• Title/Summary/Keyword: reference standard

Search Result 2,153, Processing Time 0.03 seconds

Monte Carlo Simulation of a Varian 21EX Clinac 6 MV Photon Beam Characteristics Using GATE6 (GATE6를 이용한 Varian 21EX Clinac 선형가속기의 6 MV X-선 특성모사)

  • An, Jung-Su;Lee, Chang-Lae;Baek, Cheol-Ha
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.571-575
    • /
    • 2016
  • Monte Carlo simulations are widely used as the most accurate technique for dose calculation in radiation therapy. In this paper, the GATE6(Geant4 Application for Tomographic Emission ver.6) code was employed to calculate the dosimetric performance of the photon beams from a linear accelerator(LINAC). The treatment head of a Varian 21EX Clinac was modeled including the major geometric structures within the beam path such as a target, a primary collimator, a flattening filter, a ion chamber, and jaws. The 6 MV photon spectra were characterized in a standard $10{\times}10cm^2$ field at 100 cm source-to-surface distance(SSD) and subsequent dose estimations were made in a water phantom. The measurements of percentage depth dose and dose profiles were performed with 3D water phantom and the simulated data was compared to measured reference data. The simulated results agreed very well with the measured data. It has been found that the GATE6 code is an effective tool for dose optimization in radiotherapy applications.

A Study on the Validation of Effective Angle of Particle Deposition according to the Detection Efficiency of High-purity Germanium Gamma-ray Detector (고순도 저마늄 감마선 검출기의 검출효율에 따른 유효입체각 검증에 관한 연구)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.487-494
    • /
    • 2020
  • The distance between the source and the detector, the diameter of the detector, and the volume effect of the radiation source result in a change in solid angle at the detector entrance, which affects the determination of detection efficiency by causing a difference in path length within the detector. A typical analysis method for calculating solid angles was useful only for a source (60Co) with a simple geometric structure, so in this experiment, the distance between the detector and the source was measured by switching on for up to 25 cm with the reference point of window cap 0.5 cm. In addition, 450 and 1000 ㎖ Marinelli beaker of standard volumetric sources were closely adhered to the detector. For circular point sources co-axial with the detector, the change in the solid angle to the distance from the detector window is equal to half the square radius of the source versus the square radius of the detector, if the resulting relationship of the calculation analysis results in the detector being less than the radius of the source. Since the solid angular difference is 0.5 the result of Monte Carlo is acceptable. The relationship between detector and source distance is shown. Solid angles have been verified to decrease rapidly with distance. Measurement and simulation results for a volumetric source show a difference of ±1.01% from a distance of 0 cm and less than 4 % when the distance is reduced to 5 and 10 cm. It can be seen that the longer distance, the smaller efficiency angle, and the exponential increase in attenuation as the energy decreases, is reflected in the calculation of efficiency. Thus, the detection efficiency has proved sufficient for the use of solid angle and Monte Carlo codes.

Study on international accreditation for residue analysis laboratory (잔류물질분석의 국제공인시험기관 인정 관련 고찰)

