• 제목/요약/키워드: reduction DC voltage

검색결과 270건 처리시간 0.018초

DC-Link Voltage Balance Control Using Fourth-Phase for 3-Phase 3-Level NPC PWM Converters with Common-Mode Voltage Reduction Technique

  • Jung, Jun-Hyung;Park, Jung-Hoon;Kim, Jang-Mok;Son, Yung-Deug
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.108-118
    • /
    • 2019
  • This paper proposes a DC-link voltage balance controller using the fourth-phase of a three-level neutral-point clamped (NPC) PWM converter with medium vector selection (MVS) PWM for common-mode voltage reduction. MVS PWM makes the voltage reference by synthesizing the voltage vectors that cannot generate common-mode voltage. This PWM method is effective for reducing the EMI noise emitted from converter systems. However, the DC-link voltage imbalance problem is caused by the use of limited voltage vectors. Therefore, in this paper, the effect of MVS PWM on the DC-link voltage of a three-level NPC converter is analyzed. Then a proportional-derivative (PD) controller for the DC-link voltage balance is designed from the DC-link modeling. In addition, feedforward compensation of the neutral point current is included in the proposed PD controller. The effectiveness of the proposed controller is verified by experimental results.

dc/dc 컨버터의 스위칭 소자의 전압 스트레스 (Voltage Stress of Switching Device in dc/dc Converter)

  • 마근수;최진호;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1019-1021
    • /
    • 1992
  • This paper deals with the stress of the converters using the resonant switches. It is represented the reduction of the voltage and current stresses. According to the configuration of the multiple poly-phase converter. Especially, about buck ZVS-QRC it is studied the reduction of the voltage stress, and represented the result of simulation.

  • PDF

단상 다기능 UPS 입.출력 필터 설계 (Design of Input.Output Filter of Single Multifunctional UPS)

  • 김제홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.307-310
    • /
    • 2002
  • A design for the input filter and the output filter of a single-phase UPS system is proposed. And also, this paper describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

LLC 공진 컨버터의 120Hz 출력전압 리플 저감을 위한 전향보상 방법 (A Feedforward Compensation Method for 120Hz Output Voltage Ripple Reduction of LLC Resonant Converter)

  • 윤종태;이귀준
    • 전력전자학회논문지
    • /
    • 제26권1호
    • /
    • pp.46-52
    • /
    • 2021
  • This study proposes a feedforward compensation control method to reduce 120 Hz output voltage ripple in a single-phase AC/DC rectifier system composed of PFC and LLC resonant converters. The proposed method compensates for the voltage ripple of the DC-link by using the AC input and DC output power difference, and then reduces the final output voltage ripple component of 120 Hz through feedforward compensation based on the linearized frequency gain curve of the LLC resonant converter. Through simulation and experimental results, the validity of the ripple reduction performance was verified by comparing the conventional PI controller and the proposed feedforward compensation method.

Mitigation of Low Frequency AC Ripple in Single-Phase Photovoltaic Power Conditioning Systems

  • Lee, Sang-Hoey;An, Tae-Pung;Cha, Han-Ju
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.328-333
    • /
    • 2010
  • A photovoltaic power conditioning system (PV PCS) that contains single-phase dc/ac inverters tends to draw an ac ripple current at twice the output frequency. Such a ripple current perturbs the operating points of solar cells continuously and it may reduce the efficiency of the current based maximum power point tracking technique (CMPPT). In this paper, the ripple current generation in a dc link and boost inductor is analyzed using the ac equivalent circuit of a dc/dc boost converter. A new feed-forward ripple current compensation method to incorporate a current control loop into a dc/dc converter for ripple reduction is proposed. The proposed feed-forward compensation method is verified by simulation and experimental results. These results show a 41.8 % reduction in the peak-to peak ac ripple. In addition, the dc/ac inverter control system uses an automatic voltage regulation (AVR) function to mitigate the ac ripple voltage effect in the dc link. A 3kW PV PCS prototype has been built and its experimental results are given to verify the effectiveness of the proposed method.

Two Modified Z-Source Inverter Topologies - Solutions to Start-Up Dc-Link Voltage Overshoot and Source Current Ripple

  • Bharatkumar, Dave Heema;Singh, Dheerendra;Bansal, Hari Om
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1351-1365
    • /
    • 2019
  • This paper proposes two modified Z-source inverter topologies, namely an embedded L-Z-source inverter (EL-ZSI) and a coupled inductor L-Z source inverter (CL-ZSI). The proposed topologies offer a high voltage gain with a reduced passive component count and reduction in source current ripple when compared to conventional ZSI topologies. Additionally, they prevent overshoot in the dc-link voltage by suppressing heavy inrush currents. This feature reduces the transition time to reach the peak value of the dc-link voltage, and reduces the risk of component failure and overrating due to the inrush current. EL-ZSI and CL-ZSI possess all of the inherent advantages of the conventional L-ZSI topology while eliminating its drawbacks. To verify the effectiveness of the proposed topologies, MATLAB/Simulink models and scaled down laboratory prototypes were constructed. Experiments were performed at a low shoot through duty ratio of 0.1 and a modulation index as high as 0.9 to obtain a peak dc-link voltage of 53 V. This paper demonstrates the superiority of the proposed topologies over conventional ZSI topologies through a detailed comparative analysis. Moreover, experimental results verify that the proposed topologies would be advantageous for renewable energy source applications since they provide voltage gain enhancement, inrush current, dc-link voltage overshoot suppression and a reduction of the peak to peak source current ripple.

