• 제목/요약/키워드: reduced beam section

검색결과 122건 처리시간 0.028초

IPC 거더의 연속화 설계 방안 (Design Method for Continuous IPC Girder bridges)

  • 한만엽;황의승;박준범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.1007-1012
    • /
    • 2000
  • This study is to present a design method using continuous tendons in IPC girders. Present design methods use just concrete to make continuity between girders. In these design methods cracks occur in almost every joint area of girders. This means that these girders act as simple beam instead of continuous beams. The design method which is presented here uses continuous tendons between girders. In this method the cracks could be restrained. So the girders behave as continuous beams, which this method allows the span length gets longer than simple girders and also the section height could get lower. In this way the number of piers and the weight of super structure could be reduced which means the construction cost could also be reduced.

바닥슬래브를 고려한 용접철골모멘트접합부의 내진보강 (Seismic Retrofit of Welded Steel Moment Connections Considering the Presence of Composite Floor Slabs)

  • 이철호;김성용
    • 한국강구조학회 논문집
    • /
    • 제29권1호
    • /
    • pp.25-36
    • /
    • 2017
  • 1994년 노스리지 지진 당시 발생한 용접모멘트 접합부의 취성파괴는 주로 보 하부 플랜지에서 발생하였다. 특히 국내 기존 용접철골모멘트 접합부의 경우 과다한 전단스터드 배치에 따른 의도치 않은 합성작용로 인해 지진 내습 시 보 하부 플랜지의 취성파단이 더욱 우려되는 실정이다. 본 논문에서는 합성효과로 인한 접합부 성능저하를 개선하기 위한 목적으로 중량전단탭/수평헌치/삼각헌치로 보강된 접합부 및 RBS가 도입된 접합부에 대한 실험을 실시하였다. 통상 기존 접합부 상부 플랜지의 수정이 불가하다는 점을 고려하여, 본 연구에서는 보 하부 플랜지에만 수평/삼각헌치를 보강하거나 RBS를 도입하여 이 때의 내진성능을 평가하였다. 실물대 실험 결과 수평/삼각헌치 혹은 중량전단탭으로 보강한 실험체는 모두 합성작용으로 인한 부작용을 극복하고 특수모멘트접합부가 요구하는 수준 이상의 소성회전각 5%이상을 발현함을 확인하였다. 또한 SRC 기둥에 RBS를 도입할 경우 접합부에 소요되는 변형의 대부분을 RBS측에서 일어나도록 유도함으로써 SRC기둥에 발생하는 손상을 방지하는 효과가 있음을 규명하였다. 이 중 중량전단탭 보강에 따른 접합부의 거동을 분석하기 위하여 추가의 수치해석 연구를 실시하였으며, 제시한 각각의 보강안에 대한 권장상세를 제시하였다.

SN 강재가 사용된 강구조 용접모멘트접합부의 내진성능 평가 (Evaluating Seismic Performance of Steel Welded Moment Connections Fabricated with SN Steel)

  • 오상훈;최영재;윤성기;이동규
    • 한국강구조학회 논문집
    • /
    • 제22권3호
    • /
    • pp.271-280
    • /
    • 2010
  • 본 연구에서는 국내 건축 구조용 강재인 SN490 강재를 사용하여 실물 크기의 H형강 보와 기둥으로 구성된 모멘트저항골조의 외부 T자형 용접모멘트접합부를 대상으로 실험을 계획하였다. 실험변수를 용접접근공형상, 접합부 이음 방식, RBS(Reduced Beam section)로 하여 9개의 시험체를 제작하였고, 반복재하 실물대 실험을 수행하였다. 실험에 따른 각 시험체의 파괴형태 및 모멘트-층간변위 관계, 변형률 분포를 나타내었으며, 재료인장 실험을 통하여 실험에 사용된 시험체의 전소성모멘트를 구한 다음 특수모멘트 접합부에 해당하는 시험체를 분류하였다. 각 시험체의 모멘트-층간변위 곡선을 골격곡선과 바우싱거곡선으로 분리하여 내력상승률, 소성배율, 에너지 소산량 등을 나타내었으며 이를 가지고 각 시험체의 소성변형능력을 평가하였다. 실험결과 용접접근공이 제거된 시험체가 기존 용접접근공형상을 가지는 시험체에 비하여 우수한 내진성능을 나타내었고, 보 웨브를 용접과 볼트를 병행하고 전단탭을 전체에 걸쳐 보강 용접한 시험체가 가장 우수한 내진성능을 나타내었다.

