• Title/Summary/Keyword: reference calibration

Search Result 461, Processing Time 0.031 seconds

An Efficient 3D Measurement Method that Improves the Fringe Projection Profilometry (Fringe Projection Profilometry를 개선한 효율적인 3D 측정 기법)

  • Kim, Ho-Joong;Cho, Tai-Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.1973-1979
    • /
    • 2016
  • As technologies evolve, diverse 3D measurement techniques using cameras and pattern projectors have been developed continuously. In 3D measurement, high accuracy, fast speed, and easy implementation are very important factors. Recently, 3D measurement using multi-frequency fringe patterns for absolute phase computation has been widely used in the fringe projection profilometry. This paper proposes an improved method to compute the object's absolute phase using the reference plane's absolute phase and phase difference between the object and the reference plane. This method finds the object's absolute phase by adding the difference between the reference plane's wrapped phase and the object's wrapped phase to the reference plane's absolute phase already obtained in the calibration stage. Through this method, there is no need to obtain multi-frequency fringe patterns about new object for the absolute phase computation. Instead, we only need the object's phase difference relative to the reference planes's phase in the measurement stage.

Uncertainty Evaluation of Ammonia Determination in Burley Tobacco (버어리종 담배중 암모니아성 질소에 대한 불확도 측정)

  • Lee Jeong-Min;Lee Kyoung-Ku;Han Sang-Bin
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.27 no.1 s.53
    • /
    • pp.107-114
    • /
    • 2005
  • The uncertainty of measurement in quantitative analysis of ammonia by continuous-flow analysis method was evaluated following internationally accepted guidelines. The sources of uncertainty associated with the analysis of ammonia were the weighing of sample, the preparation of extracting solution, the addition of extracting solution into the sample, the reproducibility of analysis and the determination of water content in tobacco, etc. In calculating uncertainties, Type A of uncertainty was evaluated by the statistical analysis of a series of observation, and Type B by the information based on supplier's catalogue and/or certificated of calibration. It was shown that the main source of uncertainty was caused by the volume measurement of 1 mL and 2 mL, the purity of ammonia reference material in the preparation of standard solution, the reproducibility of analysis and the determination of water content of tobacco. The uncertainty in the addition of extraction solution, the sample weighing, the volume measurement of 50 mL and 100 mL, and the calibration curve of standard solution contributed relatively little to the overall uncertainty. The expanded uncertainty of ammonia determination in burley tobacco at $95\%$ level of confidence was $0.00997\%$.

An Experimental Study on the Influential Factors of Flow Measurement with Coriolis Mass Flowmeter (코리올리스 질량유량계의 유량측정에 영향을 미치는 인자에 관한 실험적 연구)

  • Lim, Ki-Won;Lee, Woan-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1699-1707
    • /
    • 2003
  • Coriolis mass flowmeter(CMF), which can measure the mass flow directly, is getting rapid attention for the industrial and custody transfer purpose. In order to study the characteristics and the applicability of CMF, it is tested with the national flow standard system. Two types of sensing tube, U-type and straight type, are employed in the test. Water, spindle oil and viscosity Standard Reference Material whose viscosities are 1, 20 and, 67 $\textrm{mm}^2$/s, respectively, are studied. It is shown that the linearity of CMF is getting deteriorated as the fluid viscosity increases, which is due to the zero drift and the relaxation time of the fluid. To test its applicability in the case of high pressured gas, it is calibrated using compressed air, It shows 1∼l.6 % deviations compared to the calibration results using water. It concludes that the fluid velocity in CMF should be lower than the sonic velocity. In addition, the effects of the vibration from the pipeline and pump on CMF as well as the long term stability are studied.

