• Title/Summary/Keyword: re-sampling

Search Result 189, Processing Time 0.02 seconds

The Concentration Distribution and Temperature Dependence of Hexachlorocyclohexane in Rural Atmosphere (교외지역에서 대기 중 Hexachlorocyclohexane의 농도분포 및 온도 의존성)

  • 최민규;여현구;김태욱;천만영;선우영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.3
    • /
    • pp.183-192
    • /
    • 2002
  • Concentrations of $\alpha$- and ${\gamma}$-hexachlorocyclohexane (HCH) were measured in ambient air samples at a two week intervals between July 1999 and February 2000 at Ansung, Kyonggi province. Their concentration levels averaged at 78 ($\alpha$-HCH) and 18 pg/m$^3$(${\gamma}$-HCH). Although the use of HCHs was ceased in South Korea since 1979, their residues are still present in air even after nearly 20 years. Given the composition of the two main HCH pesticide formulation (technical HCH antral lindane), the $\alpha$/${\gamma}$-HCH ratio in air is a useful indicator on the regional scale. The moderately low $\alpha$/${\gamma}$-HCH ration in this study indicates previous usage of both technical HCH and lindane. The relationship of temperature with gas-phase partial pressures was also examined using the Clausius-Clapeyron equation. Slopes generated by linear regression analysis between partial pressure (In P) and 1/T were considerably steep thor HCHs. It is thus suggested that their concentrations are controlled by re-volatilization processes from surfaces in the local surroundings of the sampling site.

PROPER ORTHOGONAL DECOMPOSITION OF DISCONTINUOUS SOLUTIONS WITH THE GEGENBAUER POST-PROCESSING

  • SHIN, BYEONG-CHUN;JUNG, JAE-HUN
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.23 no.4
    • /
    • pp.301-327
    • /
    • 2019
  • The proper orthogonal decomposition (POD) method for time-dependent problems significantly reduces the computational time as it reduces the original problem to the lower dimensional space. Even a higher degree of reduction can be reached if the solution is smooth in space and time. However, if the solution is discontinuous and the discontinuity is parameterized e.g. with time, the POD approximations are not accurate in the reduced space due to the lack of ability to represent the discontinuous solution as a finite linear combination of smooth bases. In this paper, we propose to post-process the sample solutions and re-initialize the POD approximations to deal with discontinuous solutions and provide accurate approximations while the computational time is reduced. For the post-processing, we use the Gegenbauer reconstruction method. Then we regularize the Gegenbauer reconstruction for the construction of POD bases. With the constructed POD bases, we solve the given PDE in the reduced space. For the POD approximation, we re-initialize the POD solution so that the post-processed sample solution is used as the initial condition at each sampling time. As a proof-of-concept, we solve both one-dimensional linear and nonlinear hyperbolic problems. The numerical results show that the proposed method is efficient and accurate.

Assessment of water quality in an artificial urban canal: A case study of Songdo City in South Korea

  • Ahn, Jungkyu;Na, Yeji;Park, Sung Won
    • Environmental Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.582-590
    • /
    • 2019
  • Currently, the waterfront facility was constructed in New Songdo City, South Korea. It has the various water leisure areas and especially an artificial urban canal with filtered seawater by re-circulating flow system. However, due to excessive amount of nutrients from seawater combined with complicated geometry, it is highly vulnerable to deterioration of water quality. In this study, flow characteristics and pollutant transport were analyzed with comprehensive numerical models, MIKE 3 FM and ECO-lab. Based on these numerical results, notable sampling points were selected for field measurements and comparison between modeling and measured results were conducted. In addition, the integrated water quality evaluation index, Water Quality Index was applied to analyze various water quality issues. We also set up scenarios to control the two kinds of water quality factors, dissolved oxygen (DO), and total phosphorus (TP). As a result, the effect of 20% reduction of TP was less than 10% and it was almost ineffective for a year but it was reduced by up to 40% in case of scenario which DO is increased by 20%. Therefore, it was recommended to control the DO concentration, usually by applying re-aeration facility, rather than TP in artificial urban canal with seawater.

DCT and DWT Based Robust Audio Watermarking Scheme for Copyright Protection

  • Deb, Kaushik;Rahman, Md. Ashikur;Sultana, Kazi Zakia;Sarker, Md. Iqbal Hasan;Chong, Ui-Pil
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Digital watermarking techniques are attracting attention as a proper solution to protect copyright for multimedia data. This paper proposes a new audio watermarking method based on Discrete Cosine Transformation (DCT) and Discrete Wavelet Transformation (DWT) for copyright protection. In our proposed watermarking method, the original audio is transformed into DCT domain and divided into two parts. Synchronization code is applied on the signal in first part and 2 levels DWT domain is applied on the signal in second part. The absolute value of DWT coefficient is divided into arbitrary number of segments and calculates the energy of each segment and middle peak. Watermarks are then embedded into each middle peak. Watermarks are extracted by performing the inverse operation of watermark embedding process. Experimental results show that the hidden watermark data is robust to re-sampling, low-pass filtering, re-quantization, MP3 compression, cropping, echo addition, delay, and pitch shifting, amplitude change. Performance analysis of the proposed scheme shows low error probability rates.

