• Title/Summary/Keyword: reduction effect

Search Result 11,248, Processing Time 0.037 seconds

Analysis on the Effect of Infiltration Collector Well Installation on the Water Control (침투통의 설치에 따른 치수효과 분석)

  • Shim, Jae-hyun;Lee, Cheol-kyu;Lee, Jong-kook;Kim, Jin-young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.298-302
    • /
    • 2004
  • In this study, the runoff reduction effect was analyzed quantitatively focusing on the infiltration collector well located in the test area. On the basis of the analysis of the data obtained by examining the real-time measurement field data, the runoff reduction was examined through the measured rainfall of the year 2003 by applying the analysis result, with the PCSWMM model to the Kiheung-Gugal residential area, which is selected as the test basin. According to the analysis, it is revealed that an infiltration collector well can reduce up to $65\~98\%$ of runoffs, compared to a conventional one. For measured rainfalls, an infiltration collector well was able to reduce up to $15\~23\%$ of runoffs and $3\~25\%$ of peak runoffs. These results show that the effects of infiltration collector wells might vary with rainfall intensity and its duration. However, the infiltration collector well was confirmed as the one of the alternatives of runoff reduction facilities in urbanized catchment.

  • PDF

A negative stiffness inerter system (NSIS) for earthquake protection purposes

  • Zhao, Zhipeng;Chen, Qingjun;Zhang, Ruifu;Jiang, Yiyao;Pan, Chao
    • Smart Structures and Systems
    • /
    • v.26 no.4
    • /
    • pp.481-493
    • /
    • 2020
  • The negative stiffness spring and inerter are both characterized by the negative stiffness effect in the force-displacement relationship, potentially yielding an amplifying mechanism for dashpot deformation by being incorporated with a series tuning spring. However, resisting forces of the two mechanical elements are dominant in different frequency domains, thus leading to necessary complementarity in terms of vibration control and the amplifying benefit. Inspired by this, this study proposes a Negative Stiffness Inerter System (NSIS) as an earthquake protection system and developed analytical design formulae by fully utilizing its advantageous features. The NSIS is composed of a sub-configuration of a negative stiffness spring and an inerter in parallel, connected to a tuning spring in series. First, closed-form displacement responses are derived for the NSIS structure, and a stability analysis is conducted to limit the feasible domains of NSIS parameters. Then, the dual advantageous features of displacement reduction and the dashpot deformation amplification effect are revealed and clarified in a parametric analysis, stimulating the establishment of a displacement-based optimal design framework, correspondingly yielding the design formulae in analytical form. Finally, a series of examples are illustrated to validate the derived formulae. In this study, it is confirmed that the synergistic incorporation of the negative stiffness spring and the inerter has significant energy dissipation efficiency in a wide frequency band and an enhanced control effect in terms of the displacement and shear force responses. The developed displacement-based design strategy is suitable to utilize the dual benefits of the NSIS, which can be accurately implemented by the analytical design formulae to satisfy the target vibration control with increased energy dissipation efficiency.

Analysing the Effect of Residual Chlorine Equalization for Water Quality Improvement in Water Distribution System (공급과정 수질개선을 위한 잔류염소 균등화 효과분석)

  • Choi, Taeho;Lee, Doojin;Bae, Cheolho;Moon, Jiyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.587-596
    • /
    • 2016
  • This study attempts to draw factors for an analysis of the operation effect of a rechlorination facility and autodrain equipment for residual chlorine equalization by installing and operating a rechlorination facility and autodrain equipment in P City and analyzing the practical evaluation method and operation effect. For this purpose, this study selected three indicators for an analysis of the effectiveness of residual chlorine equalization and conducted a comparative analysis before and after the implementation of the residual chlorine equalization. As a result of estimation, (1) the reduction of the residual chlorine concentration range from a water treatment plant to the pipe end was 16.0%; (2) the total reduction of chlorination input was 18.0%; and (3) the reduction of the generation of disinfection by-products was 19.5%. In addition, this achieved enough residual chlorine equalization in the supply process and shows that it could successfully achieve the economic feasibility of investment in equipment and the reduction of the generation of disinfection by-products. Like this, it is judged that the three indicators suggested in this study will be used sufficiently as indicators of an analysis of the effectiveness of residual chlorine equalization according to the operations of the rechlorination facility and autodrain equipment.

