• Title/Summary/Keyword: reference standard

Search Result 2,153, Processing Time 0.031 seconds

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).

On the Novel Concept of "Accident" in the 1999 Montreal Convention -GN v. ZU, CJEU, 2019. 12. 19., C-532/18- (1999년 몬트리올 협약상 "사고"의 새로운 개념에 대한 고찰 - GN v. ZU, CJEU, 2019.12.19., C-532/18 -)

  • An, Ju-Yun
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.35 no.2
    • /
    • pp.3-40
    • /
    • 2020
  • The term "accident" in the Warsaw Convention of 1929 and the Montreal Convention of 1999, which govern carrier liability in international air transport, is an important criterion for determining carrier liability. However, because there is no explicit definition of the term in the treaty provisions, the term is largely subjected to the judgment and interpretation of the courts. Although there have been numerous changes in purpose and circumstance in the transition from the Warsaw regime to the conclusion of the Montreal Convention, there was no discussion on the concept of "accident" therefore, even after the adoption of the Montreal Convention, there is no doubt that the term is to be interpreted in the same manner as before. On this point, the United States Supreme Court's Air France v. Saks clarified the concept of "accident" and is still cited as an important precedent. Recently, the CJEU, in GN v. ZU, presented a new concept of "accident" introduced in the Montreal Convention: that "reference must be made to the ordinary meaning" in interpreting "accident" and that the term "covers all situations occurring on aboard an aircraft." Furthermore, the CJEU ruled that the term does not include the applicability of "hazards typically associated with aviation," which was controversial in previous cases. Such an interpretation can be reasonably seen as the court's expansion of the concept of "accident," with a focus on "protecting consumer interests," a core tenet of both the Montreal convention and the European Union Regulations(EC: No 889/2002). The CJEU's independent interpretation of "accident" is a departure from the Warsaw Convention and the Saks case, with their focus on "carrier protection," and instead focuses on the "passenger protection" standard of the Montreal Convention. Consequently, this expands both the court's discretion and the carrier's risk management liability. Such an interpretation by the CJEU can be said to be in line with the purpose of the Montreal Convention in terms of "passenger protection." However, there are problems to be considered in tandem with an expanded interpretation of "accident." First, there may be controversy concerning "balance" in that it focused on "passenger protection" in relation to the "equitable balance of interests" between air carriers and passengers, which is the basic purpose of the agreement. Second, huge losses are expected as many airlines fly to countries within the European Union. Third, there is now a gap in the interpretation of "accident" in Europe and the United States, which raises a question on the "unity of rules," another basic tenet of the Convention. Fourth, this interpretation of "accident" by the CJEU raises questions regarding its scope of application, as it only refers to the "hazards typically associated with aviation" and "situations occurring aboard an aircraft." In this case, the CJEU newly proposed a novel criterion for the interpretation of "accident" under the Montreal Convention. As this presents food for thought on the interpretation of "accident," it is necessary to pay close attention to any changes in court rulings in the future. In addition, it suggests that active measures be taken for passenger safety by recognizing air carriers' unlimited liability and conducting systematic reforms.

The Effects of the Heavy and Chemical Industry Policy of the 1970s on the Capital Efficiency and Export Competitiveness of Korean Manufacturing Industries (1970년대(年代) 중화학공업정책(重化學工業政策)이 자본효율성(資本效率性)과 수출경쟁력(輸出競爭力)에 미친 영향(影響))

