• Title/Summary/Keyword: ray casting

Search Result 200, Processing Time 0.026 seconds

Methylene blue-PVA Dosimeter (Methylene blue-PVA 선량계(線量計))

  • Chung, W.H.;Kim, H.S.;Kim, H.J.;Jung, H.T.
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.1
    • /
    • pp.64-66
    • /
    • 1985
  • A methylene blue-PVA system has been tested as a krad range dosimeter. Mb dye films were fabricated by casting PVA in solution with the methylene blue. In the air the system was irradiated by X-ray and the decolorisation of the dye film was found to remain unchanged for sufficiently long time. The radiation response on optical density at 670 nm in the Mb-PVA system shows a quite good linearity and reproducibility in the krad range.

  • PDF

Development of Surface-mount-type Crown-shaped Lens for Reducing Glare Effect of Light-emitting Diode Light Source (LED 광원의 눈부심 현상을 감소시키기 위한 표면 실장형 CR 렌즈 개발)

  • Park, Yong Min;Bang, Hyun Chul;Seo, Young Ho;Kim, Byeong Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.1
    • /
    • pp.64-68
    • /
    • 2014
  • This paper introduces the use of a crown-shaped (CR) lens to effectively diffuse the light from a light-emitting diode (LED) without any loss in the light intensity, in contrast to polymer-bulb-type diffusers. The diffusion lens was designed based on the Snell's law, which describes the physical path of a ray passing through the boundary between different media. CR lenses were fabricated by polydimethylsiloxane (PDMS) casting and UV-embossing processes, which used a pre-designed metal mold and UV-curable resin, respectively. Through experiments and optical evaluations, it was verified that the newly proposed CR lens not only decreased the vertical light strength and glare effect from an LED light source but also improved the diffusion characteristics while maintaining the quality of the LED's light intensity.

Effect of $B_{2}O_{3}$ addition on mechanical strength and microstructure of a porous $LiAlO_{2}$ electrolyte support for molten carbonate fuel cells (용융 탄산염 연료전지용 gamma $LiAlO_{2}$ 전해질 지지체의 미세구조 및 기계적 강도 변화에 대한 $B_{2}O_{3}$ 첨가의 영향)

  • Ham, Hyung-Chul;Yoon, Sung-Pil;Hong, Seong-Ah
    • New & Renewable Energy
    • /
    • v.3 no.1 s.9
    • /
    • pp.54-59
    • /
    • 2007
  • A sintering aid, $B_{2}O_{3}$ have been included into a $LiAlO_{2}$ electrolyte support by a tape casting method in order to reinforce mechanical strength of the support for molten carbonate fuel cells [MCFCs). Starting idea originates from the low melting point of $B_{2}O_{3}$ ($450^{\circ}C$), which can provide the low temperature consolidation of ceramic materials. The mechanical properties and the microstructure changes of the $B_{2}O_{3}$-included electrolyte support were examined by scanning electron microscope, mercury porosimetry, X-ray powder diffraction [XRD], high temperature differential scanning calorimeter and three-point bending strength measurement. The mechanical strength was clearly improved by addition of $B_{2}O_{3}$. The increase of mechanical strength results from the neck growth of a new $LiAlO_{2}$ phase between $LiAlO_{2}$ particles by the liquid phase sintering. Average pore size and porosity of the electrolyte support reinforced by addition of the sintering aid, $B_{2}O_{3}$, was $0.24{\mu}m$ and 59%, respectively which were suitable microstructure of a matrix for an application of MCFCs.

