• 제목/요약/키워드: ratio control

Search Result 9,926, Processing Time 0.042 seconds

Electronic Ratio Control of Metal Belt CVT (금속벨트 CVT 변속비 전자제어화)

  • 김달철;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.100-109
    • /
    • 2000
  • In this paper a stepping motor drive electronic ratio control system for a metal belt CVT is suggested. The electronic ratio control system developed in this study is designed to control flow rate which is required to obtain the shift speed and to control the primary actuator pressure to maintain the desired ratio. Considering these control characterstics a fuzzy logic is used for the CVT ratio control. Using the fuzzy logic dynamic models of the ratio control system is investigated and compared with the experimental results. The experimental and simulation results show that the electronic ratio control system developed in this study can be used in CVT system for the active control of the speed ratio.

  • PDF

A Study of the Relationship between Keratinization of Oral Mucosa and Intraoral Soft Tissue Disease (구강내 연조직 질환과 구강점막 각화도와의 관계)

  • Song, Ju-Jong;Kim, Byung-Goo;Choi, Hong-Ran
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.1
    • /
    • pp.1-10
    • /
    • 2001
  • To investigate the relationship between several intraoral soft tissue lesions(hairy tongue, lichen planus, recurrent aphthous stomatitis, oral candidiasis, glossitis and oral herpetic lesion) and oral mucosal keratinization, exfoliative cytological smear on intraoral mucosal surfaces were performed on each number of patients and 25 controls keratinization cell (yellow-stained cell) ratio was then measured. In hairy tongue, there was no significant difference between patient group and control group in all kind of cells. Only blue cell ratio of women was more than of men in patient group. In lichen planus, there was no difference between patient and control group in yellow cell ratio. Red cell ratio in the control group was more than in the patient group. Blue cell ratio in the patient group was more than that in control group. But there was no sex predilection between both groups in the ratio of all kind of cells. In recurrent aphthous stomatitis, Yellow cell ratio in the control group was more than that in the patient group. Red cell ratio in the control group was more than that in control group. Blue cell ratio in the patient group was more than that in control group. But there was no sex predilection between both groups in the ratio of all kind of cells. In oral candidiasis, Yellow cell ratio in the control group was more than that in the patient group. Red cell ratio in the control group was more than that in control group. Blue cell ratio in the patient group was more than that in control group. There was no sex predilection between both groups in yellow cell ratio. Red cell ratio of women was more than of men in patient group. Blue cell ratio of men was more than of women in patient group. In herpetic lesions, there was no difference between patient and control group in yellow cell ratio. Red cell ratio in the control group was more than in the patient group. Blue cell ratio in the patient group was more than that in control group. Yellow cell ratio of women was more than of men in control group. Red cell ratio of men was more than of women in control group. Blue cell ratio of men was more than of women in patient group. In glossitis, Yellow cell ratio in the control group was more than in the patient group. There was no difference between patient and control group in red cell ratio. Blue cell ratio in the patient group was more than that in control group. Yellow cell ratio of women was more than of men in control group. Red cell ratio and blue cell ratio of men were more than of women in control group. According to above results, the ratio of keratinized cell in atrophic, ulcerated, or pseudomembranous lesions was lowered than in control, but the ratio of keratinized cell in keratotic, vesicular or lesions on keratinized surface lesions had no difference to control group. Thus, keratotic, vesicular or lesions on keratinized surface lesions have not closely relation to mucosal keratinization. And, there was a little sex predilection between men and wemen in mucosal keratinization.

  • PDF

Analysis of Ratio Changing Characteristics of a Metal V-Belt CVT Adopting Primary Pressure Regulation (압력제어 방식 금속 벨트 CVT 변속특성 해석)

  • 최득환;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.5
    • /
    • pp.179-187
    • /
    • 2001
  • In this paper, a primary pressure regulating type ratio control system is developed for a metal belt CVT, and the CVT ratio changing characteristics are investigated by simulation and experiment. The hydraulic part of the ratio control system has a simple structure with one 3-way spool valve as a main ratio control valve and one bleed type variable force solenoid as a pilot valve. The mathematical modelling of the CVT hydraulic system is derived by considering the CVT shift dynamics. Simulation results of CVT speed ratio and the primary pressure agree with the experimental results demonstrating the validity of the dynamic models. It is found from the simulation and experimental results that the response time of speed ratio and primary pressure can be shortened by increasing the ratio control valve port area, and the size of feedback orifice of ratio control valve gives a damping effect on the primary pressure oscillation.

  • PDF

Effect of C/N Ratio on Composting Treatment of TNT-Contaminated Soil

  • In, Byung-Hoon;Park, Joon-Seok;NamKoong, Wan
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.6
    • /
    • pp.578-584
    • /
    • 2006
  • This research was conducted to estimate the effect of C/N ratio control on composting of TNT (2,4,6 trinitrotoluene)-contaminated soil. Glucose or acetone was selected to control C/N ratio of the contaminated soil. The C/N ratios of the controlled experiment and no controlled one were 26.0 and 6.6, respectively. During 45days, the degradation efficiency (96.0 or 91.8%) of acetone or glucose C/N ratio controlled soil was higher than that (78.4%) of no C/N ratio controlled case. The first order degradation rate constant of glucose or acetone C/N ratio control was 0.0641 or 0.0820/day. This constant was over twice 0.0356/day of no C/N ratio control. The C/N ratio control with glucose or acetone also showed a rather high $CO_2$ evolution than that without C/N ratio control. It was proven that C/N ratio control for composting of TNT-contaminated soil improved the treatment efficiency.

