• Title/Summary/Keyword: reduced frequency

Search Result 3,044, Processing Time 0.035 seconds

Seismic Performance Evaluation of Seismic Isolation Device with Double Slip Friction Surface (이중 슬립마찰면을 이용한 면진장치의 면진성능평가)

  • Son, Su-Won;Kwon, Jeong-Ho;Kim, Jung-Gon;Jung, Yong-Gyu;Hwang, Eun-Dong
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.712-722
    • /
    • 2020
  • Purpose: The damage from earthquakes with a magnitude of 5.0 or greater Korea has increased in South Korea. When a earthquake occurs, internal facilities and electric equipment besides urban structures will be damaged. Thus, in this paper, an earthquake-induced seismic isolation device with double slip fiction surfaces which can reduce the damage of electric power equipment such as distribution panel and then the seismic performance was evaluated. Method: To evaluate the seismic performance shaking table test was performed, a seismic performance comparison was performed according to the presence or absence of a seismic isolation device. The attenuation effect of the seismic isolation device are analyzed by comparing response acceleration and displacement for different frequencies and acceleration levels. Result: As a result of the test, the acceleration amplification was up to 42% less than when the seismic isolation device was installed in comparison to the other case without the seismic device. This is believed that the amplification energy has reduced because the displacement between the double slip friction surfaces of the seismic device play a role in dissipating the seismic energy. Conclusion: The seismic device with double slip friction surfaces has a greater earthquake attenuation effect in strong earthquakes than in weak ones, so the greater the frequency, the better the earthquake attenuation effect. Therefore, it is judged that earthquake energy can be decreased by applying to electric equipment such as distribution panels.

Effects of dietary inactivated probiotics on growth performance and immune responses of weaned pigs

  • Kang, Joowon;Lee, Jeong Jae;Cho, Jin Ho;Choe, Jeehwan;Kyoung, Hyunjin;Kim, Sung Hun;Kim, Hyeun Bum;Song, Minho
    • Journal of Animal Science and Technology
    • /
    • v.63 no.3
    • /
    • pp.520-530
    • /
    • 2021
  • This experiment was performed to verify whether dietary heat-killed Lactobacillus rhamnosus (LR) improves growth performance and modulates immune responses of weaned pigs. Ninety-six weaned pigs ([Landrace × Yorkshire] × Duroc; 6.95 ± 0.25 kg body weight [BW]; 28 d old) were randomly allocated to four treatments: 1) a basal diet without heat-killed LR (CON), 2) T1 (CON with 0.1% heat-killed LR), 3) T2 (CON with 0.2% heat-killed LR), and 4) T3 (CON with 0.4% heat-killed LR). Each treatment had six pens with four pigs (6 replicates per treatment) in a randomized completely block design. The heat-killed LR used in this study contained 1 × 109 FU/g of LR in a commercial product. Pigs were fed each treatment for four weeks using a two-phase feeding program to measure growth performance and frequency of diarrhea. During the last week of this study, all diets contained 0.2% chromic oxide as an indigestible marker. Fecal sampling was performed through rectal palpation for the consecutive three days after the four adaptation days to measure apparent total tract digestibility (ATTD) of dry matter, crude protein, and gross energy (GE). Blood sampling was also performed on day 1, 3, 7, and 14 after weaning to measure immune responses such as serum tumor necrosis factor-α (TNF-α), transforming growth factor-β1 (TGF-β1), C-reactive protein (CRP), and cortisol. The heat-killed LR increased (p < 0.05) growth rate, feed efficiency, and ATTD of GE for overall experimental period compared with CON, but reduced (p < 0.05) post-weaning diarrhea. In addition, pigs fed diets contained heat-killed had lower concentrations of serum TNF-α (d 7; p < 0.05), TGF-β1 (d 7; p < 0.10), and cortisol (d 3 and 7; p < 0.05) than pigs fed CON. In conclusion, dietary heat-killed LR improved growth rate, modified immune responses of weaned pigs, and alleviated post-weaning diarrhea.