The Development of Pulverized Coal(PC) Flow-Meter using Capacitance (정전용량을 이용한 미분탄 유량계의 개발)

  • Gim, Jae-Hyeon;Lee, Yong-Sik;Hwang, Keon-Ho;Jeong, Sung-Won;Yeo, Jun-Ho;So, Ji-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.61-67
    • /
    • 2008
  • In this papar, the flow meter system for pulverized coal is developed for the pulverizer-burner system of the boiler or the blast furnace. The sensor of the system a lied the capacitance with a pair of electrode on the outer wall of the electric insulator pipe. The circuit is designed for the measurement of the granule flow density combining as a measuring electrode and a reference. In order to measure granule-flow density, the calibration curve between the weight measured from loadcell and the voltage from the circuit is created. It is verified that the flow meter system has reliability and accuracy using on-line test.

Development of a Candidate Equipment for Ozone SRP and its Uncertainty Evaluation (오존 SRP의 제작과 측정 불확도 평가)

  • 정규백;우진춘;이진홍
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.4
    • /
    • pp.313-319
    • /
    • 2001
  • The development of ozone SRP (Standard Reference Photometer) designated as a G-7 project by the Korean Ministry of Environment began 1997 and is now nearly completed. With the completion of the ozone SRP we will not only acquire a qualification to participate in the international ozone calibration system but also enhance calibration credibility of ozone similarly to that of other ambient air pollution monitors. As the ozone SRP uses highly cleaned blank air that can be distinguished from general ozone analyzer, it is possible to reduce errors associated with the determination of ozone via elongation of the absorption length as long as 1 meter In addition, gas chopping method hat been adopted to cut down interference of other substances and time drift. Furthermore, the system has also been modified to minimize the strayed ultra-violet noise along the light path. In this paper, a new method for uncertainty evaluation has been introduced, which is guided by the ISO (International Standard Organization) GUM (Guide to the Expression of Uncertainty in Measurement) through assessments of the uncertainty type B (that was impossible to estimate before) as well as the uncertainty type A (based on statistics).

  • PDF

Calibration of a Korean Weapon Systems Wargame Model (한국적 무기체계의 워게임 모델 교정에 관한 연구)

  • Jung, Kun-Ho;Yum, Bong-Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.191-198
    • /
    • 2009
  • Some of the wargame simulators currently used in the Korean Army were developed by other countries, and do not adequately reflect the Korean Peninsula terrain and weapon systems. This implies that these war game simulators need to be calibrated with respect to the input parameters for properly assessing the effectiveness of the Korean weapon systems. In this paper, AWAM, a wargame simulator, is calibrated in terms of the time-based fighting power(FP). The FP data obtained from the Korea Combat Training Center(KCTC) are used as a reference, and the differences between the AWAM and KCTC FP data are calculated at certain points in time. Then, the Taguchi robust design method is adopted using the probabilities of hitting for the K-2 rifle as controllable input parameters. Two performance characteristics are used. One is the difference between the AWAM and KCTC FP data and the other is the score derived by grouping the difference data. For each case, optimal settings of the probabilities of hitting are determined such that the mean of each characteristic is close to 0 with its dispersion being as small as possible.

A Study on the Mark Reader Using the Image Processing (영상처리를 이용한 Mark 판독 기법에 관한 연구)

  • 김승호;김범진;이용구;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.83-83
    • /
    • 2000
  • Recently, Vision system has being used all around industry. Sensor systems are used for Mark Reader, for example, optical scanning is proximity sensor system, have many disadvantages, such as, lacking user interface and difficulty to store original specimens. In contrast with this, Vision systems for Mark Reader has many advantages, including function conversion to achieve other work, high accuracy, high speed, etc. In this thesis, we have researched the development of Mark Reader by using a Vision system. The processing course of this s)'stem is consist to Image Pre-Processing such as noise reduction, edge detection, threshold processing. And then, we have carried out camera calibration to calibrate images which are acquired from camera. After searching for reference point within scanning area(60pixe1${\times}$30pixe1), we have calculated points crossing by using line equations. And then, we decide to each ROI(region of interest) which are expressed by four points. Next we have converted absolute coordinate into relative coordinate for analysis a translation component. Finally we carry out Mark Reading with images classified by six patterns. As a result of experiment which follows the algorithm has proposed, we have get error within 0.5% from total image.

