• 제목/요약/키워드: ray optimization

검색결과 191건 처리시간 0.032초

소아 구내촬영 시 방사선량 평가 및 최적화 방안에 대한 연구 (A Study of Radiation Dose Evaluation and Optimization Methods for Intra Oral Dental X-ray in Pediatric Patient)

  • 이현용;조용인
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.195-203
    • /
    • 2021
  • Although intra oral dental x-ray is a lower dose than other radiological examinations, pediatric patients are known to have a higher risk of radiation damage than adults. For this reason, pediatric dental x-ray requires management of dose evaluation and imaging conditions during the examination. In this study, the dose calculation program ALARA-Dental(child/adult) was used to evaluate the organ dose and effective dose exposed to each examination site during intra oral imaging of children during dental radiographic examination, and dose analysis according to the imaging conditions was performed. As a result, the highest organ dose distribution was shown at 0.044 ~ 0.097 mGy in all are as of the mucous membrane of oral cavity except for the maxillary incisors and canines. Also, in the case of the thyroid gland, the maxillary canine and maxillary premolar examination showed 0.027 and 0.020 mGy, respectively, and the dose distribution was 15.4% to 70.0% higher than that of the mandibular examination. As for the effective dose calculated during intra oral imaging, the maxillary anterior and canine examinations showed the highest effective doses of 0.005 and 0.004 mSv, respectively, and the maxillary area examination showed a higher dose distribution on average than the mandible.

PC 기반의 3차원 의료영상 재구성 시스템의 고속화 설계 (Speed Optimization Design of 3D Medical Image Reconstruction System Based on PC)

  • 배수현;김선호;유선국
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권2호
    • /
    • pp.189-198
    • /
    • 1998
  • 3차원 의료영상 재구성 기법은 2차원 의료영상으로부터 인체의 복잡한 3차원 구조를 이해하는데 많은 도움을 준다. 본 논문에서 구현한 3차원 의료영상 재구성 시스템은 저가의 PC 기반에서 시스템의 환경에 상관없이 사용될 수 있도록 Visual C++4.2를 이용하여 작성하였으며 향후 확장성을 고려하여 각 기능을 모듈화 시켰다. 모듈 설계된 3차원 의료영상 재구성 시스템은 데이터 준비, 그래디언트 근시화, 분할, 음영처리, 좌표시스템 변환, 그리고 광선투사와 합성 모듈로 구성되었다. 본 논문에서는 3차원 의료영상 재구성 방법의 속도문제를 개선하여 저가의 PC 환경에서 구현하였다. PC 환경에서 3차원 의료영상 재구성 시스템을 구현하기 위하여 광선투사를 재구성되는 영상에 영향을 주지 않는 범위에서 조기 중단시키는 알고리듬과 영상 재구성에 참여하는 체적소를 줄이는 방법, 그리고 영상을 재구성하기 위한 광선투사 과정에서 투시되는 광선의 수를 줄이는 방법 등ㄹ을 적용하여 PC환경에서 3차원 의료영상 재구성 시스템의 고속화를 이루었으며 실험에 의해서 PC환경에서도 의료영상 재구성 알고리듬이 효과적으로 사용되었다.

