• 제목/요약/키워드: reduction plan

Search Result 965, Processing Time 1.274 seconds

A Study on a Plan to Efficiently Construct an Expressway with Low Traffic Volume (교통량이 적은 고속도로의 효율적인 건설 방안 연구)

  • Kim, Jinsub;Hong, Sukkee;Park, Kuiyoung;Park, Namsik
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.11-24
    • /
    • 2016
  • OBJECTIVES : This study aims to review a plan to reduce the shoulder width of a deformed round-trip two-lane highway with low traffic volume. METHODS : Installation of a passing lane on a round-trip two-lane (one-way one-lane) highway, and reduction of a shoulder for a round-trip four-lane highway. RESULTS : It is necessary to establish a design criterion for various highways, because the plan to reduce the lane or shoulder width of a highway with low traffic volume was analyzed to have an economic efficiency of 6.8~7.0%. CONCLUSIONS : It is necessary to seek for a plan to establish a national trunk net early by efficiently using the limited financial resources to cope with the traffic demand elastically.

A Study on the Interior Noise Reduction of EMU by Contribution Analysis (기여도 분석에 의한 전기동차 실내소음 저감대책 연구)

  • 문경호;김재철;유원희
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.218-225
    • /
    • 1999
  • Speed-up and mass reduction of EMU(Electrical multiple unit) causes increase of interior noise. One of the best ways to reduce the interior noise is to identify noise sources. In this study, we evaluated interior noise by contribution analysis. This method is to predict the interior noise contribution of carbody by using transfer function between acceleration and sound pressure. The plan of the interior noise reduction based on the test results was also presented.

  • PDF

Research on eco-friendly construction management plan for construction site through waste fiber resource recycling technology (폐섬유 자원재활용 기술을 통한 건설현장 친환경 시공관리 방안에 관한 연구)

  • Kim, Dae-Geon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.45-46
    • /
    • 2022
  • Recently, it is necessary to establish an eco-friendly construction system through recycling of waste material management at construction sites. This is required to reflect the times that require a carbon reduction system in construction as part of domestic and overseas carbon dioxide reduction. Therefore, we intend to establish eco-friendly construction management as part of resource recycling and carbon reduction through recycling technology for waste fibers generated at construction sites.

  • PDF

A Study on the Improvement Plans of Energy Performance in University Building through the Analysis of Energy (에너지 해석을 통한 대학건물의 에너지 성능개선 방안에 관한 연구)

  • Jung, Jae-Woong;Kim, Dong-Woo;Seok, Ho-Tae;Yang, Jeong-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.50-60
    • /
    • 2010
  • Today, the amount of energy consumption in the university campuses is huge. The effort for the energy consumption reduction in university campuses is certainly needed by the following reason; first, contribution to the greenhouse gas discharge reduction demand. Second, energy cost reduction in university campus. Third, contribution to the improvement of the social awareness as the maximum higher educational institutions. The energy consumption analysis of current situation has to be executed for the energy consumption reduction in university campus. The energy reduction possibility in which it exists in university campuses can be understood through the energy consumption analysis. And the application is possible as fundamental data of the policy establishment for the effective energy reduction in university campuses. Especially, the best way to reduce the energy consumption in university campuses that is the energy consumption reduction of buildings. Accordingly, this study derived the plans for improving the performance of energy in the university building by analyzing case study, so this study analyzed the performance of energy for the university building through VE, a program for the analysis of building energy. Based on this result, this study classified the plans improving the efficiency of energy in university building into the plan for passive control and active control respectively, and suggested some concrete plans, and finally evaluated the performance of decreasing energy consumption for each plan.

Evaluation of the Development and Reduction Scheme under Implementation Plan of Total Maximum Daily Loads in the Jinwi Watershed (진위천 수계의 수질오염총량제 시행에 따른 지역개발과 삭감계획 평가)

  • Han, Mideok;Ahn, Ki Hong;Ryu, Jichul;Son, Jeeyong;Park, Bae Kyung;Kim, Young Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.451-459
    • /
    • 2014
  • The development and reduction scheme under implementation plan of TMDLs were performed in the Jinwi watershed including 8 cities (Gunpo, Yongin, Suwon, Anseong, Osan, Uiwang, Pyeongtaek and Hwaseong) since 2012. Progress of the annual development schemes was faster than the reduction schemes in most of the cities during the planning period. Main load reduction methods included establishment and enlargement of sewage treatment plants, resources of livestock excretions, and introduction of best management practices of non-point source pollution. Especially, reduction load using recycling and composting of livestock excretions comprised 34.1% of all reduction load. It is necessary to implement methodical development and reduction scheme for making of successful performance of TMDLs and water quality improvement in the Jinwi watershed.

