• Title/Summary/Keyword: ray spacing

Search Result 128, Processing Time 0.028 seconds

Radial Variations of Ray Spacing and Intra-annual Variation of Biseriate Ray Frequency in Pinus koraiensis and Larix kaempferi Woods Grown in Korea (잣나무재와 일본잎갈나무재의 방사방향 방사조직 밀도 및 연륜 내 복열방사조직 출현 빈도수 변이)

  • Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.531-536
    • /
    • 2009
  • Radial variations of ray spacing and frequency of biseriate ray were examined in the woods of most commercially important Korean softwood species of Pinus koraiensis and Larix kaempferi. Ray spacing, or ray number per mm in cross section, averaged 4.6 and 9.0 in Pinus koraiensis and Larix kaempferi, respectively. Thus, rays of Larix kaempferi appeared to be more closely arranged than those of Pinus koraiensis. Ray spacing was the densest around pith, and then slowly decreased toward bark. In tangential section, biseriate ray frequency of Larix kaempferi was higher than that of Pinus koraiensis. Biseriate ray was designated, based on the number of cells of biseriate portion in vertical extent, as the type of B+1 (one cell high), B+2 (two cells high), and so on. The dominated type was B+1 in Pinus koraiensis but B+2 in Larix kaempferi. The biseriate ray types of B+3, B+4, and B+5 were occasionally found in earlywood. Interestingly, even B+6 and B+7 types were observed in Larix kaempferi. In conclusion, it was considered that ray spacing could be used for separating juvenile wood from adult wood. Also, characteristics of ray spacing and biseriate ray might be used for identifying these two species.

Evaluation of Usefulness of Assertive Devices to Improve the Accuracy in Skull lateral X-ray Projection (두개골 측방향 X-선 촬영에서 정확도 향상을 위한 촬영 보조 기구의 유용성 평가)

  • Bo-Seok Chang
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.153-159
    • /
    • 2024
  • In X-ray projection, Unskilled radiologists become skilled through fail exam. This causes the patient to be exposed to unnecessary radiation. In this study, pre-position unskilled radiologic technologist presented ways to improve clinical proficiency. presented a skull lateral x-ray projection practice method using visual, spatial, and assistive devices. In addition, the accuracy and usefulness of the use of assistive devices were evaluated. When X-ray images were taken based on learning, the rotational spacing, which indicates image distortion, was 7.85 ± 1.45 mm and the tiliting spacing was 4.84 ± 0.5 mm. When practicing using visual aids, the rotational spacing is 4.4 ± 0.76 mm and the inclination spacing is 3.01 ± 0.87 mm. using a spatial compensation device, the rotational spacing is 5.2 ± 0.69 mm and the tiliting spacing is 3.33 ± 0.61 mm. Skull lateral X-ray Image distortion caused by empirical photography practice decreased by 5.4%, but image distortion caused by tilting increased by 1.2%. When practicing using a visual assistive devices, the degree of rotational spacing by 40.1% and the tiliting spacing decreased by 30.7% compared to the empirical x-ray exposure practice. When using spatial assistive devices, the rotation interval was reduced by 41.7% and the tilting interval by 23.7% compared to conventional empirical x-ray exposure practice. Therefore, if an unskilled radiologist practices using visual and spatial aids,the accuracy will be improved in skull lateral x-ray projection.

Particle Spacing Analysis of Frozen Sand Specimens with Various Fine Contents by Micro X-ray Computed Tomography Scanning (Micro X-ray CT 촬영을 통한 동결 사질토 시료의 세립분 함유량에 따른 입자간 거리 분석)

  • Chae, Deokho;Lee, Jangguen;Kim, Kwang-Yeom;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.1
    • /
    • pp.31-35
    • /
    • 2017
  • The mechanical characteristics of frozen sand greatly depend on the frozen temperature and the fine contents according to the previous study by Chae et al. (2015). There are two hypotheses to explain this experimental results; one is the unfrozen water contents greatly affected by the fine contents and frozen temperature and the other is the sand particle spacing greatly affected by the pore-ice. To evaluate the latter hypothesis, the micro X-ray CT scan was performed. The micro X-ray CT scanning, one of the actively performed interdisciplinary research area, has a high resolution with micrometer unit allows to investigate internal structure of soils. In this study, X-ray CT technique was applied to investigate the effect of the frozen temperature and fine contents on the sand particle minimum and average spacing with the developed image processing techniques. Based on the spacing analysis, the frozen temperature and fine contents have little influence on the sand particle spacing in the frozen sand specimens.