Effect of one time laughter therapy on job stress and job involvement of geriatric hospital workers (일회성 웃음치료가 노인요양병원 업무종사자의 직무스트레스와 직무몰입에 미치는 효과)

  • Han, Mi Ra;Kang, Ji Sook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • This study was intended to prepare a basis to apply one time laughter therapy in clinical circumstances as an intervention for reducing job stress and improve job involvement of geriatric hospital workers by identifying the effect of one time laughter therapy on their physiological stress responses, job stress, and job involvement. This study was a Non-Equivalent control group pre-post design to validate the effect of one time laughter therapy. The participants of this study included 80 staffs of 2 geriatric hospitals located in I city, including 40 persons in each experimental and control group. Consent was obtained from the participants, after explaining sufficiently study purpose, blood pressure and pulse rate measurement, serum cortisol level measurement, and a questionnaire on job stress and job involvement and data collection was performed 2 times each, before and after the experimental procedure. For the collected data, frequency, percentage, average and standard deviation, χ2 test, Fisher's exact test and t-test were conducted using SPSS Win 19.0. The results of this study were as follows. The systolic blood pressure and the serum cortisol level were reduced significantly. It was found that although there was no significant difference between the experimental group and the control group in job stress and job involvement. Therefore, it was identified that the one time laughter therapy was an effective nursing intervention to reduce physiological stress response of geriatric hospital workers.

Design and Implementation of Mobile Medical Information System Based Radio Frequency IDentification (RFID 기반의 모바일 의료정보시스템의 설계 및 구현)

  • Kim, Chang-Soo;Kim, Hwa-Gon
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.317-325
    • /
    • 2005
  • The recent medical treatment guidelines and the development of information technology make hospitals reduce the expense in surrounding environment and it requires improving the quality of medical treatment of the hospital. That is, with the new guidelines and technology, hospital business escapes simple fee calculation and insurance claim center. Moreover, MIS(Medical Information System), PACS(Picture Archiving and Communications System), OCS(Order Communicating System), EMR(Electronic Medical Record), DSS(Decision Support System) are also developing. Medical Information System is evolved toward integration of medical IT and situation si changing with increasing high speed in the ICT convergence. These changes and development of ubiquitous environment require fundamental change of medical information system. Mobile medical information system refers to construct wireless system of hospital which has constructed in existing environment. Through RFID development in existing system, anyone can log on easily to Internet whenever and wherever. RFID is one of the technologies for Automatic Identification and Data Capture(AIDC). It is the core technology to implement Automatic processing system. This paper provides a comprehensive basic review of RFID model in Korea and suggests the evolution direction for further advanced RFID application services. In addition, designed and implemented DB server's agent program and Client program of Mobile application that recognized RFID tag and patient data in the ubiquitous environments. This system implemented medical information system that performed patient data based EMR, HIS, PACS DB environments, and so reduced delay time of requisition, medical treatment, lab.

  • PDF

Effectiveness Evaluation of Displacement Accommodatable Pressure Measuring Jig for Quality Assessment of Pressure Application Device (압력 인가 장치의 품질관리를 위한 변위 수용이 가능한 압력 측정용 지그의 유효성 평가)

  • Mun, Chang-Su;Jun, Sung-Chul;Noh, Si-Cheol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.2
    • /
    • pp.61-66
    • /
    • 2020
  • Recently, a variety of electric anesthetics devices have been developed and used in clinical practice to reduce the fatigue of the operator during local anesthesia for dental procedures and to compensate for the disadvantages of manual anesthesia device. In this electric anesthesia injection device, the accurate and constant delivery of pressure for drug infusion is a very important performance factor. In order to evaluate the accuracy of the transfer pressure, a small pressure gauge using a load cell is often used, but since the elastic body inside the load cell may not be able to accommodate a sufficient displacement, an error may occur when evaluating pressure performance. For these reasons, in this study, we proposed and evaluated a silicon-chrome steel (Si-Cr steel) spring jig that can accommodate relatively large displacements that can be used when evaluating the performance of a pressure-controlled pressure application device using a load cell type pressure gauge. As a result of the pressure transmissibility test and repeated measurement results using a commercial dental anesthesia injection device, a more stable result was obtained when using a spring jig, and it was confirmed that the frequency of abnormally high measurement was reduced.

