DOI QR코드

DOI QR Code

Use of preoperative cone-beam computed tomography to aid in establishment of endodontic working length: A systematic review and meta-analysis

  • Paterson, Andrew (Department of Endodontics, The Faculty of Dentistry, Oral and Craniofacial Sciences at Kings' College London) ;
  • Franco, Vittorio (UK Dental Specialists, UKDS) ;
  • Patel, Shanon (Department of Endodontics, The Faculty of Dentistry, Oral and Craniofacial Sciences at Kings' College London) ;
  • Foschi, Federico (Department of Endodontics, The Faculty of Dentistry, Oral and Craniofacial Sciences at Kings' College London)
  • Received : 2019.12.15
  • Accepted : 2020.04.26
  • Published : 2020.09.30

Abstract

Purpose: This study was performed to assess the accuracy of preoperative cone-beam computed tomography (CBCT), when justified for other reasons, in locating the apical foramen and establishing the working length. Materials and Methods: Six electronic databases were searched for studies on this subject. All studies, of any type, were included if they compared measurements of working length with preoperative CBCT to measurements using an electronic apex locator (EAL) or histological reference standard. Due to the high levels of heterogeneity, an inverse-variance random-effects model was chosen, and weighted mean differences were obtained with 95% confidence intervals and P values. Results: Nine studies were included. Compared to a histological reference standard, CBCT indicated that the apical foramen was on average 0.40 mm coronal of its histological position, with a mean absolute difference of 0.48 mm. Comparisons were also performed to an EAL reference standard, but the conclusions could not be considered robust due to high levels of heterogeneity in the results. Conclusion: A low level of evidence is produced suggesting that preoperative CBCT shows the apical foramen to be on average 0.40 mm coronal to its histological position, with a mean absolute difference of 0.48 mm.