  • Kim, MeeKyung;cho, Byung-Hoon;Kim, Dong-Gyu;Yun, Seon Jong;Lim, Chae-Mi;Park, Su-Jeong;Kim, Heuijin;Kim, Yeon Hee;Kim, Soo-Yeon;Yun, So Mi;Kwon, Jin-Wook;Son, Seong-Wan;Chung, Gab-Soo;Lee, Joo-Ho;Kang, Mun-Il
    • Korean Journal of Veterinary Research
    • /
    • v.46 no.4
    • /
    • pp.295-304
    • /
    • 2006
  • Residual materials such as veterinary drugs, environmental contaminants, and pesticides are affecting food safety. High resolution techniques and quality controls are needed to analyze these materials from part per million to part per trillion quantities in food. In order to achieve quality results, standardized methods and techniques are required. Our laboratories were prepared to obtain a certificate of accreditation for ISO/IEC 17025 in the analytical criteria of animal drugs, dioxins, pesticides, and heavy metals. ISO together with IEC has built a strategic partnership with the World Trade Organization with the common goal of promoting a free and fair global trading system. ISO collaborates with the United Nations Organization and its specialized agencies and commissions, particularly those involved in the harmonization of regulations and public policies including the World Health Organization and CODEX Alimentarius for food safety measurement, management and traceability. Our goal was to have high quality analysts, proper analytical methods, good laboratory facilities, and safety systems within guidelines of ISO/IEC 17025. All staff members took requirement exams. We applied proficiency tests in the analysis of veterinary drugs (nitrofuran metabolites, sulfonamide and tetracyclines), dioxins, organophosphorus pesticides, and heavy metals (Cd, Pb, As) to the Food Analysis Performance Assessment Scheme (FAPAS) at Central Science Laboratory, Department for Environment Food and Rural Affairs (DEFRA), England. The results were very satisfactory. All documents were prepared, including system management, laboratory management, standard operational procedures for testing, reporting, and more. The criteria encompassed the requirements of ISO/IEC 17025:1999. Finally, the Korea Laboratory Accreditation Scheme (KOLAS) accredited our testing laboratories in accordance with the provisions of Article 23 of the National Standards Act. The accreditation will give us the benefit of becoming a regional reference laboratory in Asia.

Availability of the Time and Change Test in Screening for Dementia in the Elderly (노인에서 치매 조기선별을 위한 시각.금전계산 검사의 유용성)

  • Chung, Eun-Kyung;Shin, Min-Ho;Rhee, Jung-Ae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.2
    • /
    • pp.101-107
    • /
    • 2003
  • Objectives : Dementia has emerged as a leading public health problem in elderly persons, and its early detection is important for the treatment of curable cases, and in the educational support for other family members. Although dementia screening tests are available, they have not gained widespread use in community or primary care settings. Our goal was to validate the Tine and Change (T&C) Test, -including its validity and reliability in patients, and to assess it as a simple, standardized method for the screening of dementia in the rural elderly. Methods : The participants in this study comprised of 59 patients from an urban hospital and 405 persons from a rural community aged 65 years or older. The time test evaluated the understanding of clock hands indicating 11:10, and the change test the ability to make 1,000 Won from a group of coins, consisting of one 500, seven 100, and seven 50 Won coins. The T&C ratings were validated against a reference standard based on the physician's diagnosis of the patients. The convergent validity in relation to other cognitive measure, test-retest agreement, and inter-observer reliability were assessed. To assess the relationship between the Korean Mini-Mental State Exam (K-MMSE) and the T&C Test, the mean K-MMSE scores were compared with the results of the T&C Test in the elderly from a rural community. Results The T&C Test had a sensitivity and specificity of 73.0, and 90.9%, and positive and negative predictive values of 93.1, and 66.7%, respectively. The test-retest and inter-observer agreement rates were both 95%. The K-MMSE scores and T&C Test were significantly related in the elderly from a rural community (p<0.01), The T&C Test was not influenced by the educational status. The Time and Change Tests took a mean of 6.3 and 12.7 seconds, respectively, to complete Conclusion : The T&C Test is a simple, accurate and reliable, performance-based tool in the screening for dementia. Because it is quick, and easy-to-use, it is hoped the T&C Test will be used for the widespread cognitive screening of aging populations.

On-site Water Nitrate Monitoring System based on Automatic Sampling and Direct Measurement with Ion-Selective Electrodes

