• Title/Summary/Keyword: reference materials

Search Result 1,945, Processing Time 0.038 seconds

Comparative evaluation of dose according to changes in rectal gas volume during radiation therapy for cervical cancer : Phantom Study (자궁경부암 방사선치료 시 직장가스 용적 변화에 따른 선량 비교 평가 - Phantom Study)

  • Choi, So Young;Kim, Tae Won;Kim, Min Su;Song, Heung Kwon;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.89-97
    • /
    • 2021
  • Purpose: The purpose of this study is to compare and evaluate the dose change according to the gas volume variations in the rectum, which was not included in the treatment plan during radiation therapy for cervical cancer. Materials and methods: Static Intensity Modulated Radiation Therapy (S-IMRT) using a 9-field and Volumetric Modulated Arc Therapy (VMAT) using 2 full-arcs were established with treatment planning system on Computed Tomography images of a human phantom. Random gas parameters were included in the Planning Target Volume(PTV) with a maximum change of 2.0 cm in increments of 0.5 cm. Then, the Conformity Index (CI), Homogeneity Index (HI) and PTV Dmax for the target volume were calculated, and the minimum dose (Dmin), mean dose (Dmean) and Maximum Dose (Dmax) were calculated and compared for OAR(organs at risk). For statistical analysis, T-test was performed to obtain a p-value, where the significance level was set to 0.05. Result: The HI coefficients of determination(R2) of S-IMRT and VMAT were 0.9423 and 0.8223, respectively, indicating a relatively clear correlation, and PTV Dmax was found to increase up to 2.8% as the volume of a given gas parameter increased. In case of OAR evaluation, the dose in the bladder did not change with gas volume while a significant dose difference of more than Dmean 700 cGy was confirmed in rectum using both treatment plans at gas volumes of 1.0 cm or more. In all values except for Dmean of bladder, p-value was less than 0.05, confirming a statistically significant difference. Conclusion: In the case of gas generation not considered in the reference treatment plan, as the amount of gas increased, the dose difference at PTV and the dose delivered to the rectum increased. Therefore, during radiation therapy, it is necessary to make efforts to minimize the dose transmission error caused by a large amount of gas volumes in the rectum. Further studies will be necessary to evaluate dose transmission by not only varying the gas volume but also where the gas was located in the treatment field.

Step-by-Step Growth Factors for Technology-Based Ventures: A Case Study of Advanced Nano Products Co. Ltd (기술기반 벤처기업의 단계별 성장요인: (주)나노신소재 사례 중심으로)

  • Jeong, Chanwoo;Lee, Wonil
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.16 no.6
    • /
    • pp.85-105
    • /
    • 2021
  • In this study, a case study was conducted on Advanced Nano Products Co.,Ltd, a company that was established in 2000 and has the core technology to produce and commercialize nano materials and ultrafine nano powders based on nano technology. Deviating from the general case study, a case study analysis frame was set based on the theory of technology management and industry-university cooperation theory, and cases were analyzed. In this case study, Advanced Nano Products Co.,Ltd. was analyzed from two analytical perspectives: the establishment of a Management Of Technology system within the company and the Industry-Academic Cooperation activity. Based on this theoretical-based analysis framework, company visit interviews and related data research and analysis were conducted. As a result of the study of the case company, it was possible to derive how the technology management and industry-university cooperation affect the growth stage of the company as follows. First, the strategic use of technology management is an important factor in strengthening the competitive advantage and core competencies of venture companies, and for survival and growth of startups in the early stages. Second, strategic use of technology management and patents and establishment of a patent management system are a part of business strategy and play a pivotal role in corporate performance. Third, the human and material infrastructure of universities affects the growth of companies in the early stage of start-up, and the high utilization of industry-university cooperation promotes the growth of companies. Fourth, continuous industry-academic cooperation activities in the growth and maturity stages of a company's growth stage are the basis for activating external exchanges and building networks. Lastly, technology management and industry-university cooperation were found to be growth factors for each growth stage of a company. In order for a company to develop continuously from the start-up to the growth and maturity stages, it is necessary to establish a technology management system from the beginning and promote strategic technology management activities. In addition, it can be said that it is important to carry out various industry-academic cooperation activities outside the company. As a result of the case analysis, it was found that Advanced Nano Products Co.,Ltd, which performed these two major activities well, overcame the crisis step by step and continued to grow until now. This study shows how the use of technology management and industry-academic cooperation creates value in each growth stage of technology-based venture companies. In addition, its active use will play a big role in the growth of other venture companies. The results of this case study can be a valid reference for growth research of technology start-up venture companies and related field application and utilization.