  • PDF

이중 적층 구조 표적을 갖는 투과형 엑스선관의 몬테카를로 전산모사 (Monte Carlo Simulation of Transmission-Type X-ray Tube with Dual-Structured Target)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제17권1호
    • /
    • pp.107-114
    • /
    • 2023
  • 엑스선형광분석은 비파괴적으로 시료에 포함된 원소와 농도를 분석할 수 있는 기법으로 과학 및 산업 분야에 광범위하게 사용되고 있다. 다양한 물질을 포함한 혼합물 또는 화합물 분석의 정밀도 향상을 위해 10 keV 근방의 저에너지와 20 keV 근방의 에너지 영역에 높은 강도 분포를 갖는 엑스선관이 요구된다. 두 에너지 영역에서 높은 강도 분포를 갖는 스펙트럼을 얻기 위하여 9.65 keV의 특성엑스선을 가지는 텅스텐과 17.48 keV의 몰리브덴 두 물질을 적층한 구조의 표적을 가지는 투과형 엑스선관을 몬테카를로 전산모사를 통해 스펙트럼을 분석하였다. W-Mo 구조의 표적을 통해 10 keV와 20 keV 근방의 강한 강도를 갖는 특성엑스선을 얻었다. 또한 4 ㎛ 두께의 Mo-W multilayers 구조의 표적을 통해 최적의 강도 분포를 갖는 스펙트럼을 얻을 수 있음을 확인하였다. 다양한 표적 물질을 선택 조합하고 두께 최적화를 통해 원하는 에너지 대역에서 높은 강도 분포를 갖는 스펙트럼을 얻는 것이 가능하다.

PIB법을 이용한 대면적 $HgI_2$ 검출기의 I-V 특성평가 (I-V Measurements of large area $HgI_2$ X-ray detector produced by PIB method)

  • 김경진;박지군;강상식;차병열;조성호;신정욱;문치웅;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.254-255
    • /
    • 2005
  • In this paper, we investigated electrical characteristics of the X-ray detector of mercuric iodide (HgI2) film fabricated by PIB(Particle-in-Binder) Method on ITO substrates 17cm$\times$20cm in size with thicknesses ranging from approximately 200${\mu}m$ to 240${\mu}m$. In the present study, using I-V measurements, their electrical properties such as leakage current, X-ray sensitivity, and signal-to-noise ratio (SNR),were investigated. The results of our study can be useful in the future design and optimization of direct active-matrix flat-panel detectors (AMFPD) for various digital X-ray imaging modalities.

  • PDF

열상장비용 줌무초점망원경 설계 (Optical Design of Afocal Zoom Telescope System for Thermal Imagery)

  • 홍경희;김창우
    • 한국광학회지
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 1995
  • 열상장비용 줌망원경계통을 설계하였다. 대물경계는 4배로부터 14배까지 배율이 변화할 수 있는 줌광학계통으로 설계하였고 접안경은 초점거리 25mm의 삼중렌즈계통으로 설계하였다. 처음에는 대물경계와 접안경을 구분하여 설계하고 후에 이를 통합하여 무초점계로 설계하였다. 1st order optics에 의해 계통을 확립하고 3rd order optics에 의해 초기설계를 얻었으며 후에 유한광선추적으로 모든 고차수차를 포함하는 ray aberration 또는 angular aberration이 최소가 되도록 최적화 하였다. 최종설계를 회절광학적 MTF를 계산하여 성능을 평가하였다.

  • PDF

마이크로 광학계의 설계에서 비구면 렌즈의 조합 효과 (Effect of Combination with Aspherical Lens in the Micro Optical System Design)

  • 김명중;김한섭;박규열;전종업;김의중
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1422-1425
    • /
    • 2003
  • In the design of optical system, important variables of optical system (including indices, shapes, spaces, stops. etc.) must manipulate in order to balance out offensive aberration. In this paper, it carried out a basic study on the design of micro optical system usable for the acquaintance of visual information in the particular conditions such as capsule type endoscopes. In this study, specification for design of optical system selected voluntarily and the basic design of optical system carried out by using the ray tracing method on the assumption that ideal lenses without aberrations. In the designed optical system, the optimization including aberration correction and the performance evaluation of optical system carried out by using the CODE-V. The final designed optical system consists of seven sheets of lenses. Also the results of performance evaluation. the micro optical system combined with aspherical lenses was confirmed to have improved optical performance as compared with the micro optical system consisted of spherical lenses.