  • Kim, Dong-Wook;Jung, Dae-Hyun;Cho, Woo-Jae;Sim, Kwang-Cheol;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.350-357
    • /
    • 2017
  • Purpose: In-situ monitoring of water quality is fundamental to most environmental applications. The high cost and long delays of conventional laboratory methods used to determine water quality, including on-site sampling and chemical analysis, have limited their use in efficiently managing water sources while preventing environmental pollution. The objective of this study was to develop an on-site water monitoring system consisting mainly of an Arduino board and a sensor array of multiple ion selective electrodes (ISEs) to measure the concentration of $NO_3$ ions. Methods: The developed system includes a combination of three ISEs, double-junction reference electrode, solution container, sampling system consisting of three pumps and solenoid valves, signal processing circuit, and an Arduino board for data acquisition and system control. Prior to each sample measurement, a two-point normalization method was applied for a sensitivity adjustment followed by an offset adjustment to minimize the potential drift that could occur during continuous measurement and standardize the response of multiple electrodes. To investigate its utility in on-site nitrate monitoring, the prototype was tested in a facility where drinking water was collected from a water supply source. Results: Differences in the electric potentials of the $NO_3$ ISEs between 10 and $100mg{\cdot}L^{-1}$ $NO_3$ concentration levels were nearly constant with negative sensitivities of 58 to 62 mV during the period of sample measurement, which is representative of a stable electrode response. The $NO_3$ concentrations determined by the ISEs were almost comparable to those obtained with standard instruments within 15% relative errors. Conclusions: The use of the developed on-site nitrate monitoring system based on automatic sampling and two-point normalization was feasible for detecting abrupt changes in nitrate concentration at various water supply sites, showing a maximum difference of $4.2mg{\cdot}L^{-1}$ from an actual concentration of $14mg{\cdot}L^{-1}$.

Study on Determination of Boron using the PGAA Facility at HANARO Research Reactor (하나로의 즉발감마선 방사화분석 장치를 이용한 붕소의 정량에 대한 연구)

  • Chung, Young-Sam;Cho, Hyun-Jae;Moon, Jong-Hwa;Kim, Sun-Ha;Kim, Young-Jin
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.391-398
    • /
    • 2003
  • Basic research for the determination of boron content in biological sample has been carried out using the PGAA facility of the 24MW research reactor(HANARO). For investigation of characteristics for the measurement condition, neutron flux and its homogeneity were measured at irradiating geometry. The size of thermal neutron beam collimated from beam guide is $2{\times}2cm^2$ at the sample position. The neutron flux measured was the range of $1.0{\sim}6.5{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$, and flux distribution from center within the radius of 4.5 mm and 9.0 mm was $5.77{\pm}0.71{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$ and $4.68{\pm}1.64{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$, respectively. Accordingly, sample size is adjusted within 10 mm for a homogeneous irradiation of high quality. Measurement system is designed to reduce the background source by Compton scattering and to improve the analytical sensitivity. To investigate the energy calibration and Compton suppression effect of gamma-ray counting system, the background conditions on both of Compton and single-mode were measured using NaCl standard. On the other hand, degree of spectral interference for sodium 472 keV peak as a matrix effect in the sample is established for an accurate boron analysis, and then boron content in three certified reference materials (NIST SRM 1570a, 1547, 1573a) was measured by using two modes and the results were compared with each other.

Bioequivalence of Samchundang Lercanidipine Tablet 10 mg to Zanidip Tablet (Lercanidipine Hydrochloride 10 mg) by Liquid Chromatography with Tandem Mass Spectrometry

  • Kim, Se-Mi;Kim, Hwan-Ho;Shin, Sae-Byeok;Kang, Hyun-Ah;Cho, Hea-Young;Kim, Yoon-Gyoon;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.5
    • /
    • pp.315-321
    • /
    • 2007
  • The purpose of the present study was to evaluate the bioequivalence of two lercanidipine hydrochloride tablets, Zanidip tablet (LG Life Sciences Ltd., Korea, reference drug) and Samchundang Lercanidipine tablet 10 mg (Sam Chun Dang Pharm. Co. Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). After adding an internal standard (amlodipine maleate) to human serum, serum samples were extracted using hexan-isoamyl alcohol (100:1, v/v). Compounds were analyzed by liquid chromatography/tandem mass spectrometry. This method showed linear response over the concentration range of 0.05-20 ng/mL with correlation coefficient of 0.9999. The lower limit of quantitation using 0.5 mL of serum was 0.05 ng/mL which was sensitive enough for pharmacokinetic studies. Thirty healthy male Korean volunteers received each medicine at the lercanidipine hydrochloride dose of 20 mg in a $2\;{\times}\;2$ crossover study. There was a one-week washout period between the doses. Serum concentrations of lercanidipine were monitored by an LC/MS/MS fer over a period of 24 hr after the administration. $AUC_t$ (the area under the serum concentration-time curve from time 0 to 24 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (the maximum serum drug concentration) and $T_{max}$ (the time to reach $C_{max}$) were compiled from the serum concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters, indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Samchundang Lercanidipine/Zanidip were log 0.9505-log 1.2258 and log 0.9987-log 1.2013, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Samchundang Lercanidipine tablet 10 mg and Zanidip tablet are bioequivalent.

