• 제목/요약/키워드: recovery efficiency

검색결과 1,353건 처리시간 0.031초

공동주택용 폐열회수형 환기장치의 성능에 관한 측정 연구 (A Study on the Performance of Heat Recovery Ventilators for Apartment Houses)

  • 장현재;홍석진
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.26-34
    • /
    • 2008
  • Heat recovery ventilator(HRV) is recommended to improve indoor air quarlity (IAQ) and energy conservation in apartment houses. Recently, in Korea, HRV is produced from many manufacturers. However, there have been not so many experiences to apply HRV in apartment houses and verification on the performance such as heat exchange efficiency, carry-over rate, internal leakage, etc. have not been carried out sufficiently. So in this study, fan performance, heat exchange efficiency, air leakage, internal exhaust leakage, external leakage and sound level of HRV were examined for selected HRV models under domestic and international standard. Results of performance test, there were need to improve latent heat exchange efficiency and sound level of HRV.

활성탄관에 포집된 극성유기용제의 탈착효율에 관한 연구 (A Study on Desorption Efficiency for Polar Solvents Collected on Charcoal Tube)

  • 김경란;백남원
    • 한국산업보건학회지
    • /
    • 제5권1호
    • /
    • pp.104-118
    • /
    • 1995
  • This study was performed to evaluate factors affecting desorption of organic solvents collected on charcoal tube and to find out the optimum condition. Desorption efficiency for polar analytes was improved when several polar desorption solvents such as methanol, dimethylformamide(DMF), 2-(2-butoxyethoxy)ethanol were added to carbon disulfide($CS_2$). The best improvement was achieved when 10% dimethylformamide(DMF) in $CS_2$ was used as desorption solvent. During storage of polar analytes, recovery was greatly reduced. Especially, the recovery of cyclohexanone was decreased to 18.1 % after a month storage at $34^{\circ}C$. After two weeks storage, recovery of polar analytes was sharply decreased. Water adsorbed on charcoal interfered the recovery of polar analytes but didn't interfere that one of nonpolar solvent, toluene. When 10% DMF in $CS_2$ was used as desorption solvent, the effect of water on recovery was decreased, comparing with Desorption efficiency increased when analyte loading increased, and usage of 10% DMF in $CS_2$ decreased the loading effect. Increasing volume of desorption solvent was not effective to improve desorption efficiency of analytes when 10% DMF was used. Continuous shaking and sonication is not helpful to increase the desorption efficiency of analytes except cyclohexanone using 10% DMF. When silica gel used as adsorbent, methanol was better desorbent than dimethylsulfoxide. Analytes adsorbed on silica gel showed high recovery in low concentration and less affected by humidity. On the basis of this study, the following conclusions have been drawn. To improve the recovery of polar organic materials in air samples, it is necessary to analyze samples as soon as possible after they were collected. Otherwise, samples must be stored at low temperature. Using two components of desorption solvents, such as 10% DMF in $CS_2$, the effects of loading and humidity decreased for polar analytes such as methyl ethyl ketone and methyl isobutyl ketone. When work place has high humidity with low concentration of polar organic solvents, silica gel can be used as adsorbent, because it produces quantitative recovery for polar analytes at this condition. But it should be noted that high humidity makes breakthrough easy in silica gel samples.

  • PDF

벽체매립형 폐열회수 환기시스템의 열회수 성능 향상에 관한 실험적 연구 (An Experimental Study on Performance Improvement for Exhaust Heat Recovery Ventilation System in a Lightweight Wall)

  • 정민호;오병길
    • 설비공학논문집
    • /
    • 제26권2호
    • /
    • pp.61-66
    • /
    • 2014
  • Exhaust heat recovery ventilation systems conserve energy through enthalpy recovery between air intake and exhaust, and they are being increasingly used. An exhaust heat recovery ventilation system can be installed in the ceiling of a balcony or emergency evacuation space. However, in the case of fire, the emergency evacuation space has to by law remain as empty space, and therefore, a ventilation system can't be installed in an emergency evacuation space. Therefore, the need for a proper installation space for a ventilation system is emphasized. In this study, to install a heat recovery ventilation system in a lightweight wall, a heat exchanger was assembled of thickness below 140 mm. The efficiency of heat recovery was analyzed through performance experiment, in the case of the cooling and heating mode. The heat recovery efficiency increases when the surface area is increased, by using closer channel spacing in the heat exchanger, or by increasing the size of the heat exchanger.