RHS 기둥-H형강보 접합부의 내진보강 설계 (Seismic Retrofit Design of RHS Column-to-H Beam Connections)

  • 김영주;오상훈
    • 한국강구조학회 논문집
    • /
    • 제20권4호
    • /
    • pp.529-537
    • /
    • 2008
  • 본 논문의 목적은 슬래브가 있는 RHS 기둥-H 형강보 접합부의 내진보강설계방법을 제안하는 것이다. 모멘트접합부의 내진보강에 관한 이전 연구를 참조하면, 보강된 RBS(SR) 또는 연장된 수평스티프너(LH)를 가진 접합부는 응력/변형도 집중의 저감에 매우 효과적인 것으로 밝혀졌다. 따라서 두개의 내진보강방법, 즉, 보강된 RBS(SR)과 연장된 수평스티프너(LH)를 사용한 새로운 설계절차를 제시하였다: 게다가 본 논문에는 접합부의 내진보강방법을 향상시키기 위한 다양한 상세 및 방법 등이 기술되었다. 끝으로 설계방법의 검증을 위해서 파일럿테스트를 실시하였다.

콘크리트충전 각형기둥-H형강보 접합부의 변형능력에 관한 실험적 연구 (Experimental Investigation on Deformation Capacity of CFT Column to H-Steel Beam Connections)

  • 김영주;채영석;신경재;오영석;문태섭
    • 한국강구조학회 논문집
    • /
    • 제16권1호통권68호
    • /
    • pp.113-121
    • /
    • 2004
  • T-스티프너로 보강한 모멘트 접합부의 실대형 실험이 수행되었다. 극심한 반복하중하에서 접합부의 변형모멘트 저항능력을 높이기 위해서 T-스티프너의 수직 및 수평요소로 보강하였다. 본 연구에서는 모두 5개의 실험체에 대한 실험을 수행하였는데, 접합부를 구성함에 있어서 CFT기둥 (${\boxe}-500{\times}500{\times}12$)과 H형강보 ($H-506{\times}201{\times}11{\times}19$)를 사용하였다. 접합부의 변형능력을 향상시키기 위해 RBS 상세(Dog-bone)와 수평요소 홀(HEH) 상세를 조합했다. 실험결과 RBS와 HEH 상세를 가진 실험체는, VE가 취성파단한 실험체를 제외하면, 모두 우수한 내진성능을 보였다. 또한, 모든 접합부의 최대내력은, 보의 실제의 항복하중을 사용한 값으로 구한 전소성모멘트를 적어도 15%에서 많게는 36%정도로 상회하였다.

선체고유횡진동해석(船體固有橫振動解析)에 있어서의 계산정도(計算精度) (On the Accuracy of Calculation in the Analysis of Natural Transverse Vibrations of a Ship's Hull)

  • 김극천;이호섭
    • 대한조선학회지
    • /
    • 제13권1호
    • /
    • pp.1-9
    • /
    • 1976
  • Using the computer programs for calculation of natural vibrations of ship's hull developed by the authors et al., an investigation into influences of various parameters on the accuracy of calculation was done through example calculations of a 30,000 DWT petroleum products carrier M/S Sweet Brier built by Korea Shipbuilding and Engineering Corporation. The methodical principles employed for the computer program development are as follows; (a) the ship system is reduced to an equivalent discrete elements system conforming to Myklestad-Prohl model, (b) the problem formulation is of transfer matrix method, and (c) to obtain solutions an extended $G\ddot{u}mbel's$ initial value method is introduced. The scope of the investigation is influences of number of discrete elements, choice of significant system parameters such as rotary inertia, bending stiffness and shear stiffness, and simplification of distributions of added mass and stiffness as trapezoidal ones referred to those of midship section on the calculation accuracy. From the investigation the followings are found out; (1) To obtain good results for the modes up to the seven-noded thirty or more divisions of the hull is desirable. For fundamental mode fifteen divisions may give fairly good results. (2) The influence of rotary inertia is negligibly small at least for the modes up to the 5- or 6- noded. (3) In the case of assuming either bending modes or shear modes the calculation results in considerably higher frequencies as compared with those based on Timoshenko beam theory. However, the calculation base on the slender beam theory surprisingly gives frequencies within 10% error for fundamental modes. (4) It is proved that to simplify distributions of added mass and stiffness as trapezoidal ones referred to those of midship section is a promising approach for the prediction of natural frequencies at preliminary design stage; provided good accumulation of data from similar type ships, we may expect to obtain natural frequencies within 5% error.

  • PDF

Load and Deflection Recovery Capacities of PSC Girder with Unbonded PS H-Type Steel

  • Kim, Jong Wook;Kim, Jang-Ho Jay;Kim, Tae-Kyun;Lee, Tae Hee;Yang, Dal Hun
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1336-1349
    • /
    • 2018
  • Generally, a precast prestressed concrete (PSC) beam is used as girders for short-to-medium span (less than 30 m) bridges due to the advantages of simple design and construction, reduction of construction budget, maintenance convenience. In order to increase the span length beyond 50 m of precast PSC girder, PSC hollow box girder with unbonded prestressed H-type steel beam placed at the compressive region is proposed. The unbonded compressive prestressing in the H-type steel beams in the girder is made to recover plastic deflection of PSC girder when the pre-stressing is released. Also, the H-steel beams allow minimization of depth-to-length ratio of the girder by reducing the compressive region of the cross-section, thereby reducing the weight of the girder. A quasi-static 3-point bending test with 4 different loading steps is performed to verify safety and plastic deflection recovery of the girder. The experimental results showed that the maximum applied load exceeded the maximum design load and most of the plastic deflection was recovered when the compressive prestressing of H-type steel beams is released. Also using prestressed H-type steel as compression reinforcements in the upper part of cross section, repair and restoration difficulty and cost of PSC girders should be significantly reduced. The study result and analysis are discussed in detail in the paper.