  • PDF

Synthesis and Characterization of Reduced Graphene Oxide/Gelatin Composite Films (환원된 산화그래핀/젤라틴 복합필름의 합성과 분석)

  • Chen, Guangxin;Qiao, Congde;Xu, Jing;Yao, Jinshui
    • Polymer(Korea)
    • /
    • v.38 no.4
    • /
    • pp.484-490
    • /
    • 2014
  • Reduced graphene oxide (RGO) was fabricated using gelatin as a reductant, and it could be stably dispersed in gelatin solution without aggregation. A series of RGO/gelatin composite films with various RGO contents were prepared by a solution-casting method. The structure and thermal properties of the RGO/gelatin composite films were characterized by UV-vis spectroscopy, Fourier transform infrared (FTIR) spectroscopy, X-ray diffraction (XRD), atomic force microscopy (AFM), scanning electron microscopy (SEM), differential scanning calorimeter (DSC) and thermal gravimetric analysis (TGA). The addition of RGO enhances the degree of crosslinking of gelatin films and decreases the swelling ability of the gelatin films in water, indicating that RGO/gelatin composite films have a better wet stability than gelatin films. The glass transition temperature ($T_g$) of gelatin films is also increased with the incorporation of RGO. The presence of RGO slightly increases the degradation temperature of gelatin films due to the very low content of RGO in the composite films. Since gelatin is a natural and nontoxic biomacromolecule, the RGO/gelatin composite films are expected to have potential applications in the biomedical field.

Fabrication of an Electrostrictive Fluorinated Terpolymer Sheet Applicable to Artificial Muscle Systems (인공 근육에 응용 가능한 전기변형 불화 고분자 박막의 제작)

  • Kim, Sung-Jin
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.4
    • /
    • pp.276-279
    • /
    • 2011
  • Polymer electrostrictor materials can exhibit high electroactive strain and hold increasing promise for a variety of actuator applications. The size of available actuators has been limited, however, by the solution-based casting and annealing process generally required to prepare electrostrictor actuator materials. We report on a high throughput melt and stretch extrusion process capable of creating large sheets of an electrostructive terpolymer, poly (vinylidene fluoride-trifluoroethylene-1, 1-chlorofluoroethlene) while producing a suitable crystallinity and crystal phase for high strain electrostrictor performance such as artificial muscle systems.

Effect of Fe3O4 loading on the conductivities of carbon nanotube/chitosan composite films

  • Marroquin, Jason;Kim, H.J.;Jung, Dong-Ho;Rhee, Kyong-Yop
    • Carbon letters
    • /
    • v.13 no.2
    • /
    • pp.126-129
    • /
    • 2012
  • Nanocomposite films were made by a simple solution casting method in which multi-walled carbon nanotubes (MWCNT) and magnetite nanoparticles ($Fe_3O_4$) were used as dopant materials to enhance the electrical conductivity of chitosan nanocomposite films. The films contained fixed CNT concentrations (5, 8, and 10 wt%) and varying $Fe_3O_4$ content. It was determined that a 1:1 ratio of CNT to $Fe_3O_4$ provided optimal conductivity according to dopant material loading. X-ray diffraction patterns for the nanocomposite films, were determined to investigate their chemical and phase composition, revealed that nanoparticle agglomeration occurred at high $Fe_3O_4$ loadings, which hindered the synergistic effect of the doping materials on the conductivity of the films.

Microstructure and Hardness of Ti-X%Cu(X=2,5,10) Alloys for Dental Castings (치과주조용 Ti-X%Cu(X=2,5,10)합금의 미세조직 및 경도)

  • Jung, Jong-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.31 no.3
    • /
    • pp.9-14
    • /
    • 2009
  • This study evaluated the mechanical properties of Ti-Cu alloys with the hope of developing an alloy for dental casting with better mechanical properties than unalloyed titanium. Ti-Cu alloys with four concentrations of Cu(2,5,10wt%) were made in an argon-arc melting furnace. The microstructure and micro-Vickers hardness were determined. X-ray diffraction pattern test was performed on the polished specimens. The microstructure of 2%Cu and 5%Cu alloys are shown acicular ${\alpha}Ti$ phase formed on the surfaces of previously formed $\beta$grains. The 10%Cu alloys has essentially a eutectoid structure; this structure includes lamella of ${\alpha}Ti$ and $Ti_2Cu$ phase that transformed from ${\alpha}Ti$ at the eutectoid temperature. The micro-Vickers hardness of CP Ti specimens was significantly(p<0.05) lower than that of any of the other alloys. Among the Ti-Cu alloys, the 10%Cu alloys exhibited a significantly(p<0.05) higher hardness value. but lower than that of Ti-6%Al-4%V alloy. From these results, it was concluded that new alloys for dental castings should be designed as Ti-Cu based alloys if other properties necessary for dental castings were obtained.

