• 제목/요약/키워드: reactive power

검색결과 1,628건 처리시간 0.025초

Active Frequency Drift Method for Islanding Detection Applied to Micro-inverter with Uncontrollable Reactive Power

  • Kwak, Raeho;Lee, June-Hee;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1918-1927
    • /
    • 2016
  • This paper proposes active frequency drift (AFD) as an anti-islanding method applied to micro-inverters with uncontrollable reactive power. When using ordinary inverter topologies, such as full bridge inverters in photovoltaic systems, the islanding phenomenon can be detected with reactive power-based methods, such as reactive power variation. However, when the inverter topology cannot control the reactive power, conventional anti-islanding methods with reactive power cannot be utilized. In this work, the topology used in this paper cannot control the reactive power. Thus, an anti-islanding method that can be used in topologies that cannot control the reactive power is proposed. The conventional anti-islanding method of the topology that cannot control reactive power is introduced and analyzed. Unlike the conventional AFD method, the proposed method extends a zero current interval every predetermined cycle. The proposed method offers certain advantages over conventional AFD methods, such as total harmonic distortion. The proposed method is validated through simulation and experiment.

무효전력 흐름 추적을 이용한 무효전력 취약지역 판단 (Reactive Power Traceable System based Vulnerable Areas Detection for Reactive Power)

  • 최윤혁;배문성;이병준
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1145-1153
    • /
    • 2015
  • The paper analyzes reactive power flow characteristic in power system by reactive power tracing. In addition, virtual buses are inserted in the algorithm to consider losses of transmission lines, and shunt capacitor treated as a reactive power generator. The results of simulation are analyzed by two points of view. The one is load’s point of view and another is generator’s point of view. Classic purpose of the reactive power tracing consists in the reactive power pricing. However, it is significantly used to select vulnerable area about line outage in this paper. To find the vulnerable area, reactive power tracing variations between pre-contingency and post-contingency are calculated at all load buses. In heavily load area, buses which has highest variation become the most vulnerable bus. This method is applied to the IEEE 39-bus system. It is compared with voltage variation result and VQ-margin to verify its effect.

순시전력 제어 이론을 이용한 유/무효전력의 독립제어에 관한 연구 (A Study on the Decoupled Control of the Active and Reactive Power using Instantaneous Power Control Theory)

  • 김응상;김지원;김영철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권6호
    • /
    • pp.678-682
    • /
    • 1999
  • In this paper, we propose the algorithm which can control active power and reactive power independently in Battery Energy Storage System. The proposed algorithm is based on the instantaneous power theory that the inner product of the voltage vector and current vector represents the active power and the cross product of those represents the reactive power, and it can control active power and reactive power independently. To verify the validity of the proposed algorithm, we make model of the real power system in th KERI and simulate this algorithm. As a result of this simulation, we verified that the proposed algorithm can control active power and reactive power independently.

  • PDF

전력계통의 전압안정도향상을 위한 감시제어시스템 개발 (A Development of Monitoring and Control System for Improved the Voltage Stability in the Power System)

  • 이현철;정기석;박지호;백영식
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.437-443
    • /
    • 2013
  • This paper was developed a monitoring and control system to use reactive power control algorithm. This algorithm could be improved voltage stability in power system. This method was controlled the voltage for stability improvement, effective usage of reactive power, and the increase of the power quality. PMS(Power Management System) has been calculate voltage sensitivity, and control reactive power compensation device. The voltage control was used to the FACTS, MSC/MSR(Mechanically Switched Capacitors/Reactors), and tap of transformer in power system. The reactive power devices in power system were control by voltage sensitivity ranking of each bus. Also, to secure momentary reactive power, it had been controlled as the rest of reactive power in the each bus. In here, reactive power has been MSC/MSR. The simulation result, First control was voltage control as fast response control of FACTS. Second control was voltage control through the necessary reactive power calculation as slow response control of MSR/MSR. Third control was secured momentary reactive reserve power. This control was method by cooperative control between FACTS and MSR/MSC. Therefore, the proposed algorithm was had been secured the suitable reactive reserve power in power system.

유.무효 전력 제어를 통한 풍력발전단지의 효율적인 운전 (A Study on Active and Reactive Power Control for Efficient Operations of Wind Farm)

  • 장성일;김지원;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1351-1354
    • /
    • 2002
  • Wind farm which are composed with wind turbine generators can be a good alternatives to solve environmental problem and solutions to cope with energy crisis for using wind energy. Until now, these wind turbine generators have been being studied on the viewpoint of only active power control for reducing the burden of main grid. In this control scheme, we might demand a reactive power compensator in order to make reparation for the reactive power produced from wind turbine generator itself. Therefore, if the reactive power as well as active power of wind turbine generator were controlled according to the demand of reactive power, the installation of a additional reactive power compensator could be reduced. This paper presents the control method of a active and reactive power for wind turbine generators by means of SVPWM(Space Vector Pulse Width Modulation) inverting method and describes a operational coordination of wind turbine generators. The proposed power control algorithm can simply produce the output power of wind turbine generator needed in wind farm, which can reduce the power of main grid more and exclude a supplementary reactive power compensator. We assumed that wind farm are composed with two kinds of wind turbine generators, AC/DC/AC and induction generator types.