Ductility and strength assessment of HSC beams with varying of tensile reinforcement ratios

  • Mohammadhassani, Mohammad;Suhatril, Meldi;Shariati, Mahdi;Ghanbari, Farhad
    • Structural Engineering and Mechanics
    • /
    • 제48권6호
    • /
    • pp.833-848
    • /
    • 2013
  • Nine rectangular-section of High Strength Concrete(HSC) beams were designed and casted based on the American Concrete Institute (ACI) code provisons with varying of tensile reinforcement ratio as (${\rho}_{min}$, $0.2_{{\rho}b}$, $0.3_{{\rho}b}$, $0.4_{{\rho}b}$, $0.5_{{\rho}b}$, $0.75_{{\rho}b}$, $0.85_{{\rho}b}$, $_{{\rho}b}$, $1.2_{{\rho}b}$). Steel and concrete strains and deflections were measured at different points of the beam's length for every incremental load up to failure. The ductility ratios were calculated and the moment-curvature and load-deflection curves were drawn. The results showed that the ductility ratio reduced to less than 2 when the tensile reinforcement ratio increased to $0.5_{{\rho}b}$. Comparison of the theoretical ductility coefficient from CSA94, NZS95 and ACI with the experimental ones shows that the three mentioned codes exhibit conservative values for low reinforced HSC beams. For over-reinforced HSC beams, only the CSA94 provision is more valid. ACI bending provision is 10 percent conservative for assessing of ultimate bending moment in low-reinforced HSC section while its results are valid for over-reinforced HSC sections. The ACI code provision is non-conservative for the modulus of rupture and needs to be reviewed.

Performance of Adhesives in Glulam after Short Term Fire Exposure

  • Quiquero, Hailey;Chorlton, Bronwyn;Gales, John
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.299-311
    • /
    • 2018
  • As engineered timber such as Glulam is seeing increasing use in tall timber buildings, building codes are adapting to allow for this. In order for this material to be used confidently and safely in one of these applications, there is a need to understand the effects that fire can have on an engineered timber structural member. The post-fire resilience aspect of glulam is studied herein. Two sets of experiments are performed to consider the validity of zero strength guidance with respect to short duration fire exposure on thin glulam members. Small scale samples were heated in a cone calorimeter to different fire severities. These samples illustrated significant strength loss but high variability despite controlled quantification of char layers. Large scale samples were heated locally using a controlled fuel fire in shear and moment locations along the length of the beam respectively. Additionally, reduced cross section samples were created by mechanically carving a way an area of cross section equal to the area lost to char on the heated beams. All of the samples were then loaded to failure in four-point (laterally restrained) bending tests. The beams that have been burnt in the shear region were observed as having a reduction in strength of up to 34.5% from the control beams. These test samples displayed relatively little variability, apart from beams that displayed material defects. The suite of testing indicated that zero strength guidance may be under conservative and may require increasing from 7 mm up to as much as 23 mm.

Growth of GaAs by Chemical Beam Epitaxy Using Unprecracked Arsine and Trimethylgallium

  • Park, Seong-Ju;Ro, Jeong-Rae;Sim, Jae-Ki;Lee, El-Hang
    • ETRI Journal
    • /
    • 제16권3호
    • /
    • pp.1-10
    • /
    • 1994
  • Undoped GaAs has been successfully grown by chemical beam epitaxy (CBE) via surface decomposition process using arsine $(AsH_3)$ and trimethylgallium (TMG). Three distinct regions of temperature-dependent growth rates were identified in the range of temperatures from 570 to $690^{\circ}C$. The growth rates were found strongly dependent on the V/III ratio between 5 and 30. The growth rate at low V/III ratio seems to be determined by arsenic produced on the surface, whereas at high V/III ratio it shows dependence on the adsorption of TMG. Hall measurement and photoluminescence (PL) analysis show that the films are all p-type and that carbon impurities are primarily responsible for the background doping. Carbon concentrations have been found to be reduced by two orders of magnitude as compared to those of epilayers grown by CBE which employs TMG and arsenic obtained from precracked $AsH_3$ in a high temperature cell. It was also found that hydrogen atoms dissociated from unprecracked $AsH_3$ play an important role in removing hydrocarbon-containing species resulting in a significant reduction of car-bon impurities.

  • PDF