• Title/Summary/Keyword: reactance

Search Result 292, Processing Time 0.022 seconds

A Characteristic of Alternative Flyback Multi-Resonant Converter (AT 플라이백 다중 공진형 컨버터의 동작특성)

  • Jeong, Jin-Beom;Kim, Hee-Jun;Kim, Chang-Sun;Woo, Seung-Hoon;Park, Woo-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1380-1382
    • /
    • 2005
  • The multi-resonant converter minimizes a parasitic oscillation by using the resonant tank circuit absorbed parasitic reactance existing in a converter circuit. So it is possible that the converter operated at a high frequency has a high efficiency because the losses are reduced. However, the resonant voltage stress across a switch is four or five times a input voltage. This high voltage stress increases the conduction loss. In this paper, we proposed the AT flyback multi-resonant converter. The proposed converter can reduce the voltage stress to two or three times by using two series input capacitors. The operational principle of the proposed converter was verified through the experimental converter.

  • PDF

Measurement of Acoustic Properties and Prediction of Acoustic Performance of Porous Woven Hoses for Engine Intake Systems (엔진 흡기계에 쓰이는 다공형 직조관의 음향특성 측정 및 성능예측)

  • Park, C.M.;Ih, J.G.;Nakayama, Y.;Kitahara, S.;Takao, H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.182-186
    • /
    • 2000
  • The porous woven hose is recently considered as an effective element of automotive intake systems. In order to predict the acoustic performance of an intake system with a porous woven hose, the information on the acoustic wall impedance is required. In this article, a measurement technique that is valid over the low frequency range and without mean flow condition is presented. The measurement is performed in a cylindrical chamber with a concentric layout of the sample and the resistance is estimated from measured reactance and transmission loss data. It is observed that the measured transmission loss for a porous woven hose with an arbitrary length agrees well with the predicted one that uses the estimated impedance for a small sample length.

  • PDF

A New Distance Relaying Algorithm for Phase-to-Ground Fault in 765kV Untransposed Transmission Lines (765kV 비연가 송전선로에서 단상지락고장 시어 거리개전 알고리즘)

  • AHN YONG JIN;KANG SANG HEE
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.452-454
    • /
    • 2004
  • An accurate digital distance relaying algorithm which is immune to reactance effect of the fault resistance and the load current for phase-to-ground fault in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for Phase-to-ground fault uses a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kV untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF

A New Distance Relaying Algorithm for Phase-to-Phase Short Fault in 765kV Untransposed Transmission Lines (765kV 비연가 송전선로에서 상간단락고장 시어 거리계전 알고리즘)

  • AHN YONG JIN;KANG SANG HEE
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.455-457
    • /
    • 2004
  • An accurate digital distance relaying algorithm which is immune to reactance effect of the fault resistance and the load current for phase-to-phase short fault in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for phase-to-phase short fault uses a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kv untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF

Numerical Calculation of Vibrational Transition Probability for the Forced Morse Oscillator by Use of the Anharmonic Boson Operators

  • Lee, Chang Sun;Kim, Yu Hang
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.7
    • /
    • pp.721-726
    • /
    • 2001
  • The vibrational transition probability expressions for the forced Morse oscillator have been derived using the commutation relations of the anharmonic Boson operators. The formulation is based on the collinear collision model with the exponential repulsive potential in the framework of semiclassical collision dynamics. The sample calculation results for H2+ He collision system, where the anharmonicity is large, are in excellent agreement with those from an exact, numerical quantum mechanical study by Clark and Dickinson, using the reactance matrix. Our results, however, are markedly different from those of Ree, Kim and Shin's in which they approximate the commutation operator I。 as unity, the harmonic oscillator limit. We have concluded that the quantum number dependence in I。 must be retained to get accurate vibrational transition probabilities for the Morse oscillator.

Performance Study of Defected Ground Structure Patch Antenna with Etched psi (ψ) Shaped Stubs

  • Nadeem, Iram;Choi, Dong-You
    • Journal of information and communication convergence engineering
    • /
    • v.16 no.4
    • /
    • pp.203-212
    • /
    • 2018
  • In this article, a novel design of patch antenna with wide band characteristics is presented. The proposed antenna is having electrical dimensions of $0.14{\lambda}{\times}0.11{\lambda}$ (at lower initial frequency) and footprints of $150mm^2$. Structural parameters optimization shows 3.1-23.5 GHz frequency range for a (reflection coefficient) $S_{11}{\leq}-10dB$ and simulated gain 6.8 dB is obtained. An equivalent circuit model is proposed to get an insight view of antenna. Advanced Systems Design (ADS) simulation results are obtain which confirm the validity of proposed model. Degenerated foster canonical form has been used to explain the reactance and capacitive behavior idea of simulated proposed antenna's input impedance later on an equivalent circuit model and smith chart is also suggested. HFSS and CST have been used to analyze antenna behavior. The proposed antenna can be further used for microwave image detection applications.

DC Superconducting fault current limiter characteristic test with a DC circuit breaker

  • So, Jooyeong;Choi, Kyeongdal;Lee, Ji-kwang;Kim, Woo-Seok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.2
    • /
    • pp.19-23
    • /
    • 2021
  • We have studied the breaking system that combines a resistive superconducting fault current limiter (SFCL) and a DC circuit breaker for DC fault current. To verify the design of the 15 kV DC SFCL, which was driven from the previous work, a 500 V DC system was built and a scale-down SFCL were manufactured. The manufactured SFCL module was designed as a bifilar coil which is a structure that minimizes inductive reactance. The manufactured SFCL module has been experiment to verify characteristics of the current-limiting performance in the DC 500 V system. Also, the manufactured FCL module was combined with the DC circuit breaker to be experimented to analyze the breaking performance. As a result of the experiment, when SFCL was combined to the DC circuit breaker, the energy dissipation received by the DC circuit breaker was reduced by up to 84% compared to when the DC circuit breaker operates alone. We are preparing methods and experiments for the optimal method for much higher performance as a future work.

