Effective Pre-rating Method Based on Users' Dichotomous Preferences and Average Ratings Fusion for Recommender Systems

  • Cheng, Shulin;Wang, Wanyan;Yang, Shan;Cheng, Xiufang
    • Journal of Information Processing Systems
    • /
    • v.17 no.3
    • /
    • pp.462-472
    • /
    • 2021
  • With an increase in the scale of recommender systems, users' rating data tend to be extremely sparse. Some methods have been utilized to alleviate this problem; nevertheless, it has not been satisfactorily solved yet. Therefore, we propose an effective pre-rating method based on users' dichotomous preferences and average ratings fusion. First, based on a user-item ratings matrix, a new user-item preference matrix was constructed to analyze and model user preferences. The items were then divided into two categories based on a parameterized dynamic threshold. The missing ratings for items that the user was not interested in were directly filled with the lowest user rating; otherwise, fusion ratings were utilized to fill the missing ratings. Further, an optimized parameter λ was introduced to adjust their weights. Finally, we verified our method on a standard dataset. The experimental results show that our method can effectively reduce the prediction error and improve the recommendation quality. As for its application, our method is effective, but not complicated.

A Study on Carbon Monoxide and Other Gases During the Fire Test (A-class:1st Rating & B-class:1st Rating) (한국 A급, B급 1단위 화재 시험시 발생하는 일산화탄소 등의 정량적 연구)

  • Jeong, Incheon;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.44-56
    • /
    • 2013
  • This research is to identify how much toxic combustion gases are produced from Korea standardized real fire test (Class A&B) by using Room Corner Tester (RCT) and how much those gases are possibly dangerous to testing personnel by estimating the level of carboxyhemoglobin (% COHb). It is confirmed that testing personnel can be affected as more than 40% COHb from Class A 9th and 10th rating in respiration minute volume (RMV) 2 and from Class A 5th to Class A 10th rating in RMV 3 during the time for initial three minutes. Also, in the case of Class B real fire tests, although it is considered rather safe for the initial 1 minute, testing personnel can be affected as more than 20% COHb from Class B 16th to 20th rating in RMV 3 during total test time. Currently, the Korea standard is only focusing on the protection measures against the heat, but the it is neglecting the protection measures against toxic combustion gases. Therefore, according to this study, it is strongly recommended that testing personnel should wear a self-contained breathing apparatus, or the equivalence depending on the real fire test rating.

The establishing Korean Industrial Standard of the sound absorber for use in building (흡음률 평가방법의 KS 규격화 방안에 관한 연구)

  • Lee, Tai-Gang;Song, Min-Jung;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.939-944
    • /
    • 2002
  • Recently Korean Industrial Standards has been revised and established newly accordance with the ISO system, especially ISO 140 series. This study aims to introduce and review ISO 11654 which contents rating of sound absorption, and then this study suggests to establish appropriate evaluating method and Korean Industrial Standard of the sound absorber for use in building.

  • PDF

A Study of Enhancing Reliability for Determining the Resistance to Surface Wetting by Imaging Process (이미징 기반의 발수도 판별을 통한 측정 신뢰도 향상에 관한 연구)

  • Kim, Sung-wuk;Chun, Sang Hee;Park, Jae Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.483-489
    • /
    • 2017
  • The purpose of this study was to propose useful suggestions for enhancing reliability to determine the resistance against surface wetting, KS K 0590, by an imaging process. We validated the standard spray test rating chart for determining quantification standard using JAVA script-based imaging process program. All of the acquired images were processed with the image software, Image J (NIH, Nethesda, MD, USA). The study results are as follows. We established the surface area measurement-based quantitative criteria for determining resistance to surface wetting. The standard spray test rating chart was converted into a numerical standard which leads easy-to-determine ratings. We also validated the procedure for imaging treatment by analyzing quantitative data. We introduced the fluorescence image for determining ratings by enabling threshold settings and binary image conversion as an optimal imaging process. It is expected that imaging-based determination for resistant to surface wetting will serve as an accurate and reliable method for KS K 0590.