Keywords

References

  1. Vertucci FJ. Root canal morphology and its relationship to endodontic procedures. Endod Topics 2005; 10: 3-29. https://doi.org/10.1111/j.1601-1546.2005.00129.x
  2. Ricucci D, Langeland K. Apical limit of root canal instrumentation and obturation, part 2. A histological study. Int Endod J 1998; 31: 394-409. https://doi.org/10.1046/j.1365-2591.1998.00183.x
  3. Ng YL, Mann V, Gulabivala K. A prospective study of the factors affecting outcomes of non-surgical root canal treatment: part 2: tooth survival. Int Endod J 2011; 44: 610-25. https://doi.org/10.1111/j.1365-2591.2011.01873.x
  4. Hassanien EE, Hashem A, Chalfin H. Histomorphometric study of the root apex of mandibular premolar teeth: an attempt to correlate working length measured with electronic and radiograph methods to various anatomic positions in the apical portion of the canal. J Endod 2008; 34: 408-12. https://doi.org/10.1016/j.joen.2007.12.013
  5. Citterio F, Pellegatta A, Citterio CL, Maddalone M. Analysis of the apical constriction using micro-computed tomography and anatomical sections. G Ital Endod 2014; 28: 41-5. https://doi.org/10.1016/j.gien.2014.05.001
  6. Schell S, Judenhofer MS, Mannheim JG, Hulber-J M, Lost C, Pichler BJ, et al. Validity of longitudinal sections for determining the apical constriction. Int Endod J 2017; 50: 706-12. https://doi.org/10.1111/iej.12670
  7. Connert T, Judenhofer MS, Hulber-J M, Schell S, Mannheim JG, Pichler BJ, et al. Evaluation of the accuracy of nine electronic apex locators by using Micro-CT. Int Endod J 2017; 51: 223-32. https://doi.org/10.1111/iej.12814
  8. Chen E, Abbott PV. Evaluation of accuracy, reliability, and repeatability of five dental pulp tests. J Endod 2011; 37: 1619-23. https://doi.org/10.1016/j.joen.2011.07.004
  9. Janner SF, Jeger FB, Lussi A, Bornstein MM. Precision of endodontic working length measurements: a pilot investigation comparing cone-beam computed tomography scanning with standard measurement techniques. J Endod 2011; 37: 1046-51. https://doi.org/10.1016/j.joen.2011.05.005
  10. Ustun Y, Aslan T, Sekerci AE, Sagsen B. Evaluation of the reliability of cone-beam computed tomography scanning and electronic apex locator measurements in working length determination of teeth with large periapical lesions. J Endod 2016; 42: 1334-7. https://doi.org/10.1016/j.joen.2016.06.010
  11. Jeger FB, Janner SF, Bornstein MM, Lussi A. Endodontic working length measurement with preexisting cone-beam computed tomography scanning: a prospective, controlled clinical study. J Endod 2012; 38: 884-8. https://doi.org/10.1016/j.joen.2012.03.024
  12. Patel S, Dawood A, Whaites E, Pitt Ford T. New dimensions in endodontic imaging: part 1. Conventional and alternative radiographic systems. Int Endod J 2009; 42: 447-62. https://doi.org/10.1111/j.1365-2591.2008.01530.x
  13. Ludlow JB, Timothy R, Walker C, Hunter R, Benavides E, Samuelson DB, et al. Effective dose of dental CBCT - a meta analysis of published data and additional data for nine CBCT units. Dentomaxillofac Radiol 2015; 44: 20140197. https://doi.org/10.1259/dmfr.20140197
  14. European Society of Endodontology. Quality guidelines for endodontic treatment: consensus report of the European Society of Endodontology. Int Endod J 2006; 39: 921-30. https://doi.org/10.1111/j.1365-2591.2006.01180.x
  15. European Commission. Radiation Protection 136. European guidelines on radiation protection in dental radiology. Luxembourg: Office for Official Publications of the European Commission; 2004.
  16. Patel S, Brown J, Semper M, Abella F, Mannocci F. European Society of Endodontology position statement: use of cone beam computed tomography in Endodontics: European Society of Endodontology (ESE) developed by. Int Endod J 2019; 52: 1675-8. https://doi.org/10.1111/iej.13187
  17. Higgins JP, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, et al. Cochrane handbook for systematic reviews of interventions. Hoboken: Wiley; 2019.
  18. Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gotzsche PC, Ioannidis JP, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. PLoS Med 2009; 6: e1000100. https://doi.org/10.1371/journal.pmed.1000100
  19. Higgins JP, Green S. Cochrane handbook for systematic reviews of interventions. Hoboken: Wiley-Blackwell; 2008.
  20. Rooney AA, Boyles AL, Wolfe MS, Bucher JR, Thayer KA. Systematic review and evidence integration for literature-based environmental health science assessments. Environ Health Perspect 2014; 122: 711-8. https://doi.org/10.1289/ehp.1307972
  21. Lucena C, Lopez JM, Martin JA, Robles V, Gonzalez-Rodriguez MP. Accuracy of working length measurement: electronic apex locator versus cone-beam computed tomography. Int Endod J 2013; 47: 246-56. https://doi.org/10.1111/iej.12140
  22. Mrasori S, Budina R, Dragidella F. In vitro evaluation of three electronic apex locators using conventional methods and cone beam computed tomography. Minerva Stomatol 2014; 63: 259-66.
  23. Elshinawy MI. In-vitro comparison of four different working length determination techniques. Tanta Dent J 2017; 14: 12-6. https://doi.org/10.4103/tdj.tdj_55_16