RF 노이즈 내성을 가진 OLED 디스플레이용 2-채널 DC-DC 변환기 (2-Channel DC-DC Converter for OLED Display with RF Noise Immunity)

  • 김태운;김학윤;최호용
    • 전기전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.853-858
    • /
    • 2020
  • 본 논문은 통신기기에서 유입 되는 RF 노이즈에 대해 내성을 가진 OLED용 2-채널 DC-DC 변환기를 제안한다. RF 신호 내성을 위해, 입력전압 변동만큼 감쇠시키는 입력전압 변동감쇠 회로가 내장된다. 양의 전압 VPOS를 출력하는 부스트 변환기는 SPWM-PWM 듀얼모드로 동작하고, 데드 타임을 제어함으로써 전력 효율을 제고한다. VNEG를 출력하는 인버팅 차지펌프는 2-상 출력 구조로 VCO를 이용한 PFM으로 동작해 작은 리플을 갖도록 설계된다. 0.18 ㎛ BCDMOS 공정으로 시뮬레이션 한 결과, 부스트 변환기 출력전압의 오버슈트와 언더슈트는 10 mV에서 각각 2 mV, 5 mV로 감소하였다. 또한, 2-채널 DC-DC 변환기의 전력효율은 39%~93%을 가졌고, 데드 타임 제어기를 적용한 부스트 변환기의 효율은 종전보다 최대 3% 증가하였다.

입·출력 전압 변동을 고려한 3상 인터리브드 양방향 DC-DC컨버터의 전류리플 저감 기법 (Current Ripple Reduction Method of 3-phase Interleaved Bidirectional DC-DC Converter with the Consideration of Input and Output Voltage Variation)

  • 선다운;정재헌;노의철;정규범
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.427-433
    • /
    • 2016
  • This paper proposes a new method for the current ripple reduction of a three-phase interleaved bidirectional DC-DC converter. Usually, the three-phase interleaved bidirectional DC-DC converter is used for battery charging and discharging to reduce battery current ripple. In V2G application, a PWM AC-DC converter is used to connect the AC power grid and three-phase interleaved bidirectional DC-DC converter for battery charging and discharging. The magnitude of DC link voltage affects the battery current ripple magnitude. Therefore, the magnitude of the battery ripple current is analyzed with variations of battery and DC link voltages. The ripple current magnitude is found to be minimized by controlling the DC link voltage. Simulation and experimental results show the usefulness of the proposed method.

예비 서브모듈을 활용한 모듈형 멀티레벨 컨버터의 스위칭 주파수 저감 기법 (Switching Frequency Reduction Method for Modular Multi-level Converter Utilizing Redundancy Sub-module)

  • 이윤석;유승환;최종윤;박용희;한병문;윤영두
    • 전기학회논문지
    • /
    • 제63권12호
    • /
    • pp.1640-1648
    • /
    • 2014
  • This paper proposes a switching frequency reduction method for MMC (Modular Multilevel Converter) utilizing redundancy operation of sub-module, which can offer reduction of voltage harmonics and switching loss. The feasibility of proposed method was verified through computer simulations with PSCAD/EMTDC software. Based on simulation analysis, a hardware scaled-model of 10kVA, DC-1000V MMC was designed and manufactured in the lab. Various experiments were conducted to verify the feasibility of proposed method in the actual hardware system. The hardware scaled-model can be effectively utilized for analyzing the performance of MMC according to the modulation scheme and redundancy operation.

침대평판전극에서의 NOx 제거특성 (Reduction characteristics of NOx on point-plane electrode)

  • 김건호;김종달;김정달;김치원;이덕출;고희석;박재윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1317-1319
    • /
    • 1995
  • In this paper, we studied reduction characteristics of NOx gas produced from diesel engine combustion using by point-plane electrode. Here, input voltage forms were types of three [DC, AC, DC Positive pulse] and NOx gas of 1700ppm was composed of NO 1665ppm, $NO_2$ 35ppm on balance of $N_2$. We investigated NOx reduction characteristics as various of parameters, are gas flow rate, input voltage form and, humidity. From the results of study, reduction characteristics of NOx exhibited good when gas flow rate was small, input voltage was DC and much humidity were contained to NOx gas.

  • PDF