Comparison of Observed Wave Height and Wave Image of Sok-cho Site (속초연안지점의 관측파고와 파영상자료의 비교)

  • Jang, Bok-Jin;Yeo, Woon-Kwang;Lee, Jong-Kook;Park, Kwang-Soon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.4
    • /
    • pp.329-335
    • /
    • 2007
  • The eye measurement to observe the sea surface condition and estimate the wave height has been used in the open sea or the ship. The experts in the eye estimation can measure the wave height very accurately. The Beaufort wind scale is most widely used as a standard index of the eye measurement. However, more definite reference data such as the representative images by each wave heights must be necessary because the appearances and explanations in the Beaufort wind scale are not enough to understand the sea surface condition far the researcher and the public. The modern field data acquisition technique has been developed to measure wave heights, ocean weather data and even images of the sea surface in real-time. In this study, the wireless field image transmitting system for wave heights and images is installed in the real-time ocean measurement system of Chodo light tower near Sokcho city in South Korea. The wave heights and surface images acquired from the real time system in the field are compared with explanations of the Beaufort wind scale. The wave heights and images measured with the precision ultrasonic wave sensor and the scientific sea surface image transmitting system should be helpful to obtain more precise and definite information than the data from the Beaufort wind scale.

The Maintenance Process Model using BPMN Method in Public Rental Housing (BPMN 방식을 이용한 공공임대주택 유지관리 업무 프로세스 모델)

  • Park, Kyung-Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.743-751
    • /
    • 2016
  • It is critical to effectively change the measures of prevention from the breakdown maintenance proceeding an apartment housing maintenance task scope. It is necessary that systematization be performed for a series of tasks, such as facility inspection, diagnosis and replacement. In addition, it is preceded by establishing a standardization for maintenance work scope. Therefore, this study examined the problems related to public rental housing maintenance work scope to manage it more systematically. In addition, the study suggests a work process section for facility repairs, long term replacement and general maintenance using one on one interviews with experts to classify the occupants, management office and head office. This study's standard work system is expected to provide fairness and transparency in addition to improving the productivity in public rental housing maintenance via an efficiency promotion plan. In addition, it is used as the basic reference for developing a system of public rental housing maintenance costs and diagnosis actions. Finally, it is necessary to create improvements that provide a more objective work system standardization throughout the analysis of the productivity data according to the work flow and the review of the occupants, management office and head office in the future applications of the pilot site.

Estimation of Longitudinal Dynamic Stability Derivatives for a Tailless Aircraft Using Dynamic Mesh Method (Dynamic Mesh 기법을 활용한 무미익 비행체 종축 동안정 미계수 예측)

  • Chung, Hyoung-Seog;Yang, Kwang-Jin;Kwon, Ky-Beom;Lee, Ho-Keun;Kim, Sun-Tae;Lee, Myung-Sup;Reu, Taekyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.3
    • /
    • pp.232-242
    • /
    • 2015
  • For stealth performance consideration, many UAV designs are adopting tailless lambda-shaped configurations which are likely to have unsteady dynamic characteristics. In order to control such UAVs through automatic flight control system, more accurate estimation of dynamic stability derivatives becomes essential. In this paper, dynamic stability derivatives of a tailless lambda-shaped UAV are estimated through numerically simulated forced oscillation method incorporating dynamic mesh technique. First, the methodology is validated by benchmarking the CFD results against previously published experimental results of the Standard Dynamics Model(SDM). The dependency of initial angle of attack, oscillation frequency and oscillation magnitude on the dynamic stability derivatives of a tailless UAV configuration is then studied. The results show reasonable agreements with experimental reference data and prove the validity and efficiency of the concept of using CFD to estimate the dynamic derivatives.