• Title/Summary/Keyword: rebar type

Search Result 120, Processing Time 0.03 seconds

The Development of Repair System for RC Members with Damaged by Rebar Corrosion Using Inhibitor with High Nitrite Content (아초산계 방청제 도포에 의한 철근 부식 보수 시스템 공법 개발)

  • 이한승;나정일;박순만
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.359-364
    • /
    • 2001
  • The purpose of this study is to develop the repair system for RC members with damaged by rebar corrosion using new corrosion inhibitor which was high nitrite content. In the experiments, the acceleration corrosion test of rebar was conducted using the specimen which was applied by various repair system. As a result, it was confirmed that the new repair system without concrete patching had high anti-corrosion property compared with other repair systems and was very effective as a spray type corrosion inhibitor in concrete containing chloride (0.1% of NaCl).

  • PDF

Standardization of rebar manufacturing for rebar work (철근 공사에 있어서 철근 가공 표준화)

  • Cho, Young-Keun;Jung, Sang-Hwa
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.6
    • /
    • pp.58-66
    • /
    • 2009
  • Due to a shortage of professional labor and the stagnant construction industry in recent days, there has been an increasing demand for securing profitability through cost reduction. Though its importance in the cost and its great influence on the safety and durability of structures, the labor intensiveness of rebar work has caused a serious problem of rising cost accompanied by the loss of rebar materials. In the plant manufacturing process, rebar is cut and bent at the automated facilities and conveyed to the construction site, which makes it possible to manufacture higher-quality bars and to reduce the losses from rebar materials. Different from the expectation, however, this type of plant manufacturing still has not been active since its first introduction in 1990s. In this study, a research on the actual condition of rebar manufacturing plant has been implemented and a standardized rebar manufacturing has been provided as a way to activate rebar manufacturing.

Shear Strength of Concrete Deep Beam Reinforced AFRP rebar (AFRP rebar로 보강된 콘크리트 깊은보의 전단강도)

  • Lee, Young-Hak;Kim, Min-Sook;Cho, Jang-Se;Kim, Hee-Cheul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.6
    • /
    • pp.1-9
    • /
    • 2009
  • This study carried out a shear experiment on concrete deep beam reinforced AFRP to investigate the shear strength of deep beam. The test was conducted on 8 specimens, and the variables were shear span ratio, reinforcement ratio, effective depth, and rebar type. We compared shear strength using ACI 318-08 STM with proposed equations that considered arching action according to shear span ratio. As a result, it was found that shear strength of deep beam reinforced AFRP rebar presented higher shear strength than steel rebar. ACI STM's predictions are more accurate than other predicting equations, and thus this research proposed model versus effective compressive strength of the concrete strut that considered strut size effect based on test results. The predictions obtained using the proposed model are in better agreement than previous equations and codes.

An Efficient Algorithm for Rebar Element Generation Using 3D CAD Data (3D CAD 데이터 기반의 효율적 철근 요소 생성 알고리즘)

  • Cho, Kyung-Jin;Lee, Jee-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.5
    • /
    • pp.475-485
    • /
    • 2009
  • In this paper a two-step algorithm is proposed to efficiently generate rebar elements from 3D CAD data in the context of CAD/CAE data transfer. The first step is an algorithm to identify various type rebar objects and their attributes by analyzing 3D CAD data in STEP format, which is one of the international data standards. The second algorithmic step is a procedure to generate one-dimensional rebar elements from the object data made through the first step for finite element analysis or other CAE tasks. Successful rebar element data generation from real 3D CAD data for a reinforced concrete structure shows the efficacy of the proposed algorithm.

Numerical simulation approach for structural capacity of corroded reinforced concrete bridge

  • Zhou, Xuhong;Tu, Xi;Chen, Airong;Wang, Yuqian
    • Advances in concrete construction
    • /
    • v.7 no.1
    • /
    • pp.11-22
    • /
    • 2019
  • A comprehensive assessing approach for durability of reinforced concrete structures dealing with the corrosion process of rebar subjected to the attack of aggressive agent from environment was proposed in this paper. Corrosion of rebar was suggested in the form of combination of global corrosion and pitting. Firstly, for the purposed of considering the influence of rebar's radius, a type of Plane Corrosion Model (PCM) based on uniform corrosion of rebar was introduced. By means of FE simulation approach, global corrosion process of rebar regarding PCM and LCM (Linear Corrosion Model) was regressed and compared according to the data from Laboratoire $Mat{\acute{e}}riaux$ et $Durabilit{\acute{e}}$ des Constructions (LMDC). Secondly, pitting factor model of rebar in general descend law with corrosion degree was introduced in terms of existing experimental data. Finally, with the comprehensive numerical simulation, the durability of an existing arch bridge was studied in depth in deterministic way, including diffusion process and sectional strength of typical cross section of arch, crossbeam and deck slab. Evolution of structural capacity considering life-cycle rehabilitation strategy indicated the degradation law of durability of reinforced arch bridges.

