• Title/Summary/Keyword: recording

Search Result 3,400, Processing Time 0.033 seconds

Laryngeal Evoked Electromyography with a Noninvasive Technique (비침습적 방법에 의한 후두유발근전도 검사)

  • 정성민;조선희;박기덕
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.1
    • /
    • pp.30-36
    • /
    • 1999
  • Background and Objectives : Laryngeal Evoked Electromyography(EEMG) is a objective, quantitative technique to determine innervation status of larynx. The possible applications of this technique are to confirm the etiology of impaired vocal fold motion and monitor perioperative vagus nerve trauma. The purpose of this study is to develop a novel method for determining the amount of reinnervation of recurrent laryngeal nerve with accurate, inexpensive, and minimally invasive technique in human. Materials and Methods : Laryngeal EEMG was performed for 16 adults with intact vocal folds motion and 2 patients diagnosed as unilateral vocal fold paralysis. for the purpose of searching what is the optimal and noninvasive technique for laryngeal EEMG, we used 2 types of stimulation configurations(transcutaneous vs percutaneous) and 2 types of recording configurations(intramuscular vs. surface). Results and Conclusions : Percutaneous needle stimulation and surface recording of laryngeal EEMG was reliable and comparable to standard needle stimulation and invasive intramuscular needle recording. But the laryngeal EEMG by the surface recording and transcutaneous surface stimulation was not reliable and repeatable. Therefore we recommended that laryngeal EEMG by surface recording and percutaneous needle stimulation would be minimally invasive, reliable technique to know the status of reinnervation in e patients with vocal fold paralysis.

  • PDF

Development and application of the intraoral tracer for the record of centric relation (중심위 채득을 위한 구내묘기장치의 개발과 응용)

  • Kwag, Heung Koo;Jeong, Soeg-Cho;Kang, Dong Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.37-49
    • /
    • 2000
  • It was clinically important to substitute the physiologic centric relation to the therapeutic position of the patients who needed the oral rehabilitation or occlusal treatment. There were several methods for recording the centric relation. One of the known methods was to use the gothic arch tracer. However the existing intraoral device was difficult to adjust the three dimensional angulation of the recording plate and recording stylus depending on the hinge movement arch of the individual. The purpose of this study was to develop new intraoral tracer which had adjustable stylus within hinge movement arch for the record of centric relation and to evaluate the clinical application of this device. The results were as follow; 1. A stylus of new developed intraoral tracer was so adjustable that the recording of mandibular positions could be reproducible within the hinge movement arc. 2. A record plate of new developed intraoral tracer was so adjustable to parallel with the occlusal plane that lateral recording of mandibular position was able to obtain stably. This study showed that new developed intraoral tracer allowed the determination of the treatment position which can be used in the full mouth rehabilitation and occlusal treatments.

  • PDF

Micromagnetic Computer Simulation of Ultra-high density Recording with the Use of a Planar-type Head

  • S.H. Lim;Kim, H.J.
    • Journal of Magnetics
    • /
    • v.6 no.4
    • /
    • pp.109-118
    • /
    • 2001
  • A computer simulation, utilizing the Landau-Lifshitz-Gilbert equation, of ultra-high- density recording on continuous longitudinal media is carried out. The two important features of this work are the use of a planar-type head, which enables a high write field of 14183 Oe ts be generated at the center of the recording medium, and the media with very high coercivities up to 13010 Oe. From a systematic investigation, it is found that the optimum write field is higher than the medium coercivity by only 3400 Oe over a wide coercivity range. This new finding allows one to write an a medium with a very high coercivity by using a planar-type head. It is demonstrated that a reasonably good bit pattern with a bit density of 605 kfci is generated on the medium with a coercivity of l1720 Oe, and, combined with a high track pitch density of 100 ktpi, a recording density of 60 Gb/in$^2$can be obtained in a single layer medium. With an improved write- head designs even a higher recording density of 75 Gb/in$^2$may be possible since comparison of the results for the bit pattern from the present head profile and the ideal Lindholm profile indicates an increase in the track pitch density of about 27%. Even at this density, the thermal stability parameter (KV/kT) at room temperature is high enough (60) to provide ample room for thermal stability.