Curtailment of Water use Through the Integration of Process Waste Waters at the Standard Thermal Power Plant (표준화력발전소의 발전폐수 통합을 이용한 용수 사용량 절감)

  • Mun, Gyeong-Seok;Jang, Heui-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.437-443
    • /
    • 2006
  • The Water usage is relationship which is close with the administrative cost from industrial facility. It is not easy to reduce a water usage. This research is the optimization of the waste water quantity which process waste water integration of the standard thermal power plant in system operate time. The turbine rotates by force of the steam and it produces an electricity. Demineralization Water is manufacture purity manufacturing equipment and it is supplied in power plant channel. We knew a possibility of reducing from pure control process. When it is reduced the Back Washing time, Rinsing time of the gravity filter and the activated carbon filter. Also, It is possible even from regeneration phase in Condensate Polishing Demineralization System. In addition, There is also the water which the drain of the sampling water for watching the condition of power plant process will be able to use. Integrates these processes it will be able to reduce an annual 30,000 ton degree. The research is want to use the fundamental data for the water curtailment of the power plant.

A Bayesian state-space production model for Korean chub mackerel (Scomber japonicus) stock

  • Jung, Yuri;Seo, Young Il;Hyun, Saang-Yoon
    • Fisheries and Aquatic Sciences
    • /
    • v.24 no.4
    • /
    • pp.139-152
    • /
    • 2021
  • The main purpose of this study is to fit catch-per-unit-effort (CPUE) data about Korea chub mackerel (Scomber japonicus) stock with a state-space production (SSP) model, and to provide stock assessment results. We chose a surplus production model for the chub mackerel data, namely annual yield and CPUE. Then we employed a state-space layer for a production model to consider two sources of variability arising from unmodelled factors (process error) and noise in the data (observation error). We implemented the model via script software ADMB-RE because it reduces the computational cost of high-dimensional integration and provides Markov Chain Monte Carlo sampling, which is required for Bayesian approaches. To stabilize the numerical optimization, we considered prior distributions for model parameters. Applying the SSP model to data collected from commercial fisheries from 1999 to 2017, we estimated model parameters and management references, as well as uncertainties for the estimates. We also applied various production models and showed parameter estimates and goodness of fit statistics to compare the model performance. This study presents two significant findings. First, we concluded that the stock has been overexploited in terms of harvest rate from 1999 to 2017. Second, we suggest a SSP model for the smallest goodness of fit statistics among several production models, especially for fitting CPUE data with fluctuations.

Bioequivalence of Two Clarithromycin Tablets (클래리스로마애신 정제의 생물학적 동등성 평가)

  • 김종국;이사원;최하곤;고종호;이미경;김인숙
    • Biomolecules & Therapeutics
    • /
    • v.6 no.2
    • /
    • pp.219-224
    • /
    • 1998
  • The bioequivalence of two clarithromvcin products was evaluated with 16 normal male volunteers (age 23-28 yr, body weight 57.5-75.517g) following single oral dose. Test product was ReYon Clarithromycin tablets (ReYon Pharm. Corp., Korea) and reference product was Klarici $d_{R}$ tablets (Abbott Korea). Both products contain 250 mg of clarithromucin. One tablet of the test or the reference product was administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). The determination of clarithromycin was accomplished using a modified agar well diffusion bioassay. As a result of the assay validation, the quantification of clarithromycin in human serum by this technique was possible down to 0.03$\mu$g/ml using 100$\mu$l of serum. The coefficient of variation (C.V.) was less than 10%. Average drug concentrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products P>0.05); the area under the curve to last sampling time (24 hr) (AU $Co_{24hr}$ (8.10$\pm$ 1.26 vs 8.22$\pm$ 1.627g . hr/ml), AUC from time zero to infinite (AU $Co_{\infty}$) (8.61 $\pm$ 1.28 vs 8.84$\pm$ 1.71 $\mu$g . hr/ml), maximum plasma concentration ( $C_{msx}$) (0.87$\pm$0.22 vs 0.88$\pm$0.19 $\mu$g/ml) and time to maximum plasma concentration ( $T_{max}$) (2.69 $\pm$0.48 vs 2.56$\pm$ 0.51 hr). The differences of mean AU $Co_{24h}$, $C_{msx}$ and $T_{msx}$ between the two products (1.44, 1.39, and 4.65%, respectively) were less than 20%. The power (1-$\beta$) and treatment difference ($\Delta$) for AU $Co_{24hr}$, and $C_{max}$ were more than 0.8 and less than 0.2, respectivly. Although the power for $T_{max}$ was under 0.8, $T_{max}$. of the two products was not significantly different each other (p>0.05). These results suggest that the bioavailability of ReYon Clarithromycin tablets is not significantly different from that of Klarici $d_{R}$ tablets. Therefore, two products are bioequivalent based on the current results. results.sults.sults.s.s.s.s.s.s.s.