  • PDF

A Study on Efficient Calculation of Effective Reactive Power Reserves Using Sensitivity Analysis

  • Bae, Moonsung;Lee, Byongjun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1689-1696
    • /
    • 2017
  • In recent academic and industrial circles of the Republic of Korea, the securement of available reactive power reserve against the line faults is at issue. Thus, simulations have been performed for the securing of effective reactive power reserve (effective Q) to prepare for the line faults and improve reactive power monitoring and control methods. That is, a research has been conducted for the fast-decoupled Newton-Raphson method. In this study, a method that distinguishes source and sink regions to carry out faster provision of information in the event of line fault has been proposed. This method can perform quantification with the formula that calculates voltage variations in the line flow. The line flow and voltage changes can be easily induced by the power flow calculation performed every second in the operation system. It is expected that the proposed method will be able to contribute to securement of power system stability by securing efficient reactive power. Also, the proposed method will be able to contribute to prepare against contingencies effectively. It is not easy to prepare quickly for the situation where voltage drops rapidly due to the exhaustion of reactive power source by observing voltage information only. This paper's simulation was performed on the large scale Korean power system in steady state.

전력산업 구조개편 환경 하에서 무효전력 보조서비스 운용을 위한 최적조류계산법 개발 (Development of Optimal Power Flow for the Ancillary Service of Reactive Power Generation under Restructuring Environment)

  • 송태용;정민화;이병준;남궁재용;문영환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.58-61
    • /
    • 2001
  • Under restructuring, not only real power pricing but also reactive power pricing is important for the system operation Especially, making a reasonable reactive power pricing is becoming more important than any other time. In this paper, the authors set a proper power factor and price the portion of the reactive power generation that exceeds the power factor. To apply this method to an optimization problem, we developed optimal power flow based on interior point method. By using this IPM for the power system, the System operator can use this strategy for reactive power generation pricing and also the Generators can got the motivation to generate reactive power.

  • PDF

델터 변조 방식을 이용한 전류형 무효전력 보상장치 (Current-Fed Reactive Power Compensator Using Delta Modulation Technique)

  • 백형래;김한성
    • 대한전기학회논문지
    • /
    • 제41권3호
    • /
    • pp.244-252
    • /
    • 1992
  • This paper describes a reactive power compensator using current-source delta modulation converter, which compensates the reactive power in the ac sides of 3-phase rectifier. In the conventional current control methods for the current-type reactive power compensators, it is usual to compare the reactive reference current signal with the triangular wave and hence to generate the ON-OFF signals for the reactive power compensator. To improve the response as well as the control capability, the delta modulated current control technique is used in this paper. As a result, the input power factor is improved close to unity and both simulation and experimental results show good compensating performances.

  • PDF

전기 무효전력비용을 고려한 조상설비계획 (Reactive Power Planning Considering Reactive Power Support Cost of Generator)

  • 이철휴;이상호;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.181-183
    • /
    • 1999
  • As one of ancillary services, voltage support and reactive power service should be compensed properly for its contribution. In this paper, a cost-based reactive power planning is presented. which minimizes the total cost of reactive power support of generators and VAR compensation facility installation. Reactive power support of generator is evaluated by the opportunity costs of reduced energy sale considering the varying SMP(system marginal price) in power market, Gradient projection method is applied to solve this reactive power planning using IEEE14 bus system.

  • PDF

무효전력시장을 이용한 무효전력서비스 요금 산정방법의 비교 및 새로운 방안 (Comparison of Methods for Calculating Reactive Power Service Charge and Proposing a New Method using Reactive Power Markets)

  • 노경수;최준호
    • 조명전기설비학회논문지
    • /
    • 제20권5호
    • /
    • pp.78-84
    • /
    • 2006
  • 전력산업이 수직독점적인 구조에서 규제완화의 경쟁체제로 전환됨에 따라 무효전력서비스의 요금산정이 전력시장 운영자에게는 새로운 이슈가 되고 있다. 본 논문은 몇몇의 선진국과 국내에서 채용되는 무효전력서비스에 대한 요금산정방법을 검토하고, 무효전력시장을 이용하는 새로운 요금산정방법을 제안한다. 무효전력시장은 무효전력 발전원이 제시하는 입찰값을 바탕으로 하루전 전력시장 후에 무효전력 최적조류계산을 거쳐 단일가격으로 결정된다. 제안하는 방법은 무효전력 설치용량에 대한 투자비뿐만 아니라 무효전력 생산량을 늘리기 위해 발전기가 줄이게 되는 유효전력에 대한 기회비용을 함께 고려하고 있다. 26모선 모델계통에서의 사례연구를 통하여 제안하는 방법의 효용성을 입증하고 있다.