  • Yoo, Jung-ho
    • KDI Journal of Economic Policy
    • /
    • v.13 no.1
    • /
    • pp.65-113
    • /
    • 1991
  • Korea's rapid economic growth of the past thirty years was led by extremely fast export growth under extensive government intervention. Until very recently, the political regimes were authoritarian and oppressed human rights and labor movements. Because of these characteristics, many inside and outside Korea are under the impression that the rapid economic growth was made possible by the government's relentless push for export growth through industrial targetjng. Whether or not the government intervention was pivotal in Korean economic growth is an important issue because of its normative implications on the role of government and the degree of economic policy intervention in a market economy. A good example of industrial targeting policy in Korea is the "Heavy and Chemical Industry (HCI)" policy, which began in the early 1970s and lasted for one decade. Under the HCI policy the government intervened in resource allocation through preferential tax, trade, and credit and interest rate policies for "key industries" which included iron and steel, non-ferrous metals, shipbuilding, general machinery, chemicals, and electronics. This paper investigates the effects of. the HCI policy on the efficiency of capital and the export competitiveness of manufacturing industries. For individual three-digit KSIC (Korea Standard Industrial Classification) industries and for two industry groups, one favored by HCI Policy and the other not, this paper: (1) computes capital intensities and discusses the impact of the HCI policy on the changes in the intensities over time, (2) estimates the capital efficiencies and examines them on the basis of optimal condition of resource allocation, and (3) compares the Korean and Taiwanese shares of total imports by the OECD countries as a way of weighing the effects of the policy on the industries' export competitiveness. Taiwan is a good reference, as it did not adopt the kind of industrial targeting policy that Korea did, while the Taiwanese and Korean economies share similar characteristics. In the 1973-78 period, the capital intensity rose rapidly for the "HC Group" the group of industries favored by the policy, while it first declined and later showed an anemic rise for the "Light Group," the remaining manufacturing industries. Capital efficiency was much lower in the HC Group than in the Light Group, at least until the late 1970s. This paper acribes these results to excess investments in the favored industries and concludes that growth could have been faster in the absence of the HCI policy. The Korean Light Group's share in total imports by the OECD was larger than that of its Taiwanese counterpart but has become much smaller since 1978. For the HC Group Korea's market share was smaller than Taiwan's and has declined even more since the mid-1970s. This weakening in the export competitiveness of Korea's industries relative to Taiwan's lasted until the mid-1980s. This paper concludes that the HCI policy had either no positive effect on the competitiveness of the Korean manufacturing industries or negative effects.

  • PDF

The Study on the Use of a Cylindrical Ionization Chamber for the Calibration of a 6 MeV Electron Beam (6 MeV 전자 빔의 교정에 원통형 이온함의 사용에 관한 연구)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Choi, Jin-Ho;Kim, Hyeog-Ju;Lim, Chun-Il;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.317-323
    • /
    • 2009
  • The standard dosimetry systems based on an absorbed dose to water recommend to use a planeparallel chamber for the calibration of such a low-megavoltage electron beam as a nominal energy of 6 MeV. For this energy ranges of an electron beam a cylindrical chamber should not be used for the routinely regular beam calibration, but the feasibility of the temporary use of a cylindrical chamber was studied to give temporary solutions for special situations users meet. The PTW30013 chambers and the electron beam quality of $R_{50}=2.25\;g/cm^2$ were selected for this study. 10 PTW30013 chambers, a cylindrical type of chamber, were calibrated in KFDA, the secondary standards dosimetry laboratories, and given the absorbed dose-to-water calibration factors, respectively. A "temporary" $k_{Q,Q_0}$ for each chamber were calculated using the absorbed dose determined by a cross-calibrated planeparallel chamber, with the result of an average 0.9352 for 10 chambers. This value for PTW30013 chamber was used to determine an absorbed dose to water at the reference depth. The absorbed doses determined by PTW30013 chambers were in an agreement within 2% with that by ROOS chamber. In a certain situation where a cylindrical chamber be used instead of a planeparellel chamber, the value of 0.9352 might be useful to determine an absorbed dose to water in the same beam quality of electron beam as this study.

  • PDF

Determination of Appropriate Sampling Frequency and Time of Multiple Blood Sampling Dual Exponential Method with $^{99m}Tc$-DTPA for Calculating GFR (사구체여과율 계산을 위한 $^{99m}Tc$-DTPA를 이용한 다중 채혈 이중지수법의 적정 채혈 횟수 및 시간의 선정)

