• 제목/요약/키워드: reduced frequency

검색결과 3,038건 처리시간 0.04초

DFT 기반 페이저 연산 시 새로운 저역통과필터를 이용한 고주파 노이즈 경감 방법 (High Frequency Noise Reduction Method Using a Newly Designed Low-pass Filter in DFT-Based Phasor Estimation)

  • 백민우;강상희
    • 전기학회논문지
    • /
    • 제66권6호
    • /
    • pp.898-904
    • /
    • 2017
  • DFT(Discrete Fourier Transform) is one of the most widely used method to estimate the phasor of a relaying signal. The harmonics are eliminated by the DFT. However, high frequency components, except for harmonics, are not removed and cause an error in DFT-based phasor estimation process. This paper suggests high frequency noise reduction method by using a newly designed low-pass filter to estimate a signal phasor. When selecting a stop-band cut-off frequency of the low-pass filter, high frequency components generated by faults are considered. To reduce the phasor estimation delay caused by a low-pass filter, this paper proposes a low-pass filter whose settling time is reduced. An adverse effect of high frequency noise on DFT-based phasor estimation is reduced. To evaluate the performance of the proposed method, signals which are collected under a fault condition at a 345[kV] transmission system modeled by EMTP-RV are used.

양릉천(陽陵泉) 고주파(高周波) 전침자극(電鍼刺戟)이 $CCl_4$로 유발된 흰 쥐의 간손상(肝損傷)에 미치는 영향(影響) (A Study on the Effect of High Frequency Electroacupuncture at Yanglingquan(GB34) on $CCl_4$-intoxicated Rats)

  • 허윤경;이현
    • Korean Journal of Acupuncture
    • /
    • 제26권1호
    • /
    • pp.111-123
    • /
    • 2009
  • Objective : The purpose of this study is to observe the effect of high frequency electro-acupuncture (hf-EA) at Yanglingquan(GB34) on $CCl_4$-induced liver damage in rats. Methods : The author performed several experimental items, including measurements of body weight and liver weight, hematological analysis for RBC, WBC, PLT, hemoglobin, lymphocytes, neutrophils, monocytes and biochemical assays for ALT, AST, ALP and total cholesterol in serum, and histological analysis of liver tissue. Results & Conclusion : 1. WBC level in blood was slightly reduced by acupuncture and hf-EA at GB34. 2. Lymphocyte level in blood was decreased by $CCl_4$-intoxication and significantly increased by acupuncture and hf-EA at GB34. 3. Neutrophils level in blood was slightly reduced by acupuncture and hf-EA at GB34. 4. ALT and AST in serum were reduced significantly by acupuncture and hf-EA at GB34. 5. The pathological changes of liver tissue induced by $CCl_4$ was reduced by hf-EA at GB34. 6. No significant difference was found between the effects of acupuncture and hf-EA on CCl4-induced liver damage in rats.

  • PDF

잠자리 유형 날개의 비정상 양력 측정 (Unsteady Lift Measurements of the Dragonfly-type Wing)

  • 김송학;장조원
    • 한국항공운항학회지
    • /
    • 제14권2호
    • /
    • pp.1-8
    • /
    • 2006
  • Unsteady lift measurements were carried out in order to investigate the effects of phase difference and reduced frequency of a dragonfly-type model with two pairs of wing. A load-cell was employed to measure the lift generated by a plunging motion of the dragonfly-type model with the incidence angles of 0$^{circ}$. Experimental conditions are as follows: phase differences between fore- and hind-wings are 0$^{circ}$, 90$^{circ}$, 180$^{circ}$, and 270$^{circ}$, and reduced frequencies are 0.075, 0.15 and 0.225, respectively. The freestream velocity was 143 m/sec and corresponding chord Reynolds number was $3.4{\times}10^3$. The variation of phase-averaged lift coefficients during one cycle of the wing motion is presented. Results show that the total value of the positive lift coefficient during one cycle of the wing motion is the largest at the phase difference of 90$^{circ}$, and that the maximum lift coefficient and lift coefficient per unit of time increases with reduced frequency.