Effects of Reclaimed Wastewater Irrigation on Paddy Rice Yields and Fertilizer Reduction using the DSSAT Model (하수처리수의 농업용수 재이용에 따른 논벼 수확량 모의)

  • Jeong, Han-Seok;Seong, Choung-Hyun;Jang, Tae-Il;Jung, Ki-Woong;Kang, Moon-Seong;Park, Seung-Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.4
    • /
    • pp.67-74
    • /
    • 2011
  • The objectives of this study were to assess the rice yields and evaluate fertilizer reduction effect of reclaimed wastewater irrigation in paddy fields using the Decision Support System for Agrotechnology Transfer (DSSAT) v4.5 model. The experimental plots were designed, which was located near the Suwon wastewater treatment plant in Gyeonggi-do, Korea. The rice yield, irrigation amount, irrigation water quality and soil data were monitored and collected between 2006 and 2009. The DSSAT model was calibrated and validated with observed data. The methods that were used to evaluate this model were the root mean square error (RMSE), normalized root mean square error (nRMSE), and index of agreement (d). The values of RMSE, nRMSE, and d ranged from 145 to $789\;kg\;ha^{-1}$, 3.0 to 13.3 %, and 0.90 to 0.95 for the calibration period, respectively and represented from 91 to $538\;kg\;ha^{-1}$, 2.0 to 10.4 %, 0.94 to 0.98 for the validation period, respectively. Overall, this model showed good agreement with observed data of rice yields irrigated with reclaimed wastewater. The fertilizer reduction effect in paddy field of reclaimed wastewater irrigation was assessed about 60 % in 2008 and 40 % in 2009.

The Effects of the Level of Use of LIS by Functions and the Linkage of Logistics Activities on the Logistics Performance (통합물류정보시스템의 활용이 물류성과에 미치는 영향에 관한 연구)

  • Shim, Kyu-Yeol;Lee, Hyun-Ki;Kim, Woo-Hyun
    • Journal of Global Scholars of Marketing Science
    • /
    • v.8
    • /
    • pp.375-402
    • /
    • 2001
  • While the national economy has rapidly grown, both insufficience in indirect capital facilities of society and attempt to avoid having a logistical job as one of the so-called dirty, difficult and dangerous jobs have resulted in the leak of labor in the logistical industry. First of all, it was shown that the functional utilization level of the logistical information system had a partial effect on the logistical performance, that the reduction of logistical costs was influenced by the information system of connecting and supporting functions, and that the improvement of customer service was significantly influenced by only the supporting-function system. Second, the logistical performance was partially influenced by the linkage between logistical activities, only the customer linkage had a significant effect on the reduction of logistical costs, and the improvement of customer service was influenced by the intra-company linkage. Third, in verifying a hypothesis that the logistical information system's functional utilization level and organizational structure would interact with each other and have an effect on the logistical performance, it was shown that based on their mutual interaction at a normalized level this center's functional information system had a significant effect on the reduction of logistical costs. Fourth, in testing a hypothesis that both the linkage between logistical activities and logistical organization structure would interact with each other and would have an effect on the logistical performance, it was shown that their interaction at a normalized level was significant concerning only the reduction of logistical costs, while there was I10 its significance in the customer service. In proving a hypothesis that the linkage between logistical activities and logistical strategy patterns would interact with each other and would have an effect on the logistical performance, it was shown in a differentiated, aggressive investment one among variously patterned logistical strategies that the customer linkage had a significant effect on the reduction of logistical costs, and in the improvement of customer service that the supplier linkage had a remarkable impact. It also was shown that in case of the cost reduction and offensive control strategy, the customer linkage had a remarkable effect, and th at in the improvement of customer service the intra-company and customer linkage had a significant effect. In the marketing and customer service strategy, finally, there was no any significant influence while the customer linkage had a significant impact in the improvement of customer service. Accordingly, whether or not individual companies utilize the logistical information system's functional utilization levels well will have an effect on their logistical performance, and how their supply chain management is well-linked will affect their logistical performance.

