that does not fit the school context." Through this study, although the difficulty of running an LMO laboratory is caused by a lack of necessity and insufficient consideration of the school context, the more fundamental cause was a lack of collaborative planning between the educational field and the operating institutions. The teachers who participate in this research suggest that "using shared LAB" and "preparing opportunities for knowledge sharing" can be considered as strategies for operating the school's LMO laboratory. We feel that this study will provide a useful reference for teachers or schools planning to build an LMO laboratory.

Development of relative radiometric calibration system for in-situ measurement spectroradiometers (현장관측용 분광 광도계의 상대 검교정 시스템 개발)

  • Oh, Eunsong;Ahn, Ki-Beom;Kang, Hyukmo;Cho, Seong-Ick;Park, Young-Je
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.4
    • /
    • pp.455-464
    • /
    • 2014
  • After launching the Geostationary Ocean Color Imager (GOCI) on June 2010, field campaigns were performed routinely around Korean peninsula to collect in-situ data for calibration and validation. Key measurements in the campaigns are radiometric ones with field radiometers such as Analytical Spectral Devices FieldSpec3 or TriOS RAMSES. The field radiometers must be regularly calibrated. We, in the paper, introduce the optical laboratory built in KOSC and the relative calibration method for in-situ measurement spectroradiometer. The laboratory is equipped with a 20-inch integrating sphere (USS-2000S, LabSphere) in 98% uniformity, a reference spectrometer (MCPD9800, Photal) covering wavelengths from 360 nm to 1100 nm with 1.6 nm spectral resolution, and an optical table ($3600{\times}1500{\times}800mm^3$) having a flatness of ${\pm}0.1mm$. Under constant temperature and humidity maintainance in the room, the reference spectrometer and the in-situ measurement instrument are checked with the same light source in the same distance. From the test of FieldSpec3, we figured out a slight difference among in-situ instruments in blue band range, and also confirmed the sensor spectral performance was changed about 4.41% during 1 year. These results show that the regular calibrations are needed to maintain the field measurement accuracy and thus GOCI data reliability.