• Title/Summary/Keyword: reference standards

Search Result 764, Processing Time 0.027 seconds

Determination of trace elements in food reference materials by instrumental neutron activation analysis

  • Cho, K.H.;Zeisler, R.;Park, K.W.
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.520-528
    • /
    • 2005
  • Two biological Certified Reference Materials (CRMs), KRISS 108-04-001 (oyster tissue) and 108-05-001 (water dropwort stem), were prepared by Korea Research Institute of Standards and Science (KRISS)during FY '01. The certified values of these materials had been determined by Isotope Dilution Mass Spectrometry (IDMS) for six elements (Cd, Cr, Cu, Fe, Pb and Zn). Additional analytical works are now progressing to certify the concentrations of a number of the environmental and nutrimental elements in these CRMs. The certified values in a CRM are usually determined by using a single primary method with confirmation by other method(s) or using two independent critically-evaluated methods. Instrumental Neutron Activation Analysis (INAA) plays an important role in the determination of certified values as it can eliminate the possibility of common error sources resulting from sample dissolution. In this study INAA procedure was used in determination of 23 elements in these two biological CRMs to acquire the concentration information and the results were compared with KRISS certified values.

A Low-noise Double Relaxation Oscillation SQUID Magnetometer for Measuring Magnetoencephalogram

  • 강찬석;이용호;권혁찬;김진목;윤병운
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.151-158
    • /
    • 2002
  • We developed a useful SQUID magnetometer for biomagnetic applications, magnetoencepha-logram(MEG) and magnetocardiogram(MCG), etc. The SQUIDs are based on Double Relaxation Oscillation SQUID(DROS). DROS consists of two SQUIDs(signal SQUID and reference SQUID) in series, and a relaxation circuit of an inductor and a resistor. Specially we used single reference junction instead of the reference SQUID. The SQUIDs are based on hysteretic $Nb/AlO_{x}$Nb junctions, fabricated by using a simple four level process. Because DROS magnetometer has large flux-to-voltage transfer coefficient, we can use simple flux-locked loop electronics fur SQUID operation. When the DROS magnetometer was operated inside a magnetically shielded room, its average magnetic field noise was about 3 (equation omitted) at 100 Hz. This noise level is low enough to measure biomagnetic fields. In this paper, we describe noise characteristics of DROS magnetometer, depending on the operation condition . .

  • PDF

Role and Prospective of Reference Standards for Integrity Controls of Large-scale Structure and Facilities (대형 설비/구조물 안전성에 있어서 국가참조표준의 역할과 전망)

  • Nahm, Seung-Hoon;Lee, Yun-Hee;Baek, Un-Bong;Chung, In-Hyun;Lee, Hae-Moo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.84-89
    • /
    • 2007
  • In order to guarantee the safety of the facility systems, one of the essential components is information on mechanical properties of materials used for the construction. However, acquisition or accumulation of the mechanical property data in industrial fields is limited because this operation does not yield profit, excepting few materials production companies. Corresponding to the urgent needs and poor economical features, the MOCIE has founded the National Center for Standard Reference Data in the KRISS and also designated the Data Center of Mechanical Properties for Metallic Materials (DCMP) as a principal operating section. The DCMP plays roles of collection, edition and evaluation of the mechanical data and development of reference standards. In this study, several functions of the DCMP and standardization procedures of mechanical properties data will be introduced the prospective of standard reference researches will be discussed based on active feedbacks from industrial fields.

  • PDF

New Method of Volume Measurement for Reference Weights of a Pressure Balance Using a Gas Pycnometer (기체용적계를 이용한 분동식 압력계용 기준분동의 새로운 부피측정 방법)

  • Lee, Yong Jae;Lee, Woo Gab;Mohammed, Mohammed Abdurahman;Park, Yon-Kyu;Oh, Chae Yoon
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.5
    • /
    • pp.231-237
    • /
    • 2013
  • New method of volume measurement for reference weights of a pressure balance using a gas pycnometer is proposed. The result of volume measurement of proposed method shows the uncertainties of approximately 0.2% at the level of confidence of 95% for reference weights in the ranges of 1 kg, 2 kg, and 5 kg. This measuring system consists of a sample chamber, an expansion chamber, a precision pressure gage, a precison thermometer, a vacuum pump, and helium as a medium gas. The measurement principle of this proposed method is based on Boyle's law. This method will contribute a reliability of the volume measurements of reference weights for a pressure balance to the national measurement standard.

