• Title/Summary/Keyword: reference room

Search Result 266, Processing Time 0.027 seconds

Channel Model and Wireless Link Performance Analysis for Short-Range Wireless Communication Applications in the Terahertz Frequency (테라헤르츠 대역 주파수에서 근거리 무선 통신 응용을 위한 채널 모델 및 무선 링크 성능 분석)

  • Chung, Tae-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.868-882
    • /
    • 2009
  • In this paper, channel model and wireless link performance analysis for the short-range wireless communication system applications in the terahertz frequency which is currently interested in many countries will be described. In order to realize high data rates above 10 Gbps, the more wide bandwidths will be required than the currently available bandwidths of millimeter-wave frequencies, therefore, the carrier frequencies will be pushed to THz range to obtain larger bandwidths. From the THz atmospheric propagation characteristics based on ITU-R P.676-7, the available bandwidths were calculated to be 68, 48 and 45 GHz at the center frequencies of 220, 300 and 350 GHz, respectively. With these larger bandwidths, it was shown from the simulation that higher data rate above 10 Gbps can be achieved using lower order modulation schemes which have spectral efficiency of below 1. The indoor propagation delay spread characteristics were analyzed using a simplified PDP model with respect to building materials. The RMS delay spread was calculated to be 9.23 ns in a room size of $6\;m(L){\times}5\;m(W){\times}2.5\;m(H)$ for the concrete plaster with TE polarization, which is a similar result of below 10 ns from the Ray-Tracing simulation in the reference paper. The indoor wireless link performance analysis results showed that receiver sensitivity was $-56{\sim}-46\;dBm$ over bandwidth of $5{\sim}50\;GHz$ and antenna gain was calculated to be $26.6{\sim}31.6\;dBi$ at link distance of 10m under the BPSK modulation scheme. The maximum achievable data rates were estimated to be 30, 16 and 12 Gbps at the carrier frequencies of 220, 300 and 350 GHz, respectively, under the A WGN and LOS conditions, where it was assumed that the output power of the transmitter is -15 dBm and link distance of 1 m with BER of $10^{-12}$. If the output power of transmitter is increased, the more higher data rate can be achieved than the above results.

An Alternative Method for a Rapid Urease Test Using Back-table Gastric Mucosal Biopsies from Gastrectomy Specimen for Making the Diagnosis of Helicobacter pylori Infection in Patients with Gastric Cancer (위암 환자의 헬리코박터 파이로리 감염 진단에 있어서 위절제술 직후 생검된 위점막 조직을 이용한 신속 요소 분해 효소 검사법 도입의 의의)

  • Kim, Sin-Ill;Jin, Sung-Ho;Lee, Jae-Hwan;Min, Jae-Seok;Bang, Ho-Yoon;Lee, Jong-Inn
    • Journal of Gastric Cancer
    • /
    • v.9 no.4
    • /
    • pp.172-176
    • /
    • 2009
  • Purpose: The rapid urease test is a rapid and reliable method for diagnosing Helicobacter pylori infection. However it requires gastric mucosal biopsies during endoscopy, and the test is not covered by national health insurance for patients with gastric cancer. So, we introduced an alternative method for a rapid urease test using back-table gastric mucosal biopsies from gastrectomy specimen. Materials and Methods: Ninety gastric cancer patients underwent an anti H. pylori IgG ELISA test and gastrectomy. Just after gastrectomy, two gastric mucosal biopsies from the prepyloric antrum and lower body of the gastrectomy specimen were taken from the back table in the operative room, and these were fixed immediately with the rapid urease test kit, and the color change was monitored for up to 24 hours. In this study, H. pylori infection was defined as positive when the serology or rapid urease test showed positive results. Results: The positive rate of the rapid urease test and serology was 91.1% and 77.8%, respectively. The sensitivity, specificity, positive predictive value and negative predictive value of the rapid urease test and serology were 94.3 and 80.5%, 100 and 100%, 100 and 100%, and 37.5 and 15%, respectively. The accuracy of the rapid urease test was higher than that of serology (94.4 vs. 81.1%, respectively). The rapid urease test showed a higher rate of detecting H. pylori infection than that of serology (McNemar's test, P=0.019). Conclusion: The result of the rapid urease test using back-table gastric mucosal biopsies from a gastrectomy specimen is comparable to the reference data of the conventional rapid urease test using gastric mucosal endoscopic biopsies. Therefore, it can be an alternative diagnostic method for H. pylori infection.