  24. Yildirim C, Aktan AM, Karataslioglu E, Aksoy F, Isman O, Culha E. Performance of the working length determination using cone beam computed tomography, radiography and electronic apex locator, in comparisons to actual length. Iran J Radiol 2017; 14: e13468.
  25. Yilmaz F, Kamburoglu K, Senel B. Endodontic working length measurement using cone-beam computed tomographic images obtained at different voxel sizes and field of views, periapical radiography, and apex locator: a comparative ex vivo study. J Endod 2017; 43: 152-6. https://doi.org/10.1016/j.joen.2016.09.019
  26. Aleksandraa đ, Irenaa KR, Milosb C, Ilijab V, Adrianac A, Teodorad U, Markod U, Draganad J. Root canal working length determination using cone beam computed tomography. Serbian Dent J 2019; 66: 57-65.
  27. Sherrard JF, Rossouw PE, Benson BW, Carrillo R, Buschang PH. Accuracy and reliability of tooth and root lengths measured on cone-beam computed tomographs. Am J Orthod Dentofacial Orthop 2010; 137(4 Suppl): S100-8. https://doi.org/10.1016/j.ajodo.2009.03.040
  28. Yang H, Tian C, Li G, Yang L, Han X, Wang Y. A cone-beam computed tomography study of the root canal morphology of mandibular first premolars and the location of root canal orifices and apical foramina in a Chinese subpopulation. J Endod 2013; 39: 435-8. https://doi.org/10.1016/j.joen.2012.11.003
  29. Michetti J, Maret D, Mallet JP, Diemer F. Validation of cone beam computed tomography as a tool to explore root canal anatomy. J Endod 2010; 36: 1187-90. https://doi.org/10.1016/j.joen.2010.03.029
  30. Dhingra A, Dayal C, Singh A, Bhardwaj N. Predetermination of root canal lengths in molar teeth: A comparison between radiovisiography and two-dimensional and three-dimensional measurements using cone-beam computed tomography. Indian J Dent 2015; 6: 195-8. https://doi.org/10.4103/0975-962X.170377
  31. de Morais AL, de Alencar AH, Estrela CR, Decurcio DA, Estrela C. Working length determination using cone-beam computed tomography, periapical radiography and electronic apex locator in teeth with apical periodontitis: a clinical study. Iran Endod J 2016; 11: 164-8.
  32. Dutta K, Desai PD, Das UK, Sarkar S. Comparative evaluation of three methods to measure working length - manual tactile sensation, digital radiograph, and multidetector computed tomography: an in vitro study. J Conserv Dent 2017; 20: 76-80. https://doi.org/10.4103/JCD.JCD_4_16
  33. Amin J, Lines J, Milosevic MP, Park A, Sholapurkar A. Comparison of accuracy and reliability of working length determination using cone beam computed tomography and electronic apex locator: a systematic review. J Contemp Dent Pract 2019; 20: 1118-23. https://doi.org/10.5005/jp-journals-10024-2651
  34. Tchorz JP, Poxleitner PJ, Stampf S, Patzelt SB, Rottke D, Hellwig E, et al. The use of cone beam computed tomography to predetermine root canal lengths in molar teeth: a comparison between two-dimensional and three-dimensional measurements. Clin Oral Investig 2014; 18: 1129-33. https://doi.org/10.1007/s00784-013-1064-6
  35. Connert T, Hulber-J M, Godt A, Lost C, ElAyouti A. Accuracy of endodontic working length determination using cone beam computed tomography. Int Endod J 2014; 47: 698-703. https://doi.org/10.1111/iej.12206
  36. Aktan AM, Yildirim C, Karataslioglu E, Ciftci ME, Aksoy F. Effects of voxel size and resolution on the accuracy of endodontic length measurement using cone beam computed tomography. Ann Anat 2016; 208: 96-102. https://doi.org/10.1016/j.aanat.2016.05.005
  37. Segato AV, Piasecki L, Felipe Iparraguirre Nunovero M, da Silva Neto UX, Westphalen VP, Gambarini G, et al. The accuracy of a new cone-beam computed tomographic software in the preoperative working length determination ex vivo. J Endod 2018; 44: 1024-9. https://doi.org/10.1016/j.joen.2018.02.027
  38. Liang YH, Jiang L, Chen C, Gao X-J, Wesselink PR, Wu MK, et al. The validity of cone-beam computed tomography in measuring root canal length using a gold standard. J Endod 2013; 39: 1607-10. https://doi.org/10.1016/j.joen.2013.08.001
  39. Metska ME, Liem VM, Parsa A, Koolstra JH, Wesselink PR, Ozok AR. Cone-beam computed tomographic scans in comparison with periapical radiographs for root canal length measurement: an in situ study. J Endod 2014; 40: 1206-9. https://doi.org/10.1016/j.joen.2013.12.036
  40. Laux M, Abbott PV, Pajarola G, Nair PN. Apical inflammatory root resorption: a correlative radiographic and histological assessment. Int Endod J 2000; 33: 483-93. https://doi.org/10.1046/j.1365-2591.2000.00338.x
  41. Dunlap CA, Remeikis NA, BeGole EA, Rauschenberger CR. An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals. J Endod 1998; 24: 48-50. https://doi.org/10.1016/S0099-2399(98)80214-8
  42. Martos J, Ferrer-Luque CM, Gonzalez-Rodriguez MP, Castro LA. Topographical evaluation of the major apical foramen in permanent human teeth. Int Endod J 2009; 42: 329-34. https://doi.org/10.1111/j.1365-2591.2008.01513.x
  43. Davis D, Marshall G, Baumgartner R. Effect of early coronal flaring on working length change in curved canals using rotary nickel-titanium versus stainless steel instruments. J Endod 2002; 28: 438-42. https://doi.org/10.1097/00004770-200206000-00005