Application of draft nutritional standards for school lunches in the Republic of Korea: a feasibility study from the supplier perspective

  • Youngmin Nam;Jihyun Yoon;Meeyoung Kim
    • Nutrition Research and Practice
    • /
    • v.17 no.1
    • /
    • pp.149-163
    • /
    • 2023
  • BACKGROUND/OBJECTIVES: The purpose of this study was to evaluate the feasibility of application of the draft nutritional standards for school lunches in the Republic of Korea (South Korea) from the supplier perspective. SUBJECTS/METHODS: In November 2018, a pilot operation was conducted at 104 participating schools for 2 weeks each by applying the draft standards A and B. To evaluate the ease and appropriateness of application of the standards, we analyzed the nutritional values and food cost of the school lunches for 2 weeks before and for 4 weeks under the pilot operation. We conducted an online survey of school dietitians or nutrition teachers of the participating schools to evaluate the feasibility of application of the standards in school lunch sites. RESULTS: The proportions of schools of which lunches met the reference values of the school's own nutritional standards were 19.2% for the standards A and 21.2% for the standards B. The food cost of school lunches applying the standards A (KRW 2,880) was significantly lower than that of school lunches applying the standards B (KRW 3,030) or the existing standards (KRW 2,980). As a result of the survey, the mean score for the ease of application was significantly higher for the standards B (2.75) than for the standards A (2.24). The proportions of school dietitians or nutrition teachers reporting no problem in meeting an existing food cost standard were 72.5% for the standards A and 61.8% for the standards B, respectively. The overall appropriateness of application was higher for the standards B, because almost two-thirds (58.8%) of the respondents answered that the standards B were more appropriate than the standards A. CONCLUSION: The standards B were more feasible to apply as nutritional standards for school lunches than the standards A from the supplier perspective.

Preparation and Certification of Rice Flour Reference Materials for Trace Elements Analysis (미량원소분석을 위한 쌀분말 기준물질의 제조 및 검정)

  • Cho, Kyung-Haeng;Park, Chang-Joon;Woo, Jin-Choon;Suh, Jung-Ki;Han, Myung-Sub;Lee, Jong-Hae
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.271-280
    • /
    • 1998
  • Rice flour reference materials were prepared from the unpolished rice grown in Korea and certified for elemental composition. The reference materials consist of two samples containing normal and high level. The reference material at elevated level was prepared by spiking to the normal rice flour six toxic elements of As, Cd, Cu, Cr, Hg, Pb with $1.0{\mu}g/g$ on a dry weight basis. Homogeneity of the prepared materials was evaluated through the determination of Ca, Cu, Fe, Mn, Zn by instrumental neutron activation analysis (INAA) and atomic absorption spectrometry (AAS). Small variance of elemental composition among interbottled samples assured homogeneity of the prepared materials. The materials were decomposed by high pressure digestion and microwave digestion method. INAA, AAS, inductively coupled plasma-atomic absorption spectrometry (ICP-AES), ICP-mass spectrometry (MS) and vapour generation techniques were employed to analyze the reference materials. From this independent analytical results, the certified or reference values are determined for As, Ca, Cd, Cr, Cu, Fe, Hg, K, Mg, Mn, Mo, Na, P, Pb, Se, Zn.

  • PDF

EFFICIENT VIDEO TRANSCODING IN THE GOP STRUCTURE CONVERSION (GOP 구조 변환에 있어서의 효율적인 트랜스코딩 기법)

  • Lee, Kang-Jun;Kim, Jeong-Jun;Jeong, Je-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.292-294
    • /
    • 2007
  • Recently, for satisfying many application demands such as coding delay, computing power, transporting channel characteristic, etc, many profiles are supported in video coding standards. Therefore, in transcoding between same standards or between other standards, the functional difference of profiles supported by application occur many problems. In this paper, transcoding MPEG-2 main profile to H.264/AVC baseline profile which has restriction in the number of reference frame is focused. In this case, the bidirectional prediction supported in MPEG-2 main profile is not supported in H.264/AVC baseline profile. Also, in the restriction of reference frame, motion vectors in the MPEG-2 decoder as predictor should be adjusted. In this paper, the proposed algorithm is based on the characteristic of which motion. vector is uniform according to the distance from reference frame. The adaptive search techniques through the determination of the uniformity extremely reduce the computational complexity.