  • PDF

Clinical Usefulness of Arterial Spin Labeling Perfusion MR Imaging in Acute Ischemic Stroke (급성 허혈성 뇌경색 환자에서 동맥스핀표지 관류자기공명영상의 유용성)

  • Oh, Keun-Taek;Jung, Hong-Ryang;Lim, Cheong-Hwan;Cho, Young-Ki;Ha, Bon-Chul;Hong, Doung-Hee
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.323-331
    • /
    • 2011
  • We evaluated clinical usefulness of Arterial spin labeling perfusion MR imaging on the acute ischemic cerebral infarction patients through this study. We compared 22 patients who were done with DSC imaging and ASL imaging in admitted emergency room with acute ischemic cerebral infarction, with 36 normal comparison persons (DSC image on 21persons, ASL images on 15persons). Siemens Magnetom Verio 3.0T with 12 channel head coil was used for this study. DSC image obtained 4 maps(rCBV, rCBF, rMTT, TTP) through post-processing. For qualitative analysis we compared the area of lesion macro-diagonal with the size of diffusion weighted MR image for rMTT, TTP, rCBF, rCBV, ASL maps. For Quantitative analysis we analyzed significant correlations between less than 3 cm infarction group and normal comparison group using mean relative value of flowing image with Mann-Whitney U test. TTP(95.5%) and rCBF(95.5%) maps showed high recognition rate in qualitative analysis for >3cm infarction group. The rCBF and rCBV map tests were highly related with final stage stroke areas. Mean relative value of infarction group showed a significant correlations in quantitative analysis(p<0.05). As a conclusion, arterial spin labeling image showed high lesion recognition rate in the >3cm infarction group. Mean relative values in quantitative evaluation were used for reference data. If we do more sustainable researches, ASL image will be useful for an early diagnosis of cerebral infarction, determination of the range of ischemic pneumbra and effective treatments.

A Survey on Preliminary Dental Hygienists' Senses of Employment (예비치과위생사의 취업에 관한 의식 조사)

  • Han, Su-Jin;Lee, Sun-Mi;Lim, Mi-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.4
    • /
    • pp.583-594
    • /
    • 2007
  • The purpose of this study was to conduct a survey on the senses that preliminary dental hygienists have on employment, who applied for the National Dental Hygienist Examination, so that it could provide a basic reference required for fostering good human resources specializing in oral health with a sense of mission and responsibility as professional. To meet these goals, a self-administered questionnaire survey was conducted for participants in a refresher education meeting for preliminary dental hygienists across three major regions(Seoul, Daejeon and Busan), which was held by the Korean Dental Hygienists Association(KDHA) on Jan. 15, 2006. Total 289 sheets of questionnaire were collected, and 262 sheets except invalid or incomplete ones were used for examination and analysis. As a result, this study came to the following conclusions: First, it was found that 40.4% respondents wanted to be employed in dental clinic or hospital. Most respondents(90.1%) answered that faithfulness is most valued as prerequisite qualification for employment in hospital, and highest percentage of respondents(39.3%) wanted to earn 16 to 17 million Korean won annually. For internship opportunities, 61.9% respondents replied that they could willingly accept the internship, provided that basic pay and switchover to regular employee are all assured. Second, as the results of survey on employment circumstances around respondents, it was found that most respondents(58.3%) were employed in dental clinic or hospital, and highest percentage of respondents(35.0%) earned 15 to 16 million Korean won. Third, it was found that interpersonal relationships among employees had most significant effects(4.81) on selection of employment, which was followed by in-house welfare benefits 1(monthly/annual vacation, resting room, etc; 4.56). For possible influential factors on the selection of employment depending on whether employed or not, it was found that there were Significant differences in pay, welfare benefit 2(seminar, orientation, refresher training opportunities, etc), post-wedding continued employment and merit system between employees and non-employees(pE0.05). Fourth, the survey on respondents' occupational senses of dental hygienist showed that major tasks of dental hygienists were represented by oral disease prevention(92.6%), case management(71.5%), oral health education(66.3%), hospital/clinic management and dental management support(10.4%) and public oral health activities(6.7%) respectively. For job satisfaction, it was found that almost half respondents(48.9%) showed satisfaction at their job and 32.6% felt satisfied at and proud of their job. That is, majority of respondents(81.5%) felt satisfied at their job as dental hygienist. For follow-up requirements to qualify for dental hygienists, it was found that 73.3% felt it necessary to give more investments to self-development, 62.2% respondents considered protection of membership's rights as one of future assignments that KDHA should be more committed to. For future social awareness about dental hygienists as occupation, 69.2% respondents expected that they would be better developed and treated as professional. And desired training courses as a part of qualification for professional dental hygienists were represented by case management(services, manners, etc; 33.3%), implant(28.9%), esthetics(correction, prosthesis, whitening; 18.9%) and so on. For an item on working years, it was noted that 75.9% respondents would keep working as dental hygienists as long as they could.