The Effects of Different Surface Level on Muscle activity of the Upper Body and Exercise Intensity during Mountain Climbing Exercise (지면에서의 마운틴 클라이밍 운동 시 상체의 위치 변화가 운동 강도와 근활성도에 미치는 영향)

  • Park, Jun-Ho;Jung, Jae-Hu;Kim, Jong-Geun;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.1
    • /
    • pp.72-78
    • /
    • 2021
  • Objective: The purpose of this study was to investigate relations and effectiveness about mountain climbling exercise with different level of support surfaces by analyzing heart rate and EMG data. A total of 10 male college students with no musculoskeltal disorder were recruited for this study. Method: The biomechanical analysis was performed using heart rate monitor (Polar V800, Polar Electro Oy, Finland), step-box, exercise mat, and EMG device (QEMG8, Laxtha Inc. Korea, sampling frequency = 1,024 Hz, gain = 1,000, input impedance > 1012 Ω, CMRR > 100 dB). In this research, step-box were used to create different surface levels on the upper body (flat surface, 10% of subject's height, 20% of subject's height, and 30% of subject's hight). Based on these different conditions, data was collected by performing mountain climbing exercise during 30 seconds. Subjects were given 5 minutes of break to prevent muscular fatigue after each exercise. For each dependent variable, a one-way analysis of variance with repeated measures was conducted to find significant differences and Bonferroni post-hoc test was performed. Results: The results of this study showed that exercise intensity was reduced statistically as increased surface level on the upper body. Muscle activity of the upper rectus abdominis and biceps femoris for 30% of surface level was significantly higher than the corresponding values for flat surface. However, the opposite was found in the rectus femoris. In general, muscle activity of the lower rectus abdominis, erector spinae, external oblique abdominis, and gluteus maximus increased when surface level increased, but the differences were not significant. Conclusion: As a result, the increase in surface level of the body would change muscle activity of the upper body, indicating that different surface level of the upper body may cause significant effect on particular muscles to be more active during mountain climbing exercise. Based on results of this study, it is suggested to set up an appropriate surface level to target particular muscle to expect an effective training. It is also important to set adequate surface levels to create an effective training condition for preventing exercise injuries.

A Study on the Effects of Protective Behavioral Strategies on Alcohol-Related Harms in Adults (보호행동전략이 성인의 음주폐해에 끼치는 영향에 관한 연구)

  • Lee, Hee Jong;Park, Ka Young
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.5
    • /
    • pp.627-637
    • /
    • 2021
  • Many efforts have been made to prevent alcohol related harms such as health problems and socio-economic problems. Among them, the method of improving drinking behavior at the individual level is the most direct intervention. The effectiveness of the use of protective behavior strategies(PBS) has been widely known in Western countries. The purpose of this study is to empirically verify whether the use of PBS affects alcohol related harms in Korean adults. The survey has been conducted on 2,000 adult men and women. As a result, it is found that the use of PBS reduced alcohol related harms in adults. Among the PBS, the biggest impact on alcohol related harms is the area related serious harm reduction strategy, followed by restrictions on 'manner of drinking'. The effects of 'limiting/ stopping of drinking' is not significant. In addition, drinking frequency, binge drinking, and drinking motivations have significant positive effects on alcohol-related harms, and only social motivation has a negative effect. In this work, we propose follow-up studies on identifying relationships between protective behaviors and alcohol related factors through longitudinal studies and strengthening the use of protective behavior strategies that applied to the refined target populations.