Bolus Effect to Reduce Skin Dose of the Contralateral Breast During Breast Cancer Radiation Therapy (유방암 방사선치료 시 반대편 유방의 피부선량 감소를 위한 볼루스 효과)

  • Won, Young Jin;Kim, Jong Won;Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.289-295
    • /
    • 2017
  • The aim of this study was to evaluate the dose comparison using Radon phantom with 5 mm and 10 mm tissue equivalent materials, FIF, Wedge(15, 30 angle) and IMRT, to reduce the skin dose of the contralateral breast during breast cancer radiation therapy(Total dose: 50.4Gy). The dose was measured for each treatment plan by attaching to the 8 point of the contralateral breast of the treated region using a optical-stimulated luminance dosimeter(OSLD) as a comparative dose evaluation method. Of the OSLD used in the study, 10 were used with reproducibility within 3%. As a result, the average reduction rates of 5 mm and 10 mm in the FIF treatment plan were 37.23 cGy and 41.77 cGy, respectively, and the average reduction rates in the treatment plan using Wedge $15^{\circ}$ were 70.69 cGy and 87.57 cGy, respectively. The IMRT showed a reduction of 67.37 cGy and 83.17 cGy, respectively. The results of using bolus showed that as the thickness of the bolus increased in all treatments, the dose reduction increased. We concluded that mastectomy as well as general radiotherapy for breast cancer would be very effective for patients who are more likely to be exposed to scattered radiation due to a more demanding or complex treatment plan.

A Study on the Improvement of the Safety Management Plan under the Construction Technology Promotion Act by Field Survey (현장실태조사를 통한 건설기술진흥법 상 안전관리계획서의 개선방향에 대한 연구)

  • Yoon, Young Geun;Lee, Myeong-Gu;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.30-37
    • /
    • 2018
  • Although the safety management plan review system according to the Construction Technology Promotion Act for securing the safety of the construction work is a fundamental system essential for the prevention of the construction industry disaster, the necessity of its improvement has been raised because it often fails to meet the original purpose. In this study, through the analysis of the effect of the safety management plan and the problems of the operation, we suggest ways to improve it in view of the construction accident reduction and conducted surveys on the construction site through the questionnaires of the client, construction company, and construction business technology manager. In order to improve the effectiveness of this system as a result of the study, it is necessary to distribute the guidelines for the preparation of the safety management plan, manuals, etc., to simplify the contents of the safety management plan, also the step-by-step approval of the safety plan can be a solution. For this, it is necessary to revise the policy through consultation with the Ministry of Land, Transport and Maritime Affairs and related experts.

A Study on the Reset of Examination Criteria for Energy Use Plan through Consultation Case Analysis (협의 사례 분석을 통한 에너지사용계획 검토기준 재설정 연구)

  • Suh, Kwang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.59-69
    • /
    • 2013
  • The Consultation about Energy Use Plan is prescribed by the Energy Use Rationalization Act. In order to reset Examination Criteria for Energy Use Plan, consultation case analysis from 2001 to 2010 were carried out and National Energy Master Plan was reviewed. This study proposes that Examination Criteria for Energy Use Plan be should divided into Urban & Tourism complex development project and Industrial complex development project for the prevention of civil complain. Also predicts that effect of energy savings calculated by Reset Examination Criteria on $1^{ST}$ energy demand BAU at 2030 is 2.2%, effect of new & renewable energy utilization at 2030 is 3% and the rate of $CO_2$ reduction to greenhouse gas emission BAU at 2020 is 1.1%.

A Study on the Planning Indicator for Carbon Neutral Green City (탄소중립 녹색도시 구현을 위한 계획지표 설정에 관한 연구)

  • Kim, You-Min;Lee, Joo Hyung
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.131-139
    • /
    • 2013
  • The aim of this dissertation is establishing internal indicator list for achieving policy goal of Carbon Neutrality Green City. First of all, it started to construct the basic system of planning indicator based on through comprehension of current studies such as advanced researches, government guidelines and green building certifications. And then it was set up final indicator list through inspecting FGI (Focus Group Interview), Verification of suitability, and Analysis of importance). As a result of this research, the planning indicator divided three steps and there were classified four fields in the top-level; Green Land and Ecology, Green Energy, Green Resource and Transportation, Green Living and Institution. According to the data, it deducted four items (ratio of green land, site plan, heat island and management of climate, base of nature ecology) and twelve index in the field of green land and ecology, three item(energy conservation and self-supporting, energy efficiency, new regeneration energy) and twelve index in the field of green energy and regeneration, five items(water resources utilize and circulation, other resource reduction and circulation, public transportation, green transportation plan) and fifteen index. Totally, Planning Indicators of forty nine were deducted. Therefore, there was the result of importance analysis that the indicators of plan and maintain management as the side of space for carbon neutrality were more appreciated than carbon reduction of individual building.