• 제목/요약/키워드: reduced system

검색결과 9,957건 처리시간 0.047초

Low price Fuel Cell Inverter System for 3[KW] Residential Power

  • Kwon, Soon-Kurl
    • 조명전기설비학회논문지
    • /
    • 제21권4호
    • /
    • pp.61-72
    • /
    • 2007
  • This study proposed a high efficiency DC-DC converter with a new current doubler rectifier for fuel-cell systems for use with the Nexa(310-0027) PEMFC from the Ballard Co. The proposed high efficiency DC-DC converter for the fuel-cell system generated ZVS by applying partial resonance and using a phase shift PWM control method. Constantly switching frequency, loss of switching, peak current, and peak voltage were reduced by this system. In addition to this system, two inductors were attached to a rectifier circuit allowing it to be able to provide the direct current(DC) and DC voltage safely to a load with reduced ripple components. Also, by using the newly proposed current doubler rectifier, the high frequency DC-DC converter for the fuel cell system was capable of reaching a highest efficiency of 92[%] as compared to 88.3[%] efficiency in previous results, which means that efficiency increased 3.7[%]. The overall results were confirmed by a simulation and laboratory experiment.

An Accelerated Inverse Perturbation Method for Structural Damage Identification

  • Park, Young-Jae;Lee, Usik
    • Journal of Mechanical Science and Technology
    • /
    • 제17권5호
    • /
    • pp.637-646
    • /
    • 2003
  • In the previous study, the inverse perturbation method was used to identify structural damages. Because all unmeasured DOFs were considered as unknown variables, considerable computational effort was required to obtain reliable results. Thus, in the present study, a system condensation method is used to transform the unmeasured DOFs into the measured DOFs, which eliminates the remaining unmeasured DOFs to improve computational efficiency. However, there may still arise a numerically ill-conditioned problem, if the system condensation is not adequate for numerical Programming or if the system condensation is not recalibrated with respect to the structural changes. This numerical problem is resolved in the present study by adopting more accurate accelerated improved reduced system (AIRS) as well as by updating the transformation matrix at every step. The criterion on the required accuracy of the condensation method is also proposed. Finally, numerical verification results of the present accelerated inverse perturbation method (AIPM) are presented.

멱급수 오차를 고려하여 선택된 고유치에 의한 모델 저차화 방법 (Model reduction by the eigenvalue selected considering the error of the power series)

  • 김원호;최태호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.155-160
    • /
    • 1987
  • In this paper, the model reduction method of the linear time invariant continuous systems is proposed. The denominator of reduced order model is determined by the eigenvalue selected considering the error of the power series that exists between original system and reduced order system at each time moments. And the numerator of model is founded by the time moment matching method. The method suggested is compared with other various methods in examples.

  • PDF

Lyapunov 부등식을 이용한 주파수하중 차수축소 (Frequency weighted reduction using Lyapunov inequalities)

  • 오도창;정은태;이상경
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.12-12
    • /
    • 2000
  • This paper consider a new weighted model reduction using block diagonal solutions of Lyapunov inequalities. With the input and/or output weighting function, the stability of reduced order system is quaranteed and a priori error bound is proposed. to achieve this, after finding the solutions of two Lyapunov inequalities and balancing the full order system, we find the reduced order systems using the direct truncation and the singular perturbation approximation. The proposed method is compared with other existing methods using numerical example.

  • PDF

배터리 저장 시스템용 고승압 양방향 컨버터 (High Step-Up Bidirectional DC-DC Converter for Battery Storage System)

  • Zhang, Hai-Long;Park, Sung-Jun;Kim, Dong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.320-321
    • /
    • 2018
  • A non-isolated high voltage gain bidirectional DC-DC converter for battery storage system has been presented in this paper. The topology is composed of boost converter and traditional SEPIC converter. The proposed converter can achieve higher voltage conversion ratio with reduced voltage and current stresses in the switches. In additional, a reduced number of components are included in this topology. The PSIM simulation is carried to validate the analysis and operation of the converter.

  • PDF

OFDM-CDMA 시스템에서 부분병렬환을 이용한 PAPR 감쇄기법 (Peak-to-Average Power Ratio Reduction by Partial Parallel Transform in an OFDM-CDMA System)

  • 주양익
    • 한국통신학회논문지
    • /
    • 제25권10A호
    • /
    • pp.1548-1553
    • /
    • 2000
  • In this paper, an effective peak power reduction scheme for a downlink OFDM-CDMA system is proposed. Using the partial parallel transform(PPT) structure, peak-to-average power ratio(PAPR) can be reduced. The patterns of inputs of Inverse Fast Fourier Transform(IFFT) are more randomized in this structure by allotting the subcarriers to each users. At the cost of complexity we can obtain reduced PAPR and multiple access interference(MA) Computer simulations are carried out from the viewpoint of PAPR and demonstrated the improved PAPR performance.