An Analytic Study of Composite Hollow Core Slab Subjected with Box Type Beams (박스형 철골빔이 적용된 프리스트레스 할로우-코어 합성슬래브의 해석연구)

  • Hong, Sung-Gul;Seo, Do-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.311-314
    • /
    • 2005
  • This research aims to analyze of prestressed composite hollow-core slab and box type steel beam. The smeared crack model used in abaqus for the modeling of hollow core reinforced concrete, including cracking of the concrete, rebar and concrete interaction using the tension stiffening concept, and rebar yield. The structure modeled is a simply supported hollow core spancrete slab subjected spa-h beams and prestressed in one direction. The hollow core spancrete slab is subjected to four-point bending. The concrete-rebar interaction that occur as the concrete begins to crack are of major importance in determining the spancrete slab's response between its initial, deformation and its collapse. This smeared crack model used in analysis involved non-liner concrete analysis concept.

  • PDF

Connection Method of Composite Precast Concrete Columns Using Thread Rebar (나사형 철근을 사용한 합성 PC기둥의 접합방법)

  • Kim, Tae-Koo;Lee, Sung-Ho;Kim, Sun-Kuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.14-15
    • /
    • 2013
  • Green Frame is precast concrete column-beam structure. There are three types on column connection. The coupler type which is one of the three, need to be improved because of unstability caused by pre-installation of column before casting the slab, and quality deterioration caused by lack of workspace. Therefore, in this study, new coupler connection type with thread rebar is suggested. The result of this study shall be used for the efficiency analysis of the new coupler connection.

  • PDF

Comtribution of surface deformations of GFRP rebar to bond to Concrete (GFRP 보강근 표면이형의 부착성능 기여도에 대한 고찰)

  • Moon, Do-Young;Sim, Jong-Sung;Oh, Hong-Seob;Sim, Jun-Gee;Kim, Jin-Gyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.19-20
    • /
    • 2009
  • Bond of deformed type of GFRP rebar, which has deformations resembles that of ordinary steel rebar, to concrete was investigated experimentally and numerically in this paper. Due to the lower stiffness and strength in shear, surface deformations do not fully works in bond with surrounding concrete. In this paper, the effective surface deformation height of GFRP rebar with ribs was determined based on experimental and numerical results.

  • PDF

Corrosion Monitoring Technology of Rebar in Reinforced Concrete Structures (철근콘크리트 구조물의 철근부식 모니터링 기술)

  • Kwon, Seong-Junn;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.258-259
    • /
    • 2019
  • Corrosion of rebar in RC structures, which results in premature deterioration of reinforced concrete structures, is a very serious problem. Most corrosion monitoring and sensing technologies require some type of wired or wireless connection between the sensor and monitoring electronics. This causes significant problems in their installation and long-term use. In this paper we describe a corrosion monitoring technology of rebar in reinforced concrete structures. Especially, it is emphasize that the development of sensors and monitoring system not only occurrence of rebar corrosion but also penetration of deterioration factor such like chloride ion and carbon dioxite etc..

  • PDF

Mix Design Conditions at Early Curing Age of PCS-Coating Material Effected on Improvement in Bond Strength of Coated Rebar (도장철근의 부착강도 개선에 영향을 미치는 초기재령에서의 PCS 도장재 배합조건)

  • Jo, Young-Kug;Park, Dong-Yeol;Kim, Wan-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.73-80
    • /
    • 2013
  • Polymer cement slurry (PCS) made from organic polymer dispersion and cement has good adhesion to steel, waterproofness and acid resistance due to being of polymer films formed in cement slurry. The purpose of this study is to evaluate the mix design conditions at early curing age of PCS-coating material effected on improvement in bond strength of coated rebar. The test pieces are prepared with two types of polymer dispersions such as St/BA and EVA, four polymer-cement ratios, two types of cement, four coating thicknesses and three curing ages, and tested for the bond strength test. From the test results, in general, bond strength of PCS-coated rebar is better than that of uncoated rebar and epoxy-coated rebar. It is also high bond strength at curing ages of 7-day or less, and coating thicknesses of $75{\mu}m$ and $100{\mu}m$. The maximum bond strength of PCS-coated rebar at curing age of 3-hour is almost same as that of curing age of 1-day and 7-day. The maximum bond strength of PCS-coated rebar with ultra high-early strength cement and St/BA at polymer-cement ratio of 80%, and coating thickness of $100{\mu}m$ is about 1.52 and 1.58 times respectively, the strength of uncoated rebar and epoxy-coated rebar. It is apparent that the curing age, coating thickness, type of polymer and cement are very important factors to improve the bond strength of PCS-coated rebar to cement concrete. We can have basic information that PCS-coated rebar with curing age at 3-hour and coating thickness of $100{\mu}m$ can replace epoxy-coated rebar.