A Study on the Rating of the Insureds' Anthropometric Data I. Build (피보험체계측치(被保險體計測値)의 평가(評價)에 관한 연구(硏究) 제1보(第1報) 체격(體格))

  • Im, Young-Hoon
    • The Journal of the Korean life insurance medical association
    • /
    • v.3 no.1
    • /
    • pp.103-141
    • /
    • 1986
  • The present study was undertaken to establish the decision standard of builds for the insured by using the ratio of weight-for-height as build index. Materials being examined were the ratio of weight-for-height being calculated from the actually measured heights and weights of a total of 15,838 insured persons who were examined medically at Honam Medical Department of Dong Bang Life Insurance Company, Ltd. from June, 1979 to September, 1985. The ratio of weight-for-height is calculated by the following formula. The ratio of weight-for-height(%)=$\frac{weight(kg){\times}100}{\{height(cm)-100\}{\times}0.9(kg)$ The results were as follows: 1. The distribution of the ratio of weight. for-height of the 15,838 insureds follows Log normal distribution being skewed to the left(the direction of underweight). 2. The ratio of weight-for-height were Log transformed to lead to a sym metrical pattern of distribution in which statistical rules are known to be applied more exactly. Thereafter, the establishment of dicision standard of builds was undertaken by using the log of the ratio of weight-for-height as build index. Through all ages in male, the ratio of weight-for-height indicating the range of standard lives including slight overweighted and underweighted lives besides normal lives is 80-130%, and corresponds to $"M-2{\delta}"-"M+1.5{\delta}"$ and to $M{\pm}20%$ ; in female, 85-135%, and corresponds to $"M-2{\delta}"-"M+1.5{\delta}"$ and to $M{\pm}20%$. Through all ages in male, the ratio of weight-for-height indicating the initial level of super-overweighted and super-underweighted lives is 130-150% and 75-80%,and corresponds to $M+3{\delta}\;and\;M-3{\delta}$ and to M+40% and M-25% respectively;in female, 140-160% and 75-80%, and corresponds to $M+3{\delta}\;and\;M-3{\delta}$ and to M+40%-+50% and M-25% respectively. 3. Author's rating table model for builds(a table of weight per height) is proposed. On the table, the ratings for builds, i. e. standard, super-weighted and super-underweighted lives, are listed.

  • PDF

The Measures of Agreement between the Classification Standard of BMI and that of CDRS in Women university students (여자대학생의 BMI와 신체상평정척도(CDRS) 분류기준에 대한 일치도 검정)

  • Nam, Duck-Hyun
    • Journal of Digital Convergence
    • /
    • v.14 no.2
    • /
    • pp.519-527
    • /
    • 2016
  • This research aims at investigating the measures of agreement between BMI classification standard and that of 9-point contour drawing rating scale(CDRS), verifying their usefulness for the application to the filed, examining university students' substantial understanding of their bodies, and offering correct information regarding the distorted recognition of their bodies. In order to examine the measures of agreement between the classification standard of BMI and that of CDRS, and the women university students' recognition of their body images depending on BMI, Cross tabulation was carried out, and ${\chi}^2$, Spearman rank correlation coefficient and kappa statistics were calculated. As the analysis results, the classification standards of CDRS and BMI judged by general female college students showed statistically the correlation was high with ${\rho}=.719$(p<.001) and an average level of confirmity with ${\kappa}=.506$(p<.001). Based on these results, regarding body shape, sizes and shapes according to racial characteristics need to be controlled later.

A Study on Quantity of Shotcrete Sprayed in a NATM Tunnel Based on Field Measurements (현장 실측자료 분석을 통한 NATM 터널의 숏크리트 투입량에 관한 연구)