The Application of Impulse Oscillometry(IOS) in the Detection of Smoking Induced Early Airway Obstruction (Impulse Oscillometry(IOS)를 이용한 흡연자에서의 조기 기도폐쇄의 연구)

  • Kim, Youn-Seup;Kweon, Suk-Hoe;Song, Mi-Young;Yoo, Sun-Mi;Park, Jae-Seuk;Jee, Young-Koo;Lee, Kye-Young;Kim, Keun-Youl
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1030-1039
    • /
    • 1997
  • Background : Impulse Oscillometry is a noninvasive and effort-independent test used to characterize the mechanical impedance of the respiratory system. The clinical potential of the IOS is rapid and demands only passive cooperation which makes it especially appealing for children, for epidemiologic surveys and for conditions in which quiet breathig instead of forced expiratory maneuvers are preferred. However, several studies have shown conflicting results that the role of IOS about detection of smoking induced small airway diseases or early airway obstruction Methods : Study was to evaluate the clinical ability of the IOS to detect about smoking induced early airway obstruction in persons with normal spirometry test. Respiratory asymptomatic study groups were formed that one is non-smoking group, another is smoking group. Results : The parameters of spirometry were not significantly differences between non-smoking group and smoking group. Among the parameters of IOS, total resistance(non-smoking group : smoking group=$2.22{\pm}1.20$ : $2.58{\pm}1.71$), peripheral resistance($1.25{\pm}0.62$ : $1.47{\pm}0.10$), bronchial compliance($0.44{\pm}0.12$ : $0.47{\pm}0.16$) were not statistically significant different (p<0.05), but central resistance and lung compliance were not statistically significant different (unit ; resistance=hPa/l/s, compliance=l/hPa). Resistance(Rrs) was not statistically significant different with changes of frequences(5, 10, 15, 20, 25, 30, 35Hz), but Reactance(Xrs) was statistically significant different with low frequences that X5(non-smoking group : smoking group=$-0.62{\pm}0.28$ : $-0.76{\pm}0.48$, p<0.001) and X10($-0.06{\pm}0.19$ : $-0.15{\pm}0.33$, p<0.013) (unit; hPall/s, $hPa{\cong}cmH_2O$). Conclusion : Impulse oocillometer(IOS) is clinically available method to detect about smoking induced early airway obstruction. And clinically potential parameters of IOS were considers that total resistance, peripheral resistance, bronchial resistance, and reactance of low frequency at 5Hz, 10Hz.

  • PDF

Wideband Colpitts Voltage Controlled Oscillator with Nanosecond Startup Time and 28 % Tuning Bandwidth for Bubble-Type Motion Detector (나노초의 발진 기동 시간과 28 %의 튜닝 대역폭을 가지는 버블형 동작감지기용 광대역 콜피츠 전압제어발진기)

  • Shin, Im-Hyu;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1104-1112
    • /
    • 2013
  • This paper presents a wideband Colpitts voltage controlled oscillator(VCO) with nanosecond startup time and a center frequency of 8.35 GHz for a new bubble-type motion detector that has a bubble-layer detection zone at the specific distance from itself. The VCO circuit consists of two parts; one is a negative resistance part with a HEMT device and Colpitts feedback structure and the other is a resonator part with a varactor diode and shorted shunt microstrip line. The shorted shunt microstrip line and series capacitor are utilized to compensate for the input reactance of the packaged HEMT that changes from capacitive values to inductive values at 8.1 GHz due to parasitic package inductance. By tuning the feedback capacitors which determine negative resistance values, this paper also investigates startup time improvement with the negative resistance variation and tuning bandwidth improvement with the reactance slope variation of the negative resistance part. The VCO measurement shows the tuning bandwidth of 2.3 GHz(28 %), the output power of 4.1~7.5 dBm and the startup time of less than 2 nsec.

A Study on the User Experience according to the Method and Detail of Recommendation Agent's Explanation Facilities (추천 에이전트의 설명 방식과 상세도에 따른 사용자 경험 차이에 관한 연구)

  • Kang, Chan-Young;Kim, Hyek;Kang, Hyun-Min
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.8
    • /
    • pp.653-665
    • /
    • 2020
  • As the use of recommended agents has become more active, the "Explain Facilities" is drawing attention as a way to solve the black-box problem that could not explain internal logic to users. This study wants to look at how the description Method and Detail affects to user experience. The Explanation method was divided into 'why the agent did a particular action' and 'why not do a particular action' and the detail condition were divided into 'high or low'. Studies have found that 'why method' have a positive effect on users' transparency, trust, satisfaction, and behavioral intention to use, and 'high detail condition' higher the user' Psychological reactance. In addition, it was found that the explanation methods and detail influenced the 'Explanation' perception through interaction and tended to affect satisfaction and intention to adopt recommendation. This study suggested that careful attention is needed to determine the method and detail of the Explanation facilities in the context of the recommended agent, based on the research findings that it affects the user experience through the interaction of the method and detail.