  • PDF

Consideration of a Bacteria Contamination Management in the Dispensation of 99mTc Radiopharmaceutical (테크네슘 방사성의약품의 조제와 분배 과정에서 오염균에 대한 고찰)

  • Choi, Do Chul;Gim, Yeong Su;Jo, Gwang Mo;Gim, Hui Jeong;Seo, Han Gyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.84-87
    • /
    • 2018
  • Purpose The radiopharmaceutical used in the nuclear medicine department is used only for the specific patient according to the prescription or instruction of the doctor without selling, so it is dispensed and it is distributed and used for the examination. Radiopharmaceuticals administered to patients should be managed appropriately as well as radiation safety management during dispensation. The purpose of this study is to investigate microbial contamination during dispensation of radiopharmaceuticals Materials and Methods This study distinguished between general workbench and clean workbench and performed three tests. First, microbial cultivation test of radiopharmaceutical prepared and dispensed in general workbenches and sterile workbenches were carried out five times, respectively. The second test was performed settle plate method three times before and after the use of the exhaust filter. Finally, Adenosine Triphosphate (ATP) measurement was performed in each workbench to measure bacterial counts. In addition, ATP measurement were carried out by designating locations and items that may be contaminated during dispensation. Results In the microbial culture test, no microorganisms were detected in both samples. In the settle plate method, it was detected without using of the exhaust filter in a general workbench once. In the ATP measurement test, it was measured at the level of 400 RLU or less, which is the standard value of contamination, in both workbenches surface. In additional ATP measurement test, the refrigerator handle in the distribution room was measured above the reference value of 1217 RLU, the vacuum vial shield of the Tech Generator at 435 RLU, and the syringe holder at 1357 RLU. After environmental disinfection, the results were reduced to 311 RLU, 136 RLU, and 291 RLU. Conclusion No contamination by bacteria was found in both workbenches. However, microbial contamination may occur if the use of an exhaust filter or proper hand hygiene is not achieved. Regular inspections and management for aseptic processing themselves will be necessary.

Comparative study of volumetric change in water-stored and dry-stored complete denture base (공기중과 수중에서 보관한 총의치 의치상의 체적변화에 대한 비교연구)

  • Kim, Jinseon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.18-26
    • /
    • 2021
  • Purpose: Generally, patients are noticed to store denture in water when removed from the mouth. However, few studies have reported the advantage of volumetric change in underwater storage over dry storage. To be a reference in defining the proper denture storage method, this study aims to evaluate the volumetric change and dimensional deformation in case of underwater and dry storage. Materials and methods: Definitive casts were scanned by a model scanner, and denture bases were designed with computer-aided design (CAD) software. Twelve denture bases (upper 6, lower 6) were printed with 3D printer. Printed denture bases were invested and flasked with heat-curing method. 6 upper and 6 lower dentures were divided into group A and B, and each group contains 3 upper and 3 lower dentures. Group A was stored dry at room temperature, group B was stored underwater. Group B was scanned at every 24 hours for 28 days and scanned data was saved as stereolithography (SLA) file. These SLA files were analyzed to measure the difference in volumetric change of a month and Kruskal-Wallis test were used for statistical analysis. Best-fit algorithm was used to overlap and 3-dimensional color-coded map was used to observe the changing pattern of impression surface. Results: No significant difference was found in volumetric changes regardless of the storage methods. In dry-stored denture base, significant changes were found in the palate of upper jaw and posterior lingual border of lower jaw in direction away from the underlying tissue, maxillary tuberosity of upper jaw and retromolar pad area of lower jaw in direction towards the underlying tissue. Conclusion: Storing the denture underwater shows less volumetric change of impression surface than storing in the dry air.