• Title/Summary/Keyword: redundancy analysis

Search Result 382, Processing Time 0.043 seconds

Switching-Level Operation Analysis of MMC-based Back-to-Back Converter for HVDC Application (HVDC 적용을 위한 MMC 기반 Back-to-Back 컨버터의 스위칭레벨 동작분석)

  • Hong, Jung-Won;Jeong, Jong-Kyou;Yoo, Seong-Hwan;Choi, Jong-Yun;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1240-1248
    • /
    • 2013
  • This paper describes a switching-level operation analysis of BTB(Back-To-Back) converter for HVDC(high voltage DC) application based on MMC(modular multi-level converter). A switching-level operation analysis for BTB converter is very important to understand the converter operation in detail and check the voltage and current transients in each components. However, the development of switching-level simulation model for the actual size BTB Converter is very difficult because the MMC normally has more than 150 sub-modules for each arm. So, a switching level simulation model for the 11-level MMC-based BTB converter was developed with PSCAD/EMTDC software, which has 12 sub-modules for the positive arm and another 12 sub-modules for the negative arm. The DC-voltage balance algorithm, the circulating-current reduction algorithm, the harmonic reduction algorithm, and the redundancy operation algorithm were included in this simulation model. The developed simulation model can be utilized to analyze the MMC-based BTB converter for HVDC application in switching level and to develop the protection scheme for the MMC-based BTB converter for HVDC application.

Reliability Analysis of the Communications & Broadcasting Satellite Transponder and its Optimal Design (통신방송위성 중계기의 신뢰도 분석 및 최적 설계)

  • Kim, Young-Suk;Chang, Young-Keun;Jeong, Chul-Oh
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.8
    • /
    • pp.94-102
    • /
    • 2002
  • Since it would be almost impossible to recover and/or repair the satellite in space once it has been launched, a detailed analysis and design, manufacturing using the high quality workmanship, and qualification and acceptance tests in space-simulation environments are necessary for all satellite components prior to launch. Even though these efforts arc made, the failure can still occur. Therefore, redundancy should be considered in the satellite design for continuous operations in preparation for part or equipment failure. In this paper, the reliability analysis of the transponder, which is a payload of Communications & Broadcasting Satellite being developed by ETRI, was performed and compared for various design cases with different redundancies to find the optimal design. The optimal design has been finalized by investigating how the redundant components are composed from the viewpoint of technical performance measures, such as reliability, cost, schedule, and mass.

Availability Analysis of SRAM-Based FPGAs under the protection of SEM Controller (SEM Controller에 의해 보호되는 SRAM 기반 FPGA의 가용성 분석)

  • Ryu, Sang-Moon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.3
    • /
    • pp.601-606
    • /
    • 2017
  • SRAM-based FPGAs mainly used to develop and implement high-performance circuits have SRAM-type configuration memory. Soft errors in memory devices are the main threat from a reliability point of view. Soft errors occurring in the configuration memory of FPGAs cause FPGAs to malfunction. SEM(Soft Error Mitigation) Controllers offered by Xilinx can mitigate the influence of soft errors in configuration memory. SEM Controllers use ECC(Error Correction Code) and CRC(Cyclic Redundancy Code) which are placed around the configuration memory to detect and correct the errors. The correction is done through a partial reconfiguration process. This paper presents the availability analysis of SRAM-based FPGAs against soft errors under the protection of SEM Controllers. Availability functions were derived and compared according to the correction capability of SEM Controllers of several different families of FPGAs. The result may help select an SRAM-based FPGA part and estimate the availability of FPGAs running in an environment where soft errors occur.