  • PDF

A Study on the Optimal Cut-off Point in the Cut-off Sampling Method (절사표본에서 최적 절사점에 관한 연구)

  • Lee, Sang Eun;Cho, Min Ji;Shin, Key-Il
    • The Korean Journal of Applied Statistics
    • /
    • v.27 no.3
    • /
    • pp.501-512
    • /
    • 2014
  • Modified cut-off sampling is widely used for highly skewed data. A serious drawback of modified cut-off sampling is the difficulty of adjustment of non-response in take-all stratum. Therefore, solutions of the problems of non-response in take-all stratum have been studied in various ways such as substitute of samples, imputation or re-weight method. In this paper, a new cut-off point based on minimizing MSE being used in exponential and power functions is suggested and it can be reduced the number of take-all stratum. We also investigate another cut-off point determination method with underlying distributions such as truncated log-normal and truncated gamma distributions. Finally we suggest the optimal cut-off point which has a minimum of take-all stratum size among suggested methods. Simulation studies are performed and Labor Survey data and simulated data are used for the case study.

A sample survey design for service satisfaction evaluation of regional education offices (지역교육청 수요자 만족도조사를 위한 표본설계에 관한 연구)

  • Heo, Sun-Yeong;Chang, Duk-Joon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.4
    • /
    • pp.669-679
    • /
    • 2010
  • A sample survey design is suggested for the service satisfaction evaluation of regional education offices based on the sample size of 2009 Gyeongnam regional education offices's customer satisfaction survey. The sample design is developed to fit the goal of evaluation of individual regional offices and allocate at least the minimum sample size to each city or county in Gyeongnam to achieve the goal of the survey. The population is stratified according to the regions and the types of schools, and the sample of schools is selected with proportional to the size of classes within each stratum. Finally, each sample student is selected according to two-stage cluster sampling within each sample school. Weighting averages, weighting totals and so on can be evaluated for analysis purposes. Their variance estimates can be evaluated using re-sampling methods like BBR, Jackknife, linearization-substitution methods, which are generally used for the data from a complex sample.

Re-Examination of Opisthorchis viverrini in Nakhon Ratchasima Province, Northeastern Thailand, Indicates Continued Needs for Health Intervention

  • Kaewpitoon, Soraya J;Rujirakul, Ratana;Loyd, Ryan A;Panpimanmas, Sukij;Matrakool, Likit;Tongtawee, Taweesak;Kompor, Porntip;Norkaew, Jun;Chavengkun, Wasugree;Kujapan, Jirawoot;Polphimai, Sukanya;Phatisena, Tanida;Eaksunti, Thawatchai;Polsripradist, Poowadol;Padchasuwan, Natnapa;Kaewpitoon, Natthawut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.231-234
    • /
    • 2016
  • Opisthorchis viverrini infection is associated with cholangiocarcinoma particularly in the cases of chronic or re-infection. This presents a serious health problem in northeastern and northern Thailand. A community base approach is required for surveillance. Therefore, in a pilot project, re-examination of O. viverrini infection was conducted in the 3 districts of Nakhon Ratchasima province, Thailand, during June and October 2015. A total of 355 participants from a 194,152 population, was selected through multi-stage sampling. O. viverrini infection was determined using modified Kato Katz thick smear technique. Participants were 229 males and 126 females, and aged ${\geq}30$ years old. Prevalence of O. viverrini infection was 2.25% (8/355 participants). O. viverrini infection was slightly higher in females (3.17%), and age group between 41-50 years (4.49%). Mueang Yang district had a highest of O. viverrini infection rate (2.82%), and followed by Bua Yai (2.48%), and Chum Phuang (1.84%), respectively. O. viverrini infection rate was increased from year 2012 to 2015 particularly in Bua Yai and Mueang Yang. These re-examinion results indicate that opisthorchiasis is still problem in community of Nakhon Ratchasima province, therefore, the provincial-wide scale is need required. Furthermore health education is need intervened in the infected group, and screening of cholangiocarcinoma is urgently concerned.