• Title/Summary/Keyword: reduction cleaning

Search Result 229, Processing Time 0.03 seconds

A Compacted In-line Wet Etch/Cleaning System With a Reverse Moving Control System

  • Im, Seung-Hyeok;Cho, Eou-Sik;Kwon, Sang-Jik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.863-866
    • /
    • 2008
  • For the cost reduction in the fabrication of display panels, a reverse moving system was equipped to a compacted in-line wet etch/cleaning system. For the effect of the alternating movement of substrate on the wet etch process, ITO layers were etched in various moving modes of substrates and the results were compared and analyzed.

  • PDF

Effectuality of Cleaning Workers' Training and Cleaning Enterprises' Chemical Health Hazard Risk Profiling

  • Suleiman, Abdulqadir M.;Svendsen, Kristin V.H.
    • Safety and Health at Work
    • /
    • v.6 no.4
    • /
    • pp.345-352
    • /
    • 2015
  • Background: Goal-oriented communication of risk of hazards is necessary in order to reduce risk of workers' exposure to chemicals. Adequate training of workers and enterprise priority setting are essential elements. Cleaning enterprises have many challenges and the existing paradigms influence the risk levels of these enterprises. Methods: Information on organization and enterprises' prioritization in training programs was gathered from cleaning enterprises. A measure of enterprises' conceptual level of importance of chemical health hazards and a model for working out the risk index (RI) indicating enterprises' conceptual risk level was established and used to categorize the enterprises. Results: In 72.3% of cases, training takes place concurrently with task performances and in 67.4% experienced workers conduct the trainings. There is disparity between employers' opinion on competence level of the workers and reality. Lower conceptual level of importance was observed for cleaning enterprises of different sizes compared with regional safety delegates and occupational hygienists. Risk index values show no difference in risk level between small and large enterprises. Conclusion: Training of cleaning workers lacks the prerequisite for suitability and effectiveness to counter risks of chemical health hazards. There is dereliction of duty by management in the sector resulting in a lack of competence among the cleaning workers. Instituting acceptable easily attainable safety competence level for cleaners will conduce to risk reduction, and enforcement of attainment of the competence level would be a positive step.

Study of the effect of cleaning the intake manifold on common rail diesel engine and exhaust gases (커먼레일 디젤엔진의 흡기 매니폴더 클리닝이 배기가스에 미치는 영향에 관한 연구)

  • Kim, Tae-Jung;Hong, Sung-In
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.5912-5918
    • /
    • 2014
  • Owing to highly developed industries and the use of fossil fuels, environmental problems becoming becoming pressing issues globally. Therefore, a study of automobile exhaust is urgently needed. Generally, air is sucked into the engine through the intake manifold. The aims of this study were to reduce the exhaust from used cars and increase the output by removing carbon deposits, which are considered a reason for the increasing exhaust and reduction of output, and the reduction of exhaust, variation of output and stability of idle speed were analyzed. The formation of carbon deposits within the suction manifold was investigated through a test device (KD147). In the intake manifold, the exhaust cleaning effect was confirmed.

Reduction of energy demand for UF cross-flow membranes in MBR by sponge ball cleaning

  • Issa, Mohammad;Geissen, Sven-Uwe;Vogelpohl, Alfons
    • Membrane and Water Treatment
    • /
    • v.12 no.2
    • /
    • pp.65-73
    • /
    • 2021
  • Sponge ball cleaning can generate an abrasion effect, which leads to an attractive increasing in both permeate flux and membrane rejection. The aim of this study was to investigate the influence of the daily sponge ball cleaning (SBC) on the performance of different UF cross-flow membrane modules integrated with a bioreactor. Two 1"-membrane modules and one 1/2"-membrane module were tested. The parameters measured and controlled are temperature, pH, viscosity, particle size, dissolved organic carbon (DOC), total suspended solids (TSS), and permeate flux. The permeate flux could be improved by 60%, for some modules, after 11 days of daily sponge ball cleaning at a transmembrane pressure of 350 kPa and a flow velocity of 4 m/s. Rejection values of all tested modules were improved by 10%. The highest permeate flux of 195 L/㎡.h was achieved using a 1"-membrane module with the aid of its negatively charged membrane material and the daily sponge ball cleaning. In addition, the enhancement in the permeate flux caused by daily sponge ball cleaning improved the energy specific demand for all tested modules. The negatively charged membrane showed the lowest energy specific demand of 1.31 kWh/㎥ in combination with the highest flux, which is a very competitive result.

