장기간 온도변화에 따른 전차선로 전선류의 노후도 분석 (Aging Analysis of Catenary Wires in Accordance with Temperature Changes for a Long Period of Time)

  • 조남희;오완식;김재문
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1590-1596
    • /
    • 2016
  • In this paper, catenary wires were analyzed aging through the experiment about a new product and a test sample in accordance with temperature changes from long-term use. In case of the contact wire, the maximum load was reduced within 7% and the tensile strength showed a reduced within 6.7% compared with a new reference standard $110mm^2$. 19 Strands of messenger wire have a little more than a standard value, but result data on tensile test were less than the reference value about stranded wire. Also parts among 49 strands of dropper was found to be smaller than the reference value and it appeared greatly increasing intensity as toward the center of the strand.

Implementation Privacy Reference Architecture for Forensic Readiness

  • Shin, Yong-Nyuo
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제12권1호
    • /
    • pp.53-59
    • /
    • 2012
  • As the Privacy Act is in force in Korea, the subject of protection responsibility is increased, and continuous efforts are made to protect privacy in overseas countries, as can be seen by standard drafts related to privacy protection. However, the reality is that a formal privacy manual or guidelines are insufficient to help cope with the rapid changes and privacy leak caused by TGIF(Twitter-Google-iPhone-Facebook) these days, and practical effects cannot be expected, even though measures are taken. This paper propose a standard format for satisfying the ISO/IEC 29101 "Privacy Reference Architecture" and shows an implementation example for equipping with forensic readiness capturing indications of the incident rapidly and coming up with an effective counter measure when privacy information is disclosed.

손실감도를 이용한 계통손실 최적화에 대하여 (On The Optimal Generation Using The Loss Sensitivities Derived by Angle Reference Transposition)

  • 양성덕;이상중
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.59-63
    • /
    • 2005
  • 전력계통을 효율적으로 운용하려면 관련량을 정확하고 신속히 계산하는 좋은 알고리즘이 필요하다. 최근 IEEE Transaction on Power System에 위상각 이동을 이용한 손실 최적화 알고리즘이 발표되었다. 동일한 손실최적화 문제를 본 논문에서는 Standard method of Lagrange Multiplier 기법을 적용하여 해석하였으며, 그 결과 저자들은 두 가지 방법이 수학적으로 동일함을 증명하였다.

Standardization of Fracture Toughness Testing of Ceramics in the United States

  • Quinn, G.D.;Jenkins, M.J.;Salem, J.;Bar-On, I.
    • The Korean Journal of Ceramics
    • /
    • 제4권4호
    • /
    • pp.311-322
    • /
    • 1998
  • American Society for Testing and Materials (ASTM) standard test method PS 070-97 has been created for measuring fracture toughness of advanced ceramics. PS 070-97 includes three test methods which use beams in bending: chevron notch (CNB), single-edged precracked beam (SEPB), and surface crack in flexure (SCF). Supporting data has been collected through several Versailles Advanced Materials and Standards round robins. This paper discusses the evolution of the standard including the rationale for the choice of the three methods and the specifications in the standard. Progress on Standard Reference material 2100 which will have certified values of fracture toughness is presented.

  • PDF

Historical Control Data from 4-week Repeated Toxicity Studies in Crj:CD (SD) Rats

  • Lee, Jung-Min;Lee, Min-Ah;Do, Hyeon-Nam;Bae, Re-Ji-Na;Lee, Mi-Ju;Kim, Myoung-Jun;Jang, Ho-Song;Park, Sun-Hee;Lee, Hye-Yeong;Kang, Jin-Seok;Kang, Jong-Koo
    • 대한의생명과학회지
    • /
    • 제18권3호
    • /
    • pp.268-275
    • /
    • 2012
  • Reference ranges of standard experimental parameters are useful for comparisons in toxicology. The aim of this study was to collect data from 4-week repeated toxicity studies in Crl:CD (SD) rats, a strain widely used for toxicity and efficacy research, for establishing domestic reference values. Data on body weight, food consumption; urinalysis, hematological, and blood biochemical parameters; and organ weights were collected from 16 toxicity studies in 220 Crl:CD (SD) rats (110 males and 110 females). The studies had been performed at a single testing facility over the last 3 years and involved animals sourced from a single breeder. The findings were collated as means, standard deviations, percentages, and ranges. Urine volume, uterus weight, eosinophil, and basophil counts, and triglyceride, total bilirubin, and gammaglutamyl transpeptidase levels showed standard deviations of 30% or more. These historical control data would help to interpret the effects of test substances in routine toxicity and efficacy studies.