  • PDF

Air Temperature Modification of an Urban Neighborhood Park in Summer - Hyowon Park, Suwon-si, Gyeonggi-do- (여름철 도시근린공원의 기온저감 효과 - 경기도 수원시 효원공원 -)

  • Park, Sookuk;Jo, Sangman;Hyun, Cheolji;Kong, Hak-Yang;Kim, Seunghyun;Shin, Youngkyu
    • Journal of Environmental Science International
    • /
    • v.26 no.9
    • /
    • pp.1057-1072
    • /
    • 2017
  • In order to investigate the effect of air temperature reduction on an urban neighborhood park, air temperature data from five inside locations (forest, pine tree, lawn, brick and pergola) depending on surface types and three outside locations (Suwon, Maetan and Kwonsun) depending on urban forms were collected during the summer 2016 and compared. The forest location had the lowest mean air temperature amongst all locations sampled, though the mean difference between this and the other four locations in the park was relatively small ($0.2-0.5^{\circ}C$). In the daytime, the greatest mean difference between the forest location and the two locations exposed to direct beam solar radiation (brick and lawn) was $0.5-0.8^{\circ}C$ (Max. $1.6-2.1^{\circ}C$). In the nighttime, the mean difference between the forest location and the other four locations in the park was small, though differences between the forest location and locations with grass cover (pine tree and lawn) reached a maximum of $0.9-1.7^{\circ}C$. Comparing air temperature between sunny and shaded locations, the shaded locations showed a maximum of $1.5^{\circ}C$ lower temperature in the daytime and $0.7^{\circ}C$ higher in the nighttime. Comparing the air temperature of the forest location with those of the residential (Kwonsun) and apartment (Maetan) locations, the mean air temperature difference was $0.8-1.0^{\circ}C$, higher than those measured between the forest location and the other park locations. The temperatures measured in the forest location were mean $0.9-1.3^{\circ}C$ (Max. $2.0-3.9^{\circ}C$) lower in the daytime than for the residential and apartment locations and mean $0.4-1.0^{\circ}C$ (Max. $1.3-3.1^{\circ}C$) lower in the nighttime. During the hottest period of each month, the difference was greater than the mean monthly differences, with temperatures in the residential and apartment locations mean $1.0-1.6^{\circ}C$ higher than those measured in the forest location. The effect of air temperature reduction on sampling locations within the park and a relatively high thermal environment on the urban sampling locations was clearly evident in the daytime, and the shading effect of trees in the forest location must be most effective. In the nighttime, areas with a high sky view factor and surface types with high evapotranspiration potential (e.g. grass) showed the maximum air temperature reduction. In the urban areas outside the park, the low-rise building area, with a high sky view factor, showed high air temperature due to the effect of solar (shortwave) radiation during the daytime, while in the nighttime the area with high-rise buildings, and hence a low sky view factor, showed high air temperature due to the effect of terrestrial (longwave) radiation emitted by surrounding high-rise building surfaces. The effect of air temperature reduction on the park with a high thermal environment in the city was clearly evident in the daytime, and the shading effect of trees in the forest location must be most effective. In the nighttime, areas with high sky view factor and surface types (e.g., grass) with evapotranspiration effect showed maximum air temperature reduction. In the urban areas outside the park, the high sky view factor area (low-rise building area) showed high air temperature due to the effect of solar (shortwave) radiation during the daytime, but in the nighttime the low sky view factor area (high-rise building area) showed high air temperature due to the effect of terrestrial (longwave) radiation emitted surrounding high-rise building surfaces.

Hydrogen Reduction Behavior and Microstructure Characteristics of Ball-milled CuO-Co3O4 Powder Mixtures (볼 밀링한 CuO-Co3O4 혼합분말의 수소환원 거동과 미세조직 특성)