Transcriptomic Analysis of Triticum aestivum under Salt Stress Reveals Change of Gene Expression (RNA sequencing을 이용한 염 스트레스 처리 밀(Triticum aestivum)의 유전자 발현 차이 확인 및 후보 유전자 선발)

  • Jeon, Donghyun;Lim, Yoonho;Kang, Yuna;Park, Chulsoo;Lee, Donghoon;Park, Junchan;Choi, Uchan;Kim, Kyeonghoon;Kim, Changsoo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.67 no.1
    • /
    • pp.41-52
    • /
    • 2022
  • As a cultivar of Korean wheat, 'Keumgang' wheat variety has a fast growth period and can be grown stably. Hexaploid wheat (Triticum aestivum) has moderately high salt tolerance compared to tetraploid wheat (Triticum turgidum L.). However, the molecular mechanisms related to salt tolerance of hexaploid wheat have not been elucidated yet. In this study, the candidate genes related to salt tolerance were identified by investigating the genes that are differently expressed in Keumgang variety and examining salt tolerant mutation '2020-s1340.'. A total of 85,771,537 reads were obtained after quality filtering using NextSeq 500 Illumina sequencing technology. A total of 23,634,438 reads were aligned with the NCBI Campala Lr22a pseudomolecule v5 reference genome (Triticum aestivum). A total of 282 differentially expressed genes (DEGs) were identified in the two Triticum aestivum materials. These DEGs have functions, including salt tolerance related traits such as 'wall-associated receptor kinase-like 8', 'cytochrome P450', '6-phosphofructokinase 2'. In addition, the identified DEGs were classified into three categories, including biological process, molecular function, cellular component using gene ontology analysis. These DEGs were enriched significantly for terms such as the 'copper ion transport', 'oxidation-reduction process', 'alternative oxidase activity'. These results, which were obtained using RNA-seq analysis, will improve our understanding of salt tolerance of wheat. Moreover, this study will be a useful resource for breeding wheat varieties with improved salt tolerance using molecular breeding technology.

Influence of finish line design on the marginal fit of nonprecious metal alloy coping fabricated by 3D printing, milling and casting using CAD-CAM (CAD-CAM을 이용한 3D printing, milling, casting 방법의 비귀금속 코핑의 지대치 변연 적합도 연구)

  • Seo-Rahng Kim;Myung-Joo Kim;Ji-Man Park;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.1-17
    • /
    • 2023
  • Purpose. The purpose of this study was to examine the correlation between the finish line designs and the marginal adaptation of nonprecious metal alloy coping produced by different digital manufacturing methods. Materials and methods. Nonprecious metal alloy copings were made respectively from each master model with three different methods; SLS, milling and casting by computer aided design and computer aided manufacturing (CAD-CAM). Twelve copings were made by each method resulting in 72 copings in total. The measurement was conducted at 40 determined reference points along the circumferential margin with the confocal laser scanning microscope at magnification ×150. Results. Mean values of marginal gap of laser sintered copings were 11.8 ± 7.4 ㎛ for deep chamfer margin and 6.3 ± 3.5 ㎛ for rounded shoulder margin and the difference between them was statistically significant (P < .0001). Mean values of marginal gap of casted copings were 18.8 ± 20.2 ㎛ for deep chamfer margin and 33 ± 20.5 ㎛ for rounded shoulder margin and the difference between them was significant (P = .0004). Conclusion. Within the limitation of this study, the following conclusions were drawn. 1. The variation of finish line design influences the marginal adaptation of laser sintered metal coping and casted metal coping. 2. Laser sintered copings with rounded shoulder margin had better marginal fit than deep chamfer margin. 3. Casted copings with deep chamfer margin had better marginal fit than rounded shoulder margin. 4. According to the manufacturing method, SLS system showed the best marginal fit among three different methods. Casting and milling method followed that in order.