Determination of Protein Content in Pea by Near Infrared Spectroscopy

  • Lee, Jin-Hwan;Choung, Myoung-Gun
    • Food Science and Biotechnology
    • /
    • 제18권1호
    • /
    • pp.60-65
    • /
    • 2009
  • Near infrared reflectance spectroscopy (NIRS) was used as a rapid and non-destructive method to determine the protein content in intact and ground seeds of pea (Pisum sativum L.) germplasms grown in Korea. A total of 115 samples were scanned in the reflectance mode of a scanning monochromator at intact seed and flour condition, and the reference values for the protein content was measured by auto-Kjeldahl system. In the developed ground and intact NIRS equations for analysis of protein, the most accurate equation were obtained at 2, 8, 6, 1 math treatment conditions with standard normal variate and detrend scatter correction method and entire spectrum (400-2,500 nm) by using modified partial least squares regression (n=78). External validation (n=34) of these NIRS equations showed significant correlation between reference values and NIRS estimated values based on the standard error of prediction (SEP), $R^2$, and the ratio of standard deviation of reference data to SEP. Therefore, these ground and intact NIRS equations can be applicable and reliable for determination of protein content in pea seeds, and non-destructive NIRS method could be used as a mass analysis technique for selection of high protein pea in breeding program and for quality control in food industry.

Use of preoperative cone-beam computed tomography to aid in establishment of endodontic working length: A systematic review and meta-analysis

  • Paterson, Andrew;Franco, Vittorio;Patel, Shanon;Foschi, Federico
    • Imaging Science in Dentistry
    • /
    • 제50권3호
    • /
    • pp.183-192
    • /
    • 2020
  • Purpose: This study was performed to assess the accuracy of preoperative cone-beam computed tomography (CBCT), when justified for other reasons, in locating the apical foramen and establishing the working length. Materials and Methods: Six electronic databases were searched for studies on this subject. All studies, of any type, were included if they compared measurements of working length with preoperative CBCT to measurements using an electronic apex locator (EAL) or histological reference standard. Due to the high levels of heterogeneity, an inverse-variance random-effects model was chosen, and weighted mean differences were obtained with 95% confidence intervals and P values. Results: Nine studies were included. Compared to a histological reference standard, CBCT indicated that the apical foramen was on average 0.40 mm coronal of its histological position, with a mean absolute difference of 0.48 mm. Comparisons were also performed to an EAL reference standard, but the conclusions could not be considered robust due to high levels of heterogeneity in the results. Conclusion: A low level of evidence is produced suggesting that preoperative CBCT shows the apical foramen to be on average 0.40 mm coronal to its histological position, with a mean absolute difference of 0.48 mm.

개선된 CTAT 보상을 가지는 저전압 CMOS Bandgap Voltage Reference (Modified Low-Votlage CMOS Bandgap Voltage Reference with CTAT Compensation)

  • 김재붕;조성익
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.753-756
    • /
    • 2012
  • In this paper, a modified low-votlage CMOS bandgap voltage reference with CTAT compensation is presented. The proposed structure doesn't use PTAT current. The proposed structure is more simple than the existing structure and doesn't use the eighteen BJT. The modified low-votlage CMOS bandgap voltage reference with CTAT compensation has been successfully verified in a standard 0.18um CMOS process. The simulation results have confirmed that, with the minimum supply voltage of 1.25V, the output reference voltage at 549mV has a temperature coefficient of 12$ppm/^{\circ}C$ from $0^{\circ}C$ to $100^{\circ}C$.

국내 표준연료(휘발유) 도입 필요성 검토 연구 (A feasibility study on Introducing the Reference Fuel(Gasoline) for Testing Vehicles in South Korea)

  • 강형규;성상래;송호영;황인하;하종한;나병기
    • 한국응용과학기술학회지
    • /
    • 제33권4호
    • /
    • pp.824-835
    • /
    • 2016
  • 2015년 기준 자동차 등록대수는 약 2,100만대를 넘어 1가구당 1.07대를 보유하고 있는 실정이나[1], 국내 자동차용 표준연료에 대한 기준은 부재한 상황이다. 자동차용 표준연료(reference fuel)는 차량의 연비와 배출가스를 인증하거나 새로운 자동차를 개발할 때 차량의 성능 등을 평가하기 위해 사용하는 연료를 의미한다. 현재 국내에는 차량의 배출가스, 성능, 연비시험 등을 위해 유통연료를 사용하고 있으며, 유통연료는 석유 및 석유대체연료사업법과 대기환경보전법 상의 품질기준을 만족하지만 각 제조사의 원료와 공정 등에 따라 연료의 물성차이가 있어 차량 시험 시 편차가 발생할 수 있다. 본 연구에서는 국내 유통되는 휘발유 품질모니터링 분석결과를 바탕으로 표준연료 기준(안)을 설정하고, GDI와 MPI 연료 분사 방식의 차량에 적용하여 비교 평가한 결과, 실제 유통연료를 사용했을 때 최대 3.8%까지 발생하는 연비차이가 1.1%까지 감소함을 확인할 수 있었다.