  • PDF

A Tele-conferncing System for Medical Dignosis based on 3D-medicl Images (3차원 의료영상 기반의 원격 진단회의 시스템)

  • Seo, Yeong-Geon;Kim, Eung-Hwan;Jeong, Mun-Ryeol;Park, Yeong-Taek;O, Hae-Seok
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.5
    • /
    • pp.1046-1058
    • /
    • 1996
  • In this paper, we describe an abvanced medical diagnostic system using multimedia technologies in netwok environments. In the system, docotors in remote sites perorm medicl diagnosis by exchanging information about patients and 3-D medicl images of malfunctioning body parts, which are reconstructed from 2-D images such as MRI, CT, CR, Angio. The diagnosic conferencing system controls the conferencing process by exchanging audio, information about patients, 3-D medical images and control data. 3-D medicl images are reconstructed by a ray casting method that uses an nalytical integration. Medical databae conists of absic information about patients, Information about medicl images, users, results of dianosis.

  • PDF

Effect of Ceramic-Electrode Interface on the Electrical Properties of Multilayer Ceramic Actuators (적층형 세라믹 액츄에이터의 세라믹-전극간 계면이 전기적 특성에 미치는 영향에 대한 연구)

  • 하문수;정순종;송재성;이재신
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.10
    • /
    • pp.896-901
    • /
    • 2002
  • The polarization and strain behavior of multilayer ceramic actuators fabricated by tape casting using a PNN-PZT ceramics were investigated in association with electrode size and internal layer number. Spontaneous polarization and strain decreased with increasing electrode size. In addition, the increase of internal layer number brought reduced spontaneous polarization and increased the field-induced strain. Because the actuators structure is designed to stack ceramic layer and electrode layer alternatively, the ceramic-electrode interfaces may act as a resistance to motion of domain wall. To analyze the effect of ceramic-electrode interface, the diffraction intensity ratio of (002) to (200) planes was calculated from X-ray diffraction patterns of samples subjected to a voltage of 200 V. The diffraction intensity ratio of (002) to (200) planes was decreased with increasing electrode size and internal layer number. The diffraction intensity ratio and straining behavior analyses indicate that the Polarization and strain were affected by the amount of 90°domain decreasing with increasing electrode size and internal layer number. Consequently, the change of polarization and displacement with respect to electrode size and layer number is likely to be caused by readiness of the domain wall movement around the interface.

Improvement Depth Perception of Volume Rendering using Virtual Reality (가상현실을 통한 볼륨렌더링 깊이 인식 향상)

  • Choi, JunYoung;Jeong, HaeJin;Jeong, Won-Ki
    • Journal of the Korea Computer Graphics Society
    • /
    • v.24 no.2
    • /
    • pp.29-40
    • /
    • 2018
  • Direct volume rendering (DVR) is a commonly used method to visualize inner structures in 3D volumetric datasets. However, conventional volume rendering on a 2D display lacks depth perception due to dimensionality reduction caused by ray casting. In this work, we investigate how emerging Virtual Reality (VR) can improve the usability of direct volume rendering. We developed real-time high-resolution DVR system in virtual reality, and measures the usefulness of volume rendering with improved depth perception via a user study conducted by 38 participants. The result indicates that virtual reality significantly improves the usability of DVR by allowing better depth perception.