Studies on the Wood Rays in Coniferous Woods - Mutural Relation on the Indicators of Wood Rays in Coniferous Woods - (침엽수재(針葉樹材)의 방사조직(放射組織)에 관(關)한 연구(硏究) - 방사조직지표치(放射組織指標値)의 상호관련성(相互關聯性)-)

  • Lee, Weon-Yong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.90-98
    • /
    • 1987
  • In the present paper I described the relations of wood ray indicators such as ray height, ray width, number of rays per $0.25mm^2$, ray spacing and fusiform ray height on the stem of Pinus koraiensis and Larix leptolepis grown at the Experiment Forest of Kangweon National University. The results may be summarized as follows. 1. The number of rays and ray spacing were generally decreased with the increase of ray height on the sample woods. 2. According to the tree species the patterns of varition of ray width with the increase of ray height were different, namely the relation between ray width and ray height showed some positive correlation on Pinus koraiensis and negative on Larix leptolepis. 3. It was recognized that the variation of fusiform ray height due to the increase of ray height indicated two patterns(the increasing, md constant regions) in sample woods. This boundary seemed to appear at six cells of ray height on Pinus koraiensis and ninc cells on Larix leptolepis. 4. The relation between fusiform ray height and number of rays had a negative correlation on Pinus koraiensis, but this tendancy was not obvious on Larix leptolepis. And ray spacing and ray width due to the increase of fusiform ray height were generally decreased. 5. On the whole the values of ray spacing and ray width became gradually larger in proportion to the increase of number of rays. 6. According to the increase of ray spacing the values of ray width also increased gradually. But this tendency was more clear on Pinus koraiensis than larix leptolepis.

  • PDF

Crystal Structure of Tension Wood by X-ray Diffraction Method (X 선(線) 회절법(回折法)에 의한 Tension Wood의 결정구조(結晶構造) 해석)

  • Lee, Won-Yong;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.73-78
    • /
    • 1993
  • Crystal structure of tension, opposite and lateral wood of Platanus orientalis L. were analysed in some aspects of crystallinity index, crystallite size, d-spacing of (200) and (004), and integrated intensity ratios with X-ray diffraction method. Crystallinity index and crystallite width in tension wood appeared somewhat larger than opposite or lateral wood. However, d-spacing and integrated intensity ratios were nearly identical irrespective of tension, opposite, and lateral wood.

  • PDF

Analysis of a flat-field soft x-ray spectrometer using a 2400-grooves/mm varied line-spacing concave grating (2400 grooves/mm 비등간격 오목에돌이발을 이용하는 평면결상형 연엑스선 분광기의 특성 해석)

  • 최일우;남창희
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.3
    • /
    • pp.189-196
    • /
    • 2002
  • The components and alignment parameters of a flat-field soft x-ray spectrometer used in the wavelength range below 50 $\AA$ are determined, and the characteristics of the spectrometer are analyzed. It consists of a toroidal mirror, a slit, a varied line-spacing concave grating, and a soft x-ray detector. The space-resolved spectral image of a source is formed on a single plane using the tordidal mirror and the 2400-grooves/mm varied line-spacing concave grating. The former is used to compensate for the astigmatism caused by the grazing incidence of soft x-ray light on the concave grating. The spectral and spatial resolutions of the spectrometer are calculated by applying the wave front aberration theory, and the diffraction efficiency is calculated by applying the scalar diffraction theory.