A Study on Inhibition of Bacterial Membrane Formation in Biofilm formed by Acne Bacteria in Valine through Property Analysis (물성 분석을 통한 Valine 의 여드름균 바이오필름 내부 세균막 형성 억제 연구)

  • Song, Sang-Hun;Hwang, Byung Woo;Son, Seongkil;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.2
    • /
    • pp.163-170
    • /
    • 2021
  • This study was conducted to create a technology to remove acne bacteria with human-friendly materials. First, the Cutibacterium acnes (C. acnes) were adsorbed to the mica disc to grow, and then the biofilm was checked through an atomic microscope to see if the biofilm had grown. Based on the topographic image, the shape changed round, the size was 17% longer on average, and the phase value of the resonance frequency separating materials was observed as a single value, the biofilm grown by covering the extracellular polymeric substrate (EPS). As a result of processing 50 mM of amino acids in the matured biofilm, the concentration of C. acnes decreased when valine, serine, arginine and leucine were treated. Scanning with nanoindentation and AFM contact modes confirmed that the hardness of biofilms treated with Valine (Val) increased. This indicates that an AFM tip measured cell which may have more solidity than that of EPS. The experiment of fluorescent tagged to EPS displays an existence of EPS at the condition of 10 mM Val, but an inhibition of growth of EPS at the 50 mM Val. Number of C. acnes was also reduced above 10 mM of Val. Weak adhesion of biofilm generated from an inhibition of EPS formation seems to induce decrease of C. acnes. Accordingly, we elucidated that Val has an efficiency which eliminates C. acnes by approach of an inhibition of EPS.

Qualitative Verification of the LAMP Hail Prediction Using Surface and Radar Data (지상과 레이더 자료를 이용한 LAMP 우박 예측 성능의 정성적 검증)

  • Lee, Jae-yong;Lee, Seung-Jae;Shim, Kyo-Moon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.24 no.3
    • /
    • pp.179-189
    • /
    • 2022
  • Ice and water droplets rise and fall above the freezing altitude under the effects of strong updrafts and downdrafts, grow into hail, and then fall to the ground in the form of balls or irregular lumps of ice. Although such hail, which occurs in a local area within a short period of time, causes great damage to the agricultural and forestry sector, there is a paucity of domestic research toward predicting hail. The objective of this study was to introduce Land-Atmosphere Modeling Package (LAMP) hail prediction and measure its performance for 50 hail events that occurred from January 2020 to July 2021. In the study period, the frequency of occurrence was high during the spring and during afternoon hours. The average duration of hail was 15 min, and the average diameter of the hail was 1 cm. The results showed that LAMP predicted hail events with a detection rate of 70%. The hail prediction performance of LAMP deteriorated as the hail prediction time increased. The radar reflectivity of actual cases of hail indicated that the average maximum reflectivity was greater than 40 dBZ regardless of altitude. Approximately 50% of the hail events occurred when the reflectivity ranged from 30~50 dBZ. These results can be used to improve the hail prediction performance of LAMP in the future. Improved hail prediction performance through LAMP should lead to reduced economic losses caused by hail in the agricultural and forestry sector through preemptive measures such as net coverings.

Analysis and verification of the characteristic of a compact free-flooded ring transducer made of single crystals (압전단결정을 이용한 소형 free-flooded ring 트랜스듀서의 성능 특성 예측 및 검증)

  • Im, Jongbeom;Yoon, Hongwoo;Kwon, Byungjin;Kim, Kyungseop;Lee, Jeongmin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.3
    • /
    • pp.278-286
    • /
    • 2022
  • In this study, a 33-mode Free-Flooded Ring (FFR) transducer was designed to apply piezoelectric single crystal PIN-PMN-PT, which has high piezoelectric constants and electromechanical coupling coefficient. To ensure low-frequency high transmitting sensitivity characteristics with a small size of FFR transducer, the commercial FFR transducer based on piezoelectric ceramics was compared. To develop the FFR transducer with broadband characteristics, a piezoelectric segmented ring structure inserted with inactive elements was applied. The oil-filled structure was applied to minimize the change of acoustic characteristics of the ring transducer. It was verified that the transmitting voltage response, underwater impedance, and beam pattern matched the finite element numerical simulation results well through an acoustic test. The difference in the transmitting voltage response between the measured and the simulated results is about 1.3 dB in cavity mode and about 0.3 dB in radial mode. The fabricated FFR transducer had a higher transmitting voltage response compared to the commercial transducer, but the diameter was reduced by about 17 %. From this study, it was confirmed that the feasibility of a single crystal-applied FFR transducer with compact size and high-power characteristics. The effectiveness of the performance prediction by simulation was also confirmed.