A Study of On-line Cleaning Method for Increasing Efficiency in a Combustor (연소로 효율증진을 위한 on-line 세정 방법에 관한 연구)

  • Jang, Hyun-Tae;Han, Seung-Dong;Park, Tae-Sung;Cha, Wang-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.1016-1022
    • /
    • 2010
  • An Experimental study of cleaning solution has been performed on a high capacity steam boiler burning heavy fuel oil to on-line cleaning of deposit. The deposit is mixture of soot, slag, ash, metal oxide and clinker. The traditional technology of deposit cleaning was carried hand-crafted. The conventional technology of boiler cleaning method is mechanical removal by the worker while the boiler shut down operation. In this experiment, the deposit of mixture of soot, slag, ash, metal oxide and clinker has been removed by the cleaning agents without shut down of boiler burning. This study found out the optimum cleaning solution composition. The best results have been obtained when the mixture of ammonium nitrate and $MgNO_3$ were used in cleaning solution. The various transition metal effect was investigated for optimum mixing condition. In this research, the metal compound additive of the clean solution compoition was obtained. The combustion efficiency was improved by on-line cleaning with derived clean solution compoition. On-line cleaning method prevents the fouling and corrosion in the boiler and heat exchanger.

The Effect on Fouling Reduction by the Cleaning System in Compressed Type Refrigerator (압축식 냉동기에서 세정장치에 의한 파울링 억제효과)

  • 이윤표;강상우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.482-489
    • /
    • 2001
  • The present study was conducted to estimate the effect on fouling reduction in tubes of the condenser. It shows in detail how to calculate the fouling factor from the experimental results of refrigeration systems with or without the automatic cleaning system using sponge balls and to predict the variation of the factor with time. It also represents how to calculate the temperature and pressure decrease of the refrigerant vapor in the condenser and the load decrease of the compressor in the refrigeration system by fouling reduction.

  • PDF

The Effect of Blood cleaning therapy for Blood Latate Concentration (청혈요법이 혈중젖산 농도에 미치는 영향)

  • Baek Seung-Ryong;Park Rae-Joon;Kim Tae-Sook
    • The Journal of Korean Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.147-156
    • /
    • 1997
  • The purpose of this study is to determine the difference of reduction in lactic acid of blood in the course of time 1)whoa applying the blood cleaning therapy during recovery after anaerobic exercise, 2)when applying the massage during recovery after anaerobic exercise, and 3)while taking a rest during recovery after anaerobic exercise, respectively. The subject of this study consists of 30 men who are divided into three groups such as group 1(n=10) for the blood cleaning therapy, group 2(n=10) for the massage and group 3(n=10) for rest. The blood-gathering was performed over four times ; during rest, immediately after unaerobic exercise, and at 10 and 15 minutes during recovery. The results were summarized as fellows. 1. There was reduction in lactic acid when applying the blood cleaning therapy during recovery after anaerobic exercise. And remarkable differences were shown from immediately after exercise to at 10 and 15 minutes during recovery(p<0.01 and p<0.001, respectively). 2. There was also reduction in lactic acid when applying the massage during recovery after anaerobic exercise. No difference wan shown from immediately after exercise to at 10 minutes during recovery. However a remarkable difference was shown from immediately after exercise to at 15 minutes during recovery(p<0.05). 3. The rest group which took a rest during recovery after anaerobic exercise did not show any difference from immediately after exercise to at 10 and 15 minutes during recovery.