  • PDF

Development of Underwater Laser Scanner with Efficient and Flexible Installation for Unmanned Underwater Vehicle (무인잠수정을 위한 효과적이고 유연한 설치 성능을 지닌 수중 레이저스캐너 개발)

  • Lee, Yeongjun;Lee, Yoongeon;Chae, Junbo;Choi, Hyun-Taek;Yeu, Tae-Kyeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.511-517
    • /
    • 2018
  • This paper proposes a vision-based underwater laser scanner with separate structures for an underwater camera and a line laser projector. Because the two devices can be adaptively placed regardless of the features of the unmanned underwater vehicle (UUV), the scanner has significant advantages in relation to its availability and flexibility. Position calibration between the underwater camera and laser projector guarantees a 3D measuring performance with high accuracy. To verify the proposed underwater laser scanner, a test-bed system was manufactured, which consisted of the laser projector, camera, Pan&Tilt, and Attitude and Heading Reference System (AHRS). A camera-laser calibration test and simple 3D reconstruction test were performed in a water tank and the experimental results are reported.

A study on the use of FT-NIR spectophotometer for dried laver quality evaluation (마른김 품질 평가를 위한 FT-NIR 분광기 활용 연구)

  • Kyoung-In, Lee;Geun-Jik, Lee;Young-Seung, Yoon
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.14 no.2
    • /
    • pp.69-75
    • /
    • 2022
  • The micro-Kjeldahl method, a common technique for analyzing crude proteins, is time-consuming and dangerous due to the employment of reagents such as sulfuric acid and sodium hydroxide. However, a Fourier transform near-infrared (FT-NIR) spectrophotometer analysis can be completed in under a minute after simple pre-processing if data has been gathered using sufficient reference material in advance. Furthermore, the use of safe reagents in this technique ensures the safety of the experimenter and the environment. In addition, a portable FT-NIR spectrophotometer enables real-time measurement at processing or distribution sites and has recently gained popularity. The standard errors of calibration and regression (r2) for the calibration result for estimating the crude protein content of dried laver were 0.9775 and 1.2526, respectively. The standard error of prediction was 1.1814, and the r2 was 0.9303 in the validation results, which was a good level. In the present study, a method for predicting the crude protein content of dried laver using an FT-NIR spectrophotometer in the range of 29%-40% crude protein content has been reported.

NEAR INFRARED TRANSFLECTANCE SPECTROSCOPY (NIRS) IN PHYTOCHEMISTRY

  • Huck, C.W.;W.Guggenbichler;Bonn, G.K.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3114-3114
    • /
    • 2001
  • During the last years phytochemistry and phytopharmaceutical applications have developed rapidly and so there exists a high demand for faster and more efficient analysis techniques. Therefore we have established a near infrared transflectance spectroscopy (NIRS) method that allows a qualitative and quantitative determination of new polyphenolic pharmacological active leading compounds within a few seconds. As the NIR spectrometer has to be calibrated the compound of interest has at first to be characterized by using one or other a combination of chromatographic or electrophoretic separation techniques such as thin layer chromatography (TLC), high performance liquid chromatography (HPLC), capillary electrophoresis (CE), gas chromatography (GC) and capillary electrochromatography (CEC). Both structural elucidation and quantitative analysis of the phenolic compound is possible by direct coupling of the mentioned separation methods with a mass spectrometer (GC-MS, LC-MS/MS, CE-MS, CEC-MS) and a NMR spectrometer (LC-NMR). Furthermore the compound has to be isolated (NPLC, MPLC, prep. TLC, prep. HPLC) and its structure elucidated by spectroscopic techniques (UV, IR, HR-MS, NMR) and chemical synthesis. After that HPLC can be used to provide the reference data for the calibration step of the near infrared spectrometer. The NIRS calibration step is time consuming, which is compensated by short analysis times. After validation of the established NIRS method it is possible to determine the polyphenolic compound within seconds which allows to raise the efficiency in quality control and to reduce costs especially in the phytopharmaceutical industry.

  • PDF