Reliable Radiologic Parameters to Predict Surgical Management for Clubfoot Treated with the Ponseti Method (Ponseti 방법으로 치료를 시작한 선천성 만곡족 환자에서 수술적 치료 여부를 예측할 수 있는 방사선적 지표)

  • Song, Kwang Soon;Yon, Chang Jin;Lee, Si Wook;Lee, Yong Ho;Um, Sang Hyun;Kwon, Hyuk Jun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.59-66
    • /
    • 2019
  • Purpose: Several radiologic reference lines have been used to evaluate individuals with a clubfoot but there is no consensus as to which is most reliable. The aim of this study was to identify which radiologic parameters have relevance to the predictability of additional surgery after Ponseti casting on clubfoot and the effect of clubfoot treatments that contain Ponseti casting and additional surgery. Materials and Methods: A total of 102 clubfeet (65 patients, 37 bilateral) were reviewed from 2005 to 2013. The patients were divided into two groups (Group A, those for whom the result of the Ponseti method was successful and did not require additional surgery; and Group B, those for whom the result of the Ponseti method was unsuccessful and required additional surgery), and the following parameters were measured on the plain radiographs: i) talo-calcaneal angle on the anteroposterior and lateral view, ii) talo-1st metatarsal angle on the anteroposterior view, and iii) Tibio-calcaneal angle on the lateral view with the ankle full-dorsiflexion state. Each radiograph was reviewed on two separate occasions by one orthopedic doctor to characterize the intra-observer reliability, and the averages were analyzed. Next, 20 cases were chosen using a random number table, and two orthopedic doctors measured the angle separately to characterize the interobserver reliability. Results: Groups A and B included 73 clubfeet (71.6%) and 29 clubfeet (28.4%), respectively. The initial talo-calcaneal angle and tibiocalcaneal angle in the lateral view were significantly different among the groups. In addition, inter- and intra-observer biases were not detected. The talo-1st metatarsal angle on the anteroposterior view and tibio-calcaneal angle on the lateral view were significantly different after treatment in both groups. Conclusion: Congenital clubfeet treated with the Ponseti method showed successful results in more than 70% of patients. The initial talocalcaneal angle and tibio-calcaneal angle on the lateral view were the radiologic parameters that could predict the need for additional surgical treatments. The talo-1st metatarsal angle on the anteroposterior view and tibio-calcaneal angle on the lateral view could effectively evaluate the changes in clubfoot after treatment.

A Study on the Performance Verification Method of Small-Sized LTE-Maritime Transceiver (소형 초고속해상무선통신망 송수신기 성능 검증 방안에 관한 연구)

  • Seok Woo;Bu-young Kim;Woo-Seong Shim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.7
    • /
    • pp.902-909
    • /
    • 2023
  • This study evaluated the performance test of a small-sized LTE-Maritime(LTE-M) transceiver that was developed and promoted to expand the use of intelligent maritime traf ic information services led by the Ministry of Oceans and Fisheries with the aim of supporting the prevention of maritime accidents. Accoriding to statistics, approximately 30% of all marine accidents in Korean water occur with ships weighing less than 3 tons. Therefore, the blind spots of maritime safety must be supplemented through the development of small-sized transceivers. The small transceiver may be used in fishing boats that are active near coastal waters and in water leisure equipment near the coastline. Therefore, verifying whether sufficient performance and stable communication quality are provided is necessary, considering the environment of their real usage. In this study, we reviewed the communication quality goals of the LTE-M network and the performance requirements of small-sized transceivers suggested by the Ministry of Oceans and Fisheries, and proposed a test plan to appropriately evaluate the performance of small-sized transceivers. The validity of the proposed test method was verified for six real-sea areas with a high frequency of marine accidents. Consequently, the downlink and uplink transmission speeds of the small-sized LTE-M transceiver showed performances of 9 Mbps or more and 3 Mbps or more, respectively. In addition, using the coverage analysis system, coverage of more than 95% and 100% were confirmed in the intensive management zone (0-30 km) and interesting zone (30-50 km), respectively. The performance evaluation method and test results proposed in this paper are expected to be used as reference materials for verifying the performance of transceivers, contributing to the spread of government-promoted e-navigation services and small-sized transceivers.