  • PDF

Influence of Plasma Corrosion Resistance of Y2O3 Coated Parts by Cleaning Process (세정공정에 따른 Y2O3 코팅부품의 내플라즈마성 영향)

  • Kim, Minjoong;Shin, Jae-Soo;Yun, Ju-Young
    • Journal of Surface Science and Engineering
    • /
    • v.54 no.6
    • /
    • pp.365-370
    • /
    • 2021
  • In this research, we proceeded with research on plasma resistance of the cleaning process of APS(Atmospheric Plasma Spray)-Y2O3 coated parts used for semiconductor and display plasma process equipment. CF4, O2, and Ar mixed gas were used for the plasma environment, and respective alconox, surfactant, and piranha solution was used for the cleaning process. After APS-Y2O3 was exposed to CF4 plasma, the surface changed from Y2O3 to YF3 and a large amount of carbon was deposited. For this reason, the plasma corrosion resistance was lowered and contamination particles were generated. We performed a cleaning process to remove the defect-inducing surface YF3 layer and carbon layer. Among three cleaning solutions, the piranha cleaning process had the highest detergency and the alconox cleaning process had the lowest detergency. Such results could be confirmed through the etching amount, morphology, composition, and accumulated contamination particle analysis results. Piranha cleaning process showed the highest detergency, but due to the very large thickness reduction, the base metal was exposed and a large number of contaminated particles were generated. In contrast, the surfactant cleaning process exhibit excellent properties in terms of surface detergency, etching amount, and accumulated contamination particle analysis.

A Study on the Antibacteria Effect and the Properties Change by Treatment of Chrome-Tanned Garment Leathers. -On the Changes by Dry Cleaning- (의류용 크롬유혁의 가공처리에 따른 항미생물효과 및 특성변화에 관한 연구 -드라이클리닝에 의한 변화를 중심으로-)

  • Cho, Seung-Shick;Sim, Mi-Sook;Kim, Un-Bae
    • Textile Coloration and Finishing
    • /
    • v.3 no.2
    • /
    • pp.10-15
    • /
    • 1991
  • This study was to examine the anti-bacteria effect and the changes of chemical properties of chrome-tanned garment leathers on the preservative treatment. Various test methods, such as investigation of preservative treatment process, resistance test and chemical analysis by cleaning, antbbacterial test by shake flask method are carried out in this study. The results can be obtained as follows: 1. Bacterial reduction percentage of chrome-tanned garment leathers on the preservative treatment was 28.6%. 2. In the antbbacterial effect by dry cleaning, preservative treated leathers has no resistance. 3. Fats content has been removed by dry cleaning using perchloroethylene, so garment leathers properties were altered. 4. PH value was changed by dry cleaning. But once after fats removing, it was changed the little by dry cleaning numbers.

  • PDF

A Study on IR Characterization of Electrolyzed Water for Si Wafer Cleaning (전리수를 이용한 Si 웨이퍼 세정의 IR 특성연구)

  • Byeongdoo Kang;Kunkul Ryoo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.05a
    • /
    • pp.124-128
    • /
    • 2001
  • A present semiconductor cleaning technology is based upon RCA cleaning technology which consumes vast amounts of chemicals and ultra pure water(UPW) and is the high temperature Process. Therefore, this technology gives rise to the many environmental issues, and some alternatives such as functional water cleaning are being studied. The electrolyzed water was generated by an electrolysis system which consists of anode, cathode, and middle chambers. Oxidative water and reductive water were obtained in anode and cathode chambers, respectively. In case of NH$_4$Cl electrolyte, the oxidation-reduction potential and pH for anode water(AW) and cathode water(CW) were measured to be +1050mV and 4.8, and -750mV and 10.0, respectively. AW and CW were deteriorated after electrolyzed, but maintained their characteristics for more than 40 minutes sufficiently enough for cleaning. Their deterioration was correlated with CO$_2$ concentration changes dissolved from air. It was known that AW was effective for Cu removal, while CW was more effective for Fe removal. The particle distributions after various particle removal processes maintained the same pattern. In this work, RCA consumed about 9$\ell$chemicals, while EW did only 400$m\ell$ HCI electrolyte or 600$m\ell$ NH$_4$Cl electrolyte. It was hence concluded that EW cleaning technology would be very effective for eliminating environment, safety, and health(ESH) issues in the next generation semiconductor manufacturing.