  • PDF

An international Comparison Measurement of Silicon Wafer Sheet Resistance using the Four-point Probe Method

  • Kang, Jeon-Hong;Ying, Gao;Cheng, Yuh-Chuan;Kim, Chang-Soo;Lee, Sang-Hwa;Yu, Kwang-Min
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.325-330
    • /
    • 2015
  • With approval from the Asia Pacific Metrology Program Working Group on Materials Metrology (APMP WGMM), an international comparison for sheet resistance standards for silicon wafers was firstly conducted among Korea Research Institute of Standards and Science (KRISS) in Korea, CMS/ITRI in Taiwan, and NIM in China, which are national metrology institutes (NMIs), from August 2011 to January 2012. The sheet resistance values of the standards are $10{\Omega}$, $100{\Omega}$, and $1000{\Omega}$; the measurement was conducted in sequence at KRISS, CMS/ITRI, NIM, and KRISS again using the four-point probe method with single and dual configuration techniques. The reference value for the measurement results of the three NMIs was obtained through averaging the values of the three results for each sheet resistance range. The differences between the reference value and the measured values is within 0.22% for $10{\Omega}$, 0.17% for $100{\Omega}$, and 0.12% for $1000{\Omega}$. Therefore, the international consistency for conducting sheet resistance measurements is confirmed within 0.22% through the APMP WGMM approved comparison.

Development of Isotope Dilution LC-MS/MS Method for Accurate Determination of Arsenobetaine in Oyster Certified Reference Material

  • Lee, Woo Young;Yim, Yong-Hyeon;Hwang, Euijin;Lim, Youngran;Kim, Tae Kyu;Lee, Kyoung-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.821-827
    • /
    • 2014
  • An isotope dilution liquid chromatography tandem mass spectrometry (ID LC-MS/MS) method has been developed and applied to the determination of arsenobetaine (AsB, ${(CH_3)_3}^+AsCH_2COO^-$) from oyster candidate certified reference material (CRM). The exact matching isotope dilution approach was adopted for accurate determination of AsB using $^{13}C_2$-labeled AsB as an internal standard. Efficiencies of different AsB extraction methods were evaluated using a codfish reference material and a simple sonication method was selected as the method of choice for the certification of the oyster candidate CRM. The hydrophilic interaction liquid chromatography (HILIC) combined with electrospray ionization tandem mass spectrometry (ESI/MS/MS) in selected reaction monitoring (SRM) mode was optimized for adequate chromatographic retention and robust quantification of AsB from codfish and oyster samples. By analyzing 12 subsamples taken from each 12 bottles systematically selected from the whole oyster CRM batch, the certified value of AsB was determined as $6.60mg{\cdot}kg^{-1}{\pm}0.31mg{\cdot}kg^{-1}$ and it showed excellent between-bottle homogeneity of less than 0.42%, which is represented by relative standard deviation of 12 bottles from the CRM batch. The major source of uncertainty was the certified value of the AsB standard solution.

Effect of the Sensor Location on Magnetocardiography (심자도 센서의 위치 효과에 대한 연구)

  • Lim, Hyun-Kyoon;Kim, Ki-Woong;Kwon, Hyuk-Chan;Lee, Yong-Ho
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Magnetocardiography (MCG) is a non-contact, non-invasive, and harmless diagnostic tool to detect the abnormal electrical conductivities of the heart caused by the various coronary artery disease or cardiac muscular disease. The purpose of this study is to identify whether MCG signals and MCG parameter values vary depending on the location of sensor assembly. It will be an important reference for the standard measurement. Four healthy male subjects (33.3$\pm$6.3 years) participated in this study. Basal recording was made at 20 mm apart from the chest surface. All subjects were requested to take a regular breathe while MCG was taken. The gap between the chest surface and the bottom of the sensor assembly was 20, 40, 60, and 80 mm. Recording was made using 64 channel MCG system (Axial type, first order gradiometer) developed by Korea Research Institute of Standards and Science (KRISS). After resting for two minutes in a supine position on the bed in magnetically shielded room, MCG were recorded for 30 s. As the sensor location is getting away from the chest surface signal, the amplitude of R and T wave peak decreases to 70% (at 40 mm gap), 50% (at 60 mm), and 37% (at 80 mm) of the reference strength measured (y = $1.3903e^{-0.0169x}$, $R^2$ = 0.99; where y=amplitude remained after reduction, x=distance between chest surface and sensor location). The regression equations may be used as a good reference to calculate how much strength will be decreased by the distance. In MCG parameters, most values of parameters were decreased as the gap was increased. As an example, the current moment at T-wave peak reduced to 52% (at 40 mm gap), 33% (at 60 mm), and 19% (at 80 mm). However, the difference caused by the gap could be reduced by considering the distance when the MCG parameters were calculated. The study results can be used as a useful reference to design the baseline and the sensor location.

  • PDF