  • PDF

Input-Output Feedback Linearizing Control With Parameter Estimation Based On A Reduced Design Model

  • Noh, Kap-Kyun;Dongil Shin;Yoon, En-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.87.2-87
    • /
    • 2001
  • By the state transformation including independent outputs functions, a nonlinear process model can be decomposed into two subsystems; the one(design model) is described in output variables as new states and used for control system synthesis and the other(disturbance model) is described in the original unavailable states and its couplings with the design model are treated as uncertain time-varying parameters in the design model. Its existence with respect to the design model is ignored. So, the design model is an uncertain time-variant system. Control synthesis based on a reduced design model is a combined ...

  • PDF

IPS 흙막이 가시설의 수평 변위 계측을 통한 선행하중 효과 수치해석적 분석 (An Numerical Analysis of the Preloading Effect of IPS Retaining Wall through Earth Horizontal Displacement Measuring)

  • 이치호;이종휘;이창기;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제13권5호
    • /
    • pp.25-33
    • /
    • 2012
  • 본 연구에서는 흙막이 가시설 공법중 지반의 변위를 억제하고, 토공사 및 구조물 공사의 시공성을 크게 개선한 IPS 흙막이 가시설 공법을 시공한 현장의 계측자료를 바탕으로, 탄소성보법 수치해석 프로그램(EXCAV/W)을 이용하여 수치해석을 실시하였다. 그 결과, 선행하중을 가한 해석치가 평균 13.2% 감소하였으며, 또한 일반적인 해석치보다 현장 계측치는 평균 26.7% 감소하는 것으로 나타났다. 따라서 IPS 흙막이 가시설 공법은 기존 버팀보 공법에 흙막이벽의 수평변위에 대한 안전성을 확보하고 있음을 알 수 있다. 또한 IPS 흙막이 가시설 공법을 이용한 선행하중 효과를 통해 수평변위가 감소하는 것을 확인할 수 있다.

원전 종사자 및 조직 특성이 사고에 미치는 영향 (A Study on the Effects of Nuclear Power Plant Workers and Organizational Characteristics on Accidents)

  • 김병석;조현웅;오영민
    • 한국시스템다이내믹스연구
    • /
    • 제15권2호
    • /
    • pp.5-25
    • /
    • 2014
  • The purpose of this study is to analyze the effects of nuclear power plant workers and organizational characteristics on accidents, and seek the combination of policies for reducing accidents. For this purpose, it grasped, by using System Dynamics and Causal Loop Diagram, how various factors that cause accidents in nuclear plants are interrelated, and performed simulations after building simulation models. As a result of the analysis, first, the fundamental cause of safety accidents in nuclear power plants turned out to be the time constraint on the workload. Second, it turned out that as the workload of workers increases, physical and mental stresses increase, thereby increasing accidents due to errors and violations. Third, it turned out that as the levels of educational training and compliance with regulations and procedures are enhanced, accidents are reduced. Lastly, it turned out that as the combination of policies (reliance level + working environment + educational training + compliance with regulations and procedures) is increased, accidents are reduced. Especially, it turned out that if the combination of policies is increased by 30%, more than 10 cases of accidents are reduced.

  • PDF

2단계 동적 축소법을 적용한 구조물의 위상 최적 설계 (Structural Topology Optimization Using Two-level Dynamic Condensation Scheme)

  • 박수현;김현기;조맹효
    • 한국전산구조공학회논문집
    • /
    • 제19권2호
    • /
    • pp.213-219
    • /
    • 2006
  • 위상 최적화 문제는 다양한 밀도 분포를 가지는 설계영역에서 목적함수와 요소단위의 설계 민감도의 반복적인 계산을 요구한다. 최근 제안된 2단계 축소기법은 축소 시스템을 구축하는데 매우 효과적이며 고유치 문제와 동적 문제의 해석에 정확도와 효율성을 동시에 제공한다. 본 논문에서는 구조 위상 최적화 문제에서 해석 부분과 민감도 계산 부분에 2단계 동적 축소기법을 사용한다. 축소시스템에 대한 위상 최적화 결과는 축소되지 않은 전체 시스템에 대한 최적화 결과와 비교하여도 공학적으로 요구되는 정확도 범위 내에서 2단계 축소기법이 높은 정확도와 계산 효율을 보장하는 것을 보여준다.