  • Kim, Chung-Ho;O, Joo-Hyun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.33-39
    • /
    • 2006
  • Purpose: To determine appropriate sampling frequency and time of multiple blood sampling dual exponential method with $^{99m}Tc$-DTPA for calculating glomerular filtration rate (GFR). Materials & Methods: Thirty four patients were included in this study. Three mCi of $^{99m}Tc$-DTPA was intravenously injected and blood sampling at 9 different times, 5ml each, were done. Using the radioactivity of serum, measured by gamma counter, the GFR was calculated using dual exponential method and corrected with the body surface area. Using spontaneously chosen 2 data points of serum radioactivity, 15 collections of 2-sample GFR were calculated. And 10 collections of 3-sample GFR and 12 collections of 4-sample GFR were also calculated. Using the 9-sample GFR as a reference value, degree of agreement was analyzed with Kendall's $\tau$ correlation coefficients, mean difference and standard deviation. Results: Although some of the 2-sample GFR showed high correlation coefficient, over or underestimation had evolved as the renal function change. The 10-120-240 min 3-sample GFR showed a high correlation coefficient (${\tau}=0.93$), minimal difference ($Mean{\pm}SD=-1.784{\pm}3.972$), and no over or underestimation as the renal function changed. The 4-sample GFR showed no better accuracy than the 3-sample GFR. Conclusions: In the wide spectrum of renal function, the 10-120-240 min 3-sample GFC could be the best choice for estimating the patients' renal function.

Development of Mixed Pesticides Containing Herbicide and Topdressing Fertilizer for Paddy Rice (벼 제초제(除草劑)와 분약비(分蘖肥) 혼합약제(混合藥劑)의 개발(開發))

  • Park, Yang-Ho;Lee, Byung-Moo;Park, Seung-Soon;Lee, In-Yong;Kim, Young-Koo;Park, Young-Sun
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.3
    • /
    • pp.279-287
    • /
    • 1994
  • To develop mixed pesticides of herbicide and topdressing fertilizer for paddy rice, twelve mixtures were formulated with combination of urea coated with different level of acrylic acid wax(AAW) and four herbicides, which were thiobencarb, pretilachlor, mefenacet + bensulfuron-methyl and mefenacet + bensulfuron-methyl + dymron, and effects of the mixtures for weed control, phytotoxicity and rice tillering were investigated in the laboratory and the field experiments. Release rates of active ingredient of herbicides in the distilled water were over 90% during 24 hours same as that of the reference herbicides. The release rates of nitrogen showed different patterns according to coated level of granular urea with acrylic acid wax. Optimum release rate of nitrogen as $NH_4-N$ was obtained by 5.5% AAW coating on urea for thiobencarb or pretilachlor mixture, and by 4.0% AAW coating on urea for mefenacet + bensulfuron-methyl or mefenacet + bensulfuron-methyl + dymron mixture. The pesticide active ingredients of the mixtures were stable, which showed $3.7{\sim}8.0%$ of degradation rate after 90 days of storage under $50^{\circ}C$. Effects on weed control of mixtures were acceptable for both annual and perennial weeds, while ACRI-M9213 mixture showed considerable phytotoxicity at double dose of standard. When treated the mixed pesticides to paddy rice, rice growth status including culm length, ear length, panicle number and polished rice yield exhibited no significant differences compared with the conventional treatment.

  • PDF

Structural Characteristics and Anti-inflammatory Activities of Chemically Sulfated-hyaluronic Acid from Streptococcus dysgalactiae (Streptococcus dysgalactiae로부터 분리된 히알루론산과 황화된 유도체의 구조와 항염증 활성)

  • Hong, Chang-Il;Jung, Eui-Gil;Han, Kook-Il;Kim, Yong Hyun;Lee, Sung Hee;Lee, Hong Sub;Han, Man-Deuk
    • Journal of Life Science
    • /
    • v.26 no.5
    • /
    • pp.545-554
    • /
    • 2016
  • Hyaluronic acid (HA) is an important macromolecule in medical and pharmaceutical fields. HA is a natural and linear polymer composed of repeating disaccharide units of β-1, 3-N-acetyl glucosamine and β-1, 4-glucuronic acid. This work aimed to confirm the structural characteristics and anti-inflammatory activities of HA and its chemically sulfated-HA. HA was produced from a fed-batch fermentation process using Streptococcus dysgalactiae in a 5 l bioreactor. HA was isolated water-soluble form (HA-WS) and water-insoluble form (HA-WI) from culture medium, and was obtained chemically sulfated-derivative (S-HA) that resulted in a 90% yield from HA-WI. The structural features of the sulfated- HA (S-HA) were investigated by FT-IR and 1H-NMR spectroscopy. The FT-IR and NMR patterns revealed the similarity in both the FTIR spectrum as well as NMR spectrum of both reference standard and purified HA from S. dysgalactiae. The anti-inflammatory activities of HA and S-HA were examined on LPS-induced RAW 264.7 cells. S-HA was significantly inhibited production of pro-inflammatory mediators such as nitric oxide (NO) and PGE2 and the gene levels of iNOS and COX-2, which are responsible for the production of NO and PGE2, respectively. Furthermore, S-HA also suppressed the overproduction of pro-inflammatory cytokine TNF-α (<80 pg/ml) and IL-6 (<100 pg/ml) compared to that of HA-WI. The present study clearly demonstrates that HA-S exhibits anti-inflammatory activities in RAW 264.7 macrophage cells.

