DOI QR코드

DOI QR Code

Aging Analysis of Catenary Wires in Accordance with Temperature Changes for a Long Period of Time

장기간 온도변화에 따른 전차선로 전선류의 노후도 분석

  • Cho, Nam-Hee (Dept. of Railroad Electrical System Engineering, Woosong University) ;
  • Oh, Wan-Shik (Dept. of Railroad Electrical System Engineering, Woosong University) ;
  • Kim, Jae-moon (Dept. of Transportation System Engineering, Graduate School of Transportation, Korea National University of Transportation)
  • Received : 2016.08.01
  • Accepted : 2016.08.24
  • Published : 2016.09.01

Abstract

In this paper, catenary wires were analyzed aging through the experiment about a new product and a test sample in accordance with temperature changes from long-term use. In case of the contact wire, the maximum load was reduced within 7% and the tensile strength showed a reduced within 6.7% compared with a new reference standard $110mm^2$. 19 Strands of messenger wire have a little more than a standard value, but result data on tensile test were less than the reference value about stranded wire. Also parts among 49 strands of dropper was found to be smaller than the reference value and it appeared greatly increasing intensity as toward the center of the strand.

Keywords

References

  1. Yang-Su Kim, Hae-Chul Yu, "Electric Railway Engineering" dongil publisher 2012
  2. Korea Rail Network Authority, KR-Code, 2016
  3. Korea, General Electrical Railroad, K722-4C101-1, K722-4-C104-1, K722-4-C-105-1
  4. Korea Railway Standards KRS PW 0005-06(R) Handdrawn Copper Round Trolley Wire, 2006
  5. Korea Railway Standards KRS PW 0007-15(R) Cadmium Copper Stranded Wire
  6. Gi-chun Lee, Tae-hoon Lee, Jong-woo Lee, "Mechanical Loads of Dropper for High Speed Electric Railway", Journal of the Korean Society for Railway, Vol. 14, No. 3, pp. 222-227, 2011 https://doi.org/10.7782/JKSR.2011.14.3.222