  • PDF

주파수영역 설계명세조건의 저차원분해를 이용한 2차원 디지털 필터의 설계 (Design of 2-D Separable Denominator Digital Filters based on the reduced Dimension Decomposition of Frequency Domain Specification)

  • 문용선
    • 한국정보통신학회논문지
    • /
    • 제5권7호
    • /
    • pp.1346-1353
    • /
    • 2001
  • 본 논문에서는 2차원 분모분리형 디지털 필터의 선계에 대한 알고리즘을 제안한다. 제안된 알고리즘은 진폭 특성과 위상특성으로 주어진 2차원 디지털 필터의 주파수 영역 설계명세조건을 특이치 분해를 이용하여 1차원 디지털 필터의 설계명세조건으로 분해한다. 따라서, 2차원 디지털 필터 설계문제는 1차원 디지털 필터의 설계 문제로 귀착되며 이는 계산적으로 유효하며 수치적으로 안정한 설계법으로 고려되며 설계 예로부터 유효성을 확인한다.

  • PDF

Recency and Frequency based Page Management on Hybrid Main Memory

  • Kim, Sungho;Kwak, Jong Wook
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권3호
    • /
    • pp.1-8
    • /
    • 2018
  • In this paper, we propose a new page replacement policy using recency and frequency on hybrid main memory. The proposal has two features. First, when a page fault occurs in the main memory, the proposal allocates it to DRAM, regardless of operation types such as read or write. The page allocated by the page fault is likely to be high probability of re-reference in the near future. Our allocation can reduce the frequency of write operations in PCM. Second, if the write operations are frequently performed on pages of PCM, the pages are migrated from PCM to DRAM. Otherwise, the pages are maintained in PCM, to reduce the number of unnecessary page migrations from PCM. In our experiments, the proposal reduced the number of page migrations from PCM about 32.12% on average and reduced the number of write operations in PCM about 44.64% on average, compared to CLOCK-DWF. Moreover, the proposal reduced the energy consumption about 15.61%, and 3.04%, compared to other page replacement policies.

진동하는 사각날개의 날개끌 와류 구조에 관한 실험적 연구 (Experimental Study on the Structure of Tip Vortex Generated by an Oscillating Rectangular Hydrofoil)

  • 현범수;김무롱
    • 대한조선학회논문집
    • /
    • 제43권1호
    • /
    • pp.59-67
    • /
    • 2006
  • Evolution of the unsteady three-dimensional tip vortex in the wake field of a rectangular NACA 0012 hydrofoil in pitching motion is investigated. Measurements were made in CWC using PIV. A hydrofoil has an aspect ratio of 5 with chord length of 1 Oem. Pitching angle and mean angle of attack were set to $\pm$ $5^{\circ}$ and $10^{\circ}$, respectively. Frequency of oscillation was varied from 0.1 Hz to 1 Hz in order to study the effect of unsteadiness imposed by various frequencies, which correspond to the reduced frequency of K=0.1, 0.21, 0.52 and 1.05. Reynolds number based on chord length and free-stream velocity was $30\times$$10^{4}$ Phase-averaging technique was employed. Unsteadiness and variation of the size and characteristics of tip vortex at different reduced frequency were discussed.

주파수 영역에서 Nyquist 선도를 이용한 모델 축소 (Model Reduction Algorithm Using Nyquist Curve in Frequency Domain)

  • 조준호;김정철;김진권;최정내;황형수
    • 제어로봇시스템학회논문지
    • /
    • 제8권6호
    • /
    • pp.439-444
    • /
    • 2002
  • In this paper, a new model reduction method is proposed to obtain a reduced order model in the frequency domain. The method is developed based on the second-order plus dead time modeling technique. The initial value of the reduced model parameters can be obtained using this method coinciding four point(0, -$\pi$/2, -$\pi$, -3$\pi$/2) on the Nyquist curve. The optimal parameters of the reduced model is obtained through calculation procedure with three steps. It is shown that Nyquist curves and unit step responses of the reduced models of numerical examples closely agree with those of original models.