Ratio Control of CVT by Considering the CVT System Efficiency (CVT 시스템 효율을 고려한 변속 제어)

  • Ryu, Wan-Sik;Kim, Hyun-Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.157-163
    • /
    • 2006
  • A modified ratio control algorithm is proposed for the improvement of the fuel economy for a metal belt CVT. In the modified ratio control algorithm, the CVT ratio is controlled to operate the engine on the optimal operation region which provides the best efficiency from the view point of the overall efficiency of the engine-CVT system. In order to construct the modified ratio map, the CVT system loss model is used by assuming that the all the loss is attributed to the torque loss. It is found from the simulation results that the fuel economy by the modified ratio control algorithm is improved by 5.5 percents compared with the existing ratio control.

Low Level Control of Metal Belt CVT Considering Shift Dynamics and Ratio Valve On-Off Characteristics

  • Kim, Tal-Chol;Kim, Hyun-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.645-654
    • /
    • 2000
  • In this paper, low level control algorithms of a metal belt CVT are suggested. A feedforward PID control algorithm is adopted for line pressure based on a steady state relationship between the input duty and the line pressure. Experimental results show that feedforward PID control of the line pressure guarantees a fast response while reducing the pressure undershoot which may result in belt slip. For ratio control, a fuzzy logic is suggested by considering the CVT shift dynamics and on-off characteristics of the ratio control valve. It is found from experimental results that a desired speed ratio can be achieved at steady state in spite of the fluctuating primary pressure. It is expected that the low level control algorithms for the line pressure and speed ratio suggested in this study can be implemented in a prototype CVT.

  • PDF

Study on Engine-CVT Consolidated Control(I) -Development of Consolidated Control Algorithm (엔진-CVT 통합제어에 관한 연구(I) -통합제어 알고리즘 개발)

  • 김달철;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.86-96
    • /
    • 1997
  • In this paper, engine-CVT consolidated control algorithm was developed. Engine -CVT control strategy suggested uses throttle control based on power difference and CVT ratio control based in CVT ratio map. Simulation results showed that the larger the rate of CVT ratio, the better the engine performance in the optimal operation line. Also, it was found that the engine performance where the magnitude of the acceleration changes abruptly depends on the magnitude of the rate of CVT ratio. Comparing the results of CVT control only without engine control, the engine-CVT control algorithm suggested in this work showed better performance demonstrating that the consolidated control algorithm should be required for the engine optimal operation.

  • PDF

Modulated Fuel Feedback Control of a Fuel Injection SI Engine (연료량 변조법에 의한 연료분사식 가솔린엔진의 공연비 제어)

  • 박경석;박진일;고상근;노승탁;이종화
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.102-111
    • /
    • 1996
  • For the air-fuel ratio control in a fuel injection SI engine, the Jump-Ramp control algorithm has been widely adopted by using the on/off type oxygen sensor. But the Jump-Ramp control method has limitation on treating the frequency and amplitude of the air-fuel ratio oscillation. This study suggests another feedback control logic named modulated fuel feedback control, which has a concept of pre-tuned air-fuel ratio oscillation. In the modulation method, the oxygen sensor output is not treated as on/off signal but as analog signal for feedback. By using the modulation method, the frequency and the amplitude of air-fuel ratio oscillation can be adjustable to some extent for improving the conversion efficiency of the Three-Way Catalyst. The result shows that the performance of the modulation method is better than that Jump-Ramp control method in reducing the amplitude of the air-fuel ratio oscillation as well as in increasing the frequency of the air-fuel ratio oscillation.

  • PDF

A New Direct Torque Control Scheme of an Induction Motor Using Duty Ratio Modulation

  • Park, Jeong-Woo;Lee, Dong-Myung
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1223-1231
    • /
    • 2018
  • The direct torque control (DTC) scheme features a simple structure thanks to stator flux-oriented control. It has the advantage of robustness against motor parameters variation since only the stator resistance is involved in the control scheme. On the other hand, the disadvantage of DTC is large torque ripple. To reduce the torque ripple, many studies on DTC-space vector modulation (DTC-SVM) schemes, which modulate the duty ratio with a fixed switching cycle, have been proposed. However, there is the difficulty in obtaining the duty ratio for DTC-SVM. Hence, this paper proposes a new duty ratio selection and stator flux calculation methods for reducing torque ripple. Simulations and experiments were carried out to determine the validity of the proposed method. The proposed scheme has simplified the duty ratio command and achieved the same control performance as the conventional duty ratio modulation method without using the information of motor parameters.

HARDWARE IN THE LOOP SIMULATION OF HYBRID VEHICLE FOR OPTIMAL ENGINE OPERATION BY CVT RATIO CONTROL

  • Yeo, H.;Song, C.H.;Kim, C.S.;Kim, H.S.
    • International Journal of Automotive Technology
    • /
    • v.5 no.3
    • /
    • pp.201-208
    • /
    • 2004
  • Response characteristics of the CVT system for a parallel hybrid electric vehicle (HEV) are investigated. From the experiment, CVT ratio control algorithm for the optimal engine operation is obtained. To investigate the effect of the CVT system dynamic characteristics on the HEV performance, a hardware in the loop simulation (HILS) is performed. In the HILS, hardwares of the CVT belt-pulley and hydraulic control valves are used. It is found that the engine performance by the open loop CVT ratio control shows some deviation from the OOL in spite of the RCVs open loop control ability. To improve the engine performance, a closed loop control of the CVT ratio is proposed with variable control gains depending on the shift direction and the CVT speed ratio range by considering the nonlinear characteristics of the RCV and CVT belt-pulley dynamics. The HILS results show that the engine performance is improved by the closed loop control showing the operation trajectory close to the OOL.