분리벽형 증류탑을 적용한 필름공정의 폐용매 회수공정 최적설계 (Optimal Design of Solvent Recovery Process with Dividing Wall Column for Film Making Process)

  • 이승현;조문신;이문용
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1209-1214
    • /
    • 2006
  • This paper presents an application of Dividing Wall Column(DWC) to the recovery of the waste solvent from the film making processes. The waste solvent feed contains MEK(Methyl-Ethyl-Ketone), Toluene, Cyclohexanone, and water. The commercial software $HYSYS^{TM}$ was used for rigorous simulation and analysis. Sensitivity analysis for several major design variables were carried out to achieve the optimal design of the process. Distribution of the internal vapor and liquid flows to the prefractionator and main sections is shown to be the most dominant design factor for energy saving efficiency in the DWC process. The simulation results also show that the solvent recovery process using the DWC significantly improves both the energy efficiency and the compactness of the solvent recovery process.

응축수 순환이 폐열회수 응축형 보일러 성능에 미치는 영향 (Effect of Waste Heat Recovery Condensing Boiler with Condensed Water Recirculation Function)

  • 금국빈;김수익;유병훈;이창언
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.201-204
    • /
    • 2015
  • Recently, energy excessive consumption and environmental pollution are the social issued. The most efficient way to solve both energy excessive consumption and environmental pollution is existing combustion system improved. This study was part of the assume and commercial used existing waste heat recovery condensing boiler to low emission performance for exhaust gas recirculation(EGR) and thermal efficiency rise by applying the condensed water recirculation(CWR) conducted. The researchers applied the EGR and CWR develop a new concept for the condensed water recirculation waste heat recovery condensing boiler. Waste heat recovery condensing boiler applied to the condensed water recirculation thermal efficiency of the same conditions was increased by about 4.8~5.5% and pollution emission also decreased.

  • PDF

생활폐기물 소각시설의 운영 실태 분석을 통한 에너지회수 효율 개선방안 검토 (A Study on Improvement Measures of Energy Recovery Efficiency through Analysis of Operational Status of Municipal Solid Waste Incineration Facilities)

  • 박상진;배재근
    • 한국폐기물자원순환학회지
    • /
    • 제35권8호
    • /
    • pp.762-769
    • /
    • 2018
  • This study was carried out to examine the improvement plan by analyzing the characteristics of imported wastes, operation rate, and benefits of energy recovery for incineration facilities with a treatment capacity greater than 50 ton/day. The incineration facility capacity increased by 3,280 tons over 15 years, and the actual incineration rate increased to 2,783 ton/day. The operation rate dropped to 76% in 2010 and then rose again to 81% in 2016. The actual calorific value compared to the design calorific value increased by 33.8% from 94.6% in 2002 to 128.4% in 2016. The recovery efficiency decreased by 29% over 16 years from 110.7% to 81.7% in 2002. Recovery and sales of thermal energy from the incinerator (capacity 200 ton/day) dominated the operation cost, and operating income was generated by energy sales (such as power generation and steam). The treatment capacity increased by 11% to 18% after the recalculation of the incineration capacity and has remained consistently above 90% in most facilities to date. In order to solve the problem of high calorific value waste, wastewater, leachate, and clean water should be mixed and incinerated, and heat recovery should be performed through a water-cooled grate and water cooling wall installation. Twenty-five of the 38 incineration facilities (about 70%) are due for a major repair. After the main repair of the facility, the operation rate is expected to increase and the operating cost is expected to decline due to energy recovery. Inspection and repair should be carried out in a timely manner to increase incineration and heat energy recovery efficiencies.