Periodontal status of end-stage renal disease patients undergoing dialysis and referred for intraoral evaluation prior to kidney transplant surgery (투석을 받고 있으며 신장 이식 수술 전 구강내 평가를 위해 의뢰된 말기 신장 질환 자의 치주 상태)

  • Youn-Kyung Choi;Hye-Mi Jeon;Ji-Young Joo;Hyun-Joo Kim;Eun-Young Kwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.46-54
    • /
    • 2024
  • Purpose: The purpose of this study was to compare the periodontal status of end-stage renal disease patients undergoing dialysis and referred for intraoral evaluation prior to renal transplantation surgery with those having normal kidney function. Materials and Methods: Patients who had been undergoing dialysis for end-stage renal disease and been referred to the Dental Clinic Center by the Department of Nephrology at University Hospital for intraoral evaluation prior to kidney transplantation surgery. For comparison of periodontal status, subjects without abnormalities in kidney function were matched with the patients by age and gender and selected as healthy controls. The patients' age, gender, comorbidities, type of dialysis received, and duration of dialysis were investigated by reference to their medical records, and data on their periodontal status were analyzed via the relevant periodontal records. Results: A total of 102 patients, including 51 dialyzed patients and 51 healthy control group subjects, participated in this study. In the patients with end-stage renal disease undergoing dialysis with periodontal probing depth of 5 mm or more, percentage of sites with clinical attachment level of 4 mm or more, percentage of teeth with bleeding on probing, number of missing teeth, and ratio of moderate to severe periodontitis were all significantly greater than in the healthy controls. Conclusion: The periodontal status of end-stage renal disease patients undergoing dialysis and referred for intraoral evaluation prior to kidney transplantation was worse than that of healthy controls.

Radiation Dose Reduction in Digital Mammography by Deep-Learning Algorithm Image Reconstruction: A Preliminary Study (딥러닝 알고리즘을 이용한 저선량 디지털 유방 촬영 영상의 복원: 예비 연구)

  • Su Min Ha;Hak Hee Kim;Eunhee Kang;Bo Kyoung Seo;Nami Choi;Tae Hee Kim;You Jin Ku;Jong Chul Ye
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.344-359
    • /
    • 2022
  • Purpose To develop a denoising convolutional neural network-based image processing technique and investigate its efficacy in diagnosing breast cancer using low-dose mammography imaging. Materials and Methods A total of 6 breast radiologists were included in this prospective study. All radiologists independently evaluated low-dose images for lesion detection and rated them for diagnostic quality using a qualitative scale. After application of the denoising network, the same radiologists evaluated lesion detectability and image quality. For clinical application, a consensus on lesion type and localization on preoperative mammographic examinations of breast cancer patients was reached after discussion. Thereafter, coded low-dose, reconstructed full-dose, and full-dose images were presented and assessed in a random order. Results Lesions on 40% reconstructed full-dose images were better perceived when compared with low-dose images of mastectomy specimens as a reference. In clinical application, as compared to 40% reconstructed images, higher values were given on full-dose images for resolution (p < 0.001); diagnostic quality for calcifications (p < 0.001); and for masses, asymmetry, or architectural distortion (p = 0.037). The 40% reconstructed images showed comparable values to 100% full-dose images for overall quality (p = 0.547), lesion visibility (p = 0.120), and contrast (p = 0.083), without significant differences. Conclusion Effective denoising and image reconstruction processing techniques can enable breast cancer diagnosis with substantial radiation dose reduction.