  • Han, Ju-Yeon;Lee, Gyuhwi;Kang, Hyunji;Oh, Sung-Tag
    • Journal of Powder Materials
    • /
    • v.26 no.5
    • /
    • pp.410-414
    • /
    • 2019
  • The hydrogen reduction behavior of the $CuO-SCo_3O_4$ powder mixture for the synthesis of the homogeneous Cu-15at%Co composite powder has been investigated. The composite powder is prepared by ball milling the oxide powders, followed by a hydrogen reduction process. The reduction behavior of the ball-milled powder mixture is analyzed by X-ray diffraction (XRD) and temperature-programmed reduction at different heating rates in an Ar-10%H2 atmosphere. The scanning electron microscopy and XRD results reveal that the hydrogen-reduced powder mixture is composed of fine agglomerates of nanosized Cu and Co particles. The hydrogen reduction kinetics is studied by determining the degree of peak shift as a function of the heating rate. The activation energies for the reduction of the oxide powders estimated from the slopes of the Kissinger plots are 58.1 kJ/mol and 65.8 kJ/mol, depending on the reduction reaction: CuO to Cu and $SCo_3O_4$ to Co, respectively. The measured temperature and activation energy for the reduction of $SCo_3O_4$ are explained on the basis of the effect of pre-reduced Cu particles.

Prediction of Potential $CO_2$ Reduction through Ground Transportation Modal Shift with Fu7el Type and Scenarios (연료원별 온실가스배출량을 고려한 육상교통수단에서의 Modal Shift 효과)

  • Kim, Cho-Young;Lee, Cheul-Kyu;Kim, Yong-Ki
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.521-527
    • /
    • 2011
  • Korea announced GHG reduction goal, 30% reduction compare with 2020 BAU and reduction target for each industry sector is planning. Transportation sector also trying to make effective technical and political counterplan of allocated GHG reduction target such as material lightening, energy efficiency improvement and Modal shift technology and so on. Modal Shift is shifting low energy efficiency vehicle to high energy efficiency vehicle which is economically meaningful under current market conditions. We can get not only energy efficiency improvement but also GHG reduction effect through modal shift. Modal Shift is effectively applying and studied in logistics field in Europe and Japan and one of the Indian companies has been registered CDM project activity involving modal shift from roadways to railways for finished goods. In this study, the scenarios are developed with detail modal shift ratio and fuel type base on state of road and rail use and GHG emission factor for each fuel type from MLTM. This result can be used as basic information to improve policies and promote increasing use of train which is more environment friendly transportation vehicle.

  • PDF

Polarographic Behavior of Azo Series Organic Compounds (Ⅰ). Reduction of 4-(2-Pyridylazo)resorcinol in Acetonitrile (Azo계 유기화합물의 폴라로그래프법적 거동 (제1보). 아세토니트릴 중에서 4-(2-Pyridylazo) resorcinol의 환원)

  • Heung Lark Lee;Zun Ung Bae
    • Journal of the Korean Chemical Society
    • /
    • v.26 no.6
    • /
    • pp.389-395
    • /
    • 1982
  • The polarographic behavior of 4-(2-pyridylazo)-resorcinol(PAR) in acetonitrile solution was studied. In order to investigate the type of reduction current at every reduction step, dependence of limiting current on the height of mercury head, solution temperature, and concentration of PAR have been examined. The results were shown that the reduction current was controlled by diffusion. And the effect of proton donor such as water and phenol on DC polarograms of PAR and the reversibility of every reduction wave have been evaluated. Based on the experimental results, the polarographic reduction of PAR in acetonitrile solution occurred in two one-electron steps.

  • PDF

Estimation of CO2 Reduction by Applying Idling Stop to in-Use Vehicles (운행자동차의 공회전 정지에 의한 CO2 저감량 산출 연구)

  • Shim, Moo-Kyung;Rim, Jay-Myoung;Lee, Beom-Ho;Hong, Sung-Tae;Lee, Dae-Yup
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.10
    • /
    • pp.748-756
    • /
    • 2009
  • The effect of idling stop on $CO_2$ reduction was estimated, especially in the area of in-use vehicles. In order to know the fuel saving for each class of vehicles, a methodology to calculate the fuel saving was used along with a standard test using NIER-07 mode. Idling stop execution rate was estimated by analyzing the driving pattern of the in-use city buses, which shows about 75% at maximum. And this corresponds to about 5.4% reduction of the daily total fuel consumption. Finally, $CO_2$ reduction in the automotive sector was estimated, which concludes that, when idling stop device is used, about 480 thousand and 450 thousand tons of $CO_2$ could be reduced with in-use city buses and taxis, respectively. This amount corresponds to about 1.2% of $CO_2$ reduction in the automotive sector.