  • PDF

Effects on Knowledge and Performance in Clinical Nursing of Education on Nursing Recording Focusing on Legal Aspects (법적인 측면에서의 간호기록 작성방법 교육이 임상간호사의 간호기록작성 지식과 이행에 미치는 효과)

  • Kim, Eun-Young;Yi, Yeo-Jin
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.17 no.3
    • /
    • pp.277-283
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the effects on knowledge and performance in clinical nurses who participated in education on nursing recording focusing on the legal aspects. Method: The participants were working in medical departments in one hospital. There were 32 nurses in the experimental group and 25 in the control group. Pre-test was conducted on the two groups before education, and, in order to examine the effects of education, a post-test was conducted after three weeks. For the experimental group, the education on nursing recording focusing on legal aspects was provided as a lecture-led one-to-one training. Results: Significant differences were found between the experimental and control groups in knowledge (F=15.728, p<.001), and performance (F=42.454, p<.001). Conclusions: The results of this study indicate that education on nurse recording enhances the knowledge and performance of the nurses. Thus education on nurse recording focusing on legal aspects should be required in the area of nursing science.

Effective Interdiffusion of Co/Pd multilayers

  • Kim, Jai-Young;Jan E. Evetts
    • Journal of Magnetics
    • /
    • v.2 no.3
    • /
    • pp.86-92
    • /
    • 1997
  • An artificially modulated magnetic Co/Pd multilayer is one of the promising candidates for high density magneto-optic (MO) recording media in the wavelength of a blue laser beam, due to large Kerr rotation angle. However, since the Co/Pd multilayer is a non-equilibrium state in terms of free energy and MO recording is a kind of thermal recording which is conducted around Curie temperature (Tc) of the recording media, the assessment of the thermal stability in the Co/Pd multilayer is crucially important both for basic research and applications. As the parameter of the thermal stability in this research, effective interdiffusion coefficients (Deff) perpendicular to the interface of the Co/Pd multilayers are measured in terms of Ar sputtering pressure and heat treatment temperature. From the results of the research, we find out that the magnetic exchange energy between Co and Pd sublayers strongly affects Deff of the Co/Pd multilayers. This discovery will provide the understanding of the magnetic exchange energy in the effective interdiffusion process of a magnetic multilayer structure and suggest the operating temperature range for MO recording in the Co/Pd multilayer for the basic research and applications, respectively.

  • PDF

The Study of Data Recorder for Mission Replay (임무 재생을 위한 데이터기록장치 연구)

  • Lee, Sang-Myung;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.357-360
    • /
    • 2011
  • On the matter in line with NCW(Network Centric Warfare) and information age, the military is on an efficient-expanding trend as sharing with status and information promptly through the various and complex exchange of messages and the phone communication between operators, using a highly efficient operating console. The recording devices that record an operational situation to plan a new operation through the mission analysis and result reviews after finishing military operation or training are developed and operated. Recording method is classified into two groups. one is the recording of display shots, another is the recording of an exchange of messages. This study proposes the new data-oriented recording method to reduce the readiness time of replay and the improvement scheme.

  • PDF

A Fundamental Study Architectural planning of the Medial Recording Department in Hospital (병원 의무기록부의 건축계획을 위한 기초적 연구)

  • Ryu, Jai-Kown;Lee, Nak-Woon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.1 no.2
    • /
    • pp.29-37
    • /
    • 1996
  • It is an important to notice that the the importance of the medical recording department in hospital will be increased in the future. Therefore, this study aims to analyze the organization of space and to seize the computerization of medical record system in hospital. For these purposes, the operation of medical recording department and the delivery of the patieent's medical recard paper were investigated.

  • PDF

Robustness of Bimodal Speech Recognition on Degradation of Lip Parameter Estimation Performance (음성인식에서 입술 파라미터 열화에 따른 견인성 연구)

  • Kim, Jin-Young;Min, So-Hee;Choi, Seung-Ho
    • Speech Sciences
    • /
    • v.10 no.2
    • /
    • pp.27-33
    • /
    • 2003
  • Bimodal speech recognition based on lip reading has been studied as a representative method of speech recognition under noisy environments. There are three integration methods of speech and lip modalities as like direct identification, separate identification and dominant recording. In this paper we evaluate the robustness of lip reading methods under the assumption that lip parameters are estimated with errors. We show that the dominant recording approach is more robust than other methods through lip reading experiments.

  • PDF