Life-cycle estimation of HVDC full-bridge sub-module considering operational condition and redundancy (HVDC 풀-브리지 서브모듈의 동작 조건과 여유율을 고려한 수명예측)

  • Kang, Feel-soon;Song, Sung-Geun
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1208-1217
    • /
    • 2019
  • The life-cycle prediction of the sub-module which is the unit system of MMC is very important from the viewpoint of maintenance and economic feasibility of HVDC system. However, the life-cycle prediction that considers only the type, number and combination of parts is a generalized result that does not take into account the operating condition of the sub-module, and may significantly differ from the life-cycle of the actual one. Therefore, we design a fault tree for the purpose of reflecting the operation characteristics of the full-bridge sub-module and apply the MIL-HDBK-217F to the failure rate of the basic event to predict the life-cycle of the full-bridge sub-module. It compares the life-cycle expectancy of the conventional failure rate analysis with the proposed fault-tree analysis and compares the lifetime according to whether the redundancy of the full-bridge sub-module is considered.

Evaluation of the Strength Required in Current Seismic Design Code (현행 내진설계 규준의 수평강도 요구에 대한 평가)

  • 한상환;오영훈;이리형
    • Computational Structural Engineering
    • /
    • v.10 no.4
    • /
    • pp.281-290
    • /
    • 1997
  • Current seismic design code is based on the assumption that the designed structures would be behaved inelastically during a severe earthquake ground motion. For this reason, seismic design forces calculated by seismic codes are much lower than the forces generated by design earthquakes which makes structures responding elastically. Present procedures for calculating seismic design forces are based on the use of elastic spectra reduced by a strength reduction factors known as "response modificaion factor". Because these factors were determined empirically, it is difficult to know how much inelastic behaviors of the structures exhibit. In this study, lateral strength required to maintain target ductility ratio was first calculated from nonlinear dynamic analysis of the single degree of freedom system. At the following step, base shear foeces specified in seismic design code compare with above results. If the base shear force required to maintain target ductility ratio was higher than the code specified one, the lack of required strength should be filled by overstrength and/or redundancy. Therefore, overstrength of moment resisting frame structure will be estimated from the results of push-over analysis.

  • PDF

Soil factors determining the distribution of Phragmites australis and Phacelurus latifolius in upper tidal zone

  • Nam, Bo Eun;Hong, Mun Gi;Park, Hyun Jun;Kim, Jae Geun
    • Journal of Ecology and Environment
    • /
    • v.42 no.4
    • /
    • pp.205-210
    • /
    • 2018
  • To assess the environmental factors determining the zonation between Phacelurus latifolius and Phragmites australis, vegetation survey and soil analysis were performed at a tidal marsh. The vegetation of the tidal marsh was classified into P. latifolius and Suaeda japonica dominated quadrats, P. latifolius and P. australis dominated quadrats, P. australis dominated quadrats, and P. australis and other land plants dominated quadrats. The density of P. latifolius ($83.7{\pm}5.5\;shoots\;m^{-2}$) was higher than that of P. australis ($79.3{\pm}12.1\;shoots\;m^{-2}$) in each dominated quadrat but height of two species were similar. Soil environmental characteristics of P. latifolius dominated quadrats appeared to be affected by tide based on higher soil electric conductivity ($EC_{PL}=1530{\pm}152{\mu}Scm^{-1}$ ; $EC_{PA+PL}=689{\pm}578{\mu}Scm^{-1}$ ; $EC_{PA}=689{\pm}578{\mu}Scm^{-1$) and lower pH ($pH_{PL}=5.96{\pm}0.16$ ; $pH_{PA+PL}=6.28{\pm}0.31$ ; $pH_{PA}=6.38{\pm}0.22$). In redundancy analysis, environmental characteristics of P. latifolius dominated quadrats and P. australis dominated quadrats were clearly separated and those of P. latifolius and P. australis co-dominated quadrats were similar to P. australis dominated quadrats. From our investigation, P. latifolius showed relatively high competitiveness when compared to P. australis in lower tidal zone rather than upper tidal zone. Zonation of P. latifolius and P. australis seems to be a transitional zone between halophytes and land plant species.