잠수공(潛水孔) 수로를 가진 유회수기 개발 (Development of Oil Skimmer with Submerged Orifice)

  • 고흥
    • 대한기계학회논문집B
    • /
    • 제34권5호
    • /
    • pp.457-464
    • /
    • 2010
  • 사고로 해양에 유입된 기름을 제거하는 대표적인 방법은 기계적 회수, 화학적인 처리, 수면소각, 미생물에 의한 분해 등이 있으나, 2차오염의 가능성을 방지할 수 있는 기계적인 회수법이 최상으로 생각된다. 기계적 유회수 형태는 벨트, 디스크, Weir, Vortex, 흡입, 드럼, 브러쉬 방식 등이 있다. 저자는 합목적적인 방법으로 회수능력을 개선할 수 있는 실험을 위한 잠수공 모델을 만들었다. 본 스키머의 원리는 외부 액체(물과 기름)를 스키머에 유입시키면, 비중 차에 의해 기름은 뜨고 물은 가라앉는 것이다. 본 스키머는 탱크 바닥의 잠수공으로 물은 빠져나가 스키머 내에 물은 최소로 남고 기름은 모아 회수하는 위어타입의 혁신적인 것이다. 유회수량과 유회수율을 결과로 보였다. 유회수율은 1차 집유탱크의 기름층이 두꺼워지면 증가한다.

실증운전을 통한 배가스 열회수 히트펌프 시스템의 성능 분석 (Analysis of Performance of Heat Pump System with Flue Gas Heat Recovery through Field Test)

  • 이승호;이길봉;이영수;박상일;고창복;백영진;이관수
    • 설비공학논문집
    • /
    • 제26권1호
    • /
    • pp.1-7
    • /
    • 2014
  • A field test of a 70 kW heat pump system with flue gas heat recovery was performed by an experiment at the Korea Institute of Energy Research. The flue gas is exhausted from a 320 RT absorption chiller-heater in the heating season. Using this flue gas, source water of the heat pump is heated by a condensed-type heat exchanger in the chimney. The operating characteristics of the heat recovery heat pump system were analyzed. Based on the results of the experiments, operating maps were obtained, and an optimum operating range is suggested, in which the return and heat source water temperature are $51^{\circ}C$ and $31^{\circ}C$, respectively. Additionally, economic analysis of this system was conducted and about 50% energy cost savings can be expected in the heating season.

5톤/일 규모의 연소보일러에서 Bio-drying 고형연료의 연소특성 연구 (A Study on Combustion Characteristics of the Bio-drying SRF in 5 Ton/day Scale Combustion Boiler)

  • 김동주;윤영식;정법묵;박영수;서용칠;이병선
    • 한국폐기물자원순환학회지
    • /
    • 제35권7호
    • /
    • pp.600-605
    • /
    • 2018
  • In this study, the combustion characteristics were investigated based on the biodrying solid recovered fuel (SRF) in a 5 Ton/day scale combustion boiler. The composition of the combustion gas containing the biodrying SRF was analyzed, the particulate matter, and its HCl content was determined with the air pollutant process test method. Mass balance, carbon balance, and combustion efficiency were calculated according to the equivalence ratio (ER) method; the energy recovery efficiency of the combustion boiler was also analyzed. The overall combustion efficiency of the biodrying SRF was 97.3 % and the energy recovery efficiency was 80.2%.

플라이백 컨버터에서 누설인덕턴스 저장에너지의 새로운 회복회로 (A Novel Recovery Circuit of a Leakage Inductance Stored Energy in Flyback Converter)

  • 정용채
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.526-528
    • /
    • 2005
  • Nowadays, more than ever before, many researchers are paying attention to raising the efficiency of a Power converter. In Flyback converter, the resistor of RCD snubber consumes the stored energy in leakage inductor. It play a role in degrading the overall system efficiency Thus, In this paper, a novel energy recovery circuit of Flyback converter is proposed to improve the efficiency. The operational principle of the proposed circuit is explained in detail. And, it is verified through the simulation results.

  • PDF