LI-RADS Treatment Response versus Modified RECIST for Diagnosing Viable Hepatocellular Carcinoma after Locoregional Therapy: A Systematic Review and Meta-Analysis of Comparative Studies (국소 치료 후 잔존 간세포암의 진단을 위한 LI-RADS 치료 반응 알고리즘과 Modified RECIST 기준 간 비교: 비교 연구를 대상으로 한 체계적 문헌고찰과 메타분석)

  • Dong Hwan Kim;Bohyun Kim;Joon-Il Choi;Soon Nam Oh;Sung Eun Rha
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.331-343
    • /
    • 2022
  • Purpose To systematically compare the performance of liver imaging reporting and data system treatment response (LR-TR) with the modified Response Evaluation Criteria in Solid Tumors (mRECIST) for diagnosing viable hepatocellular carcinoma (HCC) treated with locoregional therapy (LRT). Materials and Methods Original studies of intra-individual comparisons between the diagnostic performance of LR-TR and mRECIST using dynamic contrast-enhanced CT or MRI were searched in MEDLINE and EMBASE, up to August 25, 2021. The reference standard for tumor viability was surgical pathology. The meta-analytic pooled sensitivity and specificity of the viable category using each criterion were calculated using a bivariate random-effects model and compared using bivariate meta-regression. Results For five eligible studies (430 patients with 631 treated observations), the pooled per-lesion sensitivities and specificities were 58% (95% confidence interval [CI], 45%-70%) and 93% (95% CI, 88%-96%) for the LR-TR viable category and 56% (95% CI, 42%-69%) and 86% (95% CI, 72%-94%) for the mRECIST viable category, respectively. The LR-TR viable category provided significantly higher pooled specificity (p < 0.01) than the mRECIST but comparable pooled sensitivity (p = 0.53). Conclusion The LR-TR algorithm demonstrated better specificity than mRECIST, without a significant difference in sensitivity for the diagnosis of pathologically viable HCC after LRT.

Comparison of Computed Diffusion-Weighted Imaging b2000 and Acquired Diffusion-Weighted Imaging b2000 for Detection of Prostate Cancer (전립선암 발견을 위한 계산형 확산강조영상 b2000과 실제 획득한 b2000 영상의 비교)

  • Yeon Jung Kim;Seung Ho Kim;Tae Wook Baek;Hyungin Park;Yun-jung Lim;Hyun Kyung Jung;Joo Yeon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1059-1070
    • /
    • 2022
  • Purpose To compare the sensitivity of tumor detection and inter-observer agreement between acquired diffusion-weighted imaging (aDWI) b2000 and computed DWI (cDWI) b2000 in patients with prostate cancer (PCa). Materials and Methods Eighty-eight patients diagnosed with PCa by radical prostatectomy and having undergone pre-operative 3 Tesla-MRI, including DWI (b, 0, 100, 1000, 2000 s/mm2), were included in the study. cDWI b2000 was obtained from aDWI b0, b100, and b1000. Two independent reviewers performed a review of the aDWI b2000 and cDWI b2000 images in random order at 4-week intervals. A region of interest was drawn for the largest tumor on each dataset, and a Prostate Imaging-Reporting and Data System (PI-RADS) score based on PI-RADS v2.1 was recorded. Histologic topographic maps served as the reference standard. Results The study population's Gleason scores were 6 (n = 16), 7 (n = 53), 8 (n = 9), and 9 (n = 10). According to the reviewers, the sensitivities of cDWI b2000 and aDWI b2000 showed no significant differences (for reviewer 1, both 94% [83/88]; for reviewer 2, both 90% [79/88]; p = 1.000, respectively). The kappa values of cDWI b2000 and aDWI b2000 for the PI-RADS score were 0.422 (95% confidence interval [CI], 0.240-0.603) and 0.495 (95% CI, 0.308-0.683), respectively. Conclusion cDWI b2000 showed comparable sensitivity with aDWI b2000, in addition to sustained moderate inter-observer agreement, in the detection of PCa.