Intercalation of Polycarbonate/Montmorillonite Nanocomposites (폴리카보네이트와 몬모릴로나이트 나노복합체의 층간삽입)

  • 이양훈;홍성권;윤광수;최일석;이성구
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.818-825
    • /
    • 2001
  • Polycarbonate(PC)/montmorillonite (MMT) nanocomposites were prepared by solution and melt mixing methods. A d-spacing of the nanocomposites was measured by an X-ray diffractometer. Neat montmorillonite (MMT-Na) and MMTs modified by dodecyl ammonium (MMT-DA) or dimethyl hydrogenated tallow 2-ethylhexyl ammonium (MMT-25A) were used. The d-spacing value of PC/MMT-25A and PC/MMT-DA was higher than that of PC/MMT-Na. The d-spacing increased from around 12 to $37AA$ depending on the mixing method. PC was more readily introduced to the gallery of MMT as the molecular weight of PC reduced and the mixing time increased. PC/MMT-25A showed higher thermal stability by thermogravimetric analysis (TGA) than PC/MMT-DA and PC/MMT-Na.

  • PDF

X-ray diffractogram of clay treated with organic solvent (유기용매증기흡착에 의한 백토의 X-ray diffractogram의 변화)

  • 한관섭;박홍구
    • YAKHAK HOEJI
    • /
    • v.17 no.2
    • /
    • pp.111-114
    • /
    • 1973
  • Je-chun clay, Hwa-soon bentonite, and Hwa-soon montmorillonite were treated with treated with organic solvents, i.e., ethylene glycol, ethanol, n-hexane, dioxane, ethylene chlorohydrin and obtained X-ray diffractograms were compared with those of the original samples. Organic solvent was adsorbed on the basal plane surfaces of Je-chun clay, Hwa-soon bentonite, Hwa-soon montmorillonite and, as a result, the axis spacing ws increased, However, organic solvent did not affect the non-expanding lattice of Japanese acid clay and the basal plane remained unchanged.

  • PDF

Acquisition of Monochromatic X-ray Using Multilayer Mirror (다층박막 거울을 이용한 단색 엑스선 획득)

  • Chon, Kwon-Su
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.179-184
    • /
    • 2010
  • A hard X-ray microscope system for obtaining images of nano-spatial resolution has been widely studied and requires monochromatic X-ray. A multilayer mirror of 84% reflectivity was designed to acquire tungsten characteristic X-ray of 8.4 keV from the white beam generated from an X-ray tube, and the C/W multilayer mirror of $50{\times}50\;mm$ size and 5.65 nm d-spacing was fabricated by the ion-beam sputtering system. The C/W multilayer had a uniformity of 99.5%, and the structure of the multilayer mirror was verified by a TEM image. The obtainable x-ray reflectivity for the C/W multilayer mirror at 8.4 keV was estimated from measuring the X-ray reflectivity using the copper characteristic X-ray of 8.05 keV. Monochromatic X-ray of 8.4 keV was generated by combining a X-ray tube, and the reflectivity and monochromaticity were 77.1% and 0.21 keV, respectively. Monochromatic X-ray generated from the combination of an X-ray tube and an C/W multilayer mirror has enough potential to use X-ray source for hard X-ray microscope system of laboratory size. If the C/W multilayer mirror of d-spacing of a few nanometers can be fabricated, monochromatic X-ray corresponded to 17.5 keV, molybdenum characteristic X-ray, can be obtained and applied to mammography in the medical application.

Studies on the Sorption and Fixation of Cesium by Vermiculite (II)

  • Lee, Sang-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.97-111
    • /
    • 1974
  • The adsorption mechanism of Cs-137 in low level radioactive solution by vermiculite treated with Na ion is studied in order to investigate its effective utilization for the radioactive effluent treatment. The beneficial role of Na-vermiculite is that Na ion can induce the wider c-axis spacing in which Cs ion can be sorbed in vermiculite. Cation exchange capacity and distribution coefficient of cesium seems to be influenced by the variation of c-axis spacing of vermiculite. Comparative identification and detection with the characteristic analyses of X-ray diffraction and electron diffraction patterns, diffrential thermal analysis and electron microscopy of Na-, K- and Cs-vermiculite are studied for the phemomena of Cs adsorption by vermiculite. This importance of the utilization in terms of adsorption and fixation of cesium involving vermiculite is discussed. It is found that the Na-vermiculite is valuable outside charging material for high level radioactive liquid waste storage tank of underground to protect the pollution of the underground water.

  • PDF