• Title/Summary/Keyword: rectangular membrane module

Search Result 6, Processing Time 0.016 seconds

Dialysis in double-pass cross-flow rectangular membrane modules with external recycle for improved performance

  • Yeh, Ho-Ming
    • Membrane and Water Treatment
    • /
    • v.2 no.2
    • /
    • pp.75-89
    • /
    • 2011
  • The predicting equations for mass transfer rate in cross-flow rectangular dialyzers with double flow and recycle, have been derived by mass balances. The recycling operation has two conflicting effects. One is the desirable effect of the increase in fluid velocity, resulting in an increased mass transfer coefficient. The other is the undesirable effect of the reduction in concentration difference due to remixing, resulting in decreased mass-transfer driving force. In contrast a single-pass device without recycling, considerable improvement in mass transfer is achieved if the cross-flow rectangular dialyzer of same size is operated with double pass and external recycling. It is concluded that recycle can enhance mass transfer, especially for larger reflux ratio.

Dialysis with ultrafiltration through countercurrently parallel-flow membrane modules

  • Yeh, Ho-Ming;Chen, Chien-Yu
    • Membrane and Water Treatment
    • /
    • v.4 no.3
    • /
    • pp.191-202
    • /
    • 2013
  • The application of ultrafiltration operation to the dialysis in countercurrently parallel-flow rectangular membrane modules was investigated. The assumption of uniform ultrafiltration flux was made for operation with slight concentration polarization and declination of transmembrane pressure. Considerable improvement in mass transfer is achievable if the operation of ultrafiltration is applied, especially for the system with low mass transfer coefficient. The enhancement in separation efficiency is significantly increased with increasing ultrafiltration flux, as well as with increasing the volumetric flow rates. Furthermore, increasing the volumetric flow rate in retentate phase is more beneficial to mass transfer than increasing in dialysate phase.

Mass transfer in cross-flow dialyzer with internal recycle

  • Yeh, Ho-Ming;Chen, Chien-Yu
    • Membrane and Water Treatment
    • /
    • v.4 no.4
    • /
    • pp.251-263
    • /
    • 2013
  • The internal reflux effect on dialysis through the retentate phase of a countercurrently cross-flow rectangular module is investigated. Theoretical analysis of mass transfer in cross-flow devices with or without recycling is analogous to heat transfer in cross-flow heat exchangers. In contrast to a device without reflux, considerable mass transfer is achievable if cross-flow dialyzers are operated with reflux, which provides an increase in fluid velocity, resulting in a reduction in mass-transfer resistance. It is concluded that reflux can enhance mass transfer, especially for large flow rate and feed-concentration operated under high reflux ratio.

The Capacitive Deionization Module Design and Its Analysis by Computational Flow Dynamics (CDI 모듈 설계와 전산유동해석)

  • Nam, Ki Jin;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.29 no.5
    • /
    • pp.284-291
    • /
    • 2019
  • In this study, for the improvement of flow pattern with the CDI module that had the larger electrodes, it was designed with the rectangular type which is gradually wider from the inlet. Based on this, both the flow pattern of feed solution and dead zone were observed and the internal pressure, streaming line and velocity vector distribution were analyzed through the computational flow dynamics and compared with the experimental results. For all flow rates of 10, 20, 30 mL/min, there were no dead zones and the flow patterns were maintained constant. Therefore, it may be possible that the larger electrodes are applied to the CDI process.

CFD simulations of the fluid flow behavior in a spacer-filled membrane module

  • Jun, Chen L.;Xiang, Jia Y.;Dong, Hu Y.
    • Membrane and Water Treatment
    • /
    • v.6 no.6
    • /
    • pp.513-524
    • /
    • 2015
  • In this study, the effects of the angles of spacer filaments and the different feed Reynolds number on the fluid flow behavior have been investigated. Three-dimensional computational fluid dynamics (CFD) study is carried out for fluid flow through rectangular channels within different angles ($30^{\circ}$, $40^{\circ}$, $50^{\circ}$, $60^{\circ}$, $70^{\circ}$, $80^{\circ}$, $90^{\circ}$, $100^{\circ}$, $110^{\circ}$, $120^{\circ}$, respectively) between two filaments of spacer for membrane modules. The results show that the feed Reynolds number and the angles of spacer filaments have an important influence on pressure drop. While the feed Reynolds number is fixed, the optimal angle of spacer should be between $80^{\circ}$ to $90^{\circ}$, because the pressure drop is not only relatively small, but also high flow rate region expanded significantly with the increase of the angles between $80^{\circ}$ to $90^{\circ}$.The Contours of velocities and change of the average shear stress with the different angle of spacer filaments confirm the conclusion.

Structural Design for Key Dimensions of Printed Circuit Heat Exchanger (인쇄기판형열교환기 핵심치수 구조설계)

  • Kim, Yong Wan;Kang, Ji Ho;Sah, In Jin;Kim, Eung Seon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.14 no.1
    • /
    • pp.24-31
    • /
    • 2018
  • The mechanical design procedure is studied for the PCHE(printed circuit heat exchanger) with electrochemical etched flow channels. The effective heat transfer plates of PCHE are assembled by diffusion bonding to make a module. PCHE is widely used for industrial applications due to its compactness, cost efficiency, and serviceability at high pressure and/or temperature conditions. The limitations and technical barriers of PCHE are investigated for application to nuclear components. Rules for design and fabrication of PCHE are specified in ASME Section VIII but not in ASME Section III of nuclear components. Therefore, the calculation procedure of key dimensions of PCHE is defined based on ASME section VIII. The effective heat transfer region of PCHE is defined by several key dimensions such as the flow channel radius, edge width, wall thickness, and ridge width. The mechanical design procedure of key dimensions was incorporated into a program for easy use in the PCHE design. The effect of assumptions used in the key dimension calculation on stress values is numerically investigated. A comparative analysis is done by comparing finite element analysis results for the semi-circular flow channels with the formula based sizing calculation assuming rectangular cross sections.