  • Lee, Cheol Ju
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.9
    • /
    • pp.47-54
    • /
    • 2011
  • This study has analysed overbreaks, shotcrete rebound and the ratio between the actual quantity of shotcrete sprayed compared to designed quantity measured during a NATM tunnel construction. Based on the measurements of size of the excavated tunnel faces, an average overbreak was about 28.5 cm, which is about 260% of allowable overbreak. The measured shotcrete rebound was about 7.2% in average which is about half the allowable rebound(15%). In addition, due to overbreaks and rebound the actual quantity of shotcrete used in the tunnelling work was about 116.5 % of the designed value. It has been found from the field measurements that the quantity of shotcrete showed some relation with rock mass rating(RMR) and the standard guideline of tunnel supports, but the size of overbreak showed less correlation with RMR and the standard guideline of tunnel supports. Hence, the current tunnel design specifications stating the size of overbreak based entirely on the standard guideline for tunnel supports should perhaps be reestablished. The insight into the design guideline regarding overbreak and actual quantity of shotcrete will be reported and discussed.

Energy Performance Evaluation of Apartment Houses According to Window Energy Consumption Efficiency Rating System in Korea (창호 에너지소비효율등급제에 따른 공동주택의 열성능 평가)

  • Lim, Hee Won;Kim, Dong Yun;Lee, Soo Man;An, Jung Hyuk;Yoon, Jong Ho;Shin, U Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.4
    • /
    • pp.159-166
    • /
    • 2018
  • The Korean fenestration energy consumption efficiency rating system only considers thermal performance of the heat transfer coefficient (U-value) and airtightness excluding optical characteristics of the solar heat gain coefficient (SHGC). This study analyzed annual heating and cooling energy requirements on the middle floor of apartment by optical and thermal performance of windows to evaluate the suitability of the rating system. One hundred and twenty-eight windows were analyzed using THERM and WINDOW 7.4, and energy simulation for a reference model of an apartment house facing south was performed using TRNSYS 17. The results showed that window performance was the main factor in the heating and cooling load. The heating load of the reference model was 539 kWh to 2,022 kW, and the cooling load was 376 kWh to 1,443 kWh. The coefficient of determination ($R^2$) of the heating and cooling loads driven from the SHGC were 0.7437 and 0.9869, which are more compatible than those from the U-value, 0.0558 and 0.4781. Therefore, it is not reasonable to evaluate the energy performance of windows using only the U-value, and the Korean fenestration energy consumption efficiency rating system requires a new evaluation standard, including SHGC.

Performance Evaluations of the Lightning Impulse Voltage Measuring System by Intercomparative Test - in case of full lightning impulse voltage - (뇌충격 측정시스템의 비교시험에 의한 성능평가 - 전파 뇌충격전압 인가시 -)

  • Kim, Ik-Soo;Kim, Young-Bae;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1368-1370
    • /
    • 1995
  • Lightning impulse voltage is essential to evaluate the insulation performance of electric power apparatus. Recently international standard(IEC-60) on high voltage measurement techniques are being revised. In the draft of this standard, a new calibration method is introduced and the accuracy of most industrial measuring systems is maintained by means of comparison test against the reference measuring systems. Intercomparison tests of dividers for lightning impulse measurement were carried out by KERI. The shielded resisitive divider with 700kV rating developed by KERI were done comparison test with PTB divider with 300kV rating which have the similar charateristics as that were circulated among the laboratories. This paper reports on the comparison test results with full lightning impulse voltages from 126kV to 240kV. It is demonstrated that KERI are capable of realizing the idea in the revision of the IEC standand, that is, to establish traceability.

  • PDF

A Comparative Study on the Assessment Items of Korea's Apartment Building Certification Systems (국내 공동주택 관련 인증제도의 세부 항목에 대한 비교 분석에 관한 연구)

  • Jung, Ji-Na;Tae, Choon-Seob;Yang, Jeong-Hoon;Park, Sang-Dong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.116-123
    • /
    • 2010
  • A various building certification systems are being enforced in Korea. However, the enforcement of many building certification systems has brought on the concerned people's confusion and the operation of various building certification systems which have similar assesment items causes much time and economical losses. Therefore, in this paper, the features of the GBCS(Green Building Certification System), Housing Performance Indication System, Building Energy Rating System, and Green Home Standard and Performance Evaluation System are compared and the correlations among each building certification system are analysed. As a result, it is presented that a considerable number of assessment items were so similar and identical that integration of building certification systems is needed for effective operation of these systems.