  • PDF

Calibration을 통한 스테레오 X-ray 검색장치의 기하구조 최적화 연구 (The Study of the Geometric Structure Optimization for the Stereo X-ray Inspection System Using the Calibration)

  • 황영관;이남호;이승민
    • 한국산학기술학회논문지
    • /
    • 제11권9호
    • /
    • pp.3422-3427
    • /
    • 2010
  • 본 논문에서는 빠르게 움직이는 화물 대상체의 효율적인 검색을 위해 스테레오 X-선 영상을 이용하여 장치 켈리브레이션을 통한 최적화된 구조에 대하여 연구하였다. 스테레오 X-선 스캔 영상은 X-선 발생장치, 듀얼 라인 어래이 검출기, 컨베이어 시스템 등으로 구성된 특별하게 제작된 스테레오 X-선 검색 장치로부터 획득하였다. 스테레오 X-선 영상을 이용하여 영상과 실제 대상체의 3차원 형상 구성사이의 관계를 찾기 위해 센서에 대한 캘리브레이션을 수행하였다. 스테레오 영상을 얻기 위해 구성된 두 개의 검출기 사이의 거리를 다양하게 변화 시키며 획득한 영상을 이용하여 영상에서의 GCP(Ground Control Point)에 대하여 계산 하였다. 계산된 GCP 값과 실제 대상체의 GCP의 좌표값을 비교하여 오차가 작은 효율적인 장치의 구조에 대하여 결과를 얻었다. 실험의 결과는 화물검색을 위한 영상의 효율적인 가시화 및 스테레오 매칭의 정확도를 향상시키기 위해 활용될 것이다.

감마선 영상화 장치용 경량 고효율 차폐체 최적설계에 관한 연구 (A study on the optimization of light weight high efficiency shield for gamma-ray imaging detector)

  • 박강택;이남호;황영관
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.773-774
    • /
    • 2016
  • 본 논문에서는 감마선원 영상화를 위한 감마선 탐지장치에 적용할 차폐체의 경량, 소형화 연구를 수행하였다. 선행 연구를 통해 상용 감마선 영상화 장치의 차폐체와 유사한 차폐효율 및 성능을 나타내는 납 기반의 차폐체를 구현하였으며, 본 논문에서는 납 기반의 차폐체보다 경량화, 소형화를 위해 텅스텐기반의 차폐체를 설계하였다. 차폐체 설계를 위해서 MCNP 전산모사를 수행하였으며, 그 결과 17%의 경량화 및 51%의 체적을 줄이는 결과를 얻었다.

  • PDF

Convergence Modeling and Reproduction of a Bigyeokjincheolloe (Bomb Shell) Based on Three-dimensional Scanning and 𝛾-ray Radiography

  • Kim, Da Sol;Jo, Young Hoon;Huh, Il Kwon;Byun, Sung Moon
    • 보존과학회지
    • /
    • 제38권1호
    • /
    • pp.55-63
    • /
    • 2022
  • The Bigyeokjincheolloe (bomb shell), a scientific cultural heritage, has outstanding historical value for sustaining a gunpowder weapon of Joseon. In this study, the bomb shell was modeled through three-dimensional (3D) scanning centered on the external shape and 𝛾-ray radiography-based on the internal shape. In particular, to improve the contrast in the radiographic image, optimization and image processing were performed. After these processes, the thickness of the inner wall (2.5 cm on average) and the positions of the three mold chaplets were clearly revealed. For exhibition purposes, the 3D model of the bomb shell was output to a 3D printer and the output was rendered realistic by coloring. In addition, the internal functional elements, such as Mokgok, fuse, mud, gunpowder, and caltrops, were reproduced through handwork. The results will contribute to the study of digital heritages in two ways. First, the internal and external shapes of the bomb shell were modeled by fusing two different technologies, namely, 3D scanning and 𝛾-ray radiography. Second, the internal shape of the bomb shell was constructed from the original form data and the reproduction was utilized for museum exhibitions. The developed modeling approach will greatly expand the scope of museum exhibitions, from those centered on historical content to those centered on scientific content.