A Comparison between BSCS's Guide and the Korean Curriculum for Developing Biological Literacy (생물학적 소양의 함양을 위한 BSCS 통합 권고안과 6,7차 교육과정 비교)

  • Koo, Soo-Jeong;Kim, Young-Shin;Kim, Byung-Suk;Lee, Sung-Jo;Chung, Wan-Ho
    • Journal of The Korean Association For Science Education
    • /
    • v.20 no.3
    • /
    • pp.396-410
    • /
    • 2000
  • In this study, the concept presentation form, the content coherence of sub-dimensional concepts and the number of concepts of the 6th and the 7th Korean curriculum were analyzed comparing the guide to developing the secondary biology curricula to develop biological literacy with BSCS. According to the result, the discrimination between concept levels in the frame of contents of the Korean curricula is insufficient, because each of concepts presented in the knowledge domain as upper level and sub-dimensional concept elements as lower level are simply arrayed. Considering too much concepts of ecosystem, genetics, reproduction and metabolism, there should be an effort to reform the biological curriculum to include concepts evenly, not in the biased state, to reflect all the 6 unifying principles by BSCS for developing students' biological literacy. Finally there should be an effort to reflect the characteristics of each subjects concretely among Science 10, Biology I and Biology IT in the 7th curriculum considering the result that essential concepts to develop biological literacy are presented more in some principles of Biology II than Biology I. Thinking the results of the present study, concrete discussions should be made to set up the standard reference about biological literacy and to present essential concepts for teaching and learning to develop it in the process of biology textbook development for meeting the 7th Korean curriculum and in the development of 8th Korean curriculum in advance.

  • PDF

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

Development of nutrition quotient for Korean preschoolers (NQ-P): Item selection and validation of factor structure (취학전아동 대상 영양지수 개발 : 평가항목 선정과 구성 타당도 검증)

  • Lee, Jung-Sug;Kang, Myung-Hee;Kwak, Tong-Kyung;Chung, Hae Rang;Kwon, Sehyug;Kim, Hye-Young;Hwang, Ji-Yun;Choi, Young-Sun
    • Journal of Nutrition and Health
    • /
    • v.49 no.5
    • /
    • pp.378-394
    • /
    • 2016
  • Purpose: Screening of preschool-age children for nutrition programs to improve dietary intake and behaviors requires cost-effective and easily administered validated assessment tools. The purpose of this study was to develop a parent/caregiver-administered instrument for measuring diet quality and behaviors of preschoolers as a nutrition quotient for preschoolers (NQ-P). Methods: Development of NQ-P was carried out in three steps: item generation, item reduction, and validation. The 24-h dietary record was selected as the gold standard reference tool. The 38 items of the NQ-P checklist were derived from a systematic literature review, expert in-depth interviews, statistical analysis of the fifth Korean National Health and Nutrition Examination Survey data, and national nutrition policies and recommendations. Self-administered questionnaires were delivered to parents who recorded 24-h dietary intakes of 100 responders aged 3~5 yr. Pearson's correlation was used to measure the level of agreement between questionnaires. Item reduction was performed, and 20 items were selected based on survey results, expert reviews, and priorities of national nutrition policy and recommendations. The 412 nationwide subjects sampled through daycare centers completed the 20-item checklist questionnaire. The construct validity of the NQ-P was assessed using confirmatory factor analysis, LISREL. Results: After analyses of exploratory factors, NQ-P items identified three dimensions of diet (balance, moderation, and environment). The three-factor structure accounted for 49.28% of the total variance. Standardized path coefficients were used as weights of the items. The NQ-P and three-factor scores of the subjects were calculated by the obtained weights of the questionnaire items. Conclusion: A food behavior checklist for preschoolers' NQ would be a useful and suitable instrument for evaluating nutrition adequacy and dietary quality of Korean preschoolers.