크리로프 부공간법에 근거한 모델차수축소기법을 통한 배열형 MEMS 공진기의 주파수응답해석 (Frequency Response Analysis of Array-Type MEMS Resonators by Model Order Reduction Using Krylov Subspace Method)

  • 한정삼;고진환
    • 대한기계학회논문집A
    • /
    • 제33권9호
    • /
    • pp.878-885
    • /
    • 2009
  • One of important factors in designing MEMS resonators for RF filters is obtaining a desired frequency response function (FRF) within a specific frequency range of interest. Because various array-type MEMS resonators have been recently introduced to improve the filter characteristics such as bandwidth, pass-band, and shape factor, the degrees of freedom (DOF) of finite elements for their FRF calculation dramatically increases and therefore raises computational difficulties. In this paper the Krylov subspace-based model order reduction using moment-matching with non-zero expansion points is represented as a numerical solution to perform the frequency response analyses of those array-type MEMS resonators in an efficient way. By matching moments at a frequency around the specific operation range of the array-type resonators, the required FRF can be efficiently calculated regardless of their operating frequency from significantly reduced systems. In addition, because of the characteristics of the moment-matching method, a minimal order of reduced system with a prearranged accuracy can be determined through an error indicator using successive reduced models, which is very useful to automate the order reduction process and FRF calculation for structural optimization iterations. We also found out that the presented method could obtain the FRF of a $6\times6$ array-type resonator within a seventieth of the computational time necessary for the direct method and in addition FRF calculation by the mode superposition method could not even be completed because of a data overflow with a half after calculation of 9,722 eigenmodes.

A Study on the Fundamental Surge Frequencies in Multi-Stage Axial Flow Compressor Systems

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권4호
    • /
    • pp.160-173
    • /
    • 2014
  • Surge phenomena in multi-stage axial flow compressors were studied with attention to the frequency behaviors. A new parameter "volume-modified reduced surge frequency" was introduced, which took into consideration the essential surge process, i.e., emptying and filling of the working gas in the delivery plenum. The behaviors of the relative surge frequencies at the stall stagnation boundaries, compared with the corresponding duct resonance frequencies, have demonstrated the existence of two types of surges; i.e., a near-resonant surge and a subharmonic surge. The former, which has fundamentally a near-resonance frequency, occurs predominantly at the stall stagnation boundary for the short -and-fat plenum delivery flow-path and the long-and-narrow delivery duct flow-path, and possibly in the intermediate conditions. The latter, which has a subharmonic frequency of the fundamental near-resonant one and occurs mainly in the intermediate zone, is considered to be caused by the reduced frequency restricted to a limited range. In relation with those dimensionless frequencies at the stall stagnation boundary, the surge frequency behaviors in more general situations away from the boundaries could be estimated, though very roughly.

Filtered Velocity Feedback 제어기를 이용한 양단지지보의 능동진동제어 (Active Vibration Control of Clamped Beams Using Filtered Velocity Feedback Controllers)

  • 신창주;홍진숙;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제21권5호
    • /
    • pp.447-454
    • /
    • 2011
  • This paper reports a filtered velocity feedback(FVF) controller, which is an alternative to direct velocity feedback(DVFB) controller. The instability problems due to high frequency response under DVFB can be alleviated by the suggested FVF controller. The FVF controller is designed to filter out the unstable high frequency response. The FVF controller and the dynamics of clamped beams under forces and moments are first formulated. The effects of the design parameters(cut-off frequency, gain, and damping ratio) on the stability and the performance are then investigated. The cut-off frequency should be selected not to affect the system stability. The magnitude of the open loop transfer function(OLTF) at the cut-off frequency should be small. As increasing the gain of the FVF controller, the magnitude of the OLTF is increased, so that the closed loop response can be reduced more. The enhancement of the OLTF at the cut-off frequency is reduced but the phase behavior around the cut-off frequency is distorted, as the damping ratio is increased. The control performance is finally estimated for the clamped beam. More than 10 dB reductions in velocity response can be achieved at the modal frequencies from the first to eighth modes.