Effects of Environmental Factors on the Seasonal Variations of Zooplankton Communities in the Semi-enclosed Yeoja Bay, Korea (반폐쇄적 여자만 동물플랑크톤 군집의 계절변화에 따른 환경요인의 영향)

  • Seong Yong Moon;Heeyong Kim;Mi Hee Lee;Jin Ho Jung;Se Ra Yoo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.1
    • /
    • pp.54-65
    • /
    • 2023
  • Effect of environmental factors on the seasonal variations of zooplankton communities was investigated in the semi-closed Yeoja Bay, Korea from February, April to August, and November 2021. Out of a total 49 species of zooplankton were collected with a predominant of neritic copepods (mainly Paracalanus orientalis, Acartia omorii, Acartia ohtsukai, Centropages abdominalis, Ditrichocorycaeus affinis, and Oithona sp.), accounting for 58.9% of the total abundance of zooplankton. The diversity indices indicated a relatively highest in July, suggesting that diversity is influenced by seasonal temperature, N. scintillans, and neritic copepods species. A cluster analysis with non-metric multidimensional scaling revealed four groups of zooplankton communities. The February sample clustered into Group A, having the lowest mean total abundance and species diversity of zooplankton, consisting mainly of N. scintillans located the whole region. Cluster Group B from the spring season (April to May) and contained the species diversity with some neritic copepods. Cluster Group C from the summer season (June to August) mainly comprised P. orientalis, A. ohtsukai, Oithona sp., and hydromedusae. Cluster Group D from the autumn season (November) mainly comprised P. orientalis, Temora discaudata. Redundancy analysis indicated that abundance is positively correlated with temperature, salinity, and pico chlorophyll-a concentrations. This study showed that planktonic larvae (such as branchyura larvae) and some copepods (including A. omorii, A. ohtsukai, C. sinicus, and C. abdominalis) were significantly vulnerable to zooplankton community of temperature, salinity, and pico chlorophyll-a concentrations.

A New Method of Lossless Universal Data Compression (새로운 무손실 유니버셜 데이터 압축 기법)

  • Kim, Sung-Soo;Lee, Hae-Kee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.285-290
    • /
    • 2009
  • In this paper, we propose a new algorithm that improves the lossless data compression rate. The proposed algorithm lessens the redundancy and improves the compression rate evolutionarily around 40 up to 80 percentile depending on the characteristics of binary images used for compression. In order to demonstrate the superiority of the proposed method, the comparison between the proposed method and the LZ78 (LZ77) is demonstrated through experimental results theoretical analysis.

The Study on the Embodiment and Analysis of the Redundancy applied to SCADA (스카다시스템에 적용된 이중화기술의 구현과 분석에 관한 연구)

  • Heo, Sun-Gu;Jung, Lee-Sik;Lim, Jae-Il
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2341-2343
    • /
    • 2004
  • 전국의 다목적댐 발전소을 본사에서 원격 감시.제어를 행함에 있어 네트워크.감시제어시스템의 연결장애시 결정적인 데이터의 공백시간을 최소화하기 위해 적용된 이중화기술을 소프트웨어/하드웨어적으로 분석하여 SCADA 시스템의 신뢰도 향상에 목적을 두고자 한다.

  • PDF

Fault-tree Analysis of Cascaded H-bridge Multilevel Inverter (Cascaded H-bridge 멀티레벨인버터의 고장나무 분석)

  • Kang, Feel-soon
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.387-388
    • /
    • 2017
  • Cascaded H-bridge 멀리레벨인버터는 출력전압 레벨 수를 증가시켜 고전압 응용이 가능하도록 하는 전력변환장치로 모듈화 특성이 우수하여 그 활용 범위를 넓혀가고 있다. 출력 전압레벨 수를 증가시켜 보다 정현파에 가까운 양질의 출력전압을 생성하기 위해서는 스위칭 소자와 입력 전압원 개수의 증가로 인해 회로구조와 제어방법이 복잡해지는 문제가 발생한다. 하지만 스위칭 여유율(Redundancy)에 따른 대체 스위칭 패턴의 적용으로 전체 시스템의 신뢰성을 개선시킬 수도 있다. 본 논문에서는 고장나무 분석을 통해 Cascaded H-bridge 멀티레벨 인버터의 위험도를 계산하고 스위칭 여유율